STM32L4x6
1.5
STM32L4x6
CM4
r1p0
little
false
false
3
false
8
32
0x20
0x0
0xFFFFFFFF
DAC
Digital-to-analog converter
DAC
0x40007400
0x0
0x400
registers
CR
CR
control register
0x0
0x20
read-write
0x00000000
EN1
DAC channel1 enable
0
1
TEN1
DAC channel1 trigger
enable
2
1
TSEL1
DAC channel1 trigger
selection
3
3
WAVE1
DAC channel1 noise/triangle wave
generation enable
6
2
MAMP1
DAC channel1 mask/amplitude
selector
8
4
DMAEN1
DAC channel1 DMA enable
12
1
DMAUDRIE1
DAC channel1 DMA Underrun Interrupt
enable
13
1
CEN1
DAC Channel 1 calibration
enable
14
1
EN2
DAC channel2 enable
16
1
TEN2
DAC channel2 trigger
enable
18
1
TSEL2
DAC channel2 trigger
selection
19
3
WAVE2
DAC channel2 noise/triangle wave
generation enable
22
2
MAMP2
DAC channel2 mask/amplitude
selector
24
4
DMAEN2
DAC channel2 DMA enable
28
1
DMAUDRIE2
DAC channel2 DMA underrun interrupt
enable
29
1
CEN2
DAC Channel 2 calibration
enable
30
1
SWTRIGR
SWTRIGR
software trigger register
0x4
0x20
write-only
0x00000000
SWTRIG1
DAC channel1 software
trigger
0
1
SWTRIG2
DAC channel2 software
trigger
1
1
DHR12R1
DHR12R1
channel1 12-bit right-aligned data holding
register
0x8
0x20
read-write
0x00000000
DACC1DHR
DAC channel1 12-bit right-aligned
data
0
12
DHR12L1
DHR12L1
channel1 12-bit left-aligned data holding
register
0xC
0x20
read-write
0x00000000
DACC1DHR
DAC channel1 12-bit left-aligned
data
4
12
DHR8R1
DHR8R1
channel1 8-bit right-aligned data holding
register
0x10
0x20
read-write
0x00000000
DACC1DHR
DAC channel1 8-bit right-aligned
data
0
8
DHR12R2
DHR12R2
channel2 12-bit right aligned data holding
register
0x14
0x20
read-write
0x00000000
DACC2DHR
DAC channel2 12-bit right-aligned
data
0
12
DHR12L2
DHR12L2
channel2 12-bit left aligned data holding
register
0x18
0x20
read-write
0x00000000
DACC2DHR
DAC channel2 12-bit left-aligned
data
4
12
DHR8R2
DHR8R2
channel2 8-bit right-aligned data holding
register
0x1C
0x20
read-write
0x00000000
DACC2DHR
DAC channel2 8-bit right-aligned
data
0
8
DHR12RD
DHR12RD
Dual DAC 12-bit right-aligned data holding
register
0x20
0x20
read-write
0x00000000
DACC1DHR
DAC channel1 12-bit right-aligned
data
0
12
DACC2DHR
DAC channel2 12-bit right-aligned
data
16
12
DHR12LD
DHR12LD
DUAL DAC 12-bit left aligned data holding
register
0x24
0x20
read-write
0x00000000
DACC1DHR
DAC channel1 12-bit left-aligned
data
4
12
DACC2DHR
DAC channel2 12-bit left-aligned
data
20
12
DHR8RD
DHR8RD
DUAL DAC 8-bit right aligned data holding
register
0x28
0x20
read-write
0x00000000
DACC1DHR
DAC channel1 8-bit right-aligned
data
0
8
DACC2DHR
DAC channel2 8-bit right-aligned
data
8
8
DOR1
DOR1
channel1 data output register
0x2C
0x20
read-only
0x00000000
DACC1DOR
DAC channel1 data output
0
12
DOR2
DOR2
channel2 data output register
0x30
0x20
read-only
0x00000000
DACC2DOR
DAC channel2 data output
0
12
SR
SR
status register
0x34
0x20
0x00000000
DMAUDR1
DAC channel1 DMA underrun
flag
13
1
read-write
CAL_FLAG1
DAC Channel 1 calibration offset
status
14
1
read-only
BWST1
DAC Channel 1 busy writing sample time
flag
15
1
read-only
DMAUDR2
DAC channel2 DMA underrun
flag
29
1
read-write
CAL_FLAG2
DAC Channel 2 calibration offset
status
30
1
read-only
BWST2
DAC Channel 2 busy writing sample time
flag
31
1
read-only
CCR
CCR
calibration control register
0x38
0x20
read-write
0x00000000
OTRIM1
DAC Channel 1 offset trimming
value
0
5
OTRIM2
DAC Channel 2 offset trimming
value
16
5
MCR
MCR
mode control register
0x3C
0x20
read-write
0x00000000
MODE1
DAC Channel 1 mode
0
3
MODE2
DAC Channel 2 mode
16
3
SHSR1
SHSR1
Sample and Hold sample time register
1
0x40
0x20
read-write
0x00000000
TSAMPLE1
DAC Channel 1 sample Time
0
10
SHSR2
SHSR2
Sample and Hold sample time register
2
0x44
0x20
read-write
0x00000000
TSAMPLE2
DAC Channel 2 sample Time
0
10
SHHR
SHHR
Sample and Hold hold time
register
0x48
0x20
read-write
0x00010001
THOLD1
DAC Channel 1 hold Time
0
10
THOLD2
DAC Channel 2 hold time
16
10
SHRR
SHRR
Sample and Hold refresh time
register
0x4C
0x20
read-write
0x00000001
TREFRESH1
DAC Channel 1 refresh Time
0
8
TREFRESH2
DAC Channel 2 refresh Time
16
8
DMA1
Direct memory access controller
DMA
0x40020000
0x0
0x400
registers
DMA1_CH1
DMA1 Channel1 global interrupt
11
DMA1_CH2
DMA1 Channel2 global interrupt
12
DMA1_CH3
DMA1 Channel3 interrupt
13
DMA1_CH4
DMA1 Channel4 interrupt
14
DMA1_CH5
DMA1 Channel5 interrupt
15
DMA1_CH6
DMA1 Channel6 interrupt
16
DMA1_CH7
DMA1 Channel 7 interrupt
17
ISR
ISR
interrupt status register
0x0
0x20
read-only
0x00000000
TEIF7
Channel x transfer error flag (x = 1
..7)
27
1
HTIF7
Channel x half transfer flag (x = 1
..7)
26
1
TCIF7
Channel x transfer complete flag (x = 1
..7)
25
1
GIF7
Channel x global interrupt flag (x = 1
..7)
24
1
TEIF6
Channel x transfer error flag (x = 1
..7)
23
1
HTIF6
Channel x half transfer flag (x = 1
..7)
22
1
TCIF6
Channel x transfer complete flag (x = 1
..7)
21
1
GIF6
Channel x global interrupt flag (x = 1
..7)
20
1
TEIF5
Channel x transfer error flag (x = 1
..7)
19
1
HTIF5
Channel x half transfer flag (x = 1
..7)
18
1
TCIF5
Channel x transfer complete flag (x = 1
..7)
17
1
GIF5
Channel x global interrupt flag (x = 1
..7)
16
1
TEIF4
Channel x transfer error flag (x = 1
..7)
15
1
HTIF4
Channel x half transfer flag (x = 1
..7)
14
1
TCIF4
Channel x transfer complete flag (x = 1
..7)
13
1
GIF4
Channel x global interrupt flag (x = 1
..7)
12
1
TEIF3
Channel x transfer error flag (x = 1
..7)
11
1
HTIF3
Channel x half transfer flag (x = 1
..7)
10
1
TCIF3
Channel x transfer complete flag (x = 1
..7)
9
1
GIF3
Channel x global interrupt flag (x = 1
..7)
8
1
TEIF2
Channel x transfer error flag (x = 1
..7)
7
1
HTIF2
Channel x half transfer flag (x = 1
..7)
6
1
TCIF2
Channel x transfer complete flag (x = 1
..7)
5
1
GIF2
Channel x global interrupt flag (x = 1
..7)
4
1
TEIF1
Channel x transfer error flag (x = 1
..7)
3
1
HTIF1
Channel x half transfer flag (x = 1
..7)
2
1
TCIF1
Channel x transfer complete flag (x = 1
..7)
1
1
GIF1
Channel x global interrupt flag (x = 1
..7)
0
1
IFCR
IFCR
interrupt flag clear register
0x4
0x20
write-only
0x00000000
CTEIF7
Channel x transfer error clear (x = 1
..7)
27
1
CHTIF7
Channel x half transfer clear (x = 1
..7)
26
1
CTCIF7
Channel x transfer complete clear (x = 1
..7)
25
1
CGIF7
Channel x global interrupt clear (x = 1
..7)
24
1
CTEIF6
Channel x transfer error clear (x = 1
..7)
23
1
CHTIF6
Channel x half transfer clear (x = 1
..7)
22
1
CTCIF6
Channel x transfer complete clear (x = 1
..7)
21
1
CGIF6
Channel x global interrupt clear (x = 1
..7)
20
1
CTEIF5
Channel x transfer error clear (x = 1
..7)
19
1
CHTIF5
Channel x half transfer clear (x = 1
..7)
18
1
CTCIF5
Channel x transfer complete clear (x = 1
..7)
17
1
CGIF5
Channel x global interrupt clear (x = 1
..7)
16
1
CTEIF4
Channel x transfer error clear (x = 1
..7)
15
1
CHTIF4
Channel x half transfer clear (x = 1
..7)
14
1
CTCIF4
Channel x transfer complete clear (x = 1
..7)
13
1
CGIF4
Channel x global interrupt clear (x = 1
..7)
12
1
CTEIF3
Channel x transfer error clear (x = 1
..7)
11
1
CHTIF3
Channel x half transfer clear (x = 1
..7)
10
1
CTCIF3
Channel x transfer complete clear (x = 1
..7)
9
1
CGIF3
Channel x global interrupt clear (x = 1
..7)
8
1
CTEIF2
Channel x transfer error clear (x = 1
..7)
7
1
CHTIF2
Channel x half transfer clear (x = 1
..7)
6
1
CTCIF2
Channel x transfer complete clear (x = 1
..7)
5
1
CGIF2
Channel x global interrupt clear (x = 1
..7)
4
1
CTEIF1
Channel x transfer error clear (x = 1
..7)
3
1
CHTIF1
Channel x half transfer clear (x = 1
..7)
2
1
CTCIF1
Channel x transfer complete clear (x = 1
..7)
1
1
CGIF1
Channel x global interrupt clear (x = 1
..7)
0
1
CCR1
CCR1
channel x configuration
register
0x8
0x20
read-write
0x00000000
MEM2MEM
Memory to memory mode
14
1
PL
Channel priority level
12
2
MSIZE
Memory size
10
2
PSIZE
Peripheral size
8
2
MINC
Memory increment mode
7
1
PINC
Peripheral increment mode
6
1
CIRC
Circular mode
5
1
DIR
Data transfer direction
4
1
TEIE
Transfer error interrupt
enable
3
1
HTIE
Half transfer interrupt
enable
2
1
TCIE
Transfer complete interrupt
enable
1
1
EN
Channel enable
0
1
CNDTR1
CNDTR1
channel x number of data
register
0xC
0x20
read-write
0x00000000
NDT
Number of data to transfer
0
16
CPAR1
CPAR1
channel x peripheral address
register
0x10
0x20
read-write
0x00000000
PA
Peripheral address
0
32
CMAR1
CMAR1
channel x memory address
register
0x14
0x20
read-write
0x00000000
MA
Memory address
0
32
CCR2
CCR2
channel x configuration
register
0x1C
0x20
read-write
0x00000000
MEM2MEM
Memory to memory mode
14
1
PL
Channel priority level
12
2
MSIZE
Memory size
10
2
PSIZE
Peripheral size
8
2
MINC
Memory increment mode
7
1
PINC
Peripheral increment mode
6
1
CIRC
Circular mode
5
1
DIR
Data transfer direction
4
1
TEIE
Transfer error interrupt
enable
3
1
HTIE
Half transfer interrupt
enable
2
1
TCIE
Transfer complete interrupt
enable
1
1
EN
Channel enable
0
1
CNDTR2
CNDTR2
channel x number of data
register
0x20
0x20
read-write
0x00000000
NDT
Number of data to transfer
0
16
CPAR2
CPAR2
channel x peripheral address
register
0x24
0x20
read-write
0x00000000
PA
Peripheral address
0
32
CMAR2
CMAR2
channel x memory address
register
0x28
0x20
read-write
0x00000000
MA
Memory address
0
32
CCR3
CCR3
channel x configuration
register
0x30
0x20
read-write
0x00000000
MEM2MEM
Memory to memory mode
14
1
PL
Channel priority level
12
2
MSIZE
Memory size
10
2
PSIZE
Peripheral size
8
2
MINC
Memory increment mode
7
1
PINC
Peripheral increment mode
6
1
CIRC
Circular mode
5
1
DIR
Data transfer direction
4
1
TEIE
Transfer error interrupt
enable
3
1
HTIE
Half transfer interrupt
enable
2
1
TCIE
Transfer complete interrupt
enable
1
1
EN
Channel enable
0
1
CNDTR3
CNDTR3
channel x number of data
register
0x34
0x20
read-write
0x00000000
NDT
Number of data to transfer
0
16
CPAR3
CPAR3
channel x peripheral address
register
0x38
0x20
read-write
0x00000000
PA
Peripheral address
0
32
CMAR3
CMAR3
channel x memory address
register
0x3C
0x20
read-write
0x00000000
MA
Memory address
0
32
CCR4
CCR4
channel x configuration
register
0x44
0x20
read-write
0x00000000
MEM2MEM
Memory to memory mode
14
1
PL
Channel priority level
12
2
MSIZE
Memory size
10
2
PSIZE
Peripheral size
8
2
MINC
Memory increment mode
7
1
PINC
Peripheral increment mode
6
1
CIRC
Circular mode
5
1
DIR
Data transfer direction
4
1
TEIE
Transfer error interrupt
enable
3
1
HTIE
Half transfer interrupt
enable
2
1
TCIE
Transfer complete interrupt
enable
1
1
EN
Channel enable
0
1
CNDTR4
CNDTR4
channel x number of data
register
0x48
0x20
read-write
0x00000000
NDT
Number of data to transfer
0
16
CPAR4
CPAR4
channel x peripheral address
register
0x4C
0x20
read-write
0x00000000
PA
Peripheral address
0
32
CMAR4
CMAR4
channel x memory address
register
0x50
0x20
read-write
0x00000000
MA
Memory address
0
32
CCR5
CCR5
channel x configuration
register
0x58
0x20
read-write
0x00000000
MEM2MEM
Memory to memory mode
14
1
PL
Channel priority level
12
2
MSIZE
Memory size
10
2
PSIZE
Peripheral size
8
2
MINC
Memory increment mode
7
1
PINC
Peripheral increment mode
6
1
CIRC
Circular mode
5
1
DIR
Data transfer direction
4
1
TEIE
Transfer error interrupt
enable
3
1
HTIE
Half transfer interrupt
enable
2
1
TCIE
Transfer complete interrupt
enable
1
1
EN
Channel enable
0
1
CNDTR5
CNDTR5
channel x number of data
register
0x5C
0x20
read-write
0x00000000
NDT
Number of data to transfer
0
16
CPAR5
CPAR5
channel x peripheral address
register
0x60
0x20
read-write
0x00000000
PA
Peripheral address
0
32
CMAR5
CMAR5
channel x memory address
register
0x64
0x20
read-write
0x00000000
MA
Memory address
0
32
CCR6
CCR6
channel x configuration
register
0x6C
0x20
read-write
0x00000000
MEM2MEM
Memory to memory mode
14
1
PL
Channel priority level
12
2
MSIZE
Memory size
10
2
PSIZE
Peripheral size
8
2
MINC
Memory increment mode
7
1
PINC
Peripheral increment mode
6
1
CIRC
Circular mode
5
1
DIR
Data transfer direction
4
1
TEIE
Transfer error interrupt
enable
3
1
HTIE
Half transfer interrupt
enable
2
1
TCIE
Transfer complete interrupt
enable
1
1
EN
Channel enable
0
1
CNDTR6
CNDTR6
channel x number of data
register
0x70
0x20
read-write
0x00000000
NDT
Number of data to transfer
0
16
CPAR6
CPAR6
channel x peripheral address
register
0x74
0x20
read-write
0x00000000
PA
Peripheral address
0
32
CMAR6
CMAR6
channel x memory address
register
0x78
0x20
read-write
0x00000000
MA
Memory address
0
32
CCR7
CCR7
channel x configuration
register
0x80
0x20
read-write
0x00000000
MEM2MEM
Memory to memory mode
14
1
PL
Channel priority level
12
2
MSIZE
Memory size
10
2
PSIZE
Peripheral size
8
2
MINC
Memory increment mode
7
1
PINC
Peripheral increment mode
6
1
CIRC
Circular mode
5
1
DIR
Data transfer direction
4
1
TEIE
Transfer error interrupt
enable
3
1
HTIE
Half transfer interrupt
enable
2
1
TCIE
Transfer complete interrupt
enable
1
1
EN
Channel enable
0
1
CNDTR7
CNDTR7
channel x number of data
register
0x84
0x20
read-write
0x00000000
NDT
Number of data to transfer
0
16
CPAR7
CPAR7
channel x peripheral address
register
0x88
0x20
read-write
0x00000000
PA
Peripheral address
0
32
CMAR7
CMAR7
channel x memory address
register
0x8C
0x20
read-write
0x00000000
MA
Memory address
0
32
CSELR
CSELR
channel selection register
0xA8
0x20
read-write
0x00000000
C7S
DMA channel 7 selection
24
4
C6S
DMA channel 6 selection
20
4
C5S
DMA channel 5 selection
16
4
C4S
DMA channel 4 selection
12
4
C3S
DMA channel 3 selection
8
4
C2S
DMA channel 2 selection
4
4
C1S
DMA channel 1 selection
0
4
DMA2
0x40020400
DMA2_CH1
DMA2 Channel 1 global Interrupt
56
DMA2_CH2
DMA2 Channel 2 global Interrupt
57
DMA2_CH3
DMA2 Channel 3 global Interrupt
58
DMA2_CH4
DMA2 Channel 4 global Interrupt
59
DMA2_CH5
DMA2 Channel 5 global Interrupt
60
DMA2_CH6
DMA2 Channel 6 global Interrupt
68
DMA2_CH7
DMA2 Channel 7 global Interrupt
69
CRC
Cyclic redundancy check calculation
unit
CRC
0x40023000
0x0
0x400
registers
DR
DR
Data register
0x0
0x20
read-write
0xFFFFFFFF
DR
Data register bits
0
32
IDR
IDR
Independent data register
0x4
0x20
read-write
0x00000000
IDR
General-purpose 8-bit data register
bits
0
8
CR
CR
Control register
0x8
0x20
0x00000000
REV_OUT
Reverse output data
7
1
read-write
REV_IN
Reverse input data
5
2
read-write
POLYSIZE
Polynomial size
3
2
read-write
RESET
RESET bit
0
1
write-only
INIT
INIT
Initial CRC value
0x10
0x20
read-write
0xFFFFFFFF
CRC_INIT
Programmable initial CRC
value
0
32
POL
POL
polynomial
0x14
0x20
read-write
0x04C11DB7
Polynomialcoefficients
Programmable polynomial
0
32
LCD
Liquid crystal display controller
LCD
0x40002400
0x0
0x400
registers
LCD
LCD global interrupt
78
CR
CR
control register
0x0
0x20
read-write
0x00000000
BIAS
Bias selector
5
2
DUTY
Duty selection
2
3
VSEL
Voltage source selection
1
1
LCDEN
LCD controller enable
0
1
MUX_SEG
Mux segment enable
7
1
BUFEN
Voltage output buffer
enable
8
1
FCR
FCR
frame control register
0x4
0x20
read-write
0x00000000
PS
PS 16-bit prescaler
22
4
DIV
DIV clock divider
18
4
BLINK
Blink mode selection
16
2
BLINKF
Blink frequency selection
13
3
CC
Contrast control
10
3
DEAD
Dead time duration
7
3
PON
Pulse ON duration
4
3
UDDIE
Update display done interrupt
enable
3
1
SOFIE
Start of frame interrupt
enable
1
1
HD
High drive enable
0
1
SR
SR
status register
0x8
0x20
0x00000020
FCRSF
LCD Frame Control Register
Synchronization flag
5
1
read-only
RDY
Ready flag
4
1
read-only
UDD
Update Display Done
3
1
read-only
UDR
Update display request
2
1
write-only
SOF
Start of frame flag
1
1
read-only
ENS
ENS
0
1
read-only
CLR
CLR
clear register
0xC
0x20
write-only
0x00000000
UDDC
Update display done clear
3
1
SOFC
Start of frame flag clear
1
1
RAM_COM0
RAM_COM0
display memory
0x14
0x20
read-write
0x00000000
S30
S30
30
1
S29
S29
29
1
S28
S28
28
1
S27
S27
27
1
S26
S26
26
1
S25
S25
25
1
S24
S24
24
1
S23
S23
23
1
S22
S22
22
1
S21
S21
21
1
S20
S20
20
1
S19
S19
19
1
S18
S18
18
1
S17
S17
17
1
S16
S16
16
1
S15
S15
15
1
S14
S14
14
1
S13
S13
13
1
S12
S12
12
1
S11
S11
11
1
S10
S10
10
1
S09
S09
9
1
S08
S08
8
1
S07
S07
7
1
S06
S06
6
1
S05
S05
5
1
S04
S04
4
1
S03
S03
3
1
S02
S02
2
1
S01
S01
1
1
S00
S00
0
1
RAM_COM1
RAM_COM1
display memory
0x1C
0x20
read-write
0x00000000
S31
S31
31
1
S30
S30
30
1
S29
S29
29
1
S28
S28
28
1
S27
S27
27
1
S26
S26
26
1
S25
S25
25
1
S24
S24
24
1
S23
S23
23
1
S22
S22
22
1
S21
S21
21
1
S20
S20
20
1
S19
S19
19
1
S18
S18
18
1
S17
S17
17
1
S16
S16
16
1
S15
S15
15
1
S14
S14
14
1
S13
S13
13
1
S12
S12
12
1
S11
S11
11
1
S10
S10
10
1
S09
S09
9
1
S08
S08
8
1
S07
S07
7
1
S06
S06
6
1
S05
S05
5
1
S04
S04
4
1
S03
S03
3
1
S02
S02
2
1
S01
S01
1
1
S00
S00
0
1
RAM_COM2
RAM_COM2
display memory
0x24
0x20
read-write
0x00000000
S31
S31
31
1
S30
S30
30
1
S29
S29
29
1
S28
S28
28
1
S27
S27
27
1
S26
S26
26
1
S25
S25
25
1
S24
S24
24
1
S23
S23
23
1
S22
S22
22
1
S21
S21
21
1
S20
S20
20
1
S19
S19
19
1
S18
S18
18
1
S17
S17
17
1
S16
S16
16
1
S15
S15
15
1
S14
S14
14
1
S13
S13
13
1
S12
S12
12
1
S11
S11
11
1
S10
S10
10
1
S09
S09
9
1
S08
S08
8
1
S07
S07
7
1
S06
S06
6
1
S05
S05
5
1
S04
S04
4
1
S03
S03
3
1
S02
S02
2
1
S01
S01
1
1
S00
S00
0
1
RAM_COM3
RAM_COM3
display memory
0x2C
0x20
read-write
0x00000000
S31
S31
31
1
S30
S30
30
1
S29
S29
29
1
S28
S28
28
1
S27
S27
27
1
S26
S26
26
1
S25
S25
25
1
S24
S24
24
1
S23
S23
23
1
S22
S22
22
1
S21
S21
21
1
S20
S20
20
1
S19
S19
19
1
S18
S18
18
1
S17
S17
17
1
S16
S16
16
1
S15
S15
15
1
S14
S14
14
1
S13
S13
13
1
S12
S12
12
1
S11
S11
11
1
S10
S10
10
1
S09
S09
9
1
S08
S08
8
1
S07
S07
7
1
S06
S06
6
1
S05
S05
5
1
S04
S04
4
1
S03
S03
3
1
S02
S02
2
1
S01
S01
1
1
S00
S00
0
1
RAM_COM4
RAM_COM4
display memory
0x34
0x20
read-write
0x00000000
S31
S31
31
1
S30
S30
30
1
S29
S29
29
1
S28
S28
28
1
S27
S27
27
1
S26
S26
26
1
S25
S25
25
1
S24
S24
24
1
S23
S23
23
1
S22
S22
22
1
S21
S21
21
1
S20
S20
20
1
S19
S19
19
1
S18
S18
18
1
S17
S17
17
1
S16
S16
16
1
S15
S15
15
1
S14
S14
14
1
S13
S13
13
1
S12
S12
12
1
S11
S11
11
1
S10
S10
10
1
S09
S09
9
1
S08
S08
8
1
S07
S07
7
1
S06
S06
6
1
S05
S05
5
1
S04
S04
4
1
S03
S03
3
1
S02
S02
2
1
S01
S01
1
1
S00
S00
0
1
RAM_COM5
RAM_COM5
display memory
0x3C
0x20
read-write
0x00000000
S31
S31
31
1
S30
S30
30
1
S29
S29
29
1
S28
S28
28
1
S27
S27
27
1
S26
S26
26
1
S25
S25
25
1
S24
S24
24
1
S23
S23
23
1
S22
S22
22
1
S21
S21
21
1
S20
S20
20
1
S19
S19
19
1
S18
S18
18
1
S17
S17
17
1
S16
S16
16
1
S15
S15
15
1
S14
S14
14
1
S13
S13
13
1
S12
S12
12
1
S11
S11
11
1
S10
S10
10
1
S09
S09
9
1
S08
S08
8
1
S07
S07
7
1
S06
S06
6
1
S05
S05
5
1
S04
S04
4
1
S03
S03
3
1
S02
S02
2
1
S01
S01
1
1
S00
S00
0
1
RAM_COM6
RAM_COM6
display memory
0x44
0x20
read-write
0x00000000
S31
S31
31
1
S30
S30
30
1
S29
S29
29
1
S28
S28
28
1
S27
S27
27
1
S26
S26
26
1
S25
S25
25
1
S24
S24
24
1
S23
S23
23
1
S22
S22
22
1
S21
S21
21
1
S20
S20
20
1
S19
S19
19
1
S18
S18
18
1
S17
S17
17
1
S16
S16
16
1
S15
S15
15
1
S14
S14
14
1
S13
S13
13
1
S12
S12
12
1
S11
S11
11
1
S10
S10
10
1
S09
S09
9
1
S08
S08
8
1
S07
S07
7
1
S06
S06
6
1
S05
S05
5
1
S04
S04
4
1
S03
S03
3
1
S02
S02
2
1
S01
S01
1
1
S00
S00
0
1
RAM_COM7
RAM_COM7
display memory
0x4C
0x20
read-write
0x00000000
S31
S31
31
1
S30
S30
30
1
S29
S29
29
1
S28
S28
28
1
S27
S27
27
1
S26
S26
26
1
S25
S25
25
1
S24
S24
24
1
S23
S23
23
1
S22
S22
22
1
S21
S21
21
1
S20
S20
20
1
S19
S19
19
1
S18
S18
18
1
S17
S17
17
1
S16
S16
16
1
S15
S15
15
1
S14
S14
14
1
S13
S13
13
1
S12
S12
12
1
S11
S11
11
1
S10
S10
10
1
S09
S09
9
1
S08
S08
8
1
S07
S07
7
1
S06
S06
6
1
S05
S05
5
1
S04
S04
4
1
S03
S03
3
1
S02
S02
2
1
S01
S01
1
1
S00
S00
0
1
TSC
Touch sensing controller
TSC
0x40024000
0x0
0x400
registers
TSC
TSC global interrupt
77
CR
CR
control register
0x0
0x20
read-write
0x00000000
CTPH
Charge transfer pulse high
28
4
CTPL
Charge transfer pulse low
24
4
SSD
Spread spectrum deviation
17
7
SSE
Spread spectrum enable
16
1
SSPSC
Spread spectrum prescaler
15
1
PGPSC
pulse generator prescaler
12
3
MCV
Max count value
5
3
IODEF
I/O Default mode
4
1
SYNCPOL
Synchronization pin
polarity
3
1
AM
Acquisition mode
2
1
START
Start a new acquisition
1
1
TSCE
Touch sensing controller
enable
0
1
IER
IER
interrupt enable register
0x4
0x20
read-write
0x00000000
MCEIE
Max count error interrupt
enable
1
1
EOAIE
End of acquisition interrupt
enable
0
1
ICR
ICR
interrupt clear register
0x8
0x20
read-write
0x00000000
MCEIC
Max count error interrupt
clear
1
1
EOAIC
End of acquisition interrupt
clear
0
1
ISR
ISR
interrupt status register
0xC
0x20
read-write
0x00000000
MCEF
Max count error flag
1
1
EOAF
End of acquisition flag
0
1
IOHCR
IOHCR
I/O hysteresis control
register
0x10
0x20
read-write
0xFFFFFFFF
G8_IO4
G8_IO4
31
1
G8_IO3
G8_IO3
30
1
G8_IO2
G8_IO2
29
1
G8_IO1
G8_IO1
28
1
G7_IO4
G7_IO4
27
1
G7_IO3
G7_IO3
26
1
G7_IO2
G7_IO2
25
1
G7_IO1
G7_IO1
24
1
G6_IO4
G6_IO4
23
1
G6_IO3
G6_IO3
22
1
G6_IO2
G6_IO2
21
1
G6_IO1
G6_IO1
20
1
G5_IO4
G5_IO4
19
1
G5_IO3
G5_IO3
18
1
G5_IO2
G5_IO2
17
1
G5_IO1
G5_IO1
16
1
G4_IO4
G4_IO4
15
1
G4_IO3
G4_IO3
14
1
G4_IO2
G4_IO2
13
1
G4_IO1
G4_IO1
12
1
G3_IO4
G3_IO4
11
1
G3_IO3
G3_IO3
10
1
G3_IO2
G3_IO2
9
1
G3_IO1
G3_IO1
8
1
G2_IO4
G2_IO4
7
1
G2_IO3
G2_IO3
6
1
G2_IO2
G2_IO2
5
1
G2_IO1
G2_IO1
4
1
G1_IO4
G1_IO4
3
1
G1_IO3
G1_IO3
2
1
G1_IO2
G1_IO2
1
1
G1_IO1
G1_IO1
0
1
IOASCR
IOASCR
I/O analog switch control
register
0x18
0x20
read-write
0x00000000
G8_IO4
G8_IO4
31
1
G8_IO3
G8_IO3
30
1
G8_IO2
G8_IO2
29
1
G8_IO1
G8_IO1
28
1
G7_IO4
G7_IO4
27
1
G7_IO3
G7_IO3
26
1
G7_IO2
G7_IO2
25
1
G7_IO1
G7_IO1
24
1
G6_IO4
G6_IO4
23
1
G6_IO3
G6_IO3
22
1
G6_IO2
G6_IO2
21
1
G6_IO1
G6_IO1
20
1
G5_IO4
G5_IO4
19
1
G5_IO3
G5_IO3
18
1
G5_IO2
G5_IO2
17
1
G5_IO1
G5_IO1
16
1
G4_IO4
G4_IO4
15
1
G4_IO3
G4_IO3
14
1
G4_IO2
G4_IO2
13
1
G4_IO1
G4_IO1
12
1
G3_IO4
G3_IO4
11
1
G3_IO3
G3_IO3
10
1
G3_IO2
G3_IO2
9
1
G3_IO1
G3_IO1
8
1
G2_IO4
G2_IO4
7
1
G2_IO3
G2_IO3
6
1
G2_IO2
G2_IO2
5
1
G2_IO1
G2_IO1
4
1
G1_IO4
G1_IO4
3
1
G1_IO3
G1_IO3
2
1
G1_IO2
G1_IO2
1
1
G1_IO1
G1_IO1
0
1
IOSCR
IOSCR
I/O sampling control register
0x20
0x20
read-write
0x00000000
G8_IO4
G8_IO4
31
1
G8_IO3
G8_IO3
30
1
G8_IO2
G8_IO2
29
1
G8_IO1
G8_IO1
28
1
G7_IO4
G7_IO4
27
1
G7_IO3
G7_IO3
26
1
G7_IO2
G7_IO2
25
1
G7_IO1
G7_IO1
24
1
G6_IO4
G6_IO4
23
1
G6_IO3
G6_IO3
22
1
G6_IO2
G6_IO2
21
1
G6_IO1
G6_IO1
20
1
G5_IO4
G5_IO4
19
1
G5_IO3
G5_IO3
18
1
G5_IO2
G5_IO2
17
1
G5_IO1
G5_IO1
16
1
G4_IO4
G4_IO4
15
1
G4_IO3
G4_IO3
14
1
G4_IO2
G4_IO2
13
1
G4_IO1
G4_IO1
12
1
G3_IO4
G3_IO4
11
1
G3_IO3
G3_IO3
10
1
G3_IO2
G3_IO2
9
1
G3_IO1
G3_IO1
8
1
G2_IO4
G2_IO4
7
1
G2_IO3
G2_IO3
6
1
G2_IO2
G2_IO2
5
1
G2_IO1
G2_IO1
4
1
G1_IO4
G1_IO4
3
1
G1_IO3
G1_IO3
2
1
G1_IO2
G1_IO2
1
1
G1_IO1
G1_IO1
0
1
IOCCR
IOCCR
I/O channel control register
0x28
0x20
read-write
0x00000000
G8_IO4
G8_IO4
31
1
G8_IO3
G8_IO3
30
1
G8_IO2
G8_IO2
29
1
G8_IO1
G8_IO1
28
1
G7_IO4
G7_IO4
27
1
G7_IO3
G7_IO3
26
1
G7_IO2
G7_IO2
25
1
G7_IO1
G7_IO1
24
1
G6_IO4
G6_IO4
23
1
G6_IO3
G6_IO3
22
1
G6_IO2
G6_IO2
21
1
G6_IO1
G6_IO1
20
1
G5_IO4
G5_IO4
19
1
G5_IO3
G5_IO3
18
1
G5_IO2
G5_IO2
17
1
G5_IO1
G5_IO1
16
1
G4_IO4
G4_IO4
15
1
G4_IO3
G4_IO3
14
1
G4_IO2
G4_IO2
13
1
G4_IO1
G4_IO1
12
1
G3_IO4
G3_IO4
11
1
G3_IO3
G3_IO3
10
1
G3_IO2
G3_IO2
9
1
G3_IO1
G3_IO1
8
1
G2_IO4
G2_IO4
7
1
G2_IO3
G2_IO3
6
1
G2_IO2
G2_IO2
5
1
G2_IO1
G2_IO1
4
1
G1_IO4
G1_IO4
3
1
G1_IO3
G1_IO3
2
1
G1_IO2
G1_IO2
1
1
G1_IO1
G1_IO1
0
1
IOGCSR
IOGCSR
I/O group control status
register
0x30
0x20
0x00000000
G8S
Analog I/O group x status
23
1
read-only
G7S
Analog I/O group x status
22
1
read-only
G6S
Analog I/O group x status
21
1
read-only
G5S
Analog I/O group x status
20
1
read-only
G4S
Analog I/O group x status
19
1
read-only
G3S
Analog I/O group x status
18
1
read-only
G2S
Analog I/O group x status
17
1
read-only
G1S
Analog I/O group x status
16
1
read-only
G8E
Analog I/O group x enable
7
1
read-write
G7E
Analog I/O group x enable
6
1
read-write
G6E
Analog I/O group x enable
5
1
read-write
G5E
Analog I/O group x enable
4
1
read-write
G4E
Analog I/O group x enable
3
1
read-write
G3E
Analog I/O group x enable
2
1
read-write
G2E
Analog I/O group x enable
1
1
read-write
G1E
Analog I/O group x enable
0
1
read-write
IOG1CR
IOG1CR
I/O group x counter register
0x34
0x20
read-only
0x00000000
CNT
Counter value
0
14
IOG2CR
IOG2CR
I/O group x counter register
0x38
0x20
read-only
0x00000000
CNT
Counter value
0
14
IOG3CR
IOG3CR
I/O group x counter register
0x3C
0x20
read-only
0x00000000
CNT
Counter value
0
14
IOG4CR
IOG4CR
I/O group x counter register
0x40
0x20
read-only
0x00000000
CNT
Counter value
0
14
IOG5CR
IOG5CR
I/O group x counter register
0x44
0x20
read-only
0x00000000
CNT
Counter value
0
14
IOG6CR
IOG6CR
I/O group x counter register
0x48
0x20
read-only
0x00000000
CNT
Counter value
0
14
IOG7CR
IOG7CR
I/O group x counter register
0x4C
0x20
read-only
0x00000000
CNT
Counter value
0
14
IOG8CR
IOG8CR
I/O group x counter register
0x50
0x20
read-only
0x00000000
CNT
Counter value
0
14
IWDG
Independent watchdog
IWDG
0x40003000
0x0
0x400
registers
KR
KR
Key register
0x0
0x20
write-only
0x00000000
KEY
Key value (write only, read
0x0000)
0
16
PR
PR
Prescaler register
0x4
0x20
read-write
0x00000000
PR
Prescaler divider
0
3
RLR
RLR
Reload register
0x8
0x20
read-write
0x00000FFF
RL
Watchdog counter reload
value
0
12
SR
SR
Status register
0xC
0x20
read-only
0x00000000
WVU
Watchdog counter window value
update
2
1
RVU
Watchdog counter reload value
update
1
1
PVU
Watchdog prescaler value
update
0
1
WINR
WINR
Window register
0x10
0x20
read-write
0x00000FFF
WIN
Watchdog counter window
value
0
12
WWDG
System window watchdog
WWDG
0x40002C00
0x0
0x400
registers
WWDG
Window Watchdog interrupt
0
CR
CR
Control register
0x0
0x20
read-write
0x0000007F
WDGA
Activation bit
7
1
T
7-bit counter (MSB to LSB)
0
7
CFR
CFR
Configuration register
0x4
0x20
read-write
0x0000007F
EWI
Early wakeup interrupt
9
1
WDGTB
Timer base
7
2
W
7-bit window value
0
7
SR
SR
Status register
0x8
0x20
read-write
0x00000000
EWIF
Early wakeup interrupt
flag
0
1
COMP
Comparator
COMP
0x40010200
0x0
0x200
registers
COMP
COMP1 and COMP2 interrupts
64
COMP1_CSR
COMP1_CSR
Comparator 1 control and status
register
0x0
0x20
0x0
COMP1_EN
Comparator 1 enable bit
0
1
read-write
COMP1_PWRMODE
Power Mode of the comparator
1
2
2
read-write
COMP1_INMSEL
Comparator 1 Input Minus connection
configuration bit
4
3
read-write
COMP1_INPSEL
Comparator1 input plus selection
bit
7
1
read-write
COMP1_POLARITY
Comparator 1 polarity selection
bit
15
1
read-write
COMP1_HYST
Comparator 1 hysteresis selection
bits
16
2
read-write
COMP1_BLANKING
Comparator 1 blanking source selection
bits
18
3
read-write
COMP1_BRGEN
Scaler bridge enable
22
1
read-write
COMP1_SCALEN
Voltage scaler enable bit
23
1
read-write
COMP1_VALUE
Comparator 1 output status
bit
30
1
read-only
COMP1_LOCK
COMP1_CSR register lock
bit
31
1
write-only
COMP2_CSR
COMP2_CSR
Comparator 2 control and status
register
0x4
0x20
0x0
COMP2_EN
Comparator 2 enable bit
0
1
read-write
COMP2_PWRMODE
Power Mode of the comparator
2
2
2
read-write
COMP2_INMSEL
Comparator 2 Input Minus connection
configuration bit
4
3
read-write
COMP2_INPSEL
Comparator 2 Input Plus connection
configuration bit
7
1
read-write
COMP2_WINMODE
Windows mode selection bit
9
1
read-write
COMP2_POLARITY
Comparator 2 polarity selection
bit
15
1
read-write
COMP2_HYST
Comparator 2 hysteresis selection
bits
16
2
read-write
COMP2_BLANKING
Comparator 2 blanking source selection
bits
18
3
read-write
COMP2_BRGEN
Scaler bridge enable
22
1
read-write
COMP2_SCALEN
Voltage scaler enable bit
23
1
read-write
COMP2_VALUE
Comparator 2 output status
bit
30
1
read-only
COMP2_LOCK
COMP2_CSR register lock
bit
31
1
write-only
FIREWALL
Firewall
Firewall
0x40011C00
0x0
0x400
registers
CSSA
CSSA
Code segment start address
0x0
0x20
read-write
0x00000000
ADD
code segment start address
8
16
CSL
CSL
Code segment length
0x4
0x20
read-write
0x00000000
LENG
code segment length
8
14
NVDSSA
NVDSSA
Non-volatile data segment start
address
0x8
0x20
read-write
0x00000000
ADD
Non-volatile data segment start
address
8
16
NVDSL
NVDSL
Non-volatile data segment
length
0xC
0x20
read-write
0x00000000
LENG
Non-volatile data segment
length
8
14
VDSSA
VDSSA
Volatile data segment start
address
0x10
0x20
read-write
0x00000000
ADD
Volatile data segment start
address
6
10
VDSL
VDSL
Volatile data segment length
0x14
0x20
read-write
0x00000000
LENG
Non-volatile data segment
length
6
10
CR
CR
Configuration register
0x20
0x20
read-write
0x00000000
VDE
Volatile data execution
2
1
VDS
Volatile data shared
1
1
FPA
Firewall pre alarm
0
1
I2C1
Inter-integrated circuit
I2C
0x40005400
0x0
0x400
registers
I2C1_EV
I2C1 event interrupt
31
I2C1_ER
I2C1 error interrupt
32
CR1
CR1
Control register 1
0x0
0x20
read-write
0x00000000
PE
Peripheral enable
0
1
TXIE
TX Interrupt enable
1
1
RXIE
RX Interrupt enable
2
1
ADDRIE
Address match interrupt enable (slave
only)
3
1
NACKIE
Not acknowledge received interrupt
enable
4
1
STOPIE
STOP detection Interrupt
enable
5
1
TCIE
Transfer Complete interrupt
enable
6
1
ERRIE
Error interrupts enable
7
1
DNF
Digital noise filter
8
4
ANFOFF
Analog noise filter OFF
12
1
TXDMAEN
DMA transmission requests
enable
14
1
RXDMAEN
DMA reception requests
enable
15
1
SBC
Slave byte control
16
1
NOSTRETCH
Clock stretching disable
17
1
WUPEN
Wakeup from STOP enable
18
1
GCEN
General call enable
19
1
SMBHEN
SMBus Host address enable
20
1
SMBDEN
SMBus Device Default address
enable
21
1
ALERTEN
SMBUS alert enable
22
1
PECEN
PEC enable
23
1
CR2
CR2
Control register 2
0x4
0x20
read-write
0x00000000
PECBYTE
Packet error checking byte
26
1
AUTOEND
Automatic end mode (master
mode)
25
1
RELOAD
NBYTES reload mode
24
1
NBYTES
Number of bytes
16
8
NACK
NACK generation (slave
mode)
15
1
STOP
Stop generation (master
mode)
14
1
START
Start generation
13
1
HEAD10R
10-bit address header only read
direction (master receiver mode)
12
1
ADD10
10-bit addressing mode (master
mode)
11
1
RD_WRN
Transfer direction (master
mode)
10
1
SADD
Slave address bit (master
mode)
0
10
OAR1
OAR1
Own address register 1
0x8
0x20
read-write
0x00000000
OA1
Interface address
0
10
OA1MODE
Own Address 1 10-bit mode
10
1
OA1EN
Own Address 1 enable
15
1
OAR2
OAR2
Own address register 2
0xC
0x20
read-write
0x00000000
OA2
Interface address
1
7
OA2MSK
Own Address 2 masks
8
3
OA2EN
Own Address 2 enable
15
1
TIMINGR
TIMINGR
Timing register
0x10
0x20
read-write
0x00000000
SCLL
SCL low period (master
mode)
0
8
SCLH
SCL high period (master
mode)
8
8
SDADEL
Data hold time
16
4
SCLDEL
Data setup time
20
4
PRESC
Timing prescaler
28
4
TIMEOUTR
TIMEOUTR
Status register 1
0x14
0x20
read-write
0x00000000
TIMEOUTA
Bus timeout A
0
12
TIDLE
Idle clock timeout
detection
12
1
TIMOUTEN
Clock timeout enable
15
1
TIMEOUTB
Bus timeout B
16
12
TEXTEN
Extended clock timeout
enable
31
1
ISR
ISR
Interrupt and Status register
0x18
0x20
0x00000001
ADDCODE
Address match code (Slave
mode)
17
7
read-only
DIR
Transfer direction (Slave
mode)
16
1
read-only
BUSY
Bus busy
15
1
read-only
ALERT
SMBus alert
13
1
read-only
TIMEOUT
Timeout or t_low detection
flag
12
1
read-only
PECERR
PEC Error in reception
11
1
read-only
OVR
Overrun/Underrun (slave
mode)
10
1
read-only
ARLO
Arbitration lost
9
1
read-only
BERR
Bus error
8
1
read-only
TCR
Transfer Complete Reload
7
1
read-only
TC
Transfer Complete (master
mode)
6
1
read-only
STOPF
Stop detection flag
5
1
read-only
NACKF
Not acknowledge received
flag
4
1
read-only
ADDR
Address matched (slave
mode)
3
1
read-only
RXNE
Receive data register not empty
(receivers)
2
1
read-only
TXIS
Transmit interrupt status
(transmitters)
1
1
read-write
TXE
Transmit data register empty
(transmitters)
0
1
read-write
ICR
ICR
Interrupt clear register
0x1C
0x20
write-only
0x00000000
ALERTCF
Alert flag clear
13
1
TIMOUTCF
Timeout detection flag
clear
12
1
PECCF
PEC Error flag clear
11
1
OVRCF
Overrun/Underrun flag
clear
10
1
ARLOCF
Arbitration lost flag
clear
9
1
BERRCF
Bus error flag clear
8
1
STOPCF
Stop detection flag clear
5
1
NACKCF
Not Acknowledge flag clear
4
1
ADDRCF
Address Matched flag clear
3
1
PECR
PECR
PEC register
0x20
0x20
read-only
0x00000000
PEC
Packet error checking
register
0
8
RXDR
RXDR
Receive data register
0x24
0x20
read-only
0x00000000
RXDATA
8-bit receive data
0
8
TXDR
TXDR
Transmit data register
0x28
0x20
read-write
0x00000000
TXDATA
8-bit transmit data
0
8
I2C2
0x40005800
I2C2_EV
I2C2 event interrupt
33
I2C2_ER
I2C2 error interrupt
34
I2C3
0x40005C00
I2C3_EV
I2C3 event interrupt
72
I2C3_ER
I2C3 error interrupt
73
I2C4
0x40008400
I2C4_EV
I2C4 event interrupt
83
I2C4_ER
I2C4 error interrupt
84
FLASH
Flash
Flash
0x40022000
0x0
0x400
registers
FLASH
Flash global interrupt
4
ACR
ACR
Access control register
0x0
0x20
read-write
0x00000600
LATENCY
Latency
0
3
PRFTEN
Prefetch enable
8
1
ICEN
Instruction cache enable
9
1
DCEN
Data cache enable
10
1
ICRST
Instruction cache reset
11
1
DCRST
Data cache reset
12
1
RUN_PD
Flash Power-down mode during Low-power
run mode
13
1
SLEEP_PD
Flash Power-down mode during Low-power
sleep mode
14
1
PDKEYR
PDKEYR
Power down key register
0x4
0x20
write-only
0x00000000
PDKEYR
RUN_PD in FLASH_ACR key
0
32
KEYR
KEYR
Flash key register
0x8
0x20
write-only
0x00000000
KEYR
KEYR
0
32
OPTKEYR
OPTKEYR
Option byte key register
0xC
0x20
write-only
0x00000000
OPTKEYR
Option byte key
0
32
SR
SR
Status register
0x10
0x20
0x00000000
EOP
End of operation
0
1
read-write
OPERR
Operation error
1
1
read-write
PROGERR
Programming error
3
1
read-write
WRPERR
Write protected error
4
1
read-write
PGAERR
Programming alignment
error
5
1
read-write
SIZERR
Size error
6
1
read-write
PGSERR
Programming sequence error
7
1
read-write
MISERR
Fast programming data miss
error
8
1
read-write
FASTERR
Fast programming error
9
1
read-write
RDERR
PCROP read error
14
1
read-write
OPTVERR
Option validity error
15
1
read-write
BSY
Busy
16
1
read-only
CR
CR
Flash control register
0x14
0x20
read-write
0xC0000000
PG
Programming
0
1
PER
Page erase
1
1
MER1
Bank 1 Mass erase
2
1
PNB
Page number
3
8
BKER
Bank erase
11
1
MER2
Bank 2 Mass erase
15
1
START
Start
16
1
OPTSTRT
Options modification start
17
1
FSTPG
Fast programming
18
1
EOPIE
End of operation interrupt
enable
24
1
ERRIE
Error interrupt enable
25
1
RDERRIE
PCROP read error interrupt
enable
26
1
OBL_LAUNCH
Force the option byte
loading
27
1
OPTLOCK
Options Lock
30
1
LOCK
FLASH_CR Lock
31
1
ECCR
ECCR
Flash ECC register
0x18
0x20
0x00000000
ADDR_ECC
ECC fail address
0
19
read-only
BK_ECC
ECC fail bank
19
1
read-only
SYSF_ECC
System Flash ECC fail
20
1
read-only
ECCIE
ECC correction interrupt
enable
24
1
read-write
ECCC
ECC correction
30
1
read-write
ECCD
ECC detection
31
1
read-write
OPTR
OPTR
Flash option register
0x20
0x20
read-write
0xF0000000
RDP
Read protection level
0
8
BOR_LEV
BOR reset Level
8
3
nRST_STOP
nRST_STOP
12
1
nRST_STDBY
nRST_STDBY
13
1
IDWG_SW
Independent watchdog
selection
16
1
IWDG_STOP
Independent watchdog counter freeze in
Stop mode
17
1
IWDG_STDBY
Independent watchdog counter freeze in
Standby mode
18
1
WWDG_SW
Window watchdog selection
19
1
BFB2
Dual-bank boot
20
1
DUALBANK
Dual-Bank on 512 KB or 256 KB Flash
memory devices
21
1
nBOOT1
Boot configuration
23
1
SRAM2_PE
SRAM2 parity check enable
24
1
SRAM2_RST
SRAM2 Erase when system
reset
25
1
PCROP1SR
PCROP1SR
Flash Bank 1 PCROP Start address
register
0x24
0x20
read-write
0xFFFF0000
PCROP1_STRT
Bank 1 PCROP area start
offset
0
16
PCROP1ER
PCROP1ER
Flash Bank 1 PCROP End address
register
0x28
0x20
read-write
0x0FFF0000
PCROP1_END
Bank 1 PCROP area end
offset
0
16
PCROP_RDP
PCROP area preserved when RDP level
decreased
31
1
WRP1AR
WRP1AR
Flash Bank 1 WRP area A address
register
0x2C
0x20
read-write
0xFF00FF00
WRP1A_STRT
Bank 1 WRP first area start
offset
0
8
WRP1A_END
Bank 1 WRP first area A end
offset
16
8
WRP1BR
WRP1BR
Flash Bank 1 WRP area B address
register
0x30
0x20
read-write
0xFF00FF00
WRP1B_STRT
Bank 1 WRP second area B end
offset
16
8
WRP1B_END
Bank 1 WRP second area B start
offset
0
8
PCROP2SR
PCROP2SR
Flash Bank 2 PCROP Start address
register
0x44
0x20
read-write
0xFFFF0000
PCROP2_STRT
Bank 2 PCROP area start
offset
0
16
PCROP2ER
PCROP2ER
Flash Bank 2 PCROP End address
register
0x48
0x20
read-write
0xFFFF0000
PCROP2_END
Bank 2 PCROP area end
offset
0
16
WRP2AR
WRP2AR
Flash Bank 2 WRP area A address
register
0x4C
0x20
read-write
0xFF00FF00
WRP2A_STRT
Bank 2 WRP first area A start
offset
0
8
WRP2A_END
Bank 2 WRP first area A end
offset
16
8
WRP2BR
WRP2BR
Flash Bank 2 WRP area B address
register
0x50
0x20
read-write
0xFF00FF00
WRP2B_STRT
Bank 2 WRP second area B start
offset
0
8
WRP2B_END
Bank 2 WRP second area B end
offset
16
8
DBGMCU
Debug support
DBGMCU
0xE0042000
0x0
0x400
registers
IDCODE
IDCODE
MCU Device ID Code Register
0x0
0x20
read-only
0x0
DEV_ID
Device Identifier
0
16
REV_ID
Revision Identifier
16
16
CR
CR
Debug MCU Configuration
Register
0x4
0x20
read-write
0x0
DBG_SLEEP
Debug Sleep Mode
0
1
DBG_STOP
Debug Stop Mode
1
1
DBG_STANDBY
Debug Standby Mode
2
1
TRACE_IOEN
Trace pin assignment
control
5
1
TRACE_MODE
Trace pin assignment
control
6
2
APB1_FZR1
APB1_FZR1
APB Low Freeze Register 1
0x8
0x20
read-write
0x0
DBG_TIMER2_STOP
Debug Timer 2 stopped when Core is
halted
0
1
DBG_TIM3_STOP
TIM3 counter stopped when core is
halted
1
1
DBG_TIM4_STOP
TIM4 counter stopped when core is
halted
2
1
DBG_TIM5_STOP
TIM5 counter stopped when core is
halted
3
1
DBG_TIMER6_STOP
Debug Timer 6 stopped when Core is
halted
4
1
DBG_TIM7_STOP
TIM7 counter stopped when core is
halted
5
1
DBG_RTC_STOP
Debug RTC stopped when Core is
halted
10
1
DBG_WWDG_STOP
Debug Window Wachdog stopped when Core
is halted
11
1
DBG_IWDG_STOP
Debug Independent Wachdog stopped when
Core is halted
12
1
DBG_I2C1_STOP
I2C1 SMBUS timeout mode stopped when
core is halted
21
1
DBG_I2C2_STOP
I2C2 SMBUS timeout mode stopped when
core is halted
22
1
DBG_I2C3_STOP
I2C3 SMBUS timeout counter stopped when
core is halted
23
1
DBG_CAN_STOP
bxCAN stopped when core is
halted
25
1
DBG_LPTIMER_STOP
LPTIM1 counter stopped when core is
halted
31
1
APB1_FZR2
APB1_FZR2
APB Low Freeze Register 2
0xC
0x20
read-write
0x0
DBG_LPTIM2_STOP
LPTIM2 counter stopped when core is
halted
5
1
APB2_FZR
APB2_FZR
APB High Freeze Register
0x10
0x20
read-write
0x0
DBG_TIM1_STOP
TIM1 counter stopped when core is
halted
11
1
DBG_TIM8_STOP
TIM8 counter stopped when core is
halted
13
1
DBG_TIM15_STOP
TIM15 counter stopped when core is
halted
16
1
DBG_TIM16_STOP
TIM16 counter stopped when core is
halted
17
1
DBG_TIM17_STOP
TIM17 counter stopped when core is
halted
18
1
QUADSPI
QuadSPI interface
QUADSPI
0xA0001000
0x0
0x400
registers
QUADSPI
Quad SPI global interrupt
71
CR
CR
control register
0x0
0x20
read-write
0x00000000
PRESCALER
Clock prescaler
24
8
PMM
Polling match mode
23
1
APMS
Automatic poll mode stop
22
1
TOIE
TimeOut interrupt enable
20
1
SMIE
Status match interrupt
enable
19
1
FTIE
FIFO threshold interrupt
enable
18
1
TCIE
Transfer complete interrupt
enable
17
1
TEIE
Transfer error interrupt
enable
16
1
FTHRES
IFO threshold level
8
5
FSEL
FLASH memory selection
7
1
DFM
Dual-flash mode
6
1
SSHIFT
Sample shift
4
1
TCEN
Timeout counter enable
3
1
DMAEN
DMA enable
2
1
ABORT
Abort request
1
1
EN
Enable
0
1
DCR
DCR
device configuration register
0x4
0x20
read-write
0x00000000
FSIZE
FLASH memory size
16
5
CSHT
Chip select high time
8
3
CKMODE
Mode 0 / mode 3
0
1
SR
SR
status register
0x8
0x20
read-only
0x00000000
FLEVEL
FIFO level
8
7
BUSY
Busy
5
1
TOF
Timeout flag
4
1
SMF
Status match flag
3
1
FTF
FIFO threshold flag
2
1
TCF
Transfer complete flag
1
1
TEF
Transfer error flag
0
1
FCR
FCR
flag clear register
0xC
0x20
read-write
0x00000000
CTOF
Clear timeout flag
4
1
CSMF
Clear status match flag
3
1
CTCF
Clear transfer complete
flag
1
1
CTEF
Clear transfer error flag
0
1
DLR
DLR
data length register
0x10
0x20
read-write
0x00000000
DL
Data length
0
32
CCR
CCR
communication configuration
register
0x14
0x20
read-write
0x00000000
DDRM
Double data rate mode
31
1
DHHC
DDR hold half cycle
30
1
SIOO
Send instruction only once
mode
28
1
FMODE
Functional mode
26
2
DMODE
Data mode
24
2
DCYC
Number of dummy cycles
18
5
ABSIZE
Alternate bytes size
16
2
ABMODE
Alternate bytes mode
14
2
ADSIZE
Address size
12
2
ADMODE
Address mode
10
2
IMODE
Instruction mode
8
2
INSTRUCTION
Instruction
0
8
AR
AR
address register
0x18
0x20
read-write
0x00000000
ADDRESS
Address
0
32
ABR
ABR
ABR
0x1C
0x20
read-write
0x00000000
ALTERNATE
ALTERNATE
0
32
DR
DR
data register
0x20
0x20
read-write
0x00000000
DATA
Data
0
32
PSMKR
PSMKR
polling status mask register
0x24
0x20
read-write
0x00000000
MASK
Status mask
0
32
PSMAR
PSMAR
polling status match register
0x28
0x20
read-write
0x00000000
MATCH
Status match
0
32
PIR
PIR
polling interval register
0x2C
0x20
read-write
0x00000000
INTERVAL
Polling interval
0
16
LPTR
LPTR
low-power timeout register
0x30
0x20
read-write
0x00000000
TIMEOUT
Timeout period
0
16
RCC
Reset and clock control
RCC
0x40021000
0x0
0x400
registers
RCC
RCC global interrupt
5
CR
CR
Clock control register
0x0
0x20
0x00000063
PLLSAI2RDY
SAI2 PLL clock ready flag
29
1
read-only
PLLSAI2ON
SAI2 PLL enable
28
1
read-write
PLLSAI1RDY
SAI1 PLL clock ready flag
27
1
read-only
PLLSAI1ON
SAI1 PLL enable
26
1
read-write
PLLRDY
Main PLL clock ready flag
25
1
read-only
PLLON
Main PLL enable
24
1
read-write
CSSON
Clock security system
enable
19
1
write-only
HSEBYP
HSE crystal oscillator
bypass
18
1
read-write
HSERDY
HSE clock ready flag
17
1
read-only
HSEON
HSE clock enable
16
1
read-write
HSIASFS
HSI automatic start from
Stop
11
1
read-write
HSIRDY
HSI clock ready flag
10
1
read-only
HSIKERON
HSI always enable for peripheral
kernels
9
1
read-write
HSION
HSI clock enable
8
1
read-write
MSIRANGE
MSI clock ranges
4
4
read-write
MSIRGSEL
MSI clock range selection
3
1
write-only
MSIPLLEN
MSI clock PLL enable
2
1
read-write
MSIRDY
MSI clock ready flag
1
1
read-only
MSION
MSI clock enable
0
1
read-write
ICSCR
ICSCR
Internal clock sources calibration
register
0x4
0x20
0x10000000
HSITRIM
HSI clock trimming
24
7
read-write
HSICAL
HSI clock calibration
16
8
read-only
MSITRIM
MSI clock trimming
8
8
read-write
MSICAL
MSI clock calibration
0
8
read-only
CFGR
CFGR
Clock configuration register
0x8
0x20
0x00000000
MCOPRE
Microcontroller clock output
prescaler
28
3
read-only
MCOSEL
Microcontroller clock
output
24
3
read-write
STOPWUCK
Wakeup from Stop and CSS backup clock
selection
15
1
read-write
PPRE2
APB high-speed prescaler
(APB2)
11
3
read-write
PPRE1
PB low-speed prescaler
(APB1)
8
3
read-write
HPRE
AHB prescaler
4
4
read-write
SWS
System clock switch status
2
2
read-only
SW
System clock switch
0
2
read-write
PLLCFGR
PLLCFGR
PLL configuration register
0xC
0x20
read-write
0x00001000
PLLR
Main PLL division factor for PLLCLK
(system clock)
25
2
PLLREN
Main PLL PLLCLK output
enable
24
1
PLLQ
Main PLL division factor for
PLLUSB1CLK(48 MHz clock)
21
2
PLLQEN
Main PLL PLLUSB1CLK output
enable
20
1
PLLP
Main PLL division factor for PLLSAI3CLK
(SAI1 and SAI2 clock)
17
1
PLLPEN
Main PLL PLLSAI3CLK output
enable
16
1
PLLN
Main PLL multiplication factor for
VCO
8
7
PLLM
Division factor for the main PLL and
audio PLL (PLLSAI1 and PLLSAI2) input
clock
4
3
PLLSRC
Main PLL, PLLSAI1 and PLLSAI2 entry
clock source
0
2
PLLPDIV
Main PLL division factor for
PLLSAI2CLK
27
5
PLLSAI1CFGR
PLLSAI1CFGR
PLLSAI1 configuration register
0x10
0x20
read-write
0x00001000
PLLSAI1R
PLLSAI1 division factor for PLLADC1CLK
(ADC clock)
25
2
PLLSAI1REN
PLLSAI1 PLLADC1CLK output
enable
24
1
PLLSAI1Q
SAI1PLL division factor for PLLUSB2CLK
(48 MHz clock)
21
2
PLLSAI1QEN
SAI1PLL PLLUSB2CLK output
enable
20
1
PLLSAI1P
SAI1PLL division factor for PLLSAI1CLK
(SAI1 or SAI2 clock)
17
1
PLLSAI1PEN
SAI1PLL PLLSAI1CLK output
enable
16
1
PLLSAI1N
SAI1PLL multiplication factor for
VCO
8
7
PLLSAI1PDIV
PLLSAI1 division factor for
PLLSAI1CLK
27
5
PLLSAI2CFGR
PLLSAI2CFGR
PLLSAI2 configuration register
0x14
0x20
read-write
0x00001000
PLLSAI2R
PLLSAI2 division factor for PLLADC2CLK
(ADC clock)
25
2
PLLSAI2REN
PLLSAI2 PLLADC2CLK output
enable
24
1
PLLSAI2P
SAI1PLL division factor for PLLSAI2CLK
(SAI1 or SAI2 clock)
17
1
PLLSAI2PEN
SAI2PLL PLLSAI2CLK output
enable
16
1
PLLSAI2N
SAI2PLL multiplication factor for
VCO
8
7
PLLSAI2PDIV
PLLSAI2 division factor for
PLLSAI2CLK
27
5
CIER
CIER
Clock interrupt enable
register
0x18
0x20
read-write
0x00000000
LSECSSIE
LSE clock security system interrupt
enable
9
1
PLLSAI2RDYIE
PLLSAI2 ready interrupt
enable
7
1
PLLSAI1RDYIE
PLLSAI1 ready interrupt
enable
6
1
PLLRDYIE
PLL ready interrupt enable
5
1
HSERDYIE
HSE ready interrupt enable
4
1
HSIRDYIE
HSI ready interrupt enable
3
1
MSIRDYIE
MSI ready interrupt enable
2
1
LSERDYIE
LSE ready interrupt enable
1
1
LSIRDYIE
LSI ready interrupt enable
0
1
HSI48RDYIE
HSI48 ready interrupt
enable
10
1
CIFR
CIFR
Clock interrupt flag register
0x1C
0x20
read-only
0x00000000
LSECSSF
LSE Clock security system interrupt
flag
9
1
CSSF
Clock security system interrupt
flag
8
1
PLLSAI2RDYF
PLLSAI2 ready interrupt
flag
7
1
PLLSAI1RDYF
PLLSAI1 ready interrupt
flag
6
1
PLLRDYF
PLL ready interrupt flag
5
1
HSERDYF
HSE ready interrupt flag
4
1
HSIRDYF
HSI ready interrupt flag
3
1
MSIRDYF
MSI ready interrupt flag
2
1
LSERDYF
LSE ready interrupt flag
1
1
LSIRDYF
LSI ready interrupt flag
0
1
HSI48RDYF
HSI48 ready interrupt flag
10
1
CICR
CICR
Clock interrupt clear register
0x20
0x20
write-only
0x00000000
LSECSSC
LSE Clock security system interrupt
clear
9
1
CSSC
Clock security system interrupt
clear
8
1
PLLSAI2RDYC
PLLSAI2 ready interrupt
clear
7
1
PLLSAI1RDYC
PLLSAI1 ready interrupt
clear
6
1
PLLRDYC
PLL ready interrupt clear
5
1
HSERDYC
HSE ready interrupt clear
4
1
HSIRDYC
HSI ready interrupt clear
3
1
MSIRDYC
MSI ready interrupt clear
2
1
LSERDYC
LSE ready interrupt clear
1
1
LSIRDYC
LSI ready interrupt clear
0
1
HSI48RDYC
HSI48 oscillator ready interrupt
clear
10
1
AHB1RSTR
AHB1RSTR
AHB1 peripheral reset register
0x28
0x20
read-write
0x00000000
TSCRST
Touch Sensing Controller
reset
16
1
CRCRST
CRC reset
12
1
FLASHRST
Flash memory interface
reset
8
1
DMA2RST
DMA2 reset
1
1
DMA1RST
DMA1 reset
0
1
DMA2DRST
DMA2D reset
17
1
AHB2RSTR
AHB2RSTR
AHB2 peripheral reset register
0x2C
0x20
read-write
0x00000000
RNGRST
Random number generator
reset
18
1
AESRST
AES hardware accelerator
reset
16
1
ADCRST
ADC reset
13
1
OTGFSRST
USB OTG FS reset
12
1
GPIOHRST
IO port H reset
7
1
GPIOGRST
IO port G reset
6
1
GPIOFRST
IO port F reset
5
1
GPIOERST
IO port E reset
4
1
GPIODRST
IO port D reset
3
1
GPIOCRST
IO port C reset
2
1
GPIOBRST
IO port B reset
1
1
GPIOARST
IO port A reset
0
1
GPIOIRST
IO port I reset
8
1
DCMIRST
Digital Camera Interface
reset
14
1
HASH1RST
Hash reset
17
1
AHB3RSTR
AHB3RSTR
AHB3 peripheral reset register
0x30
0x20
read-write
0x00000000
QSPIRST
Quad SPI memory interface
reset
8
1
FMCRST
Flexible memory controller
reset
0
1
APB1RSTR1
APB1RSTR1
APB1 peripheral reset register
1
0x38
0x20
read-write
0x00000000
LPTIM1RST
Low Power Timer 1 reset
31
1
OPAMPRST
OPAMP interface reset
30
1
DAC1RST
DAC1 interface reset
29
1
PWRRST
Power interface reset
28
1
CAN1RST
CAN1 reset
25
1
I2C3RST
I2C3 reset
23
1
I2C2RST
I2C2 reset
22
1
I2C1RST
I2C1 reset
21
1
UART5RST
UART5 reset
20
1
UART4RST
UART4 reset
19
1
USART3RST
USART3 reset
18
1
USART2RST
USART2 reset
17
1
SPI3RST
SPI3 reset
15
1
SPI2RST
SPI2 reset
14
1
LCDRST
LCD interface reset
9
1
TIM7RST
TIM7 timer reset
5
1
TIM6RST
TIM6 timer reset
4
1
TIM5RST
TIM5 timer reset
3
1
TIM4RST
TIM3 timer reset
2
1
TIM3RST
TIM3 timer reset
1
1
TIM2RST
TIM2 timer reset
0
1
CRSRST
CRS reset
24
1
CAN2RST
CAN2 reset
26
1
APB1RSTR2
APB1RSTR2
APB1 peripheral reset register
2
0x3C
0x20
read-write
0x00000000
LPTIM2RST
Low-power timer 2 reset
5
1
SWPMI1RST
Single wire protocol reset
2
1
LPUART1RST
Low-power UART 1 reset
0
1
I2C4RST
I2C4 reset
1
1
APB2RSTR
APB2RSTR
APB2 peripheral reset register
0x40
0x20
read-write
0x00000000
DFSDMRST
Digital filters for sigma-delata
modulators (DFSDM) reset
24
1
SAI2RST
Serial audio interface 2 (SAI2)
reset
22
1
SAI1RST
Serial audio interface 1 (SAI1)
reset
21
1
TIM17RST
TIM17 timer reset
18
1
TIM16RST
TIM16 timer reset
17
1
TIM15RST
TIM15 timer reset
16
1
USART1RST
USART1 reset
14
1
TIM8RST
TIM8 timer reset
13
1
SPI1RST
SPI1 reset
12
1
TIM1RST
TIM1 timer reset
11
1
SDMMCRST
SDMMC reset
10
1
SYSCFGRST
System configuration (SYSCFG)
reset
0
1
AHB1ENR
AHB1ENR
AHB1 peripheral clock enable
register
0x48
0x20
read-write
0x00000100
TSCEN
Touch Sensing Controller clock
enable
16
1
CRCEN
CRC clock enable
12
1
FLASHEN
Flash memory interface clock
enable
8
1
DMA2EN
DMA2 clock enable
1
1
DMA1EN
DMA1 clock enable
0
1
DMA2DEN
DMA2D clock enable
17
1
AHB2ENR
AHB2ENR
AHB2 peripheral clock enable
register
0x4C
0x20
read-write
0x00000000
RNGEN
Random Number Generator clock
enable
18
1
AESEN
AES accelerator clock
enable
16
1
ADCEN
ADC clock enable
13
1
OTGFSEN
OTG full speed clock
enable
12
1
GPIOHEN
IO port H clock enable
7
1
GPIOGEN
IO port G clock enable
6
1
GPIOFEN
IO port F clock enable
5
1
GPIOEEN
IO port E clock enable
4
1
GPIODEN
IO port D clock enable
3
1
GPIOCEN
IO port C clock enable
2
1
GPIOBEN
IO port B clock enable
1
1
GPIOAEN
IO port A clock enable
0
1
GPIOIEN
IO port I clock enable
8
1
DCMIEN
DCMI clock enable
14
1
HASH1EN
HASH clock enable
17
1
AHB3ENR
AHB3ENR
AHB3 peripheral clock enable
register
0x50
0x20
read-write
0x00000000
QSPIEN
QSPIEN
8
1
FMCEN
Flexible memory controller clock
enable
0
1
APB1ENR1
APB1ENR1
APB1ENR1
0x58
0x20
read-write
0x00000000
LPTIM1EN
Low power timer 1 clock
enable
31
1
OPAMPEN
OPAMP interface clock
enable
30
1
DAC1EN
DAC1 interface clock
enable
29
1
PWREN
Power interface clock
enable
28
1
CAN1EN
CAN1 clock enable
25
1
I2C3EN
I2C3 clock enable
23
1
I2C2EN
I2C2 clock enable
22
1
I2C1EN
I2C1 clock enable
21
1
UART5EN
UART5 clock enable
20
1
UART4EN
UART4 clock enable
19
1
USART3EN
USART3 clock enable
18
1
USART2EN
USART2 clock enable
17
1
SP3EN
SPI3 clock enable
15
1
SPI2EN
SPI2 clock enable
14
1
WWDGEN
Window watchdog clock
enable
11
1
LCDEN
LCD clock enable
9
1
TIM7EN
TIM7 timer clock enable
5
1
TIM6EN
TIM6 timer clock enable
4
1
TIM5EN
TIM5 timer clock enable
3
1
TIM4EN
TIM4 timer clock enable
2
1
TIM3EN
TIM3 timer clock enable
1
1
TIM2EN
TIM2 timer clock enable
0
1
RTCAPBEN
RTC APB clock enable
10
1
CRSEN
Clock Recovery System clock
enable
24
1
CAN2EN
CAN2 clock enable
26
1
APB1ENR2
APB1ENR2
APB1 peripheral clock enable register
2
0x5C
0x20
read-write
0x00000000
LPTIM2EN
LPTIM2EN
5
1
SWPMI1EN
Single wire protocol clock
enable
2
1
LPUART1EN
Low power UART 1 clock
enable
0
1
I2C4EN
I2C4 clock enable
1
1
APB2ENR
APB2ENR
APB2ENR
0x60
0x20
read-write
0x00000000
DFSDMEN
DFSDM timer clock enable
24
1
SAI2EN
SAI2 clock enable
22
1
SAI1EN
SAI1 clock enable
21
1
TIM17EN
TIM17 timer clock enable
18
1
TIM16EN
TIM16 timer clock enable
17
1
TIM15EN
TIM15 timer clock enable
16
1
USART1EN
USART1clock enable
14
1
TIM8EN
TIM8 timer clock enable
13
1
SPI1EN
SPI1 clock enable
12
1
TIM1EN
TIM1 timer clock enable
11
1
SDMMCEN
SDMMC clock enable
10
1
FIREWALLEN
Firewall clock enable
7
1
SYSCFGEN
SYSCFG clock enable
0
1
AHB1SMENR
AHB1SMENR
AHB1 peripheral clocks enable in Sleep and
Stop modes register
0x68
0x20
read-write
0x00011303
TSCSMEN
Touch Sensing Controller clocks enable
during Sleep and Stop modes
16
1
CRCSMEN
CRCSMEN
12
1
SRAM1SMEN
SRAM1 interface clocks enable during
Sleep and Stop modes
9
1
FLASHSMEN
Flash memory interface clocks enable
during Sleep and Stop modes
8
1
DMA2SMEN
DMA2 clocks enable during Sleep and Stop
modes
1
1
DMA1SMEN
DMA1 clocks enable during Sleep and Stop
modes
0
1
DMA2DSMEN
DMA2D clock enable during Sleep and Stop
modes
17
1
AHB2SMENR
AHB2SMENR
AHB2 peripheral clocks enable in Sleep and
Stop modes register
0x6C
0x20
read-write
0x000532FF
RNGSMEN
Random Number Generator clocks enable
during Sleep and Stop modes
18
1
AESSMEN
AES accelerator clocks enable during
Sleep and Stop modes
16
1
ADCFSSMEN
ADC clocks enable during Sleep and Stop
modes
13
1
OTGFSSMEN
OTG full speed clocks enable during
Sleep and Stop modes
12
1
SRAM2SMEN
SRAM2 interface clocks enable during
Sleep and Stop modes
9
1
GPIOHSMEN
IO port H clocks enable during Sleep and
Stop modes
7
1
GPIOGSMEN
IO port G clocks enable during Sleep and
Stop modes
6
1
GPIOFSMEN
IO port F clocks enable during Sleep and
Stop modes
5
1
GPIOESMEN
IO port E clocks enable during Sleep and
Stop modes
4
1
GPIODSMEN
IO port D clocks enable during Sleep and
Stop modes
3
1
GPIOCSMEN
IO port C clocks enable during Sleep and
Stop modes
2
1
GPIOBSMEN
IO port B clocks enable during Sleep and
Stop modes
1
1
GPIOASMEN
IO port A clocks enable during Sleep and
Stop modes
0
1
GPIOISMEN
IO port I clocks enable during Sleep and
Stop modes
8
1
DCMISMEN
DCMI clock enable during Sleep and Stop
modes
14
1
HASH1SMEN
HASH clock enable during Sleep and Stop
modes
17
1
AHB3SMENR
AHB3SMENR
AHB3 peripheral clocks enable in Sleep and
Stop modes register
0x70
0x20
read-write
0x000000101
QSPISMEN
QSPISMEN
8
1
FMCSMEN
Flexible memory controller clocks enable
during Sleep and Stop modes
0
1
APB1SMENR1
APB1SMENR1
APB1SMENR1
0x78
0x20
read-write
0xF2FECA3F
LPTIM1SMEN
Low power timer 1 clocks enable during
Sleep and Stop modes
31
1
OPAMPSMEN
OPAMP interface clocks enable during
Sleep and Stop modes
30
1
DAC1SMEN
DAC1 interface clocks enable during
Sleep and Stop modes
29
1
PWRSMEN
Power interface clocks enable during
Sleep and Stop modes
28
1
CAN1SMEN
CAN1 clocks enable during Sleep and Stop
modes
25
1
I2C3SMEN
I2C3 clocks enable during Sleep and Stop
modes
23
1
I2C2SMEN
I2C2 clocks enable during Sleep and Stop
modes
22
1
I2C1SMEN
I2C1 clocks enable during Sleep and Stop
modes
21
1
UART5SMEN
UART5 clocks enable during Sleep and
Stop modes
20
1
UART4SMEN
UART4 clocks enable during Sleep and
Stop modes
19
1
USART3SMEN
USART3 clocks enable during Sleep and
Stop modes
18
1
USART2SMEN
USART2 clocks enable during Sleep and
Stop modes
17
1
SP3SMEN
SPI3 clocks enable during Sleep and Stop
modes
15
1
SPI2SMEN
SPI2 clocks enable during Sleep and Stop
modes
14
1
WWDGSMEN
Window watchdog clocks enable during
Sleep and Stop modes
11
1
LCDSMEN
LCD clocks enable during Sleep and Stop
modes
9
1
TIM7SMEN
TIM7 timer clocks enable during Sleep
and Stop modes
5
1
TIM6SMEN
TIM6 timer clocks enable during Sleep
and Stop modes
4
1
TIM5SMEN
TIM5 timer clocks enable during Sleep
and Stop modes
3
1
TIM4SMEN
TIM4 timer clocks enable during Sleep
and Stop modes
2
1
TIM3SMEN
TIM3 timer clocks enable during Sleep
and Stop modes
1
1
TIM2SMEN
TIM2 timer clocks enable during Sleep
and Stop modes
0
1
RTCAPBSMEN
RTC APB clock enable during Sleep and
Stop modes
10
1
CAN2SMEN
CAN2 clocks enable during Sleep and Stop
modes
26
1
APB1SMENR2
APB1SMENR2
APB1 peripheral clocks enable in Sleep and
Stop modes register 2
0x7C
0x20
read-write
0x000000025
LPTIM2SMEN
LPTIM2SMEN
5
1
SWPMI1SMEN
Single wire protocol clocks enable
during Sleep and Stop modes
2
1
LPUART1SMEN
Low power UART 1 clocks enable during
Sleep and Stop modes
0
1
I2C4SMEN
I2C4 clocks enable during Sleep and Stop
modes
1
1
APB2SMENR
APB2SMENR
APB2SMENR
0x80
0x20
read-write
0x01677C01
DFSDMSMEN
DFSDM timer clocks enable during Sleep
and Stop modes
24
1
SAI2SMEN
SAI2 clocks enable during Sleep and Stop
modes
22
1
SAI1SMEN
SAI1 clocks enable during Sleep and Stop
modes
21
1
TIM17SMEN
TIM17 timer clocks enable during Sleep
and Stop modes
18
1
TIM16SMEN
TIM16 timer clocks enable during Sleep
and Stop modes
17
1
TIM15SMEN
TIM15 timer clocks enable during Sleep
and Stop modes
16
1
USART1SMEN
USART1clocks enable during Sleep and
Stop modes
14
1
TIM8SMEN
TIM8 timer clocks enable during Sleep
and Stop modes
13
1
SPI1SMEN
SPI1 clocks enable during Sleep and Stop
modes
12
1
TIM1SMEN
TIM1 timer clocks enable during Sleep
and Stop modes
11
1
SDMMCSMEN
SDMMC clocks enable during Sleep and
Stop modes
10
1
SYSCFGSMEN
SYSCFG clocks enable during Sleep and
Stop modes
0
1
CCIPR
CCIPR
CCIPR
0x88
0x20
read-write
0x00000000
DFSDMSEL
DFSDM clock source
selection
31
1
SWPMI1SEL
SWPMI1 clock source
selection
30
1
ADCSEL
ADCs clock source
selection
28
2
CLK48SEL
48 MHz clock source
selection
26
2
SAI2SEL
SAI2 clock source
selection
24
2
SAI1SEL
SAI1 clock source
selection
22
2
LPTIM2SEL
Low power timer 2 clock source
selection
20
2
LPTIM1SEL
Low power timer 1 clock source
selection
18
2
I2C3SEL
I2C3 clock source
selection
16
2
I2C2SEL
I2C2 clock source
selection
14
2
I2C1SEL
I2C1 clock source
selection
12
2
LPUART1SEL
LPUART1 clock source
selection
10
2
UART5SEL
UART5 clock source
selection
8
2
UART4SEL
UART4 clock source
selection
6
2
USART3SEL
USART3 clock source
selection
4
2
USART2SEL
USART2 clock source
selection
2
2
USART1SEL
USART1 clock source
selection
0
2
BDCR
BDCR
BDCR
0x90
0x20
0x00000000
LSCOSEL
Low speed clock output
selection
25
1
read-write
LSCOEN
Low speed clock output
enable
24
1
read-write
BDRST
Backup domain software
reset
16
1
read-write
RTCEN
RTC clock enable
15
1
read-write
RTCSEL
RTC clock source selection
8
2
read-write
LSECSSD
LSECSSD
6
1
read-only
LSECSSON
LSECSSON
5
1
read-write
LSEDRV
SE oscillator drive
capability
3
2
read-write
LSEBYP
LSE oscillator bypass
2
1
read-write
LSERDY
LSE oscillator ready
1
1
read-only
LSEON
LSE oscillator enable
0
1
read-write
CSR
CSR
CSR
0x94
0x20
0x0C000600
LPWRSTF
Low-power reset flag
31
1
read-only
WWDGRSTF
Window watchdog reset flag
30
1
read-only
IWDGRSTF
Independent window watchdog reset
flag
29
1
read-only
SFTRSTF
Software reset flag
28
1
read-only
BORRSTF
BOR flag
27
1
read-only
PINRSTF
Pin reset flag
26
1
read-only
OBLRSTF
Option byte loader reset
flag
25
1
read-only
FIREWALLRSTF
Firewall reset flag
24
1
read-only
RMVF
Remove reset flag
23
1
read-write
MSISRANGE
SI range after Standby
mode
8
4
read-write
LSIRDY
LSI oscillator ready
1
1
read-only
LSION
LSI oscillator enable
0
1
read-write
PWR
Power control
PWR
0x40007000
0x0
0x400
registers
CR1
CR1
Power control register 1
0x0
0x20
read-write
0x00000200
LPR
Low-power run
14
1
VOS
Voltage scaling range
selection
9
2
DBP
Disable backup domain write
protection
8
1
LPMS
Low-power mode selection
0
3
CR2
CR2
Power control register 2
0x4
0x20
read-write
0x00000000
USV
VDDUSB USB supply valid
10
1
IOSV
VDDIO2 Independent I/Os supply
valid
9
1
PVME4
Peripheral voltage monitoring 4 enable:
VDDA vs. 2.2V
7
1
PVME3
Peripheral voltage monitoring 3 enable:
VDDA vs. 1.62V
6
1
PVME2
Peripheral voltage monitoring 2 enable:
VDDIO2 vs. 0.9V
5
1
PVME1
Peripheral voltage monitoring 1 enable:
VDDUSB vs. 1.2V
4
1
PLS
Power voltage detector level
selection
1
3
PVDE
Power voltage detector
enable
0
1
CR3
CR3
Power control register 3
0x8
0x20
read-write
0X00008000
EWF
Enable internal wakeup
line
15
1
APC
Apply pull-up and pull-down
configuration
10
1
RRS
SRAM2 retention in Standby
mode
8
1
EWUP5
Enable Wakeup pin WKUP5
4
1
EWUP4
Enable Wakeup pin WKUP4
3
1
EWUP3
Enable Wakeup pin WKUP3
2
1
EWUP2
Enable Wakeup pin WKUP2
1
1
EWUP1
Enable Wakeup pin WKUP1
0
1
CR4
CR4
Power control register 4
0xC
0x20
read-write
0x00000000
VBRS
VBAT battery charging resistor
selection
9
1
VBE
VBAT battery charging
enable
8
1
WP5
Wakeup pin WKUP5 polarity
4
1
WP4
Wakeup pin WKUP4 polarity
3
1
WP3
Wakeup pin WKUP3 polarity
2
1
WP2
Wakeup pin WKUP2 polarity
1
1
WP1
Wakeup pin WKUP1 polarity
0
1
SR1
SR1
Power status register 1
0x10
0x20
read-only
0x00000000
WUFI
Wakeup flag internal
15
1
CSBF
Standby flag
8
1
CWUF5
Wakeup flag 5
4
1
CWUF4
Wakeup flag 4
3
1
CWUF3
Wakeup flag 3
2
1
CWUF2
Wakeup flag 2
1
1
CWUF1
Wakeup flag 1
0
1
SR2
SR2
Power status register 2
0x14
0x20
read-only
0x00000000
PVMO4
Peripheral voltage monitoring output:
VDDA vs. 2.2 V
15
1
PVMO3
Peripheral voltage monitoring output:
VDDA vs. 1.62 V
14
1
PVMO2
Peripheral voltage monitoring output:
VDDIO2 vs. 0.9 V
13
1
PVMO1
Peripheral voltage monitoring output:
VDDUSB vs. 1.2 V
12
1
PVDO
Power voltage detector
output
11
1
VOSF
Voltage scaling flag
10
1
REGLPF
Low-power regulator flag
9
1
REGLPS
Low-power regulator
started
8
1
SCR
SCR
Power status clear register
0x18
0x20
write-only
0x00000000
SBF
Clear standby flag
8
1
WUF5
Clear wakeup flag 5
4
1
WUF4
Clear wakeup flag 4
3
1
WUF3
Clear wakeup flag 3
2
1
WUF2
Clear wakeup flag 2
1
1
WUF1
Clear wakeup flag 1
0
1
PUCRA
PUCRA
Power Port A pull-up control
register
0x20
0x20
read-write
0x00000000
PU15
Port A pull-up bit y
(y=0..15)
15
1
PU14
Port A pull-up bit y
(y=0..15)
14
1
PU13
Port A pull-up bit y
(y=0..15)
13
1
PU12
Port A pull-up bit y
(y=0..15)
12
1
PU11
Port A pull-up bit y
(y=0..15)
11
1
PU10
Port A pull-up bit y
(y=0..15)
10
1
PU9
Port A pull-up bit y
(y=0..15)
9
1
PU8
Port A pull-up bit y
(y=0..15)
8
1
PU7
Port A pull-up bit y
(y=0..15)
7
1
PU6
Port A pull-up bit y
(y=0..15)
6
1
PU5
Port A pull-up bit y
(y=0..15)
5
1
PU4
Port A pull-up bit y
(y=0..15)
4
1
PU3
Port A pull-up bit y
(y=0..15)
3
1
PU2
Port A pull-up bit y
(y=0..15)
2
1
PU1
Port A pull-up bit y
(y=0..15)
1
1
PU0
Port A pull-up bit y
(y=0..15)
0
1
PDCRA
PDCRA
Power Port A pull-down control
register
0x24
0x20
read-write
0x00000000
PD15
Port A pull-down bit y
(y=0..15)
15
1
PD14
Port A pull-down bit y
(y=0..15)
14
1
PD13
Port A pull-down bit y
(y=0..15)
13
1
PD12
Port A pull-down bit y
(y=0..15)
12
1
PD11
Port A pull-down bit y
(y=0..15)
11
1
PD10
Port A pull-down bit y
(y=0..15)
10
1
PD9
Port A pull-down bit y
(y=0..15)
9
1
PD8
Port A pull-down bit y
(y=0..15)
8
1
PD7
Port A pull-down bit y
(y=0..15)
7
1
PD6
Port A pull-down bit y
(y=0..15)
6
1
PD5
Port A pull-down bit y
(y=0..15)
5
1
PD4
Port A pull-down bit y
(y=0..15)
4
1
PD3
Port A pull-down bit y
(y=0..15)
3
1
PD2
Port A pull-down bit y
(y=0..15)
2
1
PD1
Port A pull-down bit y
(y=0..15)
1
1
PD0
Port A pull-down bit y
(y=0..15)
0
1
PUCRB
PUCRB
Power Port B pull-up control
register
0x28
0x20
read-write
0x00000000
PU15
Port B pull-up bit y
(y=0..15)
15
1
PU14
Port B pull-up bit y
(y=0..15)
14
1
PU13
Port B pull-up bit y
(y=0..15)
13
1
PU12
Port B pull-up bit y
(y=0..15)
12
1
PU11
Port B pull-up bit y
(y=0..15)
11
1
PU10
Port B pull-up bit y
(y=0..15)
10
1
PU9
Port B pull-up bit y
(y=0..15)
9
1
PU8
Port B pull-up bit y
(y=0..15)
8
1
PU7
Port B pull-up bit y
(y=0..15)
7
1
PU6
Port B pull-up bit y
(y=0..15)
6
1
PU5
Port B pull-up bit y
(y=0..15)
5
1
PU4
Port B pull-up bit y
(y=0..15)
4
1
PU3
Port B pull-up bit y
(y=0..15)
3
1
PU2
Port B pull-up bit y
(y=0..15)
2
1
PU1
Port B pull-up bit y
(y=0..15)
1
1
PU0
Port B pull-up bit y
(y=0..15)
0
1
PDCRB
PDCRB
Power Port B pull-down control
register
0x2C
0x20
read-write
0x00000000
PD15
Port B pull-down bit y
(y=0..15)
15
1
PD14
Port B pull-down bit y
(y=0..15)
14
1
PD13
Port B pull-down bit y
(y=0..15)
13
1
PD12
Port B pull-down bit y
(y=0..15)
12
1
PD11
Port B pull-down bit y
(y=0..15)
11
1
PD10
Port B pull-down bit y
(y=0..15)
10
1
PD9
Port B pull-down bit y
(y=0..15)
9
1
PD8
Port B pull-down bit y
(y=0..15)
8
1
PD7
Port B pull-down bit y
(y=0..15)
7
1
PD6
Port B pull-down bit y
(y=0..15)
6
1
PD5
Port B pull-down bit y
(y=0..15)
5
1
PD4
Port B pull-down bit y
(y=0..15)
4
1
PD3
Port B pull-down bit y
(y=0..15)
3
1
PD2
Port B pull-down bit y
(y=0..15)
2
1
PD1
Port B pull-down bit y
(y=0..15)
1
1
PD0
Port B pull-down bit y
(y=0..15)
0
1
PUCRC
PUCRC
Power Port C pull-up control
register
0x30
0x20
read-write
0x00000000
PU15
Port C pull-up bit y
(y=0..15)
15
1
PU14
Port C pull-up bit y
(y=0..15)
14
1
PU13
Port C pull-up bit y
(y=0..15)
13
1
PU12
Port C pull-up bit y
(y=0..15)
12
1
PU11
Port C pull-up bit y
(y=0..15)
11
1
PU10
Port C pull-up bit y
(y=0..15)
10
1
PU9
Port C pull-up bit y
(y=0..15)
9
1
PU8
Port C pull-up bit y
(y=0..15)
8
1
PU7
Port C pull-up bit y
(y=0..15)
7
1
PU6
Port C pull-up bit y
(y=0..15)
6
1
PU5
Port C pull-up bit y
(y=0..15)
5
1
PU4
Port C pull-up bit y
(y=0..15)
4
1
PU3
Port C pull-up bit y
(y=0..15)
3
1
PU2
Port C pull-up bit y
(y=0..15)
2
1
PU1
Port C pull-up bit y
(y=0..15)
1
1
PU0
Port C pull-up bit y
(y=0..15)
0
1
PDCRC
PDCRC
Power Port C pull-down control
register
0x34
0x20
read-write
0x00000000
PD15
Port C pull-down bit y
(y=0..15)
15
1
PD14
Port C pull-down bit y
(y=0..15)
14
1
PD13
Port C pull-down bit y
(y=0..15)
13
1
PD12
Port C pull-down bit y
(y=0..15)
12
1
PD11
Port C pull-down bit y
(y=0..15)
11
1
PD10
Port C pull-down bit y
(y=0..15)
10
1
PD9
Port C pull-down bit y
(y=0..15)
9
1
PD8
Port C pull-down bit y
(y=0..15)
8
1
PD7
Port C pull-down bit y
(y=0..15)
7
1
PD6
Port C pull-down bit y
(y=0..15)
6
1
PD5
Port C pull-down bit y
(y=0..15)
5
1
PD4
Port C pull-down bit y
(y=0..15)
4
1
PD3
Port C pull-down bit y
(y=0..15)
3
1
PD2
Port C pull-down bit y
(y=0..15)
2
1
PD1
Port C pull-down bit y
(y=0..15)
1
1
PD0
Port C pull-down bit y
(y=0..15)
0
1
PUCRD
PUCRD
Power Port D pull-up control
register
0x38
0x20
read-write
0x00000000
PU15
Port D pull-up bit y
(y=0..15)
15
1
PU14
Port D pull-up bit y
(y=0..15)
14
1
PU13
Port D pull-up bit y
(y=0..15)
13
1
PU12
Port D pull-up bit y
(y=0..15)
12
1
PU11
Port D pull-up bit y
(y=0..15)
11
1
PU10
Port D pull-up bit y
(y=0..15)
10
1
PU9
Port D pull-up bit y
(y=0..15)
9
1
PU8
Port D pull-up bit y
(y=0..15)
8
1
PU7
Port D pull-up bit y
(y=0..15)
7
1
PU6
Port D pull-up bit y
(y=0..15)
6
1
PU5
Port D pull-up bit y
(y=0..15)
5
1
PU4
Port D pull-up bit y
(y=0..15)
4
1
PU3
Port D pull-up bit y
(y=0..15)
3
1
PU2
Port D pull-up bit y
(y=0..15)
2
1
PU1
Port D pull-up bit y
(y=0..15)
1
1
PU0
Port D pull-up bit y
(y=0..15)
0
1
PDCRD
PDCRD
Power Port D pull-down control
register
0x3C
0x20
read-write
0x00000000
PD15
Port D pull-down bit y
(y=0..15)
15
1
PD14
Port D pull-down bit y
(y=0..15)
14
1
PD13
Port D pull-down bit y
(y=0..15)
13
1
PD12
Port D pull-down bit y
(y=0..15)
12
1
PD11
Port D pull-down bit y
(y=0..15)
11
1
PD10
Port D pull-down bit y
(y=0..15)
10
1
PD9
Port D pull-down bit y
(y=0..15)
9
1
PD8
Port D pull-down bit y
(y=0..15)
8
1
PD7
Port D pull-down bit y
(y=0..15)
7
1
PD6
Port D pull-down bit y
(y=0..15)
6
1
PD5
Port D pull-down bit y
(y=0..15)
5
1
PD4
Port D pull-down bit y
(y=0..15)
4
1
PD3
Port D pull-down bit y
(y=0..15)
3
1
PD2
Port D pull-down bit y
(y=0..15)
2
1
PD1
Port D pull-down bit y
(y=0..15)
1
1
PD0
Port D pull-down bit y
(y=0..15)
0
1
PUCRE
PUCRE
Power Port E pull-up control
register
0x40
0x20
read-write
0x00000000
PU15
Port E pull-up bit y
(y=0..15)
15
1
PU14
Port E pull-up bit y
(y=0..15)
14
1
PU13
Port E pull-up bit y
(y=0..15)
13
1
PU12
Port E pull-up bit y
(y=0..15)
12
1
PU11
Port E pull-up bit y
(y=0..15)
11
1
PU10
Port E pull-up bit y
(y=0..15)
10
1
PU9
Port E pull-up bit y
(y=0..15)
9
1
PU8
Port E pull-up bit y
(y=0..15)
8
1
PU7
Port E pull-up bit y
(y=0..15)
7
1
PU6
Port E pull-up bit y
(y=0..15)
6
1
PU5
Port E pull-up bit y
(y=0..15)
5
1
PU4
Port E pull-up bit y
(y=0..15)
4
1
PU3
Port E pull-up bit y
(y=0..15)
3
1
PU2
Port E pull-up bit y
(y=0..15)
2
1
PU1
Port E pull-up bit y
(y=0..15)
1
1
PU0
Port E pull-up bit y
(y=0..15)
0
1
PDCRE
PDCRE
Power Port E pull-down control
register
0x44
0x20
read-write
0x00000000
PD15
Port E pull-down bit y
(y=0..15)
15
1
PD14
Port E pull-down bit y
(y=0..15)
14
1
PD13
Port E pull-down bit y
(y=0..15)
13
1
PD12
Port E pull-down bit y
(y=0..15)
12
1
PD11
Port E pull-down bit y
(y=0..15)
11
1
PD10
Port E pull-down bit y
(y=0..15)
10
1
PD9
Port E pull-down bit y
(y=0..15)
9
1
PD8
Port E pull-down bit y
(y=0..15)
8
1
PD7
Port E pull-down bit y
(y=0..15)
7
1
PD6
Port E pull-down bit y
(y=0..15)
6
1
PD5
Port E pull-down bit y
(y=0..15)
5
1
PD4
Port E pull-down bit y
(y=0..15)
4
1
PD3
Port E pull-down bit y
(y=0..15)
3
1
PD2
Port E pull-down bit y
(y=0..15)
2
1
PD1
Port E pull-down bit y
(y=0..15)
1
1
PD0
Port E pull-down bit y
(y=0..15)
0
1
PUCRF
PUCRF
Power Port F pull-up control
register
0x48
0x20
read-write
0x00000000
PU15
Port F pull-up bit y
(y=0..15)
15
1
PU14
Port F pull-up bit y
(y=0..15)
14
1
PU13
Port F pull-up bit y
(y=0..15)
13
1
PU12
Port F pull-up bit y
(y=0..15)
12
1
PU11
Port F pull-up bit y
(y=0..15)
11
1
PU10
Port F pull-up bit y
(y=0..15)
10
1
PU9
Port F pull-up bit y
(y=0..15)
9
1
PU8
Port F pull-up bit y
(y=0..15)
8
1
PU7
Port F pull-up bit y
(y=0..15)
7
1
PU6
Port F pull-up bit y
(y=0..15)
6
1
PU5
Port F pull-up bit y
(y=0..15)
5
1
PU4
Port F pull-up bit y
(y=0..15)
4
1
PU3
Port F pull-up bit y
(y=0..15)
3
1
PU2
Port F pull-up bit y
(y=0..15)
2
1
PU1
Port F pull-up bit y
(y=0..15)
1
1
PU0
Port F pull-up bit y
(y=0..15)
0
1
PDCRF
PDCRF
Power Port F pull-down control
register
0x4C
0x20
read-write
0x00000000
PD15
Port F pull-down bit y
(y=0..15)
15
1
PD14
Port F pull-down bit y
(y=0..15)
14
1
PD13
Port F pull-down bit y
(y=0..15)
13
1
PD12
Port F pull-down bit y
(y=0..15)
12
1
PD11
Port F pull-down bit y
(y=0..15)
11
1
PD10
Port F pull-down bit y
(y=0..15)
10
1
PD9
Port F pull-down bit y
(y=0..15)
9
1
PD8
Port F pull-down bit y
(y=0..15)
8
1
PD7
Port F pull-down bit y
(y=0..15)
7
1
PD6
Port F pull-down bit y
(y=0..15)
6
1
PD5
Port F pull-down bit y
(y=0..15)
5
1
PD4
Port F pull-down bit y
(y=0..15)
4
1
PD3
Port F pull-down bit y
(y=0..15)
3
1
PD2
Port F pull-down bit y
(y=0..15)
2
1
PD1
Port F pull-down bit y
(y=0..15)
1
1
PD0
Port F pull-down bit y
(y=0..15)
0
1
PUCRG
PUCRG
Power Port G pull-up control
register
0x50
0x20
read-write
0x00000000
PU15
Port G pull-up bit y
(y=0..15)
15
1
PU14
Port G pull-up bit y
(y=0..15)
14
1
PU13
Port G pull-up bit y
(y=0..15)
13
1
PU12
Port G pull-up bit y
(y=0..15)
12
1
PU11
Port G pull-up bit y
(y=0..15)
11
1
PU10
Port G pull-up bit y
(y=0..15)
10
1
PU9
Port G pull-up bit y
(y=0..15)
9
1
PU8
Port G pull-up bit y
(y=0..15)
8
1
PU7
Port G pull-up bit y
(y=0..15)
7
1
PU6
Port G pull-up bit y
(y=0..15)
6
1
PU5
Port G pull-up bit y
(y=0..15)
5
1
PU4
Port G pull-up bit y
(y=0..15)
4
1
PU3
Port G pull-up bit y
(y=0..15)
3
1
PU2
Port G pull-up bit y
(y=0..15)
2
1
PU1
Port G pull-up bit y
(y=0..15)
1
1
PU0
Port G pull-up bit y
(y=0..15)
0
1
PDCRG
PDCRG
Power Port G pull-down control
register
0x54
0x20
read-write
0x00000000
PD15
Port G pull-down bit y
(y=0..15)
15
1
PD14
Port G pull-down bit y
(y=0..15)
14
1
PD13
Port G pull-down bit y
(y=0..15)
13
1
PD12
Port G pull-down bit y
(y=0..15)
12
1
PD11
Port G pull-down bit y
(y=0..15)
11
1
PD10
Port G pull-down bit y
(y=0..15)
10
1
PD9
Port G pull-down bit y
(y=0..15)
9
1
PD8
Port G pull-down bit y
(y=0..15)
8
1
PD7
Port G pull-down bit y
(y=0..15)
7
1
PD6
Port G pull-down bit y
(y=0..15)
6
1
PD5
Port G pull-down bit y
(y=0..15)
5
1
PD4
Port G pull-down bit y
(y=0..15)
4
1
PD3
Port G pull-down bit y
(y=0..15)
3
1
PD2
Port G pull-down bit y
(y=0..15)
2
1
PD1
Port G pull-down bit y
(y=0..15)
1
1
PD0
Port G pull-down bit y
(y=0..15)
0
1
PUCRH
PUCRH
Power Port H pull-up control
register
0x58
0x20
read-write
0x00000000
PU1
Port H pull-up bit y
(y=0..1)
1
1
PU0
Port H pull-up bit y
(y=0..1)
0
1
PDCRH
PDCRH
Power Port H pull-down control
register
0x5C
0x20
read-write
0x00000000
PD1
Port H pull-down bit y
(y=0..1)
1
1
PD0
Port H pull-down bit y
(y=0..1)
0
1
SYSCFG
System configuration controller
SYSCFG
0x40010000
0x0
0x30
registers
MEMRMP
MEMRMP
memory remap register
0x0
0x20
read-write
0x00000000
FB_MODE
Flash Bank mode selection
8
1
QFS
QUADSPI memory mapping
swap
3
1
MEM_MODE
Memory mapping selection
0
3
CFGR1
CFGR1
configuration register 1
0x4
0x20
read-write
0x7C000001
FPU_IE
Floating Point Unit interrupts enable
bits
26
6
I2C3_FMP
I2C3 Fast-mode Plus driving capability
activation
22
1
I2C2_FMP
I2C2 Fast-mode Plus driving capability
activation
21
1
I2C1_FMP
I2C1 Fast-mode Plus driving capability
activation
20
1
I2C_PB9_FMP
Fast-mode Plus (Fm+) driving capability
activation on PB9
19
1
I2C_PB8_FMP
Fast-mode Plus (Fm+) driving capability
activation on PB8
18
1
I2C_PB7_FMP
Fast-mode Plus (Fm+) driving capability
activation on PB7
17
1
I2C_PB6_FMP
Fast-mode Plus (Fm+) driving capability
activation on PB6
16
1
BOOSTEN
I/O analog switch voltage booster
enable
8
1
FWDIS
Firewall disable
0
1
EXTICR1
EXTICR1
external interrupt configuration register
1
0x8
0x20
read-write
0x00000000
EXTI3
EXTI 3 configuration bits
12
3
EXTI2
EXTI 2 configuration bits
8
3
EXTI1
EXTI 1 configuration bits
4
3
EXTI0
EXTI 0 configuration bits
0
3
EXTICR2
EXTICR2
external interrupt configuration register
2
0xC
0x20
read-write
0x00000000
EXTI7
EXTI 7 configuration bits
12
3
EXTI6
EXTI 6 configuration bits
8
3
EXTI5
EXTI 5 configuration bits
4
3
EXTI4
EXTI 4 configuration bits
0
3
EXTICR3
EXTICR3
external interrupt configuration register
3
0x10
0x20
read-write
0x00000000
EXTI11
EXTI 11 configuration bits
12
3
EXTI10
EXTI 10 configuration bits
8
3
EXTI9
EXTI 9 configuration bits
4
3
EXTI8
EXTI 8 configuration bits
0
3
EXTICR4
EXTICR4
external interrupt configuration register
4
0x14
0x20
read-write
0x00000000
EXTI15
EXTI15 configuration bits
12
3
EXTI14
EXTI14 configuration bits
8
3
EXTI13
EXTI13 configuration bits
4
3
EXTI12
EXTI12 configuration bits
0
3
SCSR
SCSR
SCSR
0x18
0x20
0x00000000
SRAM2BSY
SRAM2 busy by erase
operation
1
1
read-only
SRAM2ER
SRAM2 Erase
0
1
read-write
CFGR2
CFGR2
CFGR2
0x1C
0x20
0x00000000
SPF
SRAM2 parity error flag
8
1
read-write
ECCL
ECC Lock
3
1
write-only
PVDL
PVD lock enable bit
2
1
write-only
SPL
SRAM2 parity lock bit
1
1
write-only
CLL
Cortex-M4 LOCKUP (Hardfault) output
enable bit
0
1
write-only
SWPR
SWPR
SWPR
0x20
0x20
write-only
0x00000000
P31WP
SRAM2 page 31 write
protection
31
1
P30WP
P30WP
30
1
P29WP
P29WP
29
1
P28WP
P28WP
28
1
P27WP
P27WP
27
1
P26WP
P26WP
26
1
P25WP
P25WP
25
1
P24WP
P24WP
24
1
P23WP
P23WP
23
1
P22WP
P22WP
22
1
P21WP
P21WP
21
1
P20WP
P20WP
20
1
P19WP
P19WP
19
1
P18WP
P18WP
18
1
P17WP
P17WP
17
1
P16WP
P16WP
16
1
P15WP
P15WP
15
1
P14WP
P14WP
14
1
P13WP
P13WP
13
1
P12WP
P12WP
12
1
P11WP
P11WP
11
1
P10WP
P10WP
10
1
P9WP
P9WP
9
1
P8WP
P8WP
8
1
P7WP
P7WP
7
1
P6WP
P6WP
6
1
P5WP
P5WP
5
1
P4WP
P4WP
4
1
P3WP
P3WP
3
1
P2WP
P2WP
2
1
P1WP
P1WP
1
1
P0WP
P0WP
0
1
SKR
SKR
SKR
0x24
0x20
write-only
0x00000000
KEY
SRAM2 write protection key for software
erase
0
8
DFSDM1
Digital filter for sigma delta
modulators
DFSDM
0x40016000
0x0
0x500
registers
DFSDM1_FLT3
DFSDM1_FLT3 global interrupt
42
DFSDM1_FLT0
DFSDM1_FLT0 global interrupt
61
DFSDM1_FLT1
DFSDM1_FLT1 global interrupt
62
DFSDM1_FLT2
DFSDM1_FLT2 global interrupt
63
CHCFG0R1
CHCFG0R1
channel configuration y
register
0x0
0x20
read-write
0x0
DFSDMEN
DFSDMEN
31
1
CKOUTSRC
CKOUTSRC
30
1
CKOUTDIV
CKOUTDIV
16
8
DATPACK
DATPACK
14
2
DATMPX
DATMPX
12
2
CHINSEL
CHINSEL
8
1
CHEN
CHEN
7
1
CKABEN
CKABEN
6
1
SCDEN
SCDEN
5
1
SPICKSEL
SPICKSEL
2
2
SITP
SITP
0
2
CHCFG0R2
CHCFG0R2
channel configuration y
register
0x4
0x20
read-write
0x0
OFFSET
OFFSET
8
24
DTRBS
DTRBS
3
5
AWSCD0R
AWSCD0R
analog watchdog and short-circuit detector
register
0x8
0x20
read-write
0x0
AWFORD
AWFORD
22
2
AWFOSR
AWFOSR
16
5
BKSCD
BKSCD
12
4
SCDT
SCDT
0
8
CHWDAT0R
CHWDAT0R
channel watchdog filter data
register
0xC
0x20
read-write
0x0
WDATA
WDATA
0
16
CHDATIN0R
CHDATIN0R
channel data input register
0x10
0x20
read-write
0x0
INDAT1
INDAT1
16
16
INDAT0
INDAT0
0
16
CHCFG1R1
CHCFG1R1
CHCFG1R1
0x20
0x20
read-write
0x0
DATPACK
DATPACK
14
2
DATMPX
DATMPX
12
2
CHINSEL
CHINSEL
8
1
CHEN
CHEN
7
1
CKABEN
CKABEN
6
1
SCDEN
SCDEN
5
1
SPICKSEL
SPICKSEL
2
2
SITP
SITP
0
2
CHCFG1R2
CHCFG1R2
CHCFG1R2
0x24
0x20
read-write
0x0
OFFSET
OFFSET
8
24
DTRBS
DTRBS
3
5
AWSCD1R
AWSCD1R
AWSCD1R
0x28
0x20
read-write
0x0
AWFORD
AWFORD
22
2
AWFOSR
AWFOSR
16
5
BKSCD
BKSCD
12
4
SCDT
SCDT
0
8
CHWDAT1R
CHWDAT1R
CHWDAT1R
0x2C
0x20
read-write
0x0
WDATA
WDATA
0
16
CHDATIN1R
CHDATIN1R
CHDATIN1R
0x30
0x20
read-write
0x0
INDAT1
INDAT1
16
16
INDAT0
INDAT0
0
16
CHCFG2R1
CHCFG2R1
CHCFG2R1
0x40
0x20
read-write
0x0
DATPACK
DATPACK
14
2
DATMPX
DATMPX
12
2
CHINSEL
CHINSEL
8
1
CHEN
CHEN
7
1
CKABEN
CKABEN
6
1
SCDEN
SCDEN
5
1
SPICKSEL
SPICKSEL
2
2
SITP
SITP
0
2
CHCFG2R2
CHCFG2R2
CHCFG2R2
0x44
0x20
read-write
0x0
OFFSET
OFFSET
8
24
DTRBS
DTRBS
3
5
AWSCD2R
AWSCD2R
AWSCD2R
0x48
0x20
read-write
0x0
AWFORD
AWFORD
22
2
AWFOSR
AWFOSR
16
5
BKSCD
BKSCD
12
4
SCDT
SCDT
0
8
CHWDAT2R
CHWDAT2R
CHWDAT2R
0x4C
0x20
read-write
0x0
WDATA
WDATA
0
16
CHDATIN2R
CHDATIN2R
CHDATIN2R
0x50
0x20
read-write
0x0
INDAT1
INDAT1
16
16
INDAT0
INDAT0
0
16
CHCFG3R1
CHCFG3R1
CHCFG3R1
0x60
0x20
read-write
0x0
DATPACK
DATPACK
14
2
DATMPX
DATMPX
12
2
CHINSEL
CHINSEL
8
1
CHEN
CHEN
7
1
CKABEN
CKABEN
6
1
SCDEN
SCDEN
5
1
SPICKSEL
SPICKSEL
2
2
SITP
SITP
0
2
CHCFG3R2
CHCFG3R2
CHCFG3R2
0x64
0x20
read-write
0x0
OFFSET
OFFSET
8
24
DTRBS
DTRBS
3
5
AWSCD3R
AWSCD3R
AWSCD3R
0x68
0x20
read-write
0x0
AWFORD
AWFORD
22
2
AWFOSR
AWFOSR
16
5
BKSCD
BKSCD
12
4
SCDT
SCDT
0
8
CHWDAT3R
CHWDAT3R
CHWDAT3R
0x6C
0x20
read-write
0x0
WDATA
WDATA
0
16
CHDATIN3R
CHDATIN3R
CHDATIN3R
0x70
0x20
read-write
0x0
INDAT1
INDAT1
16
16
INDAT0
INDAT0
0
16
CHCFG4R1
CHCFG4R1
CHCFG4R1
0x80
0x20
read-write
0x0
DATPACK
DATPACK
14
2
DATMPX
DATMPX
12
2
CHINSEL
CHINSEL
8
1
CHEN
CHEN
7
1
CKABEN
CKABEN
6
1
SCDEN
SCDEN
5
1
SPICKSEL
SPICKSEL
2
2
SITP
SITP
0
2
CHCFG4R2
CHCFG4R2
CHCFG4R2
0x84
0x20
read-write
0x0
OFFSET
OFFSET
8
24
DTRBS
DTRBS
3
5
AWSCD4R
AWSCD4R
AWSCD4R
0x88
0x20
read-write
0x0
AWFORD
AWFORD
22
2
AWFOSR
AWFOSR
16
5
BKSCD
BKSCD
12
4
SCDT
SCDT
0
8
CHWDAT4R
CHWDAT4R
CHWDAT4R
0x8C
0x20
read-write
0x0
WDATA
WDATA
0
16
CHDATIN4R
CHDATIN4R
CHDATIN4R
0x90
0x20
read-write
0x0
INDAT1
INDAT1
16
16
INDAT0
INDAT0
0
16
CHCFG5R1
CHCFG5R1
CHCFG5R1
0xA0
0x20
read-write
0x0
DATPACK
DATPACK
14
2
DATMPX
DATMPX
12
2
CHINSEL
CHINSEL
8
1
CHEN
CHEN
7
1
CKABEN
CKABEN
6
1
SCDEN
SCDEN
5
1
SPICKSEL
SPICKSEL
2
2
SITP
SITP
0
2
CHCFG5R2
CHCFG5R2
CHCFG5R2
0xA4
0x20
read-write
0x0
OFFSET
OFFSET
8
24
DTRBS
DTRBS
3
5
AWSCD5R
AWSCD5R
AWSCD5R
0xA8
0x20
read-write
0x0
AWFORD
AWFORD
22
2
AWFOSR
AWFOSR
16
5
BKSCD
BKSCD
12
4
SCDT
SCDT
0
8
CHWDAT5R
CHWDAT5R
CHWDAT5R
0xAC
0x20
read-write
0x0
WDATA
WDATA
0
16
CHDATIN5R
CHDATIN5R
CHDATIN5R
0xB0
0x20
read-write
0x0
INDAT1
INDAT1
16
16
INDAT0
INDAT0
0
16
CHCFG6R1
CHCFG6R1
CHCFG6R1
0xC0
0x20
read-write
0x0
DATPACK
DATPACK
14
2
DATMPX
DATMPX
12
2
CHINSEL
CHINSEL
8
1
CHEN
CHEN
7
1
CKABEN
CKABEN
6
1
SCDEN
SCDEN
5
1
SPICKSEL
SPICKSEL
2
2
SITP
SITP
0
2
CHCFG6R2
CHCFG6R2
CHCFG6R2
0xC4
0x20
read-write
0x0
OFFSET
OFFSET
8
24
DTRBS
DTRBS
3
5
AWSCD6R
AWSCD6R
AWSCD6R
0xC8
0x20
read-write
0x0
AWFORD
AWFORD
22
2
AWFOSR
AWFOSR
16
5
BKSCD
BKSCD
12
4
SCDT
SCDT
0
8
CHWDAT6R
CHWDAT6R
CHWDAT6R
0xCC
0x20
read-write
0x0
WDATA
WDATA
0
16
CHDATIN6R
CHDATIN6R
CHDATIN6R
0xD0
0x20
read-write
0x0
INDAT1
INDAT1
16
16
INDAT0
INDAT0
0
16
CHCFG7R1
CHCFG7R1
CHCFG7R1
0xE0
0x20
read-write
0x0
DATPACK
DATPACK
14
2
DATMPX
DATMPX
12
2
CHINSEL
CHINSEL
8
1
CHEN
CHEN
7
1
CKABEN
CKABEN
6
1
SCDEN
SCDEN
5
1
SPICKSEL
SPICKSEL
2
2
SITP
SITP
0
2
CHCFG7R2
CHCFG7R2
CHCFG7R2
0xE4
0x20
read-write
0x0
OFFSET
OFFSET
8
24
DTRBS
DTRBS
3
5
AWSCD7R
AWSCD7R
AWSCD7R
0xE8
0x20
read-write
0x0
AWFORD
AWFORD
22
2
AWFOSR
AWFOSR
16
5
BKSCD
BKSCD
12
4
SCDT
SCDT
0
8
CHWDAT7R
CHWDAT7R
CHWDAT7R
0xEC
0x20
read-write
0x0
WDATA
WDATA
0
16
CHDATIN7R
CHDATIN7R
CHDATIN7R
0xF0
0x20
read-write
0x0
INDAT1
INDAT1
16
16
INDAT0
INDAT0
0
16
DFSDM0_CR1
DFSDM0_CR1
control register 1
0x100
0x20
read-write
0x00000000
AWFSEL
Analog watchdog fast mode
select
30
1
FAST
Fast conversion mode selection for
regular conversions
29
1
RCH
Regular channel selection
24
3
RDMAEN
DMA channel enabled to read data for the
regular conversion
21
1
RSYNC
Launch regular conversion synchronously
with DFSDM0
19
1
RCONT
Continuous mode selection for regular
conversions
18
1
RSWSTART
Software start of a conversion on the
regular channel
17
1
JEXTEN
Trigger enable and trigger edge
selection for injected conversions
13
2
JEXTSEL
Trigger signal selection for launching
injected conversions
8
3
JDMAEN
DMA channel enabled to read data for the
injected channel group
5
1
JSCAN
Scanning conversion mode for injected
conversions
4
1
JSYNC
Launch an injected conversion
synchronously with the DFSDM0 JSWSTART
trigger
3
1
JSWSTART
Start a conversion of the injected group
of channels
1
1
DFEN
DFSDM enable
0
1
DFSDM0_CR2
DFSDM0_CR2
control register 2
0x104
0x20
read-write
0x00000000
AWDCH
Analog watchdog channel
selection
16
8
EXCH
Extremes detector channel
selection
8
8
CKABIE
Clock absence interrupt
enable
6
1
SCDIE
Short-circuit detector interrupt
enable
5
1
AWDIE
Analog watchdog interrupt
enable
4
1
ROVRIE
Regular data overrun interrupt
enable
3
1
JOVRIE
Injected data overrun interrupt
enable
2
1
REOCIE
Regular end of conversion interrupt
enable
1
1
JEOCIE
Injected end of conversion interrupt
enable
0
1
DFSDM0_ISR
DFSDM0_ISR
interrupt and status register
0x108
0x20
read-only
0x00FF0000
SCDF
short-circuit detector
flag
24
8
CKABF
Clock absence flag
16
8
RCIP
Regular conversion in progress
status
14
1
JCIP
Injected conversion in progress
status
13
1
AWDF
Analog watchdog
4
1
ROVRF
Regular conversion overrun
flag
3
1
JOVRF
Injected conversion overrun
flag
2
1
REOCF
End of regular conversion
flag
1
1
JEOCF
End of injected conversion
flag
0
1
DFSDM0_ICR
DFSDM0_ICR
interrupt flag clear register
0x10C
0x20
read-write
0x00000000
CLRSCDF
Clear the short-circuit detector
flag
24
8
CLRCKABF
Clear the clock absence
flag
16
8
CLRROVRF
Clear the regular conversion overrun
flag
3
1
CLRJOVRF
Clear the injected conversion overrun
flag
2
1
DFSDM0_JCHGR
DFSDM0_JCHGR
injected channel group selection
register
0x110
0x20
read-write
0x00000001
JCHG
Injected channel group
selection
0
8
DFSDM0_FCR
DFSDM0_FCR
filter control register
0x114
0x20
read-write
0x00000000
FORD
Sinc filter order
29
3
FOSR
Sinc filter oversampling ratio
(decimation rate)
16
10
IOSR
Integrator oversampling ratio (averaging
length)
0
8
DFSDM0_JDATAR
DFSDM0_JDATAR
data register for injected
group
0x118
0x20
read-only
0x00000000
JDATA
Injected group conversion
data
8
24
JDATACH
Injected channel most recently
converted
0
3
DFSDM0_RDATAR
DFSDM0_RDATAR
data register for the regular
channel
0x11C
0x20
read-only
0x00000000
RDATA
Regular channel conversion
data
8
24
RPEND
Regular channel pending
data
4
1
RDATACH
Regular channel most recently
converted
0
3
DFSDM0_AWHTR
DFSDM0_AWHTR
analog watchdog high threshold
register
0x120
0x20
read-write
0x00000000
AWHT
Analog watchdog high
threshold
8
24
BKAWH
Break signal assignment to analog
watchdog high threshold event
0
4
DFSDM0_AWLTR
DFSDM0_AWLTR
analog watchdog low threshold
register
0x124
0x20
read-write
0x00000000
AWLT
Analog watchdog low
threshold
8
24
BKAWL
Break signal assignment to analog
watchdog low threshold event
0
4
DFSDM0_AWSR
DFSDM0_AWSR
analog watchdog status
register
0x128
0x20
read-only
0x00000000
AWHTF
Analog watchdog high threshold
flag
8
8
AWLTF
Analog watchdog low threshold
flag
0
8
DFSDM0_AWCFR
DFSDM0_AWCFR
analog watchdog clear flag
register
0x12C
0x20
read-write
0x00000000
CLRAWHTF
Clear the analog watchdog high threshold
flag
8
8
CLRAWLTF
Clear the analog watchdog low threshold
flag
0
8
DFSDM0_EXMAX
DFSDM0_EXMAX
Extremes detector maximum
register
0x130
0x20
read-only
0x80000000
EXMAX
Extremes detector maximum
value
8
24
EXMAXCH
Extremes detector maximum data
channel
0
3
DFSDM0_EXMIN
DFSDM0_EXMIN
Extremes detector minimum
register
0x134
0x20
read-only
0x7FFFFF00
EXMIN
EXMIN
8
24
EXMINCH
Extremes detector minimum data
channel
0
3
DFSDM0_CNVTIMR
DFSDM0_CNVTIMR
conversion timer register
0x138
0x20
read-only
0x00000000
CNVCNT
28-bit timer counting conversion time t
= CNVCNT[27:0] / fDFSDM_CKIN
4
28
DFSDM1_CR1
DFSDM1_CR1
control register 1
0x200
0x20
read-write
0x00000000
AWFSEL
Analog watchdog fast mode
select
30
1
FAST
Fast conversion mode selection for
regular conversions
29
1
RCH
Regular channel selection
24
3
RDMAEN
DMA channel enabled to read data for the
regular conversion
21
1
RSYNC
Launch regular conversion synchronously
with DFSDM0
19
1
RCONT
Continuous mode selection for regular
conversions
18
1
RSWSTART
Software start of a conversion on the
regular channel
17
1
JEXTEN
Trigger enable and trigger edge
selection for injected conversions
13
2
JEXTSEL
Trigger signal selection for launching
injected conversions
8
3
JDMAEN
DMA channel enabled to read data for the
injected channel group
5
1
JSCAN
Scanning conversion mode for injected
conversions
4
1
JSYNC
Launch an injected conversion
synchronously with the DFSDM0 JSWSTART
trigger
3
1
JSWSTART
Start a conversion of the injected group
of channels
1
1
DFEN
DFSDM enable
0
1
DFSDM1_CR2
DFSDM1_CR2
control register 2
0x204
0x20
read-write
0x00000000
AWDCH
Analog watchdog channel
selection
16
8
EXCH
Extremes detector channel
selection
8
8
CKABIE
Clock absence interrupt
enable
6
1
SCDIE
Short-circuit detector interrupt
enable
5
1
AWDIE
Analog watchdog interrupt
enable
4
1
ROVRIE
Regular data overrun interrupt
enable
3
1
JOVRIE
Injected data overrun interrupt
enable
2
1
REOCIE
Regular end of conversion interrupt
enable
1
1
JEOCIE
Injected end of conversion interrupt
enable
0
1
DFSDM1_ISR
DFSDM1_ISR
interrupt and status register
0x208
0x20
read-only
0x00FF0000
SCDF
short-circuit detector
flag
24
8
CKABF
Clock absence flag
16
8
RCIP
Regular conversion in progress
status
14
1
JCIP
Injected conversion in progress
status
13
1
AWDF
Analog watchdog
4
1
ROVRF
Regular conversion overrun
flag
3
1
JOVRF
Injected conversion overrun
flag
2
1
REOCF
End of regular conversion
flag
1
1
JEOCF
End of injected conversion
flag
0
1
DFSDM1_ICR
DFSDM1_ICR
interrupt flag clear register
0x20C
0x20
read-write
0x00000000
CLRSCDF
Clear the short-circuit detector
flag
24
8
CLRCKABF
Clear the clock absence
flag
16
8
CLRROVRF
Clear the regular conversion overrun
flag
3
1
CLRJOVRF
Clear the injected conversion overrun
flag
2
1
DFSDM1_JCHGR
DFSDM1_JCHGR
injected channel group selection
register
0x210
0x20
read-write
0x00000001
JCHG
Injected channel group
selection
0
8
DFSDM1_FCR
DFSDM1_FCR
filter control register
0x214
0x20
read-write
0x00000000
FORD
Sinc filter order
29
3
FOSR
Sinc filter oversampling ratio
(decimation rate)
16
10
IOSR
Integrator oversampling ratio (averaging
length)
0
8
DFSDM1_JDATAR
DFSDM1_JDATAR
data register for injected
group
0x218
0x20
read-only
0x00000000
JDATA
Injected group conversion
data
8
24
JDATACH
Injected channel most recently
converted
0
3
DFSDM1_RDATAR
DFSDM1_RDATAR
data register for the regular
channel
0x21C
0x20
read-only
0x00000000
RDATA
Regular channel conversion
data
8
24
RPEND
Regular channel pending
data
4
1
RDATACH
Regular channel most recently
converted
0
3
DFSDM1_AWHTR
DFSDM1_AWHTR
analog watchdog high threshold
register
0x220
0x20
read-write
0x00000000
AWHT
Analog watchdog high
threshold
8
24
BKAWH
Break signal assignment to analog
watchdog high threshold event
0
4
DFSDM1_AWLTR
DFSDM1_AWLTR
analog watchdog low threshold
register
0x224
0x20
read-write
0x00000000
AWLT
Analog watchdog low
threshold
8
24
BKAWL
Break signal assignment to analog
watchdog low threshold event
0
4
DFSDM1_AWSR
DFSDM1_AWSR
analog watchdog status
register
0x228
0x20
read-only
0x00000000
AWHTF
Analog watchdog high threshold
flag
8
8
AWLTF
Analog watchdog low threshold
flag
0
8
DFSDM1_AWCFR
DFSDM1_AWCFR
analog watchdog clear flag
register
0x22C
0x20
read-write
0x00000000
CLRAWHTF
Clear the analog watchdog high threshold
flag
8
8
CLRAWLTF
Clear the analog watchdog low threshold
flag
0
8
DFSDM1_EXMAX
DFSDM1_EXMAX
Extremes detector maximum
register
0x230
0x20
read-only
0x80000000
EXMAX
Extremes detector maximum
value
8
24
EXMAXCH
Extremes detector maximum data
channel
0
3
DFSDM1_EXMIN
DFSDM1_EXMIN
Extremes detector minimum
register
0x234
0x20
read-only
0x7FFFFF00
EXMIN
EXMIN
8
24
EXMINCH
Extremes detector minimum data
channel
0
3
DFSDM1_CNVTIMR
DFSDM1_CNVTIMR
conversion timer register
0x238
0x20
read-only
0x00000000
CNVCNT
28-bit timer counting conversion time t
= CNVCNT[27:0] / fDFSDM_CKIN
4
28
DFSDM2_CR1
DFSDM2_CR1
control register 1
0x300
0x20
read-write
0x00000000
AWFSEL
Analog watchdog fast mode
select
30
1
FAST
Fast conversion mode selection for
regular conversions
29
1
RCH
Regular channel selection
24
3
RDMAEN
DMA channel enabled to read data for the
regular conversion
21
1
RSYNC
Launch regular conversion synchronously
with DFSDM0
19
1
RCONT
Continuous mode selection for regular
conversions
18
1
RSWSTART
Software start of a conversion on the
regular channel
17
1
JEXTEN
Trigger enable and trigger edge
selection for injected conversions
13
2
JEXTSEL
Trigger signal selection for launching
injected conversions
8
3
JDMAEN
DMA channel enabled to read data for the
injected channel group
5
1
JSCAN
Scanning conversion mode for injected
conversions
4
1
JSYNC
Launch an injected conversion
synchronously with the DFSDM0 JSWSTART
trigger
3
1
JSWSTART
Start a conversion of the injected group
of channels
1
1
DFEN
DFSDM enable
0
1
DFSDM2_CR2
DFSDM2_CR2
control register 2
0x304
0x20
read-write
0x00000000
AWDCH
Analog watchdog channel
selection
16
8
EXCH
Extremes detector channel
selection
8
8
CKABIE
Clock absence interrupt
enable
6
1
SCDIE
Short-circuit detector interrupt
enable
5
1
AWDIE
Analog watchdog interrupt
enable
4
1
ROVRIE
Regular data overrun interrupt
enable
3
1
JOVRIE
Injected data overrun interrupt
enable
2
1
REOCIE
Regular end of conversion interrupt
enable
1
1
JEOCIE
Injected end of conversion interrupt
enable
0
1
DFSDM2_ISR
DFSDM2_ISR
interrupt and status register
0x308
0x20
read-only
0x00FF0000
SCDF
short-circuit detector
flag
24
8
CKABF
Clock absence flag
16
8
RCIP
Regular conversion in progress
status
14
1
JCIP
Injected conversion in progress
status
13
1
AWDF
Analog watchdog
4
1
ROVRF
Regular conversion overrun
flag
3
1
JOVRF
Injected conversion overrun
flag
2
1
REOCF
End of regular conversion
flag
1
1
JEOCF
End of injected conversion
flag
0
1
DFSDM2_ICR
DFSDM2_ICR
interrupt flag clear register
0x30C
0x20
read-write
0x00000000
CLRSCDF
Clear the short-circuit detector
flag
24
8
CLRCKABF
Clear the clock absence
flag
16
8
CLRROVRF
Clear the regular conversion overrun
flag
3
1
CLRJOVRF
Clear the injected conversion overrun
flag
2
1
DFSDM2_JCHGR
DFSDM2_JCHGR
injected channel group selection
register
0x310
0x20
read-write
0x00000001
JCHG
Injected channel group
selection
0
8
DFSDM2_FCR
DFSDM2_FCR
filter control register
0x314
0x20
read-write
0x00000000
FORD
Sinc filter order
29
3
FOSR
Sinc filter oversampling ratio
(decimation rate)
16
10
IOSR
Integrator oversampling ratio (averaging
length)
0
8
DFSDM2_JDATAR
DFSDM2_JDATAR
data register for injected
group
0x318
0x20
read-only
0x00000000
JDATA
Injected group conversion
data
8
24
JDATACH
Injected channel most recently
converted
0
3
DFSDM2_RDATAR
DFSDM2_RDATAR
data register for the regular
channel
0x31C
0x20
read-only
0x00000000
RDATA
Regular channel conversion
data
8
24
RPEND
Regular channel pending
data
4
1
RDATACH
Regular channel most recently
converted
0
3
DFSDM2_AWHTR
DFSDM2_AWHTR
analog watchdog high threshold
register
0x320
0x20
read-write
0x00000000
AWHT
Analog watchdog high
threshold
8
24
BKAWH
Break signal assignment to analog
watchdog high threshold event
0
4
DFSDM2_AWLTR
DFSDM2_AWLTR
analog watchdog low threshold
register
0x324
0x20
read-write
0x00000000
AWLT
Analog watchdog low
threshold
8
24
BKAWL
Break signal assignment to analog
watchdog low threshold event
0
4
DFSDM2_AWSR
DFSDM2_AWSR
analog watchdog status
register
0x328
0x20
read-only
0x00000000
AWHTF
Analog watchdog high threshold
flag
8
8
AWLTF
Analog watchdog low threshold
flag
0
8
DFSDM2_AWCFR
DFSDM2_AWCFR
analog watchdog clear flag
register
0x32C
0x20
read-write
0x00000000
CLRAWHTF
Clear the analog watchdog high threshold
flag
8
8
CLRAWLTF
Clear the analog watchdog low threshold
flag
0
8
DFSDM2_EXMAX
DFSDM2_EXMAX
Extremes detector maximum
register
0x330
0x20
read-only
0x80000000
EXMAX
Extremes detector maximum
value
8
24
EXMAXCH
Extremes detector maximum data
channel
0
3
DFSDM2_EXMIN
DFSDM2_EXMIN
Extremes detector minimum
register
0x334
0x20
read-only
0x7FFFFF00
EXMIN
EXMIN
8
24
EXMINCH
Extremes detector minimum data
channel
0
3
DFSDM2_CNVTIMR
DFSDM2_CNVTIMR
conversion timer register
0x338
0x20
read-only
0x00000000
CNVCNT
28-bit timer counting conversion time t
= CNVCNT[27:0] / fDFSDM_CKIN
4
28
DFSDM3_CR1
DFSDM3_CR1
control register 1
0x400
0x20
read-write
0x00000000
AWFSEL
Analog watchdog fast mode
select
30
1
FAST
Fast conversion mode selection for
regular conversions
29
1
RCH
Regular channel selection
24
3
RDMAEN
DMA channel enabled to read data for the
regular conversion
21
1
RSYNC
Launch regular conversion synchronously
with DFSDM0
19
1
RCONT
Continuous mode selection for regular
conversions
18
1
RSWSTART
Software start of a conversion on the
regular channel
17
1
JEXTEN
Trigger enable and trigger edge
selection for injected conversions
13
2
JEXTSEL
Trigger signal selection for launching
injected conversions
8
3
JDMAEN
DMA channel enabled to read data for the
injected channel group
5
1
JSCAN
Scanning conversion mode for injected
conversions
4
1
JSYNC
Launch an injected conversion
synchronously with the DFSDM0 JSWSTART
trigger
3
1
JSWSTART
Start a conversion of the injected group
of channels
1
1
DFEN
DFSDM enable
0
1
DFSDM3_CR2
DFSDM3_CR2
control register 2
0x404
0x20
read-write
0x00000000
AWDCH
Analog watchdog channel
selection
16
8
EXCH
Extremes detector channel
selection
8
8
CKABIE
Clock absence interrupt
enable
6
1
SCDIE
Short-circuit detector interrupt
enable
5
1
AWDIE
Analog watchdog interrupt
enable
4
1
ROVRIE
Regular data overrun interrupt
enable
3
1
JOVRIE
Injected data overrun interrupt
enable
2
1
REOCIE
Regular end of conversion interrupt
enable
1
1
JEOCIE
Injected end of conversion interrupt
enable
0
1
DFSDM3_ISR
DFSDM3_ISR
interrupt and status register
0x408
0x20
read-only
0x00FF0000
SCDF
short-circuit detector
flag
24
8
CKABF
Clock absence flag
16
8
RCIP
Regular conversion in progress
status
14
1
JCIP
Injected conversion in progress
status
13
1
AWDF
Analog watchdog
4
1
ROVRF
Regular conversion overrun
flag
3
1
JOVRF
Injected conversion overrun
flag
2
1
REOCF
End of regular conversion
flag
1
1
JEOCF
End of injected conversion
flag
0
1
DFSDM3_ICR
DFSDM3_ICR
interrupt flag clear register
0x40C
0x20
read-write
0x00000000
CLRSCDF
Clear the short-circuit detector
flag
24
8
CLRCKABF
Clear the clock absence
flag
16
8
CLRROVRF
Clear the regular conversion overrun
flag
3
1
CLRJOVRF
Clear the injected conversion overrun
flag
2
1
DFSDM3_JCHGR
DFSDM3_JCHGR
injected channel group selection
register
0x410
0x20
read-write
0x00000001
JCHG
Injected channel group
selection
0
8
DFSDM3_FCR
DFSDM3_FCR
filter control register
0x414
0x20
read-write
0x00000000
FORD
Sinc filter order
29
3
FOSR
Sinc filter oversampling ratio
(decimation rate)
16
10
IOSR
Integrator oversampling ratio (averaging
length)
0
8
DFSDM3_JDATAR
DFSDM3_JDATAR
data register for injected
group
0x418
0x20
read-only
0x00000000
JDATA
Injected group conversion
data
8
24
JDATACH
Injected channel most recently
converted
0
3
DFSDM3_RDATAR
DFSDM3_RDATAR
data register for the regular
channel
0x41C
0x20
read-only
0x00000000
RDATA
Regular channel conversion
data
8
24
RPEND
Regular channel pending
data
4
1
RDATACH
Regular channel most recently
converted
0
3
DFSDM3_AWHTR
DFSDM3_AWHTR
analog watchdog high threshold
register
0x420
0x20
read-write
0x00000000
AWHT
Analog watchdog high
threshold
8
24
BKAWH
Break signal assignment to analog
watchdog high threshold event
0
4
DFSDM3_AWLTR
DFSDM3_AWLTR
analog watchdog low threshold
register
0x424
0x20
read-write
0x00000000
AWLT
Analog watchdog low
threshold
8
24
BKAWL
Break signal assignment to analog
watchdog low threshold event
0
4
DFSDM3_AWSR
DFSDM3_AWSR
analog watchdog status
register
0x428
0x20
read-only
0x00000000
AWHTF
Analog watchdog high threshold
flag
8
8
AWLTF
Analog watchdog low threshold
flag
0
8
DFSDM3_AWCFR
DFSDM3_AWCFR
analog watchdog clear flag
register
0x42C
0x20
read-write
0x00000000
CLRAWHTF
Clear the analog watchdog high threshold
flag
8
8
CLRAWLTF
Clear the analog watchdog low threshold
flag
0
8
DFSDM3_EXMAX
DFSDM3_EXMAX
Extremes detector maximum
register
0x430
0x20
read-only
0x80000000
EXMAX
Extremes detector maximum
value
8
24
EXMAXCH
Extremes detector maximum data
channel
0
3
DFSDM3_EXMIN
DFSDM3_EXMIN
Extremes detector minimum
register
0x434
0x20
read-only
0x7FFFFF00
EXMIN
EXMIN
8
24
EXMINCH
Extremes detector minimum data
channel
0
3
DFSDM3_CNVTIMR
DFSDM3_CNVTIMR
conversion timer register
0x438
0x20
read-only
0x00000000
CNVCNT
28-bit timer counting conversion time t
= CNVCNT[27:0] / fDFSDM_CKIN
4
28
RNG
Random number generator
RNG
0x50060800
0x0
0x400
registers
RNG_HASH
RNG and HASH global interrupt
80
CR
CR
control register
0x0
0x20
read-write
0x00000000
IE
Interrupt enable
3
1
RNGEN
Random number generator
enable
2
1
SR
SR
status register
0x4
0x20
0x00000000
SEIS
Seed error interrupt
status
6
1
read-write
CEIS
Clock error interrupt
status
5
1
read-write
SECS
Seed error current status
2
1
read-only
CECS
Clock error current status
1
1
read-only
DRDY
Data ready
0
1
read-only
DR
DR
data register
0x8
0x20
read-only
0x00000000
RNDATA
Random data
0
32
AES
Advanced encryption standard hardware
accelerator
AES
0x50060000
0x0
0x400
registers
AES
AES global interrupt
79
CR
CR
control register
0x0
0x20
read-write
0x00000000
DMAOUTEN
Enable DMA management of data output
phase
12
1
DMAINEN
Enable DMA management of data input
phase
11
1
ERRIE
Error interrupt enable
10
1
CCFIE
CCF flag interrupt enable
9
1
ERRC
Error clear
8
1
CCFC
Computation Complete Flag
Clear
7
1
CHMOD
AES chaining mode
5
2
MODE
AES operating mode
3
2
DATATYPE
Data type selection (for data in and
data out to/from the cryptographic
block)
1
2
EN
AES enable
0
1
SR
SR
status register
0x4
0x20
read-only
0x00000000
WRERR
Write error flag
2
1
RDERR
Read error flag
1
1
CCF
Computation complete flag
0
1
DINR
DINR
data input register
0x8
0x20
read-write
0x00000000
AES_DINR
Data Input Register
0
32
DOUTR
DOUTR
data output register
0xC
0x20
read-only
0x00000000
AES_DOUTR
Data output register
0
32
KEYR0
KEYR0
key register 0
0x10
0x20
read-write
0x00000000
AES_KEYR0
Data Output Register (LSB key
[31:0])
0
32
KEYR1
KEYR1
key register 1
0x14
0x20
read-write
0x00000000
AES_KEYR1
AES key register (key
[63:32])
0
32
KEYR2
KEYR2
key register 2
0x18
0x20
read-write
0x00000000
AES_KEYR2
AES key register (key
[95:64])
0
32
KEYR3
KEYR3
key register 3
0x1C
0x20
read-write
0x00000000
AES_KEYR3
AES key register (MSB key
[127:96])
0
32
IVR0
IVR0
initialization vector register
0
0x20
0x20
read-write
0x00000000
AES_IVR0
initialization vector register (LSB IVR
[31:0])
0
32
IVR1
IVR1
initialization vector register
1
0x24
0x20
read-write
0x00000000
AES_IVR1
Initialization Vector Register (IVR
[63:32])
0
32
IVR2
IVR2
initialization vector register
2
0x28
0x20
read-write
0x00000000
AES_IVR2
Initialization Vector Register (IVR
[95:64])
0
32
IVR3
IVR3
initialization vector register
3
0x2C
0x20
read-write
0x00000000
AES_IVR3
Initialization Vector Register (MSB IVR
[127:96])
0
32
ADC1
Analog-to-Digital Converter
ADC
0x50040000
0x0
0xB9
registers
ADC1_2
ADC1 and ADC2 global interrupt
18
ADC3
ADC3 global interrupt
47
ISR
ISR
interrupt and status register
0x0
0x20
read-write
0x00000000
JQOVF
JQOVF
10
1
AWD3
AWD3
9
1
AWD2
AWD2
8
1
AWD1
AWD1
7
1
JEOS
JEOS
6
1
JEOC
JEOC
5
1
OVR
OVR
4
1
EOS
EOS
3
1
EOC
EOC
2
1
EOSMP
EOSMP
1
1
ADRDY
ADRDY
0
1
IER
IER
interrupt enable register
0x4
0x20
read-write
0x00000000
JQOVFIE
JQOVFIE
10
1
AWD3IE
AWD3IE
9
1
AWD2IE
AWD2IE
8
1
AWD1IE
AWD1IE
7
1
JEOSIE
JEOSIE
6
1
JEOCIE
JEOCIE
5
1
OVRIE
OVRIE
4
1
EOSIE
EOSIE
3
1
EOCIE
EOCIE
2
1
EOSMPIE
EOSMPIE
1
1
ADRDYIE
ADRDYIE
0
1
CR
CR
control register
0x8
0x20
read-write
0x00000000
ADCAL
ADCAL
31
1
ADCALDIF
ADCALDIF
30
1
DEEPPWD
DEEPPWD
29
1
ADVREGEN
ADVREGEN
28
1
JADSTP
JADSTP
5
1
ADSTP
ADSTP
4
1
JADSTART
JADSTART
3
1
ADSTART
ADSTART
2
1
ADDIS
ADDIS
1
1
ADEN
ADEN
0
1
CFGR
CFGR
configuration register
0xC
0x20
read-write
0x00000000
JQDIS
Injected Queue disable
31
1
AWDCH1CH
AWDCH1CH
26
5
JAUTO
JAUTO
25
1
JAWD1EN
JAWD1EN
24
1
AWD1EN
AWD1EN
23
1
AWD1SGL
AWD1SGL
22
1
JQM
JQM
21
1
JDISCEN
JDISCEN
20
1
DISCNUM
DISCNUM
17
3
DISCEN
DISCEN
16
1
AUTDLY
AUTDLY
14
1
CONT
CONT
13
1
OVRMOD
OVRMOD
12
1
EXTEN
EXTEN
10
2
EXTSEL
EXTSEL
6
4
ALIGN
ALIGN
5
1
RES
RES
3
2
DFSDMCFG
DFSDMCFG
2
1
DMACFG
DMACFG
1
1
DMAEN
DMAEN
0
1
CFGR2
CFGR2
configuration register
0x10
0x20
read-write
0x00000000
ROVSM
EXTEN
10
1
TROVS
Triggered Regular
Oversampling
9
1
OVSS
ALIGN
5
4
OVSR
RES
2
3
JOVSE
DMACFG
1
1
ROVSE
DMAEN
0
1
SMPR1
SMPR1
sample time register 1
0x14
0x20
read-write
0x00000000
SMP9
SMP9
27
3
SMP8
SMP8
24
3
SMP7
SMP7
21
3
SMP6
SMP6
18
3
SMP5
SMP5
15
3
SMP4
SMP4
12
3
SMP3
SMP3
9
3
SMP2
SMP2
6
3
SMP1
SMP1
3
3
SMPPLUS
Addition of one clock cycle to the
sampling time
31
1
SMP0
SMP0
0
3
SMPR2
SMPR2
sample time register 2
0x18
0x20
read-write
0x00000000
SMP18
SMP18
24
3
SMP17
SMP17
21
3
SMP16
SMP16
18
3
SMP15
SMP15
15
3
SMP14
SMP14
12
3
SMP13
SMP13
9
3
SMP12
SMP12
6
3
SMP11
SMP11
3
3
SMP10
SMP10
0
3
TR1
TR1
watchdog threshold register 1
0x20
0x20
read-write
0x0FFF0000
HT1
HT1
16
12
LT1
LT1
0
12
TR2
TR2
watchdog threshold register
0x24
0x20
read-write
0x0FFF0000
HT2
HT2
16
8
LT2
LT2
0
8
TR3
TR3
watchdog threshold register 3
0x28
0x20
read-write
0x0FFF0000
HT3
HT3
16
8
LT3
LT3
0
8
SQR1
SQR1
regular sequence register 1
0x30
0x20
read-write
0x00000000
SQ4
SQ4
24
5
SQ3
SQ3
18
5
SQ2
SQ2
12
5
SQ1
SQ1
6
5
L
Regular channel sequence
length
0
4
SQR2
SQR2
regular sequence register 2
0x34
0x20
read-write
0x00000000
SQ9
SQ9
24
5
SQ8
SQ8
18
5
SQ7
SQ7
12
5
SQ6
SQ6
6
5
SQ5
SQ5
0
5
SQR3
SQR3
regular sequence register 3
0x38
0x20
read-write
0x00000000
SQ14
SQ14
24
5
SQ13
SQ13
18
5
SQ12
SQ12
12
5
SQ11
SQ11
6
5
SQ10
SQ10
0
5
SQR4
SQR4
regular sequence register 4
0x3C
0x20
read-write
0x00000000
SQ16
SQ16
6
5
SQ15
SQ15
0
5
DR
DR
regular Data Register
0x40
0x20
read-only
0x00000000
RDATA
Regular Data converted
0
16
JSQR
JSQR
injected sequence register
0x4C
0x20
read-write
0x00000000
JSQ4
JSQ4
26
5
JSQ3
JSQ3
20
5
JSQ2
JSQ2
14
5
JSQ1
JSQ1
8
5
JEXTEN
JEXTEN
6
2
JEXTSEL
JEXTSEL
2
4
JL
JL
0
2
OFR1
OFR1
offset register 1
0x60
0x20
read-write
0x00000000
OFFSET1_EN
OFFSET1_EN
31
1
OFFSET1_CH
OFFSET1_CH
26
5
OFFSET1
OFFSET1
0
12
OFR2
OFR2
offset register 2
0x64
0x20
read-write
0x00000000
OFFSET2_EN
OFFSET2_EN
31
1
OFFSET2_CH
OFFSET2_CH
26
5
OFFSET2
OFFSET2
0
12
OFR3
OFR3
offset register 3
0x68
0x20
read-write
0x00000000
OFFSET3_EN
OFFSET3_EN
31
1
OFFSET3_CH
OFFSET3_CH
26
5
OFFSET3
OFFSET3
0
12
OFR4
OFR4
offset register 4
0x6C
0x20
read-write
0x00000000
OFFSET4_EN
OFFSET4_EN
31
1
OFFSET4_CH
OFFSET4_CH
26
5
OFFSET4
OFFSET4
0
12
JDR1
JDR1
injected data register 1
0x80
0x20
read-only
0x00000000
JDATA1
JDATA1
0
16
JDR2
JDR2
injected data register 2
0x84
0x20
read-only
0x00000000
JDATA2
JDATA2
0
16
JDR3
JDR3
injected data register 3
0x88
0x20
read-only
0x00000000
JDATA3
JDATA3
0
16
JDR4
JDR4
injected data register 4
0x8C
0x20
read-only
0x00000000
JDATA4
JDATA4
0
16
AWD2CR
AWD2CR
Analog Watchdog 2 Configuration
Register
0xA0
0x20
read-write
0x00000000
AWD2CH
AWD2CH
0
19
AWD3CR
AWD3CR
Analog Watchdog 3 Configuration
Register
0xA4
0x20
read-write
0x00000000
AWD3CH
AWD3CH
0
19
DIFSEL
DIFSEL
Differential Mode Selection Register
2
0xB0
0x20
0x00000000
DIFSEL_0
Differential mode for channels
0
0
1
read-only
DIFSEL_1_15
Differential mode for channels 15 to
1
1
15
read-write
DIFSEL_16_18
Differential mode for channels 18 to
16
16
3
read-only
CALFACT
CALFACT
Calibration Factors
0xB4
0x20
read-write
0x00000000
CALFACT_D
CALFACT_D
16
7
CALFACT_S
CALFACT_S
0
7
ADC2
0x50040100
ADC1_2
ADC1 and ADC2 global interrupt
18
ADC3
ADC3 global interrupt
47
ADC3
0x50040200
ADC1_2
ADC1 and ADC2 global interrupt
18
ADC3
ADC3 global interrupt
47
ADC_Common
Analog-to-Digital Converter
ADC
0x50040300
0x0
0x11
registers
CSR
CSR
ADC Common status register
0x0
0x20
read-only
0x00000000
ADDRDY_MST
ADDRDY_MST
0
1
EOSMP_MST
EOSMP_MST
1
1
EOC_MST
EOC_MST
2
1
EOS_MST
EOS_MST
3
1
OVR_MST
OVR_MST
4
1
JEOC_MST
JEOC_MST
5
1
JEOS_MST
JEOS_MST
6
1
AWD1_MST
AWD1_MST
7
1
AWD2_MST
AWD2_MST
8
1
AWD3_MST
AWD3_MST
9
1
JQOVF_MST
JQOVF_MST
10
1
ADRDY_SLV
ADRDY_SLV
16
1
EOSMP_SLV
EOSMP_SLV
17
1
EOC_SLV
End of regular conversion of the slave
ADC
18
1
EOS_SLV
End of regular sequence flag of the
slave ADC
19
1
OVR_SLV
Overrun flag of the slave
ADC
20
1
JEOC_SLV
End of injected conversion flag of the
slave ADC
21
1
JEOS_SLV
End of injected sequence flag of the
slave ADC
22
1
AWD1_SLV
Analog watchdog 1 flag of the slave
ADC
23
1
AWD2_SLV
Analog watchdog 2 flag of the slave
ADC
24
1
AWD3_SLV
Analog watchdog 3 flag of the slave
ADC
25
1
JQOVF_SLV
Injected Context Queue Overflow flag of
the slave ADC
26
1
CCR
CCR
ADC common control register
0x8
0x20
read-write
0x00000000
DUAL
Dual ADC mode selection
0
5
DELAY
Delay between 2 sampling
phases
8
4
DMACFG
DMA configuration (for multi-ADC
mode)
13
1
MDMA
Direct memory access mode for multi ADC
mode
14
2
CKMODE
ADC clock mode
16
2
VREFEN
VREFINT enable
22
1
CH17SEL
CH17 selection
23
1
CH18SEL
CH18 selection
24
1
PRESC
ADC prescaler
18
4
CDR
CDR
ADC common regular data register for dual
and triple modes
0xC
0x20
read-only
0x00000000
RDATA_SLV
Regular data of the slave
ADC
16
16
RDATA_MST
Regular data of the master
ADC
0
16
GPIOA
General-purpose I/Os
GPIO
0x48000000
0x0
0x400
registers
MODER
MODER
GPIO port mode register
0x0
0x20
read-write
0xA8000000
MODER15
Port x configuration bits (y =
0..15)
30
2
MODER14
Port x configuration bits (y =
0..15)
28
2
MODER13
Port x configuration bits (y =
0..15)
26
2
MODER12
Port x configuration bits (y =
0..15)
24
2
MODER11
Port x configuration bits (y =
0..15)
22
2
MODER10
Port x configuration bits (y =
0..15)
20
2
MODER9
Port x configuration bits (y =
0..15)
18
2
MODER8
Port x configuration bits (y =
0..15)
16
2
MODER7
Port x configuration bits (y =
0..15)
14
2
MODER6
Port x configuration bits (y =
0..15)
12
2
MODER5
Port x configuration bits (y =
0..15)
10
2
MODER4
Port x configuration bits (y =
0..15)
8
2
MODER3
Port x configuration bits (y =
0..15)
6
2
MODER2
Port x configuration bits (y =
0..15)
4
2
MODER1
Port x configuration bits (y =
0..15)
2
2
MODER0
Port x configuration bits (y =
0..15)
0
2
OTYPER
OTYPER
GPIO port output type register
0x4
0x20
read-write
0x00000000
OT15
Port x configuration bits (y =
0..15)
15
1
OT14
Port x configuration bits (y =
0..15)
14
1
OT13
Port x configuration bits (y =
0..15)
13
1
OT12
Port x configuration bits (y =
0..15)
12
1
OT11
Port x configuration bits (y =
0..15)
11
1
OT10
Port x configuration bits (y =
0..15)
10
1
OT9
Port x configuration bits (y =
0..15)
9
1
OT8
Port x configuration bits (y =
0..15)
8
1
OT7
Port x configuration bits (y =
0..15)
7
1
OT6
Port x configuration bits (y =
0..15)
6
1
OT5
Port x configuration bits (y =
0..15)
5
1
OT4
Port x configuration bits (y =
0..15)
4
1
OT3
Port x configuration bits (y =
0..15)
3
1
OT2
Port x configuration bits (y =
0..15)
2
1
OT1
Port x configuration bits (y =
0..15)
1
1
OT0
Port x configuration bits (y =
0..15)
0
1
OSPEEDR
OSPEEDR
GPIO port output speed
register
0x8
0x20
read-write
0x00000000
OSPEEDR15
Port x configuration bits (y =
0..15)
30
2
OSPEEDR14
Port x configuration bits (y =
0..15)
28
2
OSPEEDR13
Port x configuration bits (y =
0..15)
26
2
OSPEEDR12
Port x configuration bits (y =
0..15)
24
2
OSPEEDR11
Port x configuration bits (y =
0..15)
22
2
OSPEEDR10
Port x configuration bits (y =
0..15)
20
2
OSPEEDR9
Port x configuration bits (y =
0..15)
18
2
OSPEEDR8
Port x configuration bits (y =
0..15)
16
2
OSPEEDR7
Port x configuration bits (y =
0..15)
14
2
OSPEEDR6
Port x configuration bits (y =
0..15)
12
2
OSPEEDR5
Port x configuration bits (y =
0..15)
10
2
OSPEEDR4
Port x configuration bits (y =
0..15)
8
2
OSPEEDR3
Port x configuration bits (y =
0..15)
6
2
OSPEEDR2
Port x configuration bits (y =
0..15)
4
2
OSPEEDR1
Port x configuration bits (y =
0..15)
2
2
OSPEEDR0
Port x configuration bits (y =
0..15)
0
2
PUPDR
PUPDR
GPIO port pull-up/pull-down
register
0xC
0x20
read-write
0x64000000
PUPDR15
Port x configuration bits (y =
0..15)
30
2
PUPDR14
Port x configuration bits (y =
0..15)
28
2
PUPDR13
Port x configuration bits (y =
0..15)
26
2
PUPDR12
Port x configuration bits (y =
0..15)
24
2
PUPDR11
Port x configuration bits (y =
0..15)
22
2
PUPDR10
Port x configuration bits (y =
0..15)
20
2
PUPDR9
Port x configuration bits (y =
0..15)
18
2
PUPDR8
Port x configuration bits (y =
0..15)
16
2
PUPDR7
Port x configuration bits (y =
0..15)
14
2
PUPDR6
Port x configuration bits (y =
0..15)
12
2
PUPDR5
Port x configuration bits (y =
0..15)
10
2
PUPDR4
Port x configuration bits (y =
0..15)
8
2
PUPDR3
Port x configuration bits (y =
0..15)
6
2
PUPDR2
Port x configuration bits (y =
0..15)
4
2
PUPDR1
Port x configuration bits (y =
0..15)
2
2
PUPDR0
Port x configuration bits (y =
0..15)
0
2
IDR
IDR
GPIO port input data register
0x10
0x20
read-only
0x00000000
IDR15
Port input data (y =
0..15)
15
1
IDR14
Port input data (y =
0..15)
14
1
IDR13
Port input data (y =
0..15)
13
1
IDR12
Port input data (y =
0..15)
12
1
IDR11
Port input data (y =
0..15)
11
1
IDR10
Port input data (y =
0..15)
10
1
IDR9
Port input data (y =
0..15)
9
1
IDR8
Port input data (y =
0..15)
8
1
IDR7
Port input data (y =
0..15)
7
1
IDR6
Port input data (y =
0..15)
6
1
IDR5
Port input data (y =
0..15)
5
1
IDR4
Port input data (y =
0..15)
4
1
IDR3
Port input data (y =
0..15)
3
1
IDR2
Port input data (y =
0..15)
2
1
IDR1
Port input data (y =
0..15)
1
1
IDR0
Port input data (y =
0..15)
0
1
ODR
ODR
GPIO port output data register
0x14
0x20
read-write
0x00000000
ODR15
Port output data (y =
0..15)
15
1
ODR14
Port output data (y =
0..15)
14
1
ODR13
Port output data (y =
0..15)
13
1
ODR12
Port output data (y =
0..15)
12
1
ODR11
Port output data (y =
0..15)
11
1
ODR10
Port output data (y =
0..15)
10
1
ODR9
Port output data (y =
0..15)
9
1
ODR8
Port output data (y =
0..15)
8
1
ODR7
Port output data (y =
0..15)
7
1
ODR6
Port output data (y =
0..15)
6
1
ODR5
Port output data (y =
0..15)
5
1
ODR4
Port output data (y =
0..15)
4
1
ODR3
Port output data (y =
0..15)
3
1
ODR2
Port output data (y =
0..15)
2
1
ODR1
Port output data (y =
0..15)
1
1
ODR0
Port output data (y =
0..15)
0
1
BSRR
BSRR
GPIO port bit set/reset
register
0x18
0x20
write-only
0x00000000
BR15
Port x reset bit y (y =
0..15)
31
1
BR14
Port x reset bit y (y =
0..15)
30
1
BR13
Port x reset bit y (y =
0..15)
29
1
BR12
Port x reset bit y (y =
0..15)
28
1
BR11
Port x reset bit y (y =
0..15)
27
1
BR10
Port x reset bit y (y =
0..15)
26
1
BR9
Port x reset bit y (y =
0..15)
25
1
BR8
Port x reset bit y (y =
0..15)
24
1
BR7
Port x reset bit y (y =
0..15)
23
1
BR6
Port x reset bit y (y =
0..15)
22
1
BR5
Port x reset bit y (y =
0..15)
21
1
BR4
Port x reset bit y (y =
0..15)
20
1
BR3
Port x reset bit y (y =
0..15)
19
1
BR2
Port x reset bit y (y =
0..15)
18
1
BR1
Port x reset bit y (y =
0..15)
17
1
BR0
Port x set bit y (y=
0..15)
16
1
BS15
Port x set bit y (y=
0..15)
15
1
BS14
Port x set bit y (y=
0..15)
14
1
BS13
Port x set bit y (y=
0..15)
13
1
BS12
Port x set bit y (y=
0..15)
12
1
BS11
Port x set bit y (y=
0..15)
11
1
BS10
Port x set bit y (y=
0..15)
10
1
BS9
Port x set bit y (y=
0..15)
9
1
BS8
Port x set bit y (y=
0..15)
8
1
BS7
Port x set bit y (y=
0..15)
7
1
BS6
Port x set bit y (y=
0..15)
6
1
BS5
Port x set bit y (y=
0..15)
5
1
BS4
Port x set bit y (y=
0..15)
4
1
BS3
Port x set bit y (y=
0..15)
3
1
BS2
Port x set bit y (y=
0..15)
2
1
BS1
Port x set bit y (y=
0..15)
1
1
BS0
Port x set bit y (y=
0..15)
0
1
LCKR
LCKR
GPIO port configuration lock
register
0x1C
0x20
read-write
0x00000000
LCKK
Port x lock bit y (y=
0..15)
16
1
LCK15
Port x lock bit y (y=
0..15)
15
1
LCK14
Port x lock bit y (y=
0..15)
14
1
LCK13
Port x lock bit y (y=
0..15)
13
1
LCK12
Port x lock bit y (y=
0..15)
12
1
LCK11
Port x lock bit y (y=
0..15)
11
1
LCK10
Port x lock bit y (y=
0..15)
10
1
LCK9
Port x lock bit y (y=
0..15)
9
1
LCK8
Port x lock bit y (y=
0..15)
8
1
LCK7
Port x lock bit y (y=
0..15)
7
1
LCK6
Port x lock bit y (y=
0..15)
6
1
LCK5
Port x lock bit y (y=
0..15)
5
1
LCK4
Port x lock bit y (y=
0..15)
4
1
LCK3
Port x lock bit y (y=
0..15)
3
1
LCK2
Port x lock bit y (y=
0..15)
2
1
LCK1
Port x lock bit y (y=
0..15)
1
1
LCK0
Port x lock bit y (y=
0..15)
0
1
AFRL
AFRL
GPIO alternate function low
register
0x20
0x20
read-write
0x00000000
AFRL7
Alternate function selection for port x
bit y (y = 0..7)
28
4
AFRL6
Alternate function selection for port x
bit y (y = 0..7)
24
4
AFRL5
Alternate function selection for port x
bit y (y = 0..7)
20
4
AFRL4
Alternate function selection for port x
bit y (y = 0..7)
16
4
AFRL3
Alternate function selection for port x
bit y (y = 0..7)
12
4
AFRL2
Alternate function selection for port x
bit y (y = 0..7)
8
4
AFRL1
Alternate function selection for port x
bit y (y = 0..7)
4
4
AFRL0
Alternate function selection for port x
bit y (y = 0..7)
0
4
AFRH
AFRH
GPIO alternate function high
register
0x24
0x20
read-write
0x00000000
AFRH15
Alternate function selection for port x
bit y (y = 8..15)
28
4
AFRH14
Alternate function selection for port x
bit y (y = 8..15)
24
4
AFRH13
Alternate function selection for port x
bit y (y = 8..15)
20
4
AFRH12
Alternate function selection for port x
bit y (y = 8..15)
16
4
AFRH11
Alternate function selection for port x
bit y (y = 8..15)
12
4
AFRH10
Alternate function selection for port x
bit y (y = 8..15)
8
4
AFRH9
Alternate function selection for port x
bit y (y = 8..15)
4
4
AFRH8
Alternate function selection for port x
bit y (y = 8..15)
0
4
BRR
BRR
GPIO port bit reset register
0x28
0x20
write-only
0x00000000
BR0
Port Reset bit
0
1
BR1
Port Reset bit
1
1
BR2
Port Reset bit
2
1
BR3
Port Reset bit
3
1
BR4
Port Reset bit
4
1
BR5
Port Reset bit
5
1
BR6
Port Reset bit
6
1
BR7
Port Reset bit
7
1
BR8
Port Reset bit
8
1
BR9
Port Reset bit
9
1
BR10
Port Reset bit
10
1
BR11
Port Reset bit
11
1
BR12
Port Reset bit
12
1
BR13
Port Reset bit
13
1
BR14
Port Reset bit
14
1
BR15
Port Reset bit
15
1
ASCR
ASCR
GPIO port analog switch control
register
0x2C
0x20
read-write
0x00000000
ASC0
Port analog switch control
0
1
ASC1
Port analog switch control
1
1
ASC2
Port analog switch control
2
1
ASC3
Port analog switch control
3
1
ASC4
Port analog switch control
4
1
ASC5
Port analog switch control
5
1
ASC6
Port analog switch control
6
1
ASC7
Port analog switch control
7
1
ASC8
Port analog switch control
8
1
ASC9
Port analog switch control
9
1
ASC10
Port analog switch control
10
1
ASC11
Port analog switch control
11
1
ASC12
Port analog switch control
12
1
ASC13
Port analog switch control
13
1
ASC14
Port analog switch control
14
1
ASC15
Port analog switch control
15
1
GPIOB
General-purpose I/Os
GPIO
0x48000400
0x0
0x400
registers
MODER
MODER
GPIO port mode register
0x0
0x20
read-write
0x00000280
MODER15
Port x configuration bits (y =
0..15)
30
2
MODER14
Port x configuration bits (y =
0..15)
28
2
MODER13
Port x configuration bits (y =
0..15)
26
2
MODER12
Port x configuration bits (y =
0..15)
24
2
MODER11
Port x configuration bits (y =
0..15)
22
2
MODER10
Port x configuration bits (y =
0..15)
20
2
MODER9
Port x configuration bits (y =
0..15)
18
2
MODER8
Port x configuration bits (y =
0..15)
16
2
MODER7
Port x configuration bits (y =
0..15)
14
2
MODER6
Port x configuration bits (y =
0..15)
12
2
MODER5
Port x configuration bits (y =
0..15)
10
2
MODER4
Port x configuration bits (y =
0..15)
8
2
MODER3
Port x configuration bits (y =
0..15)
6
2
MODER2
Port x configuration bits (y =
0..15)
4
2
MODER1
Port x configuration bits (y =
0..15)
2
2
MODER0
Port x configuration bits (y =
0..15)
0
2
OTYPER
OTYPER
GPIO port output type register
0x4
0x20
read-write
0x00000000
OT15
Port x configuration bits (y =
0..15)
15
1
OT14
Port x configuration bits (y =
0..15)
14
1
OT13
Port x configuration bits (y =
0..15)
13
1
OT12
Port x configuration bits (y =
0..15)
12
1
OT11
Port x configuration bits (y =
0..15)
11
1
OT10
Port x configuration bits (y =
0..15)
10
1
OT9
Port x configuration bits (y =
0..15)
9
1
OT8
Port x configuration bits (y =
0..15)
8
1
OT7
Port x configuration bits (y =
0..15)
7
1
OT6
Port x configuration bits (y =
0..15)
6
1
OT5
Port x configuration bits (y =
0..15)
5
1
OT4
Port x configuration bits (y =
0..15)
4
1
OT3
Port x configuration bits (y =
0..15)
3
1
OT2
Port x configuration bits (y =
0..15)
2
1
OT1
Port x configuration bits (y =
0..15)
1
1
OT0
Port x configuration bits (y =
0..15)
0
1
OSPEEDR
OSPEEDR
GPIO port output speed
register
0x8
0x20
read-write
0x000000C0
OSPEEDR15
Port x configuration bits (y =
0..15)
30
2
OSPEEDR14
Port x configuration bits (y =
0..15)
28
2
OSPEEDR13
Port x configuration bits (y =
0..15)
26
2
OSPEEDR12
Port x configuration bits (y =
0..15)
24
2
OSPEEDR11
Port x configuration bits (y =
0..15)
22
2
OSPEEDR10
Port x configuration bits (y =
0..15)
20
2
OSPEEDR9
Port x configuration bits (y =
0..15)
18
2
OSPEEDR8
Port x configuration bits (y =
0..15)
16
2
OSPEEDR7
Port x configuration bits (y =
0..15)
14
2
OSPEEDR6
Port x configuration bits (y =
0..15)
12
2
OSPEEDR5
Port x configuration bits (y =
0..15)
10
2
OSPEEDR4
Port x configuration bits (y =
0..15)
8
2
OSPEEDR3
Port x configuration bits (y =
0..15)
6
2
OSPEEDR2
Port x configuration bits (y =
0..15)
4
2
OSPEEDR1
Port x configuration bits (y =
0..15)
2
2
OSPEEDR0
Port x configuration bits (y =
0..15)
0
2
PUPDR
PUPDR
GPIO port pull-up/pull-down
register
0xC
0x20
read-write
0x00000100
PUPDR15
Port x configuration bits (y =
0..15)
30
2
PUPDR14
Port x configuration bits (y =
0..15)
28
2
PUPDR13
Port x configuration bits (y =
0..15)
26
2
PUPDR12
Port x configuration bits (y =
0..15)
24
2
PUPDR11
Port x configuration bits (y =
0..15)
22
2
PUPDR10
Port x configuration bits (y =
0..15)
20
2
PUPDR9
Port x configuration bits (y =
0..15)
18
2
PUPDR8
Port x configuration bits (y =
0..15)
16
2
PUPDR7
Port x configuration bits (y =
0..15)
14
2
PUPDR6
Port x configuration bits (y =
0..15)
12
2
PUPDR5
Port x configuration bits (y =
0..15)
10
2
PUPDR4
Port x configuration bits (y =
0..15)
8
2
PUPDR3
Port x configuration bits (y =
0..15)
6
2
PUPDR2
Port x configuration bits (y =
0..15)
4
2
PUPDR1
Port x configuration bits (y =
0..15)
2
2
PUPDR0
Port x configuration bits (y =
0..15)
0
2
IDR
IDR
GPIO port input data register
0x10
0x20
read-only
0x00000000
IDR15
Port input data (y =
0..15)
15
1
IDR14
Port input data (y =
0..15)
14
1
IDR13
Port input data (y =
0..15)
13
1
IDR12
Port input data (y =
0..15)
12
1
IDR11
Port input data (y =
0..15)
11
1
IDR10
Port input data (y =
0..15)
10
1
IDR9
Port input data (y =
0..15)
9
1
IDR8
Port input data (y =
0..15)
8
1
IDR7
Port input data (y =
0..15)
7
1
IDR6
Port input data (y =
0..15)
6
1
IDR5
Port input data (y =
0..15)
5
1
IDR4
Port input data (y =
0..15)
4
1
IDR3
Port input data (y =
0..15)
3
1
IDR2
Port input data (y =
0..15)
2
1
IDR1
Port input data (y =
0..15)
1
1
IDR0
Port input data (y =
0..15)
0
1
ODR
ODR
GPIO port output data register
0x14
0x20
read-write
0x00000000
ODR15
Port output data (y =
0..15)
15
1
ODR14
Port output data (y =
0..15)
14
1
ODR13
Port output data (y =
0..15)
13
1
ODR12
Port output data (y =
0..15)
12
1
ODR11
Port output data (y =
0..15)
11
1
ODR10
Port output data (y =
0..15)
10
1
ODR9
Port output data (y =
0..15)
9
1
ODR8
Port output data (y =
0..15)
8
1
ODR7
Port output data (y =
0..15)
7
1
ODR6
Port output data (y =
0..15)
6
1
ODR5
Port output data (y =
0..15)
5
1
ODR4
Port output data (y =
0..15)
4
1
ODR3
Port output data (y =
0..15)
3
1
ODR2
Port output data (y =
0..15)
2
1
ODR1
Port output data (y =
0..15)
1
1
ODR0
Port output data (y =
0..15)
0
1
BSRR
BSRR
GPIO port bit set/reset
register
0x18
0x20
write-only
0x00000000
BR15
Port x reset bit y (y =
0..15)
31
1
BR14
Port x reset bit y (y =
0..15)
30
1
BR13
Port x reset bit y (y =
0..15)
29
1
BR12
Port x reset bit y (y =
0..15)
28
1
BR11
Port x reset bit y (y =
0..15)
27
1
BR10
Port x reset bit y (y =
0..15)
26
1
BR9
Port x reset bit y (y =
0..15)
25
1
BR8
Port x reset bit y (y =
0..15)
24
1
BR7
Port x reset bit y (y =
0..15)
23
1
BR6
Port x reset bit y (y =
0..15)
22
1
BR5
Port x reset bit y (y =
0..15)
21
1
BR4
Port x reset bit y (y =
0..15)
20
1
BR3
Port x reset bit y (y =
0..15)
19
1
BR2
Port x reset bit y (y =
0..15)
18
1
BR1
Port x reset bit y (y =
0..15)
17
1
BR0
Port x set bit y (y=
0..15)
16
1
BS15
Port x set bit y (y=
0..15)
15
1
BS14
Port x set bit y (y=
0..15)
14
1
BS13
Port x set bit y (y=
0..15)
13
1
BS12
Port x set bit y (y=
0..15)
12
1
BS11
Port x set bit y (y=
0..15)
11
1
BS10
Port x set bit y (y=
0..15)
10
1
BS9
Port x set bit y (y=
0..15)
9
1
BS8
Port x set bit y (y=
0..15)
8
1
BS7
Port x set bit y (y=
0..15)
7
1
BS6
Port x set bit y (y=
0..15)
6
1
BS5
Port x set bit y (y=
0..15)
5
1
BS4
Port x set bit y (y=
0..15)
4
1
BS3
Port x set bit y (y=
0..15)
3
1
BS2
Port x set bit y (y=
0..15)
2
1
BS1
Port x set bit y (y=
0..15)
1
1
BS0
Port x set bit y (y=
0..15)
0
1
LCKR
LCKR
GPIO port configuration lock
register
0x1C
0x20
read-write
0x00000000
LCKK
Port x lock bit y (y=
0..15)
16
1
LCK15
Port x lock bit y (y=
0..15)
15
1
LCK14
Port x lock bit y (y=
0..15)
14
1
LCK13
Port x lock bit y (y=
0..15)
13
1
LCK12
Port x lock bit y (y=
0..15)
12
1
LCK11
Port x lock bit y (y=
0..15)
11
1
LCK10
Port x lock bit y (y=
0..15)
10
1
LCK9
Port x lock bit y (y=
0..15)
9
1
LCK8
Port x lock bit y (y=
0..15)
8
1
LCK7
Port x lock bit y (y=
0..15)
7
1
LCK6
Port x lock bit y (y=
0..15)
6
1
LCK5
Port x lock bit y (y=
0..15)
5
1
LCK4
Port x lock bit y (y=
0..15)
4
1
LCK3
Port x lock bit y (y=
0..15)
3
1
LCK2
Port x lock bit y (y=
0..15)
2
1
LCK1
Port x lock bit y (y=
0..15)
1
1
LCK0
Port x lock bit y (y=
0..15)
0
1
AFRL
AFRL
GPIO alternate function low
register
0x20
0x20
read-write
0x00000000
AFRL7
Alternate function selection for port x
bit y (y = 0..7)
28
4
AFRL6
Alternate function selection for port x
bit y (y = 0..7)
24
4
AFRL5
Alternate function selection for port x
bit y (y = 0..7)
20
4
AFRL4
Alternate function selection for port x
bit y (y = 0..7)
16
4
AFRL3
Alternate function selection for port x
bit y (y = 0..7)
12
4
AFRL2
Alternate function selection for port x
bit y (y = 0..7)
8
4
AFRL1
Alternate function selection for port x
bit y (y = 0..7)
4
4
AFRL0
Alternate function selection for port x
bit y (y = 0..7)
0
4
AFRH
AFRH
GPIO alternate function high
register
0x24
0x20
read-write
0x00000000
AFRH15
Alternate function selection for port x
bit y (y = 8..15)
28
4
AFRH14
Alternate function selection for port x
bit y (y = 8..15)
24
4
AFRH13
Alternate function selection for port x
bit y (y = 8..15)
20
4
AFRH12
Alternate function selection for port x
bit y (y = 8..15)
16
4
AFRH11
Alternate function selection for port x
bit y (y = 8..15)
12
4
AFRH10
Alternate function selection for port x
bit y (y = 8..15)
8
4
AFRH9
Alternate function selection for port x
bit y (y = 8..15)
4
4
AFRH8
Alternate function selection for port x
bit y (y = 8..15)
0
4
BRR
BRR
GPIO port bit reset register
0x28
0x20
write-only
0x00000000
BR0
Port Reset bit
0
1
BR1
Port Reset bit
1
1
BR2
Port Reset bit
2
1
BR3
Port Reset bit
3
1
BR4
Port Reset bit
4
1
BR5
Port Reset bit
5
1
BR6
Port Reset bit
6
1
BR7
Port Reset bit
7
1
BR8
Port Reset bit
8
1
BR9
Port Reset bit
9
1
BR10
Port Reset bit
10
1
BR11
Port Reset bit
11
1
BR12
Port Reset bit
12
1
BR13
Port Reset bit
13
1
BR14
Port Reset bit
14
1
BR15
Port Reset bit
15
1
ASCR
ASCR
GPIO port analog switch control
register
0x2C
0x20
read-write
0x00000000
ASC0
Port analog switch control
0
1
ASC1
Port analog switch control
1
1
ASC2
Port analog switch control
2
1
ASC3
Port analog switch control
3
1
ASC4
Port analog switch control
4
1
ASC5
Port analog switch control
5
1
ASC6
Port analog switch control
6
1
ASC7
Port analog switch control
7
1
ASC8
Port analog switch control
8
1
ASC9
Port analog switch control
9
1
ASC10
Port analog switch control
10
1
ASC11
Port analog switch control
11
1
ASC12
Port analog switch control
12
1
ASC13
Port analog switch control
13
1
ASC14
Port analog switch control
14
1
ASC15
Port analog switch control
15
1
GPIOC
General-purpose I/Os
GPIO
0x48000800
0x0
0x400
registers
MODER
MODER
GPIO port mode register
0x0
0x20
read-write
0x00000000
MODER15
Port x configuration bits (y =
0..15)
30
2
MODER14
Port x configuration bits (y =
0..15)
28
2
MODER13
Port x configuration bits (y =
0..15)
26
2
MODER12
Port x configuration bits (y =
0..15)
24
2
MODER11
Port x configuration bits (y =
0..15)
22
2
MODER10
Port x configuration bits (y =
0..15)
20
2
MODER9
Port x configuration bits (y =
0..15)
18
2
MODER8
Port x configuration bits (y =
0..15)
16
2
MODER7
Port x configuration bits (y =
0..15)
14
2
MODER6
Port x configuration bits (y =
0..15)
12
2
MODER5
Port x configuration bits (y =
0..15)
10
2
MODER4
Port x configuration bits (y =
0..15)
8
2
MODER3
Port x configuration bits (y =
0..15)
6
2
MODER2
Port x configuration bits (y =
0..15)
4
2
MODER1
Port x configuration bits (y =
0..15)
2
2
MODER0
Port x configuration bits (y =
0..15)
0
2
OTYPER
OTYPER
GPIO port output type register
0x4
0x20
read-write
0x00000000
OT15
Port x configuration bits (y =
0..15)
15
1
OT14
Port x configuration bits (y =
0..15)
14
1
OT13
Port x configuration bits (y =
0..15)
13
1
OT12
Port x configuration bits (y =
0..15)
12
1
OT11
Port x configuration bits (y =
0..15)
11
1
OT10
Port x configuration bits (y =
0..15)
10
1
OT9
Port x configuration bits (y =
0..15)
9
1
OT8
Port x configuration bits (y =
0..15)
8
1
OT7
Port x configuration bits (y =
0..15)
7
1
OT6
Port x configuration bits (y =
0..15)
6
1
OT5
Port x configuration bits (y =
0..15)
5
1
OT4
Port x configuration bits (y =
0..15)
4
1
OT3
Port x configuration bits (y =
0..15)
3
1
OT2
Port x configuration bits (y =
0..15)
2
1
OT1
Port x configuration bits (y =
0..15)
1
1
OT0
Port x configuration bits (y =
0..15)
0
1
OSPEEDR
OSPEEDR
GPIO port output speed
register
0x8
0x20
read-write
0x00000000
OSPEEDR15
Port x configuration bits (y =
0..15)
30
2
OSPEEDR14
Port x configuration bits (y =
0..15)
28
2
OSPEEDR13
Port x configuration bits (y =
0..15)
26
2
OSPEEDR12
Port x configuration bits (y =
0..15)
24
2
OSPEEDR11
Port x configuration bits (y =
0..15)
22
2
OSPEEDR10
Port x configuration bits (y =
0..15)
20
2
OSPEEDR9
Port x configuration bits (y =
0..15)
18
2
OSPEEDR8
Port x configuration bits (y =
0..15)
16
2
OSPEEDR7
Port x configuration bits (y =
0..15)
14
2
OSPEEDR6
Port x configuration bits (y =
0..15)
12
2
OSPEEDR5
Port x configuration bits (y =
0..15)
10
2
OSPEEDR4
Port x configuration bits (y =
0..15)
8
2
OSPEEDR3
Port x configuration bits (y =
0..15)
6
2
OSPEEDR2
Port x configuration bits (y =
0..15)
4
2
OSPEEDR1
Port x configuration bits (y =
0..15)
2
2
OSPEEDR0
Port x configuration bits (y =
0..15)
0
2
PUPDR
PUPDR
GPIO port pull-up/pull-down
register
0xC
0x20
read-write
0x00000000
PUPDR15
Port x configuration bits (y =
0..15)
30
2
PUPDR14
Port x configuration bits (y =
0..15)
28
2
PUPDR13
Port x configuration bits (y =
0..15)
26
2
PUPDR12
Port x configuration bits (y =
0..15)
24
2
PUPDR11
Port x configuration bits (y =
0..15)
22
2
PUPDR10
Port x configuration bits (y =
0..15)
20
2
PUPDR9
Port x configuration bits (y =
0..15)
18
2
PUPDR8
Port x configuration bits (y =
0..15)
16
2
PUPDR7
Port x configuration bits (y =
0..15)
14
2
PUPDR6
Port x configuration bits (y =
0..15)
12
2
PUPDR5
Port x configuration bits (y =
0..15)
10
2
PUPDR4
Port x configuration bits (y =
0..15)
8
2
PUPDR3
Port x configuration bits (y =
0..15)
6
2
PUPDR2
Port x configuration bits (y =
0..15)
4
2
PUPDR1
Port x configuration bits (y =
0..15)
2
2
PUPDR0
Port x configuration bits (y =
0..15)
0
2
IDR
IDR
GPIO port input data register
0x10
0x20
read-only
0x00000000
IDR15
Port input data (y =
0..15)
15
1
IDR14
Port input data (y =
0..15)
14
1
IDR13
Port input data (y =
0..15)
13
1
IDR12
Port input data (y =
0..15)
12
1
IDR11
Port input data (y =
0..15)
11
1
IDR10
Port input data (y =
0..15)
10
1
IDR9
Port input data (y =
0..15)
9
1
IDR8
Port input data (y =
0..15)
8
1
IDR7
Port input data (y =
0..15)
7
1
IDR6
Port input data (y =
0..15)
6
1
IDR5
Port input data (y =
0..15)
5
1
IDR4
Port input data (y =
0..15)
4
1
IDR3
Port input data (y =
0..15)
3
1
IDR2
Port input data (y =
0..15)
2
1
IDR1
Port input data (y =
0..15)
1
1
IDR0
Port input data (y =
0..15)
0
1
ODR
ODR
GPIO port output data register
0x14
0x20
read-write
0x00000000
ODR15
Port output data (y =
0..15)
15
1
ODR14
Port output data (y =
0..15)
14
1
ODR13
Port output data (y =
0..15)
13
1
ODR12
Port output data (y =
0..15)
12
1
ODR11
Port output data (y =
0..15)
11
1
ODR10
Port output data (y =
0..15)
10
1
ODR9
Port output data (y =
0..15)
9
1
ODR8
Port output data (y =
0..15)
8
1
ODR7
Port output data (y =
0..15)
7
1
ODR6
Port output data (y =
0..15)
6
1
ODR5
Port output data (y =
0..15)
5
1
ODR4
Port output data (y =
0..15)
4
1
ODR3
Port output data (y =
0..15)
3
1
ODR2
Port output data (y =
0..15)
2
1
ODR1
Port output data (y =
0..15)
1
1
ODR0
Port output data (y =
0..15)
0
1
BSRR
BSRR
GPIO port bit set/reset
register
0x18
0x20
write-only
0x00000000
BR15
Port x reset bit y (y =
0..15)
31
1
BR14
Port x reset bit y (y =
0..15)
30
1
BR13
Port x reset bit y (y =
0..15)
29
1
BR12
Port x reset bit y (y =
0..15)
28
1
BR11
Port x reset bit y (y =
0..15)
27
1
BR10
Port x reset bit y (y =
0..15)
26
1
BR9
Port x reset bit y (y =
0..15)
25
1
BR8
Port x reset bit y (y =
0..15)
24
1
BR7
Port x reset bit y (y =
0..15)
23
1
BR6
Port x reset bit y (y =
0..15)
22
1
BR5
Port x reset bit y (y =
0..15)
21
1
BR4
Port x reset bit y (y =
0..15)
20
1
BR3
Port x reset bit y (y =
0..15)
19
1
BR2
Port x reset bit y (y =
0..15)
18
1
BR1
Port x reset bit y (y =
0..15)
17
1
BR0
Port x set bit y (y=
0..15)
16
1
BS15
Port x set bit y (y=
0..15)
15
1
BS14
Port x set bit y (y=
0..15)
14
1
BS13
Port x set bit y (y=
0..15)
13
1
BS12
Port x set bit y (y=
0..15)
12
1
BS11
Port x set bit y (y=
0..15)
11
1
BS10
Port x set bit y (y=
0..15)
10
1
BS9
Port x set bit y (y=
0..15)
9
1
BS8
Port x set bit y (y=
0..15)
8
1
BS7
Port x set bit y (y=
0..15)
7
1
BS6
Port x set bit y (y=
0..15)
6
1
BS5
Port x set bit y (y=
0..15)
5
1
BS4
Port x set bit y (y=
0..15)
4
1
BS3
Port x set bit y (y=
0..15)
3
1
BS2
Port x set bit y (y=
0..15)
2
1
BS1
Port x set bit y (y=
0..15)
1
1
BS0
Port x set bit y (y=
0..15)
0
1
LCKR
LCKR
GPIO port configuration lock
register
0x1C
0x20
read-write
0x00000000
LCKK
Port x lock bit y (y=
0..15)
16
1
LCK15
Port x lock bit y (y=
0..15)
15
1
LCK14
Port x lock bit y (y=
0..15)
14
1
LCK13
Port x lock bit y (y=
0..15)
13
1
LCK12
Port x lock bit y (y=
0..15)
12
1
LCK11
Port x lock bit y (y=
0..15)
11
1
LCK10
Port x lock bit y (y=
0..15)
10
1
LCK9
Port x lock bit y (y=
0..15)
9
1
LCK8
Port x lock bit y (y=
0..15)
8
1
LCK7
Port x lock bit y (y=
0..15)
7
1
LCK6
Port x lock bit y (y=
0..15)
6
1
LCK5
Port x lock bit y (y=
0..15)
5
1
LCK4
Port x lock bit y (y=
0..15)
4
1
LCK3
Port x lock bit y (y=
0..15)
3
1
LCK2
Port x lock bit y (y=
0..15)
2
1
LCK1
Port x lock bit y (y=
0..15)
1
1
LCK0
Port x lock bit y (y=
0..15)
0
1
AFRL
AFRL
GPIO alternate function low
register
0x20
0x20
read-write
0x00000000
AFRL7
Alternate function selection for port x
bit y (y = 0..7)
28
4
AFRL6
Alternate function selection for port x
bit y (y = 0..7)
24
4
AFRL5
Alternate function selection for port x
bit y (y = 0..7)
20
4
AFRL4
Alternate function selection for port x
bit y (y = 0..7)
16
4
AFRL3
Alternate function selection for port x
bit y (y = 0..7)
12
4
AFRL2
Alternate function selection for port x
bit y (y = 0..7)
8
4
AFRL1
Alternate function selection for port x
bit y (y = 0..7)
4
4
AFRL0
Alternate function selection for port x
bit y (y = 0..7)
0
4
AFRH
AFRH
GPIO alternate function high
register
0x24
0x20
read-write
0x00000000
AFRH15
Alternate function selection for port x
bit y (y = 8..15)
28
4
AFRH14
Alternate function selection for port x
bit y (y = 8..15)
24
4
AFRH13
Alternate function selection for port x
bit y (y = 8..15)
20
4
AFRH12
Alternate function selection for port x
bit y (y = 8..15)
16
4
AFRH11
Alternate function selection for port x
bit y (y = 8..15)
12
4
AFRH10
Alternate function selection for port x
bit y (y = 8..15)
8
4
AFRH9
Alternate function selection for port x
bit y (y = 8..15)
4
4
AFRH8
Alternate function selection for port x
bit y (y = 8..15)
0
4
BRR
BRR
GPIO port bit reset register
0x28
0x20
write-only
0x00000000
BR0
Port Reset bit
0
1
BR1
Port Reset bit
1
1
BR2
Port Reset bit
2
1
BR3
Port Reset bit
3
1
BR4
Port Reset bit
4
1
BR5
Port Reset bit
5
1
BR6
Port Reset bit
6
1
BR7
Port Reset bit
7
1
BR8
Port Reset bit
8
1
BR9
Port Reset bit
9
1
BR10
Port Reset bit
10
1
BR11
Port Reset bit
11
1
BR12
Port Reset bit
12
1
BR13
Port Reset bit
13
1
BR14
Port Reset bit
14
1
BR15
Port Reset bit
15
1
ASCR
ASCR
GPIO port analog switch control
register
0x2C
0x20
read-write
0x00000000
ASC0
Port analog switch control
0
1
ASC1
Port analog switch control
1
1
ASC2
Port analog switch control
2
1
ASC3
Port analog switch control
3
1
ASC4
Port analog switch control
4
1
ASC5
Port analog switch control
5
1
ASC6
Port analog switch control
6
1
ASC7
Port analog switch control
7
1
ASC8
Port analog switch control
8
1
ASC9
Port analog switch control
9
1
ASC10
Port analog switch control
10
1
ASC11
Port analog switch control
11
1
ASC12
Port analog switch control
12
1
ASC13
Port analog switch control
13
1
ASC14
Port analog switch control
14
1
ASC15
Port analog switch control
15
1
GPIOD
0x48000C00
GPIOE
0x48001000
GPIOF
0x48001400
GPIOG
0x48001800
GPIOH
0x48001C00
GPIOI
General-purpose I/Os
GPIO
0x48002000
0x0
0x400
registers
MODER
MODER
GPIO port mode register
0x0
0x20
read-write
0x00000000
MODER15
Port x configuration bits (y =
0..15)
30
2
MODER14
Port x configuration bits (y =
0..15)
28
2
MODER13
Port x configuration bits (y =
0..15)
26
2
MODER12
Port x configuration bits (y =
0..15)
24
2
MODER11
Port x configuration bits (y =
0..15)
22
2
MODER10
Port x configuration bits (y =
0..15)
20
2
MODER9
Port x configuration bits (y =
0..15)
18
2
MODER8
Port x configuration bits (y =
0..15)
16
2
MODER7
Port x configuration bits (y =
0..15)
14
2
MODER6
Port x configuration bits (y =
0..15)
12
2
MODER5
Port x configuration bits (y =
0..15)
10
2
MODER4
Port x configuration bits (y =
0..15)
8
2
MODER3
Port x configuration bits (y =
0..15)
6
2
MODER2
Port x configuration bits (y =
0..15)
4
2
MODER1
Port x configuration bits (y =
0..15)
2
2
MODER0
Port x configuration bits (y =
0..15)
0
2
OTYPER
OTYPER
GPIO port output type register
0x4
0x20
read-write
0x00000000
OT15
Port x configuration bits (y =
0..15)
15
1
OT14
Port x configuration bits (y =
0..15)
14
1
OT13
Port x configuration bits (y =
0..15)
13
1
OT12
Port x configuration bits (y =
0..15)
12
1
OT11
Port x configuration bits (y =
0..15)
11
1
OT10
Port x configuration bits (y =
0..15)
10
1
OT9
Port x configuration bits (y =
0..15)
9
1
OT8
Port x configuration bits (y =
0..15)
8
1
OT7
Port x configuration bits (y =
0..15)
7
1
OT6
Port x configuration bits (y =
0..15)
6
1
OT5
Port x configuration bits (y =
0..15)
5
1
OT4
Port x configuration bits (y =
0..15)
4
1
OT3
Port x configuration bits (y =
0..15)
3
1
OT2
Port x configuration bits (y =
0..15)
2
1
OT1
Port x configuration bits (y =
0..15)
1
1
OT0
Port x configuration bits (y =
0..15)
0
1
OSPEEDR
OSPEEDR
GPIO port output speed
register
0x8
0x20
read-write
0x00000000
OSPEEDR15
Port x configuration bits (y =
0..15)
30
2
OSPEEDR14
Port x configuration bits (y =
0..15)
28
2
OSPEEDR13
Port x configuration bits (y =
0..15)
26
2
OSPEEDR12
Port x configuration bits (y =
0..15)
24
2
OSPEEDR11
Port x configuration bits (y =
0..15)
22
2
OSPEEDR10
Port x configuration bits (y =
0..15)
20
2
OSPEEDR9
Port x configuration bits (y =
0..15)
18
2
OSPEEDR8
Port x configuration bits (y =
0..15)
16
2
OSPEEDR7
Port x configuration bits (y =
0..15)
14
2
OSPEEDR6
Port x configuration bits (y =
0..15)
12
2
OSPEEDR5
Port x configuration bits (y =
0..15)
10
2
OSPEEDR4
Port x configuration bits (y =
0..15)
8
2
OSPEEDR3
Port x configuration bits (y =
0..15)
6
2
OSPEEDR2
Port x configuration bits (y =
0..15)
4
2
OSPEEDR1
Port x configuration bits (y =
0..15)
2
2
OSPEEDR0
Port x configuration bits (y =
0..15)
0
2
PUPDR
PUPDR
GPIO port pull-up/pull-down
register
0xC
0x20
read-write
0x00000000
PUPDR15
Port x configuration bits (y =
0..15)
30
2
PUPDR14
Port x configuration bits (y =
0..15)
28
2
PUPDR13
Port x configuration bits (y =
0..15)
26
2
PUPDR12
Port x configuration bits (y =
0..15)
24
2
PUPDR11
Port x configuration bits (y =
0..15)
22
2
PUPDR10
Port x configuration bits (y =
0..15)
20
2
PUPDR9
Port x configuration bits (y =
0..15)
18
2
PUPDR8
Port x configuration bits (y =
0..15)
16
2
PUPDR7
Port x configuration bits (y =
0..15)
14
2
PUPDR6
Port x configuration bits (y =
0..15)
12
2
PUPDR5
Port x configuration bits (y =
0..15)
10
2
PUPDR4
Port x configuration bits (y =
0..15)
8
2
PUPDR3
Port x configuration bits (y =
0..15)
6
2
PUPDR2
Port x configuration bits (y =
0..15)
4
2
PUPDR1
Port x configuration bits (y =
0..15)
2
2
PUPDR0
Port x configuration bits (y =
0..15)
0
2
IDR
IDR
GPIO port input data register
0x10
0x20
read-only
0x00000000
IDR15
Port input data (y =
0..15)
15
1
IDR14
Port input data (y =
0..15)
14
1
IDR13
Port input data (y =
0..15)
13
1
IDR12
Port input data (y =
0..15)
12
1
IDR11
Port input data (y =
0..15)
11
1
IDR10
Port input data (y =
0..15)
10
1
IDR9
Port input data (y =
0..15)
9
1
IDR8
Port input data (y =
0..15)
8
1
IDR7
Port input data (y =
0..15)
7
1
IDR6
Port input data (y =
0..15)
6
1
IDR5
Port input data (y =
0..15)
5
1
IDR4
Port input data (y =
0..15)
4
1
IDR3
Port input data (y =
0..15)
3
1
IDR2
Port input data (y =
0..15)
2
1
IDR1
Port input data (y =
0..15)
1
1
IDR0
Port input data (y =
0..15)
0
1
ODR
ODR
GPIO port output data register
0x14
0x20
read-write
0x00000000
ODR15
Port output data (y =
0..15)
15
1
ODR14
Port output data (y =
0..15)
14
1
ODR13
Port output data (y =
0..15)
13
1
ODR12
Port output data (y =
0..15)
12
1
ODR11
Port output data (y =
0..15)
11
1
ODR10
Port output data (y =
0..15)
10
1
ODR9
Port output data (y =
0..15)
9
1
ODR8
Port output data (y =
0..15)
8
1
ODR7
Port output data (y =
0..15)
7
1
ODR6
Port output data (y =
0..15)
6
1
ODR5
Port output data (y =
0..15)
5
1
ODR4
Port output data (y =
0..15)
4
1
ODR3
Port output data (y =
0..15)
3
1
ODR2
Port output data (y =
0..15)
2
1
ODR1
Port output data (y =
0..15)
1
1
ODR0
Port output data (y =
0..15)
0
1
BSRR
BSRR
GPIO port bit set/reset
register
0x18
0x20
write-only
0x00000000
BR15
Port x reset bit y (y =
0..15)
31
1
BR14
Port x reset bit y (y =
0..15)
30
1
BR13
Port x reset bit y (y =
0..15)
29
1
BR12
Port x reset bit y (y =
0..15)
28
1
BR11
Port x reset bit y (y =
0..15)
27
1
BR10
Port x reset bit y (y =
0..15)
26
1
BR9
Port x reset bit y (y =
0..15)
25
1
BR8
Port x reset bit y (y =
0..15)
24
1
BR7
Port x reset bit y (y =
0..15)
23
1
BR6
Port x reset bit y (y =
0..15)
22
1
BR5
Port x reset bit y (y =
0..15)
21
1
BR4
Port x reset bit y (y =
0..15)
20
1
BR3
Port x reset bit y (y =
0..15)
19
1
BR2
Port x reset bit y (y =
0..15)
18
1
BR1
Port x reset bit y (y =
0..15)
17
1
BR0
Port x set bit y (y=
0..15)
16
1
BS15
Port x set bit y (y=
0..15)
15
1
BS14
Port x set bit y (y=
0..15)
14
1
BS13
Port x set bit y (y=
0..15)
13
1
BS12
Port x set bit y (y=
0..15)
12
1
BS11
Port x set bit y (y=
0..15)
11
1
BS10
Port x set bit y (y=
0..15)
10
1
BS9
Port x set bit y (y=
0..15)
9
1
BS8
Port x set bit y (y=
0..15)
8
1
BS7
Port x set bit y (y=
0..15)
7
1
BS6
Port x set bit y (y=
0..15)
6
1
BS5
Port x set bit y (y=
0..15)
5
1
BS4
Port x set bit y (y=
0..15)
4
1
BS3
Port x set bit y (y=
0..15)
3
1
BS2
Port x set bit y (y=
0..15)
2
1
BS1
Port x set bit y (y=
0..15)
1
1
BS0
Port x set bit y (y=
0..15)
0
1
LCKR
LCKR
GPIO port configuration lock
register
0x1C
0x20
read-write
0x00000000
LCKK
Port x lock bit y (y=
0..15)
16
1
LCK15
Port x lock bit y (y=
0..15)
15
1
LCK14
Port x lock bit y (y=
0..15)
14
1
LCK13
Port x lock bit y (y=
0..15)
13
1
LCK12
Port x lock bit y (y=
0..15)
12
1
LCK11
Port x lock bit y (y=
0..15)
11
1
LCK10
Port x lock bit y (y=
0..15)
10
1
LCK9
Port x lock bit y (y=
0..15)
9
1
LCK8
Port x lock bit y (y=
0..15)
8
1
LCK7
Port x lock bit y (y=
0..15)
7
1
LCK6
Port x lock bit y (y=
0..15)
6
1
LCK5
Port x lock bit y (y=
0..15)
5
1
LCK4
Port x lock bit y (y=
0..15)
4
1
LCK3
Port x lock bit y (y=
0..15)
3
1
LCK2
Port x lock bit y (y=
0..15)
2
1
LCK1
Port x lock bit y (y=
0..15)
1
1
LCK0
Port x lock bit y (y=
0..15)
0
1
AFRL
AFRL
GPIO alternate function low
register
0x20
0x20
read-write
0x00000000
AFRL7
Alternate function selection for port x
bit y (y = 0..7)
28
4
AFRL6
Alternate function selection for port x
bit y (y = 0..7)
24
4
AFRL5
Alternate function selection for port x
bit y (y = 0..7)
20
4
AFRL4
Alternate function selection for port x
bit y (y = 0..7)
16
4
AFRL3
Alternate function selection for port x
bit y (y = 0..7)
12
4
AFRL2
Alternate function selection for port x
bit y (y = 0..7)
8
4
AFRL1
Alternate function selection for port x
bit y (y = 0..7)
4
4
AFRL0
Alternate function selection for port x
bit y (y = 0..7)
0
4
AFRH
AFRH
GPIO alternate function high
register
0x24
0x20
read-write
0x00000000
AFRH15
Alternate function selection for port x
bit y (y = 8..15)
28
4
AFRH14
Alternate function selection for port x
bit y (y = 8..15)
24
4
AFRH13
Alternate function selection for port x
bit y (y = 8..15)
20
4
AFRH12
Alternate function selection for port x
bit y (y = 8..15)
16
4
AFRH11
Alternate function selection for port x
bit y (y = 8..15)
12
4
AFRH10
Alternate function selection for port x
bit y (y = 8..15)
8
4
AFRH9
Alternate function selection for port x
bit y (y = 8..15)
4
4
AFRH8
Alternate function selection for port x
bit y (y = 8..15)
0
4
BRR
BRR
GPIO port bit reset register
0x28
0x20
write-only
0x00000000
BR0
Port Reset bit
0
1
BR1
Port Reset bit
1
1
BR2
Port Reset bit
2
1
BR3
Port Reset bit
3
1
BR4
Port Reset bit
4
1
BR5
Port Reset bit
5
1
BR6
Port Reset bit
6
1
BR7
Port Reset bit
7
1
BR8
Port Reset bit
8
1
BR9
Port Reset bit
9
1
BR10
Port Reset bit
10
1
BR11
Port Reset bit
11
1
BR12
Port Reset bit
12
1
BR13
Port Reset bit
13
1
BR14
Port Reset bit
14
1
BR15
Port Reset bit
15
1
SAI1
Serial audio interface
SAI
0x40015400
0x0
0x400
registers
SAI1
SAI1 global interrupt
74
BCR1
BCR1
BConfiguration register 1
0x24
0x20
read-write
0x00000040
MCJDIV
Master clock divider
20
4
NODIV
No divider
19
1
DMAEN
DMA enable
17
1
SAIBEN
Audio block B enable
16
1
OutDri
Output drive
13
1
MONO
Mono mode
12
1
SYNCEN
Synchronization enable
10
2
CKSTR
Clock strobing edge
9
1
LSBFIRST
Least significant bit
first
8
1
DS
Data size
5
3
PRTCFG
Protocol configuration
2
2
MODE
Audio block mode
0
2
BCR2
BCR2
BConfiguration register 2
0x28
0x20
read-write
0x00000000
COMP
Companding mode
14
2
CPL
Complement bit
13
1
MUTECN
Mute counter
7
6
MUTEVAL
Mute value
6
1
MUTE
Mute
5
1
TRIS
Tristate management on data
line
4
1
FFLUS
FIFO flush
3
1
FTH
FIFO threshold
0
3
BFRCR
BFRCR
BFRCR
0x2C
0x20
read-write
0x00000007
FSOFF
Frame synchronization
offset
18
1
FSPOL
Frame synchronization
polarity
17
1
FSDEF
Frame synchronization
definition
16
1
FSALL
Frame synchronization active level
length
8
7
FRL
Frame length
0
8
BSLOTR
BSLOTR
BSlot register
0x30
0x20
read-write
0x00000000
SLOTEN
Slot enable
16
16
NBSLOT
Number of slots in an audio
frame
8
4
SLOTSZ
Slot size
6
2
FBOFF
First bit offset
0
5
BIM
BIM
BInterrupt mask register2
0x34
0x20
read-write
0x00000000
LFSDETIE
Late frame synchronization detection
interrupt enable
6
1
AFSDETIE
Anticipated frame synchronization
detection interrupt enable
5
1
CNRDYIE
Codec not ready interrupt
enable
4
1
FREQIE
FIFO request interrupt
enable
3
1
WCKCFG
Wrong clock configuration interrupt
enable
2
1
MUTEDET
Mute detection interrupt
enable
1
1
OVRUDRIE
Overrun/underrun interrupt
enable
0
1
BSR
BSR
BStatus register
0x38
0x20
read-only
0x00000000
FLVL
FIFO level threshold
16
3
LFSDET
Late frame synchronization
detection
6
1
AFSDET
Anticipated frame synchronization
detection
5
1
CNRDY
Codec not ready
4
1
FREQ
FIFO request
3
1
WCKCFG
Wrong clock configuration
flag
2
1
MUTEDET
Mute detection
1
1
OVRUDR
Overrun / underrun
0
1
BCLRFR
BCLRFR
BClear flag register
0x3C
0x20
write-only
0x00000000
LFSDET
Clear late frame synchronization
detection flag
6
1
CAFSDET
Clear anticipated frame synchronization
detection flag
5
1
CNRDY
Clear codec not ready flag
4
1
WCKCFG
Clear wrong clock configuration
flag
2
1
MUTEDET
Mute detection flag
1
1
OVRUDR
Clear overrun / underrun
0
1
BDR
BDR
BData register
0x40
0x20
read-write
0x00000000
DATA
Data
0
32
ACR1
ACR1
AConfiguration register 1
0x4
0x20
read-write
0x00000040
MCJDIV
Master clock divider
20
4
NODIV
No divider
19
1
DMAEN
DMA enable
17
1
SAIAEN
Audio block A enable
16
1
OutDri
Output drive
13
1
MONO
Mono mode
12
1
SYNCEN
Synchronization enable
10
2
CKSTR
Clock strobing edge
9
1
LSBFIRST
Least significant bit
first
8
1
DS
Data size
5
3
PRTCFG
Protocol configuration
2
2
MODE
Audio block mode
0
2
ACR2
ACR2
AConfiguration register 2
0x8
0x20
read-write
0x00000000
COMP
Companding mode
14
2
CPL
Complement bit
13
1
MUTECN
Mute counter
7
6
MUTEVAL
Mute value
6
1
MUTE
Mute
5
1
TRIS
Tristate management on data
line
4
1
FFLUS
FIFO flush
3
1
FTH
FIFO threshold
0
3
AFRCR
AFRCR
AFRCR
0xC
0x20
read-write
0x00000007
FSOFF
Frame synchronization
offset
18
1
FSPOL
Frame synchronization
polarity
17
1
FSDEF
Frame synchronization
definition
16
1
FSALL
Frame synchronization active level
length
8
7
FRL
Frame length
0
8
ASLOTR
ASLOTR
ASlot register
0x10
0x20
read-write
0x00000000
SLOTEN
Slot enable
16
16
NBSLOT
Number of slots in an audio
frame
8
4
SLOTSZ
Slot size
6
2
FBOFF
First bit offset
0
5
AIM
AIM
AInterrupt mask register2
0x14
0x20
read-write
0x00000000
LFSDET
Late frame synchronization detection
interrupt enable
6
1
AFSDETIE
Anticipated frame synchronization
detection interrupt enable
5
1
CNRDYIE
Codec not ready interrupt
enable
4
1
FREQIE
FIFO request interrupt
enable
3
1
WCKCFG
Wrong clock configuration interrupt
enable
2
1
MUTEDET
Mute detection interrupt
enable
1
1
OVRUDRIE
Overrun/underrun interrupt
enable
0
1
ASR
ASR
AStatus register
0x18
0x20
read-write
0x00000000
FLVL
FIFO level threshold
16
3
LFSDET
Late frame synchronization
detection
6
1
AFSDET
Anticipated frame synchronization
detection
5
1
CNRDY
Codec not ready
4
1
FREQ
FIFO request
3
1
WCKCFG
Wrong clock configuration flag. This bit
is read only
2
1
MUTEDET
Mute detection
1
1
OVRUDR
Overrun / underrun
0
1
ACLRFR
ACLRFR
AClear flag register
0x1C
0x20
read-write
0x00000000
LFSDET
Clear late frame synchronization
detection flag
6
1
CAFSDET
Clear anticipated frame synchronization
detection flag
5
1
CNRDY
Clear codec not ready flag
4
1
WCKCFG
Clear wrong clock configuration
flag
2
1
MUTEDET
Mute detection flag
1
1
OVRUDR
Clear overrun / underrun
0
1
ADR
ADR
AData register
0x20
0x20
read-write
0x00000000
DATA
Data
0
32
SAI2
0x40015800
SAI2
SAI2 global interrupt
75
TIM2
General-purpose-timers
TIM
0x40000000
0x0
0x400
registers
TIM2
TIM2 global interrupt
28
CR1
CR1
control register 1
0x0
0x20
read-write
0x0000
CKD
Clock division
8
2
ARPE
Auto-reload preload enable
7
1
CMS
Center-aligned mode
selection
5
2
DIR
Direction
4
1
OPM
One-pulse mode
3
1
URS
Update request source
2
1
UDIS
Update disable
1
1
CEN
Counter enable
0
1
CR2
CR2
control register 2
0x4
0x20
read-write
0x0000
TI1S
TI1 selection
7
1
MMS
Master mode selection
4
3
CCDS
Capture/compare DMA
selection
3
1
SMCR
SMCR
slave mode control register
0x8
0x20
read-write
0x0000
ETP
External trigger polarity
15
1
ECE
External clock enable
14
1
ETPS
External trigger prescaler
12
2
ETF
External trigger filter
8
4
MSM
Master/Slave mode
7
1
TS
Trigger selection
4
3
SMS
Slave mode selection
0
3
DIER
DIER
DMA/Interrupt enable register
0xC
0x20
read-write
0x0000
TDE
Trigger DMA request enable
14
1
COMDE
COM DMA request enable
13
1
CC4DE
Capture/Compare 4 DMA request
enable
12
1
CC3DE
Capture/Compare 3 DMA request
enable
11
1
CC2DE
Capture/Compare 2 DMA request
enable
10
1
CC1DE
Capture/Compare 1 DMA request
enable
9
1
UDE
Update DMA request enable
8
1
TIE
Trigger interrupt enable
6
1
CC4IE
Capture/Compare 4 interrupt
enable
4
1
CC3IE
Capture/Compare 3 interrupt
enable
3
1
CC2IE
Capture/Compare 2 interrupt
enable
2
1
CC1IE
Capture/Compare 1 interrupt
enable
1
1
UIE
Update interrupt enable
0
1
SR
SR
status register
0x10
0x20
read-write
0x0000
CC4OF
Capture/Compare 4 overcapture
flag
12
1
CC3OF
Capture/Compare 3 overcapture
flag
11
1
CC2OF
Capture/compare 2 overcapture
flag
10
1
CC1OF
Capture/Compare 1 overcapture
flag
9
1
TIF
Trigger interrupt flag
6
1
CC4IF
Capture/Compare 4 interrupt
flag
4
1
CC3IF
Capture/Compare 3 interrupt
flag
3
1
CC2IF
Capture/Compare 2 interrupt
flag
2
1
CC1IF
Capture/compare 1 interrupt
flag
1
1
UIF
Update interrupt flag
0
1
EGR
EGR
event generation register
0x14
0x20
write-only
0x0000
TG
Trigger generation
6
1
CC4G
Capture/compare 4
generation
4
1
CC3G
Capture/compare 3
generation
3
1
CC2G
Capture/compare 2
generation
2
1
CC1G
Capture/compare 1
generation
1
1
UG
Update generation
0
1
CCMR1_Output
CCMR1_Output
capture/compare mode register 1 (output
mode)
0x18
0x20
read-write
0x00000000
OC2CE
Output compare 2 clear
enable
15
1
OC2M
Output compare 2 mode
12
3
OC2PE
Output compare 2 preload
enable
11
1
OC2FE
Output compare 2 fast
enable
10
1
CC2S
Capture/Compare 2
selection
8
2
OC1CE
Output compare 1 clear
enable
7
1
OC1M
Output compare 1 mode
4
3
OC1PE
Output compare 1 preload
enable
3
1
OC1FE
Output compare 1 fast
enable
2
1
CC1S
Capture/Compare 1
selection
0
2
CCMR1_Input
CCMR1_Input
capture/compare mode register 1 (input
mode)
CCMR1_Output
0x18
0x20
read-write
0x00000000
IC2F
Input capture 2 filter
12
4
IC2PSC
Input capture 2 prescaler
10
2
CC2S
Capture/compare 2
selection
8
2
IC1F
Input capture 1 filter
4
4
IC1PSC
Input capture 1 prescaler
2
2
CC1S
Capture/Compare 1
selection
0
2
CCMR2_Output
CCMR2_Output
capture/compare mode register 2 (output
mode)
0x1C
0x20
read-write
0x00000000
OC4CE
Output compare 4 clear
enable
15
1
OC4M
Output compare 4 mode
12
3
OC4PE
Output compare 4 preload
enable
11
1
OC4FE
Output compare 4 fast
enable
10
1
CC4S
Capture/Compare 4
selection
8
2
OC3CE
Output compare 3 clear
enable
7
1
OC3M
Output compare 3 mode
4
3
OC3PE
Output compare 3 preload
enable
3
1
OC3FE
Output compare 3 fast
enable
2
1
CC3S
Capture/Compare 3
selection
0
2
CCMR2_Input
CCMR2_Input
capture/compare mode register 2 (input
mode)
CCMR2_Output
0x1C
0x20
read-write
0x00000000
IC4F
Input capture 4 filter
12
4
IC4PSC
Input capture 4 prescaler
10
2
CC4S
Capture/Compare 4
selection
8
2
IC3F
Input capture 3 filter
4
4
IC3PSC
Input capture 3 prescaler
2
2
CC3S
Capture/Compare 3
selection
0
2
CCER
CCER
capture/compare enable
register
0x20
0x20
read-write
0x0000
CC4NP
Capture/Compare 4 output
Polarity
15
1
CC4P
Capture/Compare 3 output
Polarity
13
1
CC4E
Capture/Compare 4 output
enable
12
1
CC3NP
Capture/Compare 3 output
Polarity
11
1
CC3P
Capture/Compare 3 output
Polarity
9
1
CC3E
Capture/Compare 3 output
enable
8
1
CC2NP
Capture/Compare 2 output
Polarity
7
1
CC2P
Capture/Compare 2 output
Polarity
5
1
CC2E
Capture/Compare 2 output
enable
4
1
CC1NP
Capture/Compare 1 output
Polarity
3
1
CC1P
Capture/Compare 1 output
Polarity
1
1
CC1E
Capture/Compare 1 output
enable
0
1
CNT
CNT
counter
0x24
0x20
read-write
0x00000000
CNT_H
High counter value (TIM2
only)
16
16
CNT_L
Low counter value
0
16
PSC
PSC
prescaler
0x28
0x20
read-write
0x0000
PSC
Prescaler value
0
16
ARR
ARR
auto-reload register
0x2C
0x20
read-write
0x00000000
ARR_H
High Auto-reload value (TIM2
only)
16
16
ARR_L
Low Auto-reload value
0
16
CCR1
CCR1
capture/compare register 1
0x34
0x20
read-write
0x00000000
CCR1_H
High Capture/Compare 1 value (TIM2
only)
16
16
CCR1_L
Low Capture/Compare 1
value
0
16
CCR2
CCR2
capture/compare register 2
0x38
0x20
read-write
0x00000000
CCR2_H
High Capture/Compare 2 value (TIM2
only)
16
16
CCR2_L
Low Capture/Compare 2
value
0
16
CCR3
CCR3
capture/compare register 3
0x3C
0x20
read-write
0x00000000
CCR3_H
High Capture/Compare value (TIM2
only)
16
16
CCR3_L
Low Capture/Compare value
0
16
CCR4
CCR4
capture/compare register 4
0x40
0x20
read-write
0x00000000
CCR4_H
High Capture/Compare value (TIM2
only)
16
16
CCR4_L
Low Capture/Compare value
0
16
DCR
DCR
DMA control register
0x48
0x20
read-write
0x0000
DBL
DMA burst length
8
5
DBA
DMA base address
0
5
DMAR
DMAR
DMA address for full transfer
0x4C
0x20
read-write
0x0000
DMAB
DMA register for burst
accesses
0
16
OR
OR
TIM2 option register
0x50
0x20
read-write
0x0000
ETR_RMP
Timer2 ETR remap
0
3
TI4_RMP
Internal trigger
3
2
TIM3
0x40000400
TIM3
TIM3 global interrupt
29
TIM4
0x40000800
TIM4
TIM4 global interrupt
30
TIM5
0x40000C00
TIM5
TIM5 global Interrupt
50
TIM15
General purpose timers
TIM
0x40014000
0x0
0x400
registers
CR1
CR1
control register 1
0x0
0x20
read-write
0x0000
CEN
Counter enable
0
1
UDIS
Update disable
1
1
URS
Update request source
2
1
OPM
One-pulse mode
3
1
ARPE
Auto-reload preload enable
7
1
CKD
Clock division
8
2
UIFREMAP
UIF status bit remapping
11
1
CR2
CR2
control register 2
0x4
0x20
read-write
0x0000
OIS1N
Output Idle state 1
9
1
OIS1
Output Idle state 1
8
1
CCDS
Capture/compare DMA
selection
3
1
CCUS
Capture/compare control update
selection
2
1
CCPC
Capture/compare preloaded
control
0
1
DIER
DIER
DMA/Interrupt enable register
0xC
0x20
read-write
0x0000
TDE
Trigger DMA request enable
14
1
COMDE
COM DMA request enable
13
1
CC1DE
Capture/Compare 1 DMA request
enable
9
1
UDE
Update DMA request enable
8
1
BIE
Break interrupt enable
7
1
TIE
Trigger interrupt enable
6
1
COMIE
COM interrupt enable
5
1
CC1IE
Capture/Compare 1 interrupt
enable
1
1
UIE
Update interrupt enable
0
1
SR
SR
status register
0x10
0x20
read-write
0x0000
CC1OF
Capture/Compare 1 overcapture
flag
9
1
BIF
Break interrupt flag
7
1
TIF
Trigger interrupt flag
6
1
COMIF
COM interrupt flag
5
1
CC1IF
Capture/compare 1 interrupt
flag
1
1
UIF
Update interrupt flag
0
1
EGR
EGR
event generation register
0x14
0x20
write-only
0x0000
BG
Break generation
7
1
TG
Trigger generation
6
1
COMG
Capture/Compare control update
generation
5
1
CC1G
Capture/compare 1
generation
1
1
UG
Update generation
0
1
CCMR1_Output
CCMR1_Output
capture/compare mode register (output
mode)
0x18
0x20
read-write
0x00000000
OC1M_2
Output Compare 1 mode
16
1
OC1M
Output Compare 1 mode
4
3
OC1PE
Output Compare 1 preload
enable
3
1
OC1FE
Output Compare 1 fast
enable
2
1
CC1S
Capture/Compare 1
selection
0
2
CCMR1_Input
CCMR1_Input
capture/compare mode register 1 (input
mode)
CCMR1_Output
0x18
0x20
read-write
0x00000000
IC1F
Input capture 1 filter
4
4
IC1PSC
Input capture 1 prescaler
2
2
CC1S
Capture/Compare 1
selection
0
2
CCER
CCER
capture/compare enable
register
0x20
0x20
read-write
0x0000
CC1NP
Capture/Compare 1 output
Polarity
3
1
CC1NE
Capture/Compare 1 complementary output
enable
2
1
CC1P
Capture/Compare 1 output
Polarity
1
1
CC1E
Capture/Compare 1 output
enable
0
1
CNT
CNT
counter
0x24
0x20
0x00000000
CNT
counter value
0
16
read-write
UIFCPY
UIF Copy
31
1
read-only
PSC
PSC
prescaler
0x28
0x20
read-write
0x0000
PSC
Prescaler value
0
16
ARR
ARR
auto-reload register
0x2C
0x20
read-write
0x00000000
ARR
Auto-reload value
0
16
RCR
RCR
repetition counter register
0x30
0x20
read-write
0x0000
REP
Repetition counter value
0
8
CCR1
CCR1
capture/compare register 1
0x34
0x20
read-write
0x00000000
CCR1
Capture/Compare 1 value
0
16
BDTR
BDTR
break and dead-time register
0x44
0x20
read-write
0x0000
DTG
Dead-time generator setup
0
8
LOCK
Lock configuration
8
2
OSSI
Off-state selection for Idle
mode
10
1
OSSR
Off-state selection for Run
mode
11
1
BKE
Break enable
12
1
BKP
Break polarity
13
1
AOE
Automatic output enable
14
1
MOE
Main output enable
15
1
BKF
Break filter
16
4
DCR
DCR
DMA control register
0x48
0x20
read-write
0x0000
DBL
DMA burst length
8
5
DBA
DMA base address
0
5
DMAR
DMAR
DMA address for full transfer
0x4C
0x20
read-write
0x0000
DMAB
DMA register for burst
accesses
0
16
TIM16
General purpose timers
TIM
0x40014400
0x0
0x400
registers
CR1
CR1
control register 1
0x0
0x20
read-write
0x0000
CEN
Counter enable
0
1
UDIS
Update disable
1
1
URS
Update request source
2
1
OPM
One-pulse mode
3
1
ARPE
Auto-reload preload enable
7
1
CKD
Clock division
8
2
UIFREMAP
UIF status bit remapping
11
1
CR2
CR2
control register 2
0x4
0x20
read-write
0x0000
OIS1N
Output Idle state 1
9
1
OIS1
Output Idle state 1
8
1
CCDS
Capture/compare DMA
selection
3
1
CCUS
Capture/compare control update
selection
2
1
CCPC
Capture/compare preloaded
control
0
1
DIER
DIER
DMA/Interrupt enable register
0xC
0x20
read-write
0x0000
TDE
Trigger DMA request enable
14
1
COMDE
COM DMA request enable
13
1
CC1DE
Capture/Compare 1 DMA request
enable
9
1
UDE
Update DMA request enable
8
1
BIE
Break interrupt enable
7
1
TIE
Trigger interrupt enable
6
1
COMIE
COM interrupt enable
5
1
CC1IE
Capture/Compare 1 interrupt
enable
1
1
UIE
Update interrupt enable
0
1
SR
SR
status register
0x10
0x20
read-write
0x0000
CC1OF
Capture/Compare 1 overcapture
flag
9
1
BIF
Break interrupt flag
7
1
TIF
Trigger interrupt flag
6
1
COMIF
COM interrupt flag
5
1
CC1IF
Capture/compare 1 interrupt
flag
1
1
UIF
Update interrupt flag
0
1
EGR
EGR
event generation register
0x14
0x20
write-only
0x0000
BG
Break generation
7
1
TG
Trigger generation
6
1
COMG
Capture/Compare control update
generation
5
1
CC1G
Capture/compare 1
generation
1
1
UG
Update generation
0
1
CCMR1_Output
CCMR1_Output
capture/compare mode register (output
mode)
0x18
0x20
read-write
0x00000000
OC1M_2
Output Compare 1 mode
16
1
OC1M
Output Compare 1 mode
4
3
OC1PE
Output Compare 1 preload
enable
3
1
OC1FE
Output Compare 1 fast
enable
2
1
CC1S
Capture/Compare 1
selection
0
2
CCMR1_Input
CCMR1_Input
capture/compare mode register 1 (input
mode)
CCMR1_Output
0x18
0x20
read-write
0x00000000
IC1F
Input capture 1 filter
4
4
IC1PSC
Input capture 1 prescaler
2
2
CC1S
Capture/Compare 1
selection
0
2
CCER
CCER
capture/compare enable
register
0x20
0x20
read-write
0x0000
CC1NP
Capture/Compare 1 output
Polarity
3
1
CC1NE
Capture/Compare 1 complementary output
enable
2
1
CC1P
Capture/Compare 1 output
Polarity
1
1
CC1E
Capture/Compare 1 output
enable
0
1
CNT
CNT
counter
0x24
0x20
0x00000000
CNT
counter value
0
16
read-write
UIFCPY
UIF Copy
31
1
read-only
PSC
PSC
prescaler
0x28
0x20
read-write
0x0000
PSC
Prescaler value
0
16
ARR
ARR
auto-reload register
0x2C
0x20
read-write
0x00000000
ARR
Auto-reload value
0
16
RCR
RCR
repetition counter register
0x30
0x20
read-write
0x0000
REP
Repetition counter value
0
8
CCR1
CCR1
capture/compare register 1
0x34
0x20
read-write
0x00000000
CCR1
Capture/Compare 1 value
0
16
BDTR
BDTR
break and dead-time register
0x44
0x20
read-write
0x0000
DTG
Dead-time generator setup
0
8
LOCK
Lock configuration
8
2
OSSI
Off-state selection for Idle
mode
10
1
OSSR
Off-state selection for Run
mode
11
1
BKE
Break enable
12
1
BKP
Break polarity
13
1
AOE
Automatic output enable
14
1
MOE
Main output enable
15
1
BKF
Break filter
16
4
DCR
DCR
DMA control register
0x48
0x20
read-write
0x0000
DBL
DMA burst length
8
5
DBA
DMA base address
0
5
DMAR
DMAR
DMA address for full transfer
0x4C
0x20
read-write
0x0000
DMAB
DMA register for burst
accesses
0
16
OR1
OR1
TIM16 option register 1
0x50
0x20
read-write
0x0000
TI1_RMP
Input capture 1 remap
0
2
OR2
OR2
TIM17 option register 1
0x60
0x20
read-write
0x0000
BKINE
BRK BKIN input enable
0
1
BKCMP1E
BRK COMP1 enable
1
1
BKCMP2E
BRK COMP2 enable
2
1
BKDFBK1E
BRK DFSDM_BREAK1 enable
8
1
BKINP
BRK BKIN input polarity
9
1
BKCMP1P
BRK COMP1 input polarity
10
1
BKCMP2P
BRK COMP2 input polarit
11
1
TIM17
0x40014800
TIM1
Advanced-timers
TIM
0x40012C00
0x0
0x400
registers
TIM1_BRK_TIM15
TIM1 Break/TIM15 global
interrupts
24
TIM1_UP_TIM16
TIM1 Update/TIM16 global
interrupts
25
TIM1_TRG_COM_TIM17
TIM1 Trigger and Commutation interrupts and
TIM17 global interrupt
26
TIM1_CC
TIM1 Capture Compare interrupt
27
CR1
CR1
control register 1
0x0
0x20
read-write
0x0000
CKD
Clock division
8
2
ARPE
Auto-reload preload enable
7
1
CMS
Center-aligned mode
selection
5
2
DIR
Direction
4
1
OPM
One-pulse mode
3
1
URS
Update request source
2
1
UDIS
Update disable
1
1
CEN
Counter enable
0
1
CR2
CR2
control register 2
0x4
0x20
read-write
0x0000
OIS4
Output Idle state 4
14
1
OIS3N
Output Idle state 3
13
1
OIS3
Output Idle state 3
12
1
OIS2N
Output Idle state 2
11
1
OIS2
Output Idle state 2
10
1
OIS1N
Output Idle state 1
9
1
OIS1
Output Idle state 1
8
1
TI1S
TI1 selection
7
1
MMS
Master mode selection
4
3
CCDS
Capture/compare DMA
selection
3
1
CCUS
Capture/compare control update
selection
2
1
CCPC
Capture/compare preloaded
control
0
1
SMCR
SMCR
slave mode control register
0x8
0x20
read-write
0x0000
ETP
External trigger polarity
15
1
ECE
External clock enable
14
1
ETPS
External trigger prescaler
12
2
ETF
External trigger filter
8
4
MSM
Master/Slave mode
7
1
TS
Trigger selection
4
3
SMS
Slave mode selection
0
3
DIER
DIER
DMA/Interrupt enable register
0xC
0x20
read-write
0x0000
TDE
Trigger DMA request enable
14
1
COMDE
COM DMA request enable
13
1
CC4DE
Capture/Compare 4 DMA request
enable
12
1
CC3DE
Capture/Compare 3 DMA request
enable
11
1
CC2DE
Capture/Compare 2 DMA request
enable
10
1
CC1DE
Capture/Compare 1 DMA request
enable
9
1
UDE
Update DMA request enable
8
1
TIE
Trigger interrupt enable
6
1
CC4IE
Capture/Compare 4 interrupt
enable
4
1
CC3IE
Capture/Compare 3 interrupt
enable
3
1
CC2IE
Capture/Compare 2 interrupt
enable
2
1
CC1IE
Capture/Compare 1 interrupt
enable
1
1
UIE
Update interrupt enable
0
1
BIE
Break interrupt enable
7
1
COMIE
COM interrupt enable
5
1
SR
SR
status register
0x10
0x20
read-write
0x0000
CC4OF
Capture/Compare 4 overcapture
flag
12
1
CC3OF
Capture/Compare 3 overcapture
flag
11
1
CC2OF
Capture/compare 2 overcapture
flag
10
1
CC1OF
Capture/Compare 1 overcapture
flag
9
1
BIF
Break interrupt flag
7
1
TIF
Trigger interrupt flag
6
1
COMIF
COM interrupt flag
5
1
CC4IF
Capture/Compare 4 interrupt
flag
4
1
CC3IF
Capture/Compare 3 interrupt
flag
3
1
CC2IF
Capture/Compare 2 interrupt
flag
2
1
CC1IF
Capture/compare 1 interrupt
flag
1
1
UIF
Update interrupt flag
0
1
EGR
EGR
event generation register
0x14
0x20
write-only
0x0000
BG
Break generation
7
1
TG
Trigger generation
6
1
COMG
Capture/Compare control update
generation
5
1
CC4G
Capture/compare 4
generation
4
1
CC3G
Capture/compare 3
generation
3
1
CC2G
Capture/compare 2
generation
2
1
CC1G
Capture/compare 1
generation
1
1
UG
Update generation
0
1
CCMR1_Output
CCMR1_Output
capture/compare mode register 1 (output
mode)
0x18
0x20
read-write
0x00000000
OC2CE
Output Compare 2 clear
enable
15
1
OC2M
Output Compare 2 mode
12
3
OC2PE
Output Compare 2 preload
enable
11
1
OC2FE
Output Compare 2 fast
enable
10
1
CC2S
Capture/Compare 2
selection
8
2
OC1CE
Output Compare 1 clear
enable
7
1
OC1M
Output Compare 1 mode
4
3
OC1PE
Output Compare 1 preload
enable
3
1
OC1FE
Output Compare 1 fast
enable
2
1
CC1S
Capture/Compare 1
selection
0
2
CCMR1_Input
CCMR1_Input
capture/compare mode register 1 (input
mode)
CCMR1_Output
0x18
0x20
read-write
0x00000000
IC2F
Input capture 2 filter
12
4
IC2PCS
Input capture 2 prescaler
10
2
CC2S
Capture/Compare 2
selection
8
2
IC1F
Input capture 1 filter
4
4
ICPCS
Input capture 1 prescaler
2
2
CC1S
Capture/Compare 1
selection
0
2
CCMR2_Output
CCMR2_Output
capture/compare mode register 2 (output
mode)
0x1C
0x20
read-write
0x00000000
OC4CE
Output compare 4 clear
enable
15
1
OC4M
Output compare 4 mode
12
3
OC4PE
Output compare 4 preload
enable
11
1
OC4FE
Output compare 4 fast
enable
10
1
CC4S
Capture/Compare 4
selection
8
2
OC3CE
Output compare 3 clear
enable
7
1
OC3M
Output compare 3 mode
4
3
OC3PE
Output compare 3 preload
enable
3
1
OC3FE
Output compare 3 fast
enable
2
1
CC3S
Capture/Compare 3
selection
0
2
CCMR2_Input
CCMR2_Input
capture/compare mode register 2 (input
mode)
CCMR2_Output
0x1C
0x20
read-write
0x00000000
IC4F
Input capture 4 filter
12
4
IC4PSC
Input capture 4 prescaler
10
2
CC4S
Capture/Compare 4
selection
8
2
IC3F
Input capture 3 filter
4
4
IC3PSC
Input capture 3 prescaler
2
2
CC3S
Capture/compare 3
selection
0
2
CCER
CCER
capture/compare enable
register
0x20
0x20
read-write
0x0000
CC4P
Capture/Compare 3 output
Polarity
13
1
CC4E
Capture/Compare 4 output
enable
12
1
CC3NP
Capture/Compare 3 output
Polarity
11
1
CC3NE
Capture/Compare 3 complementary output
enable
10
1
CC3P
Capture/Compare 3 output
Polarity
9
1
CC3E
Capture/Compare 3 output
enable
8
1
CC2NP
Capture/Compare 2 output
Polarity
7
1
CC2NE
Capture/Compare 2 complementary output
enable
6
1
CC2P
Capture/Compare 2 output
Polarity
5
1
CC2E
Capture/Compare 2 output
enable
4
1
CC1NP
Capture/Compare 1 output
Polarity
3
1
CC1NE
Capture/Compare 1 complementary output
enable
2
1
CC1P
Capture/Compare 1 output
Polarity
1
1
CC1E
Capture/Compare 1 output
enable
0
1
CNT
CNT
counter
0x24
0x20
read-write
0x00000000
CNT
counter value
0
16
PSC
PSC
prescaler
0x28
0x20
read-write
0x0000
PSC
Prescaler value
0
16
ARR
ARR
auto-reload register
0x2C
0x20
read-write
0x00000000
ARR
Auto-reload value
0
16
RCR
RCR
repetition counter register
0x30
0x20
read-write
0x0000
REP
Repetition counter value
0
8
CCR1
CCR1
capture/compare register 1
0x34
0x20
read-write
0x00000000
CCR1
Capture/Compare 1 value
0
16
CCR2
CCR2
capture/compare register 2
0x38
0x20
read-write
0x00000000
CCR2
Capture/Compare 2 value
0
16
CCR3
CCR3
capture/compare register 3
0x3C
0x20
read-write
0x00000000
CCR3
Capture/Compare value
0
16
CCR4
CCR4
capture/compare register 4
0x40
0x20
read-write
0x00000000
CCR4
Capture/Compare value
0
16
BDTR
BDTR
break and dead-time register
0x44
0x20
read-write
0x0000
MOE
Main output enable
15
1
AOE
Automatic output enable
14
1
BKP
Break polarity
13
1
BKE
Break enable
12
1
OSSR
Off-state selection for Run
mode
11
1
OSSI
Off-state selection for Idle
mode
10
1
LOCK
Lock configuration
8
2
DTG
Dead-time generator setup
0
8
DCR
DCR
DMA control register
0x48
0x20
read-write
0x0000
DBL
DMA burst length
8
5
DBA
DMA base address
0
5
DMAR
DMAR
DMA address for full transfer
0x4C
0x20
read-write
0x0000
DMAB
DMA register for burst
accesses
0
16
OR1
OR1
DMA address for full transfer
0x50
0x20
read-write
0x0000
ETR_ADC1_RMP
External trigger remap on ADC1 analog
watchdog
0
2
ETR_ADC3_RMP
External trigger remap on ADC3 analog
watchdog
2
2
TI1_RMP
Input Capture 1 remap
4
1
CCMR3_Output
CCMR3_Output
capture/compare mode register 2 (output
mode)
0x54
0x20
read-write
0x00000000
OC6M_bit3
Output Compare 6 mode bit
3
24
1
OC5M_bit3
Output Compare 5 mode bit
3
16
3
OC6CE
Output compare 6 clear
enable
15
1
OC6M
Output compare 6 mode
12
3
OC6PE
Output compare 6 preload
enable
11
1
OC6FE
Output compare 6 fast
enable
10
1
OC5CE
Output compare 5 clear
enable
7
1
OC5M
Output compare 5 mode
4
3
OC5PE
Output compare 5 preload
enable
3
1
OC5FE
Output compare 5 fast
enable
2
1
CCR5
CCR5
capture/compare register 4
0x58
0x20
read-write
0x00000000
CCR5
Capture/Compare value
0
16
GC5C1
Group Channel 5 and Channel
1
29
1
GC5C2
Group Channel 5 and Channel
2
30
1
GC5C3
Group Channel 5 and Channel
3
31
1
CCR6
CCR6
capture/compare register 4
0x5C
0x20
read-write
0x00000000
CCR6
Capture/Compare value
0
16
OR2
OR2
DMA address for full transfer
0x60
0x20
read-write
0x00000001
BKINE
BRK BKIN input enable
0
1
BKCMP1E
BRK COMP1 enable
1
1
BKCMP2E
BRK COMP2 enable
2
1
BKDFBK0E
BRK DFSDM_BREAK0 enable
8
1
BKINP
BRK BKIN input polarity
9
1
BKCMP1P
BRK COMP1 input polarity
10
1
BKCMP2P
BRK COMP2 input polarity
11
1
ETRSEL
ETR source selection
14
3
OR3
OR3
DMA address for full transfer
0x64
0x20
read-write
0x00000001
BK2INE
BRK2 BKIN input enable
0
1
BK2CMP1E
BRK2 COMP1 enable
1
1
BK2CMP2E
BRK2 COMP2 enable
2
1
BK2DFBK0E
BRK2 DFSDM_BREAK0 enable
8
1
BK2INP
BRK2 BKIN input polarity
9
1
BK2CMP1P
BRK2 COMP1 input polarity
10
1
BK2CMP2P
BRK2 COMP2 input polarity
11
1
TIM8
Advanced-timers
TIM
0x40013400
0x0
0x400
registers
TIM8_BRK
TIM8 Break Interrupt
43
TIM8_UP
TIM8 Update Interrupt
44
TIM8_TRG_COM
TIM8 Trigger and Commutation
Interrupt
45
TIM8_CC
TIM8 Capture Compare Interrupt
46
CR1
CR1
control register 1
0x0
0x20
read-write
0x0000
CKD
Clock division
8
2
ARPE
Auto-reload preload enable
7
1
CMS
Center-aligned mode
selection
5
2
DIR
Direction
4
1
OPM
One-pulse mode
3
1
URS
Update request source
2
1
UDIS
Update disable
1
1
CEN
Counter enable
0
1
CR2
CR2
control register 2
0x4
0x20
read-write
0x0000
OIS4
Output Idle state 4
14
1
OIS3N
Output Idle state 3
13
1
OIS3
Output Idle state 3
12
1
OIS2N
Output Idle state 2
11
1
OIS2
Output Idle state 2
10
1
OIS1N
Output Idle state 1
9
1
OIS1
Output Idle state 1
8
1
TI1S
TI1 selection
7
1
MMS
Master mode selection
4
3
CCDS
Capture/compare DMA
selection
3
1
CCUS
Capture/compare control update
selection
2
1
CCPC
Capture/compare preloaded
control
0
1
SMCR
SMCR
slave mode control register
0x8
0x20
read-write
0x0000
ETP
External trigger polarity
15
1
ECE
External clock enable
14
1
ETPS
External trigger prescaler
12
2
ETF
External trigger filter
8
4
MSM
Master/Slave mode
7
1
TS
Trigger selection
4
3
SMS
Slave mode selection
0
3
DIER
DIER
DMA/Interrupt enable register
0xC
0x20
read-write
0x0000
TDE
Trigger DMA request enable
14
1
COMDE
COM DMA request enable
13
1
CC4DE
Capture/Compare 4 DMA request
enable
12
1
CC3DE
Capture/Compare 3 DMA request
enable
11
1
CC2DE
Capture/Compare 2 DMA request
enable
10
1
CC1DE
Capture/Compare 1 DMA request
enable
9
1
UDE
Update DMA request enable
8
1
TIE
Trigger interrupt enable
6
1
CC4IE
Capture/Compare 4 interrupt
enable
4
1
CC3IE
Capture/Compare 3 interrupt
enable
3
1
CC2IE
Capture/Compare 2 interrupt
enable
2
1
CC1IE
Capture/Compare 1 interrupt
enable
1
1
UIE
Update interrupt enable
0
1
BIE
Break interrupt enable
7
1
COMIE
COM interrupt enable
5
1
SR
SR
status register
0x10
0x20
read-write
0x0000
CC4OF
Capture/Compare 4 overcapture
flag
12
1
CC3OF
Capture/Compare 3 overcapture
flag
11
1
CC2OF
Capture/compare 2 overcapture
flag
10
1
CC1OF
Capture/Compare 1 overcapture
flag
9
1
BIF
Break interrupt flag
7
1
TIF
Trigger interrupt flag
6
1
COMIF
COM interrupt flag
5
1
CC4IF
Capture/Compare 4 interrupt
flag
4
1
CC3IF
Capture/Compare 3 interrupt
flag
3
1
CC2IF
Capture/Compare 2 interrupt
flag
2
1
CC1IF
Capture/compare 1 interrupt
flag
1
1
UIF
Update interrupt flag
0
1
EGR
EGR
event generation register
0x14
0x20
write-only
0x0000
BG
Break generation
7
1
TG
Trigger generation
6
1
COMG
Capture/Compare control update
generation
5
1
CC4G
Capture/compare 4
generation
4
1
CC3G
Capture/compare 3
generation
3
1
CC2G
Capture/compare 2
generation
2
1
CC1G
Capture/compare 1
generation
1
1
UG
Update generation
0
1
CCMR1_Output
CCMR1_Output
capture/compare mode register 1 (output
mode)
0x18
0x20
read-write
0x00000000
OC2CE
Output Compare 2 clear
enable
15
1
OC2M
Output Compare 2 mode
12
3
OC2PE
Output Compare 2 preload
enable
11
1
OC2FE
Output Compare 2 fast
enable
10
1
CC2S
Capture/Compare 2
selection
8
2
OC1CE
Output Compare 1 clear
enable
7
1
OC1M
Output Compare 1 mode
4
3
OC1PE
Output Compare 1 preload
enable
3
1
OC1FE
Output Compare 1 fast
enable
2
1
CC1S
Capture/Compare 1
selection
0
2
CCMR1_Input
CCMR1_Input
capture/compare mode register 1 (input
mode)
CCMR1_Output
0x18
0x20
read-write
0x00000000
IC2F
Input capture 2 filter
12
4
IC2PCS
Input capture 2 prescaler
10
2
CC2S
Capture/Compare 2
selection
8
2
IC1F
Input capture 1 filter
4
4
ICPCS
Input capture 1 prescaler
2
2
CC1S
Capture/Compare 1
selection
0
2
CCMR2_Output
CCMR2_Output
capture/compare mode register 2 (output
mode)
0x1C
0x20
read-write
0x00000000
OC4CE
Output compare 4 clear
enable
15
1
OC4M
Output compare 4 mode
12
3
OC4PE
Output compare 4 preload
enable
11
1
OC4FE
Output compare 4 fast
enable
10
1
CC4S
Capture/Compare 4
selection
8
2
OC3CE
Output compare 3 clear
enable
7
1
OC3M
Output compare 3 mode
4
3
OC3PE
Output compare 3 preload
enable
3
1
OC3FE
Output compare 3 fast
enable
2
1
CC3S
Capture/Compare 3
selection
0
2
CCMR2_Input
CCMR2_Input
capture/compare mode register 2 (input
mode)
CCMR2_Output
0x1C
0x20
read-write
0x00000000
IC4F
Input capture 4 filter
12
4
IC4PSC
Input capture 4 prescaler
10
2
CC4S
Capture/Compare 4
selection
8
2
IC3F
Input capture 3 filter
4
4
IC3PSC
Input capture 3 prescaler
2
2
CC3S
Capture/compare 3
selection
0
2
CCER
CCER
capture/compare enable
register
0x20
0x20
read-write
0x0000
CC4P
Capture/Compare 3 output
Polarity
13
1
CC4E
Capture/Compare 4 output
enable
12
1
CC3NP
Capture/Compare 3 output
Polarity
11
1
CC3NE
Capture/Compare 3 complementary output
enable
10
1
CC3P
Capture/Compare 3 output
Polarity
9
1
CC3E
Capture/Compare 3 output
enable
8
1
CC2NP
Capture/Compare 2 output
Polarity
7
1
CC2NE
Capture/Compare 2 complementary output
enable
6
1
CC2P
Capture/Compare 2 output
Polarity
5
1
CC2E
Capture/Compare 2 output
enable
4
1
CC1NP
Capture/Compare 1 output
Polarity
3
1
CC1NE
Capture/Compare 1 complementary output
enable
2
1
CC1P
Capture/Compare 1 output
Polarity
1
1
CC1E
Capture/Compare 1 output
enable
0
1
CNT
CNT
counter
0x24
0x20
read-write
0x00000000
CNT
counter value
0
16
PSC
PSC
prescaler
0x28
0x20
read-write
0x0000
PSC
Prescaler value
0
16
ARR
ARR
auto-reload register
0x2C
0x20
read-write
0x00000000
ARR
Auto-reload value
0
16
RCR
RCR
repetition counter register
0x30
0x20
read-write
0x0000
REP
Repetition counter value
0
8
CCR1
CCR1
capture/compare register 1
0x34
0x20
read-write
0x00000000
CCR1
Capture/Compare 1 value
0
16
CCR2
CCR2
capture/compare register 2
0x38
0x20
read-write
0x00000000
CCR2
Capture/Compare 2 value
0
16
CCR3
CCR3
capture/compare register 3
0x3C
0x20
read-write
0x00000000
CCR3
Capture/Compare value
0
16
CCR4
CCR4
capture/compare register 4
0x40
0x20
read-write
0x00000000
CCR4
Capture/Compare value
0
16
BDTR
BDTR
break and dead-time register
0x44
0x20
read-write
0x0000
MOE
Main output enable
15
1
AOE
Automatic output enable
14
1
BKP
Break polarity
13
1
BKE
Break enable
12
1
OSSR
Off-state selection for Run
mode
11
1
OSSI
Off-state selection for Idle
mode
10
1
LOCK
Lock configuration
8
2
DTG
Dead-time generator setup
0
8
DCR
DCR
DMA control register
0x48
0x20
read-write
0x0000
DBL
DMA burst length
8
5
DBA
DMA base address
0
5
DMAR
DMAR
DMA address for full transfer
0x4C
0x20
read-write
0x0000
DMAB
DMA register for burst
accesses
0
16
OR1
OR1
DMA address for full transfer
0x50
0x20
read-write
0x0000
ETR_ADC2_RMP
External trigger remap on ADC2 analog
watchdog
0
2
ETR_ADC3_RMP
External trigger remap on ADC3 analog
watchdog
2
2
TI1_RMP
Input Capture 1 remap
4
1
CCMR3_Output
CCMR3_Output
capture/compare mode register 2 (output
mode)
0x54
0x20
read-write
0x00000000
OC6M_bit3
Output Compare 6 mode bit
3
24
1
OC5M_bit3
Output Compare 5 mode bit
3
16
3
OC6CE
Output compare 6 clear
enable
15
1
OC6M
Output compare 6 mode
12
3
OC6PE
Output compare 6 preload
enable
11
1
OC6FE
Output compare 6 fast
enable
10
1
OC5CE
Output compare 5 clear
enable
7
1
OC5M
Output compare 5 mode
4
3
OC5PE
Output compare 5 preload
enable
3
1
OC5FE
Output compare 5 fast
enable
2
1
CCR5
CCR5
capture/compare register 4
0x58
0x20
read-write
0x00000000
CCR5
Capture/Compare value
0
16
GC5C1
Group Channel 5 and Channel
1
29
1
GC5C2
Group Channel 5 and Channel
2
30
1
GC5C3
Group Channel 5 and Channel
3
31
1
CCR6
CCR6
capture/compare register 4
0x5C
0x20
read-write
0x00000000
CCR6
Capture/Compare value
0
16
OR2
OR2
DMA address for full transfer
0x60
0x20
read-write
0x00000001
BKINE
BRK BKIN input enable
0
1
BKCMP1E
BRK COMP1 enable
1
1
BKCMP2E
BRK COMP2 enable
2
1
BKDFBK2E
BRK DFSDM_BREAK2 enable
8
1
BKINP
BRK BKIN input polarity
9
1
BKCMP1P
BRK COMP1 input polarity
10
1
BKCMP2P
BRK COMP2 input polarity
11
1
ETRSEL
ETR source selection
14
3
OR3
OR3
DMA address for full transfer
0x64
0x20
read-write
0x00000001
BK2INE
BRK2 BKIN input enable
0
1
BK2CMP1E
BRK2 COMP1 enable
1
1
BK2CMP2E
BRK2 COMP2 enable
2
1
BK2DFBK3E
BRK2 DFSDM_BREAK3 enable
8
1
BK2INP
BRK2 BKIN input polarity
9
1
BK2CMP1P
BRK2 COMP1 input polarity
10
1
BK2CMP2P
BRK2 COMP2 input polarity
11
1
TIM6
Basic-timers
TIM
0x40001000
0x0
0x400
registers
TIM6_DACUNDER
TIM6 global and DAC1 and 2 underrun error
interrupts
54
CR1
CR1
control register 1
0x0
0x20
read-write
0x0000
ARPE
Auto-reload preload enable
7
1
OPM
One-pulse mode
3
1
URS
Update request source
2
1
UDIS
Update disable
1
1
CEN
Counter enable
0
1
CR2
CR2
control register 2
0x4
0x20
read-write
0x0000
MMS
Master mode selection
4
3
DIER
DIER
DMA/Interrupt enable register
0xC
0x20
read-write
0x0000
UDE
Update DMA request enable
8
1
UIE
Update interrupt enable
0
1
SR
SR
status register
0x10
0x20
read-write
0x0000
UIF
Update interrupt flag
0
1
EGR
EGR
event generation register
0x14
0x20
write-only
0x0000
UG
Update generation
0
1
CNT
CNT
counter
0x24
0x20
read-write
0x00000000
CNT
Low counter value
0
16
PSC
PSC
prescaler
0x28
0x20
read-write
0x0000
PSC
Prescaler value
0
16
ARR
ARR
auto-reload register
0x2C
0x20
read-write
0x00000000
ARR
Low Auto-reload value
0
16
TIM7
0x40001400
TIM7
TIM7 global interrupt
55
LPTIM1
Low power timer
LPTIM
0x40007C00
0x0
0x400
registers
LPTIM1
LP TIM1 interrupt
65
ISR
ISR
Interrupt and Status Register
0x0
0x20
read-only
0x00000000
DOWN
Counter direction change up to
down
6
1
UP
Counter direction change down to
up
5
1
ARROK
Autoreload register update
OK
4
1
CMPOK
Compare register update OK
3
1
EXTTRIG
External trigger edge
event
2
1
ARRM
Autoreload match
1
1
CMPM
Compare match
0
1
ICR
ICR
Interrupt Clear Register
0x4
0x20
write-only
0x00000000
DOWNCF
Direction change to down Clear
Flag
6
1
UPCF
Direction change to UP Clear
Flag
5
1
ARROKCF
Autoreload register update OK Clear
Flag
4
1
CMPOKCF
Compare register update OK Clear
Flag
3
1
EXTTRIGCF
External trigger valid edge Clear
Flag
2
1
ARRMCF
Autoreload match Clear
Flag
1
1
CMPMCF
compare match Clear Flag
0
1
IER
IER
Interrupt Enable Register
0x8
0x20
read-write
0x00000000
DOWNIE
Direction change to down Interrupt
Enable
6
1
UPIE
Direction change to UP Interrupt
Enable
5
1
ARROKIE
Autoreload register update OK Interrupt
Enable
4
1
CMPOKIE
Compare register update OK Interrupt
Enable
3
1
EXTTRIGIE
External trigger valid edge Interrupt
Enable
2
1
ARRMIE
Autoreload match Interrupt
Enable
1
1
CMPMIE
Compare match Interrupt
Enable
0
1
CFGR
CFGR
Configuration Register
0xC
0x20
read-write
0x00000000
ENC
Encoder mode enable
24
1
COUNTMODE
counter mode enabled
23
1
PRELOAD
Registers update mode
22
1
WAVPOL
Waveform shape polarity
21
1
WAVE
Waveform shape
20
1
TIMOUT
Timeout enable
19
1
TRIGEN
Trigger enable and
polarity
17
2
TRIGSEL
Trigger selector
13
3
PRESC
Clock prescaler
9
3
TRGFLT
Configurable digital filter for
trigger
6
2
CKFLT
Configurable digital filter for external
clock
3
2
CKPOL
Clock Polarity
1
2
CKSEL
Clock selector
0
1
CR
CR
Control Register
0x10
0x20
read-write
0x00000000
CNTSTRT
Timer start in continuous
mode
2
1
SNGSTRT
LPTIM start in single mode
1
1
ENABLE
LPTIM Enable
0
1
CMP
CMP
Compare Register
0x14
0x20
read-write
0x00000000
CMP
Compare value
0
16
ARR
ARR
Autoreload Register
0x18
0x20
read-write
0x00000001
ARR
Auto reload value
0
16
CNT
CNT
Counter Register
0x1C
0x20
read-only
0x00000000
CNT
Counter value
0
16
LPTIM2
0x40009400
LPTIM2
LP TIM2 interrupt
66
USART1
Universal synchronous asynchronous receiver
transmitter
USART
0x40013800
0x0
0x400
registers
USART1
USART1 global interrupt
37
CR1
CR1
Control register 1
0x0
0x20
read-write
0x0000
M1
Word length
28
1
EOBIE
End of Block interrupt
enable
27
1
RTOIE
Receiver timeout interrupt
enable
26
1
DEAT4
Driver Enable assertion
time
25
1
DEAT3
DEAT3
24
1
DEAT2
DEAT2
23
1
DEAT1
DEAT1
22
1
DEAT0
DEAT0
21
1
DEDT4
Driver Enable de-assertion
time
20
1
DEDT3
DEDT3
19
1
DEDT2
DEDT2
18
1
DEDT1
DEDT1
17
1
DEDT0
DEDT0
16
1
OVER8
Oversampling mode
15
1
CMIE
Character match interrupt
enable
14
1
MME
Mute mode enable
13
1
M0
Word length
12
1
WAKE
Receiver wakeup method
11
1
PCE
Parity control enable
10
1
PS
Parity selection
9
1
PEIE
PE interrupt enable
8
1
TXEIE
interrupt enable
7
1
TCIE
Transmission complete interrupt
enable
6
1
RXNEIE
RXNE interrupt enable
5
1
IDLEIE
IDLE interrupt enable
4
1
TE
Transmitter enable
3
1
RE
Receiver enable
2
1
UESM
USART enable in Stop mode
1
1
UE
USART enable
0
1
CR2
CR2
Control register 2
0x4
0x20
read-write
0x0000
ADD4_7
Address of the USART node
28
4
ADD0_3
Address of the USART node
24
4
RTOEN
Receiver timeout enable
23
1
ABRMOD1
Auto baud rate mode
22
1
ABRMOD0
ABRMOD0
21
1
ABREN
Auto baud rate enable
20
1
MSBFIRST
Most significant bit first
19
1
TAINV
Binary data inversion
18
1
TXINV
TX pin active level
inversion
17
1
RXINV
RX pin active level
inversion
16
1
SWAP
Swap TX/RX pins
15
1
LINEN
LIN mode enable
14
1
STOP
STOP bits
12
2
CLKEN
Clock enable
11
1
CPOL
Clock polarity
10
1
CPHA
Clock phase
9
1
LBCL
Last bit clock pulse
8
1
LBDIE
LIN break detection interrupt
enable
6
1
LBDL
LIN break detection length
5
1
ADDM7
7-bit Address Detection/4-bit Address
Detection
4
1
CR3
CR3
Control register 3
0x8
0x20
read-write
0x0000
WUFIE
Wakeup from Stop mode interrupt
enable
22
1
WUS
Wakeup from Stop mode interrupt flag
selection
20
2
SCARCNT
Smartcard auto-retry count
17
3
DEP
Driver enable polarity
selection
15
1
DEM
Driver enable mode
14
1
DDRE
DMA Disable on Reception
Error
13
1
OVRDIS
Overrun Disable
12
1
ONEBIT
One sample bit method
enable
11
1
CTSIE
CTS interrupt enable
10
1
CTSE
CTS enable
9
1
RTSE
RTS enable
8
1
DMAT
DMA enable transmitter
7
1
DMAR
DMA enable receiver
6
1
SCEN
Smartcard mode enable
5
1
NACK
Smartcard NACK enable
4
1
HDSEL
Half-duplex selection
3
1
IRLP
Ir low-power
2
1
IREN
Ir mode enable
1
1
EIE
Error interrupt enable
0
1
BRR
BRR
Baud rate register
0xC
0x20
read-write
0x0000
DIV_Mantissa
DIV_Mantissa
4
12
DIV_Fraction
DIV_Fraction
0
4
GTPR
GTPR
Guard time and prescaler
register
0x10
0x20
read-write
0x0000
GT
Guard time value
8
8
PSC
Prescaler value
0
8
RTOR
RTOR
Receiver timeout register
0x14
0x20
read-write
0x0000
BLEN
Block Length
24
8
RTO
Receiver timeout value
0
24
RQR
RQR
Request register
0x18
0x20
write-only
0x0000
TXFRQ
Transmit data flush
request
4
1
RXFRQ
Receive data flush request
3
1
MMRQ
Mute mode request
2
1
SBKRQ
Send break request
1
1
ABRRQ
Auto baud rate request
0
1
ISR
ISR
Interrupt & status
register
0x1C
0x20
read-only
0x00C0
REACK
REACK
22
1
TEACK
TEACK
21
1
WUF
WUF
20
1
RWU
RWU
19
1
SBKF
SBKF
18
1
CMF
CMF
17
1
BUSY
BUSY
16
1
ABRF
ABRF
15
1
ABRE
ABRE
14
1
EOBF
EOBF
12
1
RTOF
RTOF
11
1
CTS
CTS
10
1
CTSIF
CTSIF
9
1
LBDF
LBDF
8
1
TXE
TXE
7
1
TC
TC
6
1
RXNE
RXNE
5
1
IDLE
IDLE
4
1
ORE
ORE
3
1
NF
NF
2
1
FE
FE
1
1
PE
PE
0
1
ICR
ICR
Interrupt flag clear register
0x20
0x20
write-only
0x0000
WUCF
Wakeup from Stop mode clear
flag
20
1
CMCF
Character match clear flag
17
1
EOBCF
End of block clear flag
12
1
RTOCF
Receiver timeout clear
flag
11
1
CTSCF
CTS clear flag
9
1
LBDCF
LIN break detection clear
flag
8
1
TCCF
Transmission complete clear
flag
6
1
IDLECF
Idle line detected clear
flag
4
1
ORECF
Overrun error clear flag
3
1
NCF
Noise detected clear flag
2
1
FECF
Framing error clear flag
1
1
PECF
Parity error clear flag
0
1
RDR
RDR
Receive data register
0x24
0x20
read-only
0x0000
RDR
Receive data value
0
9
TDR
TDR
Transmit data register
0x28
0x20
read-write
0x0000
TDR
Transmit data value
0
9
USART2
0x40004400
USART2
USART2 global interrupt
38
USART3
0x40004800
USART3
USART3 global interrupt
39
UART4
0x40004C00
UART4
UART4 global Interrupt
52
UART5
0x40005000
UART5
UART5 global Interrupt
53
LPUART1
Universal synchronous asynchronous receiver
transmitter
USART
0x40008000
0x0
0x400
registers
LPUART1
LPUART1 global interrupt
70
CR1
CR1
Control register 1
0x0
0x20
read-write
0x0000
M1
Word length
28
1
DEAT4
Driver Enable assertion
time
25
1
DEAT3
DEAT3
24
1
DEAT2
DEAT2
23
1
DEAT1
DEAT1
22
1
DEAT0
DEAT0
21
1
DEDT4
Driver Enable de-assertion
time
20
1
DEDT3
DEDT3
19
1
DEDT2
DEDT2
18
1
DEDT1
DEDT1
17
1
DEDT0
DEDT0
16
1
CMIE
Character match interrupt
enable
14
1
MME
Mute mode enable
13
1
M0
Word length
12
1
WAKE
Receiver wakeup method
11
1
PCE
Parity control enable
10
1
PS
Parity selection
9
1
PEIE
PE interrupt enable
8
1
TXEIE
interrupt enable
7
1
TCIE
Transmission complete interrupt
enable
6
1
RXNEIE
RXNE interrupt enable
5
1
IDLEIE
IDLE interrupt enable
4
1
TE
Transmitter enable
3
1
RE
Receiver enable
2
1
UESM
USART enable in Stop mode
1
1
UE
USART enable
0
1
CR2
CR2
Control register 2
0x4
0x20
read-write
0x0000
ADD4_7
Address of the USART node
28
4
ADD0_3
Address of the USART node
24
4
MSBFIRST
Most significant bit first
19
1
TAINV
Binary data inversion
18
1
TXINV
TX pin active level
inversion
17
1
RXINV
RX pin active level
inversion
16
1
SWAP
Swap TX/RX pins
15
1
STOP
STOP bits
12
2
CLKEN
Clock enable
11
1
ADDM7
7-bit Address Detection/4-bit Address
Detection
4
1
CR3
CR3
Control register 3
0x8
0x20
read-write
0x0000
WUFIE
Wakeup from Stop mode interrupt
enable
22
1
WUS
Wakeup from Stop mode interrupt flag
selection
20
2
DEP
Driver enable polarity
selection
15
1
DEM
Driver enable mode
14
1
DDRE
DMA Disable on Reception
Error
13
1
OVRDIS
Overrun Disable
12
1
CTSIE
CTS interrupt enable
10
1
CTSE
CTS enable
9
1
RTSE
RTS enable
8
1
DMAT
DMA enable transmitter
7
1
DMAR
DMA enable receiver
6
1
HDSEL
Half-duplex selection
3
1
EIE
Error interrupt enable
0
1
BRR
BRR
Baud rate register
0xC
0x20
read-write
0x0000
BRR
BRR
0
20
RQR
RQR
Request register
0x18
0x20
write-only
0x0000
RXFRQ
Receive data flush request
3
1
MMRQ
Mute mode request
2
1
SBKRQ
Send break request
1
1
ISR
ISR
Interrupt & status
register
0x1C
0x20
read-only
0x00C0
REACK
REACK
22
1
TEACK
TEACK
21
1
WUF
WUF
20
1
RWU
RWU
19
1
SBKF
SBKF
18
1
CMF
CMF
17
1
BUSY
BUSY
16
1
CTS
CTS
10
1
CTSIF
CTSIF
9
1
TXE
TXE
7
1
TC
TC
6
1
RXNE
RXNE
5
1
IDLE
IDLE
4
1
ORE
ORE
3
1
NF
NF
2
1
FE
FE
1
1
PE
PE
0
1
ICR
ICR
Interrupt flag clear register
0x20
0x20
write-only
0x0000
WUCF
Wakeup from Stop mode clear
flag
20
1
CMCF
Character match clear flag
17
1
CTSCF
CTS clear flag
9
1
TCCF
Transmission complete clear
flag
6
1
IDLECF
Idle line detected clear
flag
4
1
ORECF
Overrun error clear flag
3
1
NCF
Noise detected clear flag
2
1
FECF
Framing error clear flag
1
1
PECF
Parity error clear flag
0
1
RDR
RDR
Receive data register
0x24
0x20
read-only
0x0000
RDR
Receive data value
0
9
TDR
TDR
Transmit data register
0x28
0x20
read-write
0x0000
TDR
Transmit data value
0
9
SPI1
Serial peripheral interface/Inter-IC
sound
SPI
0x40013000
0x0
0x400
registers
SPI1
SPI1 global interrupt
35
CR1
CR1
control register 1
0x0
0x20
read-write
0x0000
BIDIMODE
Bidirectional data mode
enable
15
1
BIDIOE
Output enable in bidirectional
mode
14
1
CRCEN
Hardware CRC calculation
enable
13
1
CRCNEXT
CRC transfer next
12
1
DFF
Data frame format
11
1
RXONLY
Receive only
10
1
SSM
Software slave management
9
1
SSI
Internal slave select
8
1
LSBFIRST
Frame format
7
1
SPE
SPI enable
6
1
BR
Baud rate control
3
3
MSTR
Master selection
2
1
CPOL
Clock polarity
1
1
CPHA
Clock phase
0
1
CR2
CR2
control register 2
0x4
0x20
read-write
0x0000
RXDMAEN
Rx buffer DMA enable
0
1
TXDMAEN
Tx buffer DMA enable
1
1
SSOE
SS output enable
2
1
NSSP
NSS pulse management
3
1
FRF
Frame format
4
1
ERRIE
Error interrupt enable
5
1
RXNEIE
RX buffer not empty interrupt
enable
6
1
TXEIE
Tx buffer empty interrupt
enable
7
1
DS
Data size
8
4
FRXTH
FIFO reception threshold
12
1
LDMA_RX
Last DMA transfer for
reception
13
1
LDMA_TX
Last DMA transfer for
transmission
14
1
SR
SR
status register
0x8
0x20
0x0002
RXNE
Receive buffer not empty
0
1
read-only
TXE
Transmit buffer empty
1
1
read-only
CRCERR
CRC error flag
4
1
read-write
MODF
Mode fault
5
1
read-only
OVR
Overrun flag
6
1
read-only
BSY
Busy flag
7
1
read-only
TIFRFE
TI frame format error
8
1
read-only
FRLVL
FIFO reception level
9
2
read-only
FTLVL
FIFO transmission level
11
2
read-only
DR
DR
data register
0xC
0x20
read-write
0x0000
DR
Data register
0
16
CRCPR
CRCPR
CRC polynomial register
0x10
0x20
read-write
0x0007
CRCPOLY
CRC polynomial register
0
16
RXCRCR
RXCRCR
RX CRC register
0x14
0x20
read-only
0x0000
RxCRC
Rx CRC register
0
16
TXCRCR
TXCRCR
TX CRC register
0x18
0x20
read-only
0x0000
TxCRC
Tx CRC register
0
16
SPI2
0x40003800
SPI2
SPI2 global interrupt
36
SPI3
0x40003C00
SPI3
SPI3 global Interrupt
51
SDMMC1
Secure digital input/output
interface
SDIO
0x40012800
0x0
0x400
registers
SDMMC1
SDMMC global Interrupt
49
POWER
POWER
power control register
0x0
0x20
read-write
0x00000000
PWRCTRL
PWRCTRL
0
2
CLKCR
CLKCR
SDI clock control register
0x4
0x20
read-write
0x00000000
HWFC_EN
HW Flow Control enable
14
1
NEGEDGE
SDIO_CK dephasing selection
bit
13
1
WIDBUS
Wide bus mode enable bit
11
2
BYPASS
Clock divider bypass enable
bit
10
1
PWRSAV
Power saving configuration
bit
9
1
CLKEN
Clock enable bit
8
1
CLKDIV
Clock divide factor
0
8
ARG
ARG
argument register
0x8
0x20
read-write
0x00000000
CMDARG
Command argument
0
32
CMD
CMD
command register
0xC
0x20
read-write
0x00000000
CE_ATACMD
CE-ATA command
14
1
nIEN
not Interrupt Enable
13
1
ENCMDcompl
Enable CMD completion
12
1
SDIOSuspend
SD I/O suspend command
11
1
CPSMEN
Command path state machine (CPSM) Enable
bit
10
1
WAITPEND
CPSM Waits for ends of data transfer
(CmdPend internal signal)
9
1
WAITINT
CPSM waits for interrupt
request
8
1
WAITRESP
Wait for response bits
6
2
CMDINDEX
Command index
0
6
RESPCMD
RESPCMD
command response register
0x10
0x20
read-only
0x00000000
RESPCMD
Response command index
0
6
RESP1
RESP1
response 1..4 register
0x14
0x20
read-only
0x00000000
CARDSTATUS1
see Table 132
0
32
RESP2
RESP2
response 1..4 register
0x18
0x20
read-only
0x00000000
CARDSTATUS2
see Table 132
0
32
RESP3
RESP3
response 1..4 register
0x1C
0x20
read-only
0x00000000
CARDSTATUS3
see Table 132
0
32
RESP4
RESP4
response 1..4 register
0x20
0x20
read-only
0x00000000
CARDSTATUS4
see Table 132
0
32
DTIMER
DTIMER
data timer register
0x24
0x20
read-write
0x00000000
DATATIME
Data timeout period
0
32
DLEN
DLEN
data length register
0x28
0x20
read-write
0x00000000
DATALENGTH
Data length value
0
25
DCTRL
DCTRL
data control register
0x2C
0x20
read-write
0x00000000
SDIOEN
SD I/O enable functions
11
1
RWMOD
Read wait mode
10
1
RWSTOP
Read wait stop
9
1
RWSTART
Read wait start
8
1
DBLOCKSIZE
Data block size
4
4
DMAEN
DMA enable bit
3
1
DTMODE
Data transfer mode selection 1: Stream
or SDIO multibyte data transfer
2
1
DTDIR
Data transfer direction
selection
1
1
DTEN
DTEN
0
1
DCOUNT
DCOUNT
data counter register
0x30
0x20
read-only
0x00000000
DATACOUNT
Data count value
0
25
STA
STA
status register
0x34
0x20
read-only
0x00000000
CEATAEND
CE-ATA command completion signal
received for CMD61
23
1
SDIOIT
SDIO interrupt received
22
1
RXDAVL
Data available in receive
FIFO
21
1
TXDAVL
Data available in transmit
FIFO
20
1
RXFIFOE
Receive FIFO empty
19
1
TXFIFOE
Transmit FIFO empty
18
1
RXFIFOF
Receive FIFO full
17
1
TXFIFOF
Transmit FIFO full
16
1
RXFIFOHF
Receive FIFO half full: there are at
least 8 words in the FIFO
15
1
TXFIFOHE
Transmit FIFO half empty: at least 8
words can be written into the FIFO
14
1
RXACT
Data receive in progress
13
1
TXACT
Data transmit in progress
12
1
CMDACT
Command transfer in
progress
11
1
DBCKEND
Data block sent/received (CRC check
passed)
10
1
STBITERR
Start bit not detected on all data
signals in wide bus mode
9
1
DATAEND
Data end (data counter, SDIDCOUNT, is
zero)
8
1
CMDSENT
Command sent (no response
required)
7
1
CMDREND
Command response received (CRC check
passed)
6
1
RXOVERR
Received FIFO overrun
error
5
1
TXUNDERR
Transmit FIFO underrun
error
4
1
DTIMEOUT
Data timeout
3
1
CTIMEOUT
Command response timeout
2
1
DCRCFAIL
Data block sent/received (CRC check
failed)
1
1
CCRCFAIL
Command response received (CRC check
failed)
0
1
ICR
ICR
interrupt clear register
0x38
0x20
read-write
0x00000000
CEATAENDC
CEATAEND flag clear bit
23
1
SDIOITC
SDIOIT flag clear bit
22
1
DBCKENDC
DBCKEND flag clear bit
10
1
STBITERRC
STBITERR flag clear bit
9
1
DATAENDC
DATAEND flag clear bit
8
1
CMDSENTC
CMDSENT flag clear bit
7
1
CMDRENDC
CMDREND flag clear bit
6
1
RXOVERRC
RXOVERR flag clear bit
5
1
TXUNDERRC
TXUNDERR flag clear bit
4
1
DTIMEOUTC
DTIMEOUT flag clear bit
3
1
CTIMEOUTC
CTIMEOUT flag clear bit
2
1
DCRCFAILC
DCRCFAIL flag clear bit
1
1
CCRCFAILC
CCRCFAIL flag clear bit
0
1
MASK
MASK
mask register
0x3C
0x20
read-write
0x00000000
CEATAENDIE
CE-ATA command completion signal
received interrupt enable
23
1
SDIOITIE
SDIO mode interrupt received interrupt
enable
22
1
RXDAVLIE
Data available in Rx FIFO interrupt
enable
21
1
TXDAVLIE
Data available in Tx FIFO interrupt
enable
20
1
RXFIFOEIE
Rx FIFO empty interrupt
enable
19
1
TXFIFOEIE
Tx FIFO empty interrupt
enable
18
1
RXFIFOFIE
Rx FIFO full interrupt
enable
17
1
TXFIFOFIE
Tx FIFO full interrupt
enable
16
1
RXFIFOHFIE
Rx FIFO half full interrupt
enable
15
1
TXFIFOHEIE
Tx FIFO half empty interrupt
enable
14
1
RXACTIE
Data receive acting interrupt
enable
13
1
TXACTIE
Data transmit acting interrupt
enable
12
1
CMDACTIE
Command acting interrupt
enable
11
1
DBCKENDIE
Data block end interrupt
enable
10
1
STBITERRIE
Start bit error interrupt
enable
9
1
DATAENDIE
Data end interrupt enable
8
1
CMDSENTIE
Command sent interrupt
enable
7
1
CMDRENDIE
Command response received interrupt
enable
6
1
RXOVERRIE
Rx FIFO overrun error interrupt
enable
5
1
TXUNDERRIE
Tx FIFO underrun error interrupt
enable
4
1
DTIMEOUTIE
Data timeout interrupt
enable
3
1
CTIMEOUTIE
Command timeout interrupt
enable
2
1
DCRCFAILIE
Data CRC fail interrupt
enable
1
1
CCRCFAILIE
Command CRC fail interrupt
enable
0
1
FIFOCNT
FIFOCNT
FIFO counter register
0x48
0x20
read-only
0x00000000
FIFOCOUNT
Remaining number of words to be written
to or read from the FIFO
0
24
FIFO
FIFO
data FIFO register
0x80
0x20
read-write
0x00000000
FIFOData
Receive and transmit FIFO
data
0
32
EXTI
External interrupt/event
controller
EXTI
0x40010400
0x0
0x400
registers
PVD_PVM
PVD through EXTI line detection
1
EXTI0
EXTI Line 0 interrupt
6
EXTI1
EXTI Line 1 interrupt
7
EXTI2
EXTI Line 2 interrupt
8
EXTI3
EXTI Line 3 interrupt
9
EXTI4
EXTI Line 4 interrupt
10
EXTI9_5
EXTI Line5 to Line9 interrupts
23
EXTI15_10
EXTI Lines 10 to 15 interrupts
40
IMR1
IMR1
Interrupt mask register
0x0
0x20
read-write
0xFF820000
MR0
Interrupt Mask on line 0
0
1
MR1
Interrupt Mask on line 1
1
1
MR2
Interrupt Mask on line 2
2
1
MR3
Interrupt Mask on line 3
3
1
MR4
Interrupt Mask on line 4
4
1
MR5
Interrupt Mask on line 5
5
1
MR6
Interrupt Mask on line 6
6
1
MR7
Interrupt Mask on line 7
7
1
MR8
Interrupt Mask on line 8
8
1
MR9
Interrupt Mask on line 9
9
1
MR10
Interrupt Mask on line 10
10
1
MR11
Interrupt Mask on line 11
11
1
MR12
Interrupt Mask on line 12
12
1
MR13
Interrupt Mask on line 13
13
1
MR14
Interrupt Mask on line 14
14
1
MR15
Interrupt Mask on line 15
15
1
MR16
Interrupt Mask on line 16
16
1
MR17
Interrupt Mask on line 17
17
1
MR18
Interrupt Mask on line 18
18
1
MR19
Interrupt Mask on line 19
19
1
MR20
Interrupt Mask on line 20
20
1
MR21
Interrupt Mask on line 21
21
1
MR22
Interrupt Mask on line 22
22
1
MR23
Interrupt Mask on line 23
23
1
MR24
Interrupt Mask on line 24
24
1
MR25
Interrupt Mask on line 25
25
1
MR26
Interrupt Mask on line 26
26
1
MR27
Interrupt Mask on line 27
27
1
MR28
Interrupt Mask on line 28
28
1
MR29
Interrupt Mask on line 29
29
1
MR30
Interrupt Mask on line 30
30
1
MR31
Interrupt Mask on line 31
31
1
EMR1
EMR1
Event mask register
0x4
0x20
read-write
0x00000000
MR0
Event Mask on line 0
0
1
MR1
Event Mask on line 1
1
1
MR2
Event Mask on line 2
2
1
MR3
Event Mask on line 3
3
1
MR4
Event Mask on line 4
4
1
MR5
Event Mask on line 5
5
1
MR6
Event Mask on line 6
6
1
MR7
Event Mask on line 7
7
1
MR8
Event Mask on line 8
8
1
MR9
Event Mask on line 9
9
1
MR10
Event Mask on line 10
10
1
MR11
Event Mask on line 11
11
1
MR12
Event Mask on line 12
12
1
MR13
Event Mask on line 13
13
1
MR14
Event Mask on line 14
14
1
MR15
Event Mask on line 15
15
1
MR16
Event Mask on line 16
16
1
MR17
Event Mask on line 17
17
1
MR18
Event Mask on line 18
18
1
MR19
Event Mask on line 19
19
1
MR20
Event Mask on line 20
20
1
MR21
Event Mask on line 21
21
1
MR22
Event Mask on line 22
22
1
MR23
Event Mask on line 23
23
1
MR24
Event Mask on line 24
24
1
MR25
Event Mask on line 25
25
1
MR26
Event Mask on line 26
26
1
MR27
Event Mask on line 27
27
1
MR28
Event Mask on line 28
28
1
MR29
Event Mask on line 29
29
1
MR30
Event Mask on line 30
30
1
MR31
Event Mask on line 31
31
1
RTSR1
RTSR1
Rising Trigger selection
register
0x8
0x20
read-write
0x00000000
TR0
Rising trigger event configuration of
line 0
0
1
TR1
Rising trigger event configuration of
line 1
1
1
TR2
Rising trigger event configuration of
line 2
2
1
TR3
Rising trigger event configuration of
line 3
3
1
TR4
Rising trigger event configuration of
line 4
4
1
TR5
Rising trigger event configuration of
line 5
5
1
TR6
Rising trigger event configuration of
line 6
6
1
TR7
Rising trigger event configuration of
line 7
7
1
TR8
Rising trigger event configuration of
line 8
8
1
TR9
Rising trigger event configuration of
line 9
9
1
TR10
Rising trigger event configuration of
line 10
10
1
TR11
Rising trigger event configuration of
line 11
11
1
TR12
Rising trigger event configuration of
line 12
12
1
TR13
Rising trigger event configuration of
line 13
13
1
TR14
Rising trigger event configuration of
line 14
14
1
TR15
Rising trigger event configuration of
line 15
15
1
TR16
Rising trigger event configuration of
line 16
16
1
TR18
Rising trigger event configuration of
line 18
18
1
TR19
Rising trigger event configuration of
line 19
19
1
TR20
Rising trigger event configuration of
line 20
20
1
TR21
Rising trigger event configuration of
line 21
21
1
TR22
Rising trigger event configuration of
line 22
22
1
FTSR1
FTSR1
Falling Trigger selection
register
0xC
0x20
read-write
0x00000000
TR0
Falling trigger event configuration of
line 0
0
1
TR1
Falling trigger event configuration of
line 1
1
1
TR2
Falling trigger event configuration of
line 2
2
1
TR3
Falling trigger event configuration of
line 3
3
1
TR4
Falling trigger event configuration of
line 4
4
1
TR5
Falling trigger event configuration of
line 5
5
1
TR6
Falling trigger event configuration of
line 6
6
1
TR7
Falling trigger event configuration of
line 7
7
1
TR8
Falling trigger event configuration of
line 8
8
1
TR9
Falling trigger event configuration of
line 9
9
1
TR10
Falling trigger event configuration of
line 10
10
1
TR11
Falling trigger event configuration of
line 11
11
1
TR12
Falling trigger event configuration of
line 12
12
1
TR13
Falling trigger event configuration of
line 13
13
1
TR14
Falling trigger event configuration of
line 14
14
1
TR15
Falling trigger event configuration of
line 15
15
1
TR16
Falling trigger event configuration of
line 16
16
1
TR18
Falling trigger event configuration of
line 18
18
1
TR19
Falling trigger event configuration of
line 19
19
1
TR20
Falling trigger event configuration of
line 20
20
1
TR21
Falling trigger event configuration of
line 21
21
1
TR22
Falling trigger event configuration of
line 22
22
1
SWIER1
SWIER1
Software interrupt event
register
0x10
0x20
read-write
0x00000000
SWIER0
Software Interrupt on line
0
0
1
SWIER1
Software Interrupt on line
1
1
1
SWIER2
Software Interrupt on line
2
2
1
SWIER3
Software Interrupt on line
3
3
1
SWIER4
Software Interrupt on line
4
4
1
SWIER5
Software Interrupt on line
5
5
1
SWIER6
Software Interrupt on line
6
6
1
SWIER7
Software Interrupt on line
7
7
1
SWIER8
Software Interrupt on line
8
8
1
SWIER9
Software Interrupt on line
9
9
1
SWIER10
Software Interrupt on line
10
10
1
SWIER11
Software Interrupt on line
11
11
1
SWIER12
Software Interrupt on line
12
12
1
SWIER13
Software Interrupt on line
13
13
1
SWIER14
Software Interrupt on line
14
14
1
SWIER15
Software Interrupt on line
15
15
1
SWIER16
Software Interrupt on line
16
16
1
SWIER18
Software Interrupt on line
18
18
1
SWIER19
Software Interrupt on line
19
19
1
SWIER20
Software Interrupt on line
20
20
1
SWIER21
Software Interrupt on line
21
21
1
SWIER22
Software Interrupt on line
22
22
1
PR1
PR1
Pending register
0x14
0x20
read-write
0x00000000
PR0
Pending bit 0
0
1
PR1
Pending bit 1
1
1
PR2
Pending bit 2
2
1
PR3
Pending bit 3
3
1
PR4
Pending bit 4
4
1
PR5
Pending bit 5
5
1
PR6
Pending bit 6
6
1
PR7
Pending bit 7
7
1
PR8
Pending bit 8
8
1
PR9
Pending bit 9
9
1
PR10
Pending bit 10
10
1
PR11
Pending bit 11
11
1
PR12
Pending bit 12
12
1
PR13
Pending bit 13
13
1
PR14
Pending bit 14
14
1
PR15
Pending bit 15
15
1
PR16
Pending bit 16
16
1
PR18
Pending bit 18
18
1
PR19
Pending bit 19
19
1
PR20
Pending bit 20
20
1
PR21
Pending bit 21
21
1
PR22
Pending bit 22
22
1
IMR2
IMR2
Interrupt mask register
0x20
0x20
read-write
0xFFFFFF87
MR32
Interrupt Mask on external/internal line
32
0
1
MR33
Interrupt Mask on external/internal line
33
1
1
MR34
Interrupt Mask on external/internal line
34
2
1
MR35
Interrupt Mask on external/internal line
35
3
1
MR36
Interrupt Mask on external/internal line
36
4
1
MR37
Interrupt Mask on external/internal line
37
5
1
MR38
Interrupt Mask on external/internal line
38
6
1
MR39
Interrupt Mask on external/internal line
39
7
1
EMR2
EMR2
Event mask register
0x24
0x20
read-write
0x00000000
MR32
Event mask on external/internal line
32
0
1
MR33
Event mask on external/internal line
33
1
1
MR34
Event mask on external/internal line
34
2
1
MR35
Event mask on external/internal line
35
3
1
MR36
Event mask on external/internal line
36
4
1
MR37
Event mask on external/internal line
37
5
1
MR38
Event mask on external/internal line
38
6
1
MR39
Event mask on external/internal line
39
7
1
RTSR2
RTSR2
Rising Trigger selection
register
0x28
0x20
read-write
0x00000000
RT35
Rising trigger event configuration bit
of line 35
3
1
RT36
Rising trigger event configuration bit
of line 36
4
1
RT37
Rising trigger event configuration bit
of line 37
5
1
RT38
Rising trigger event configuration bit
of line 38
6
1
FTSR2
FTSR2
Falling Trigger selection
register
0x2C
0x20
read-write
0x00000000
FT35
Falling trigger event configuration bit
of line 35
3
1
FT36
Falling trigger event configuration bit
of line 36
4
1
FT37
Falling trigger event configuration bit
of line 37
5
1
FT38
Falling trigger event configuration bit
of line 38
6
1
SWIER2
SWIER2
Software interrupt event
register
0x30
0x20
read-write
0x00000000
SWI35
Software interrupt on line
35
3
1
SWI36
Software interrupt on line
36
4
1
SWI37
Software interrupt on line
37
5
1
SWI38
Software interrupt on line
38
6
1
PR2
PR2
Pending register
0x34
0x20
read-write
0x00000000
PIF35
Pending interrupt flag on line
35
3
1
PIF36
Pending interrupt flag on line
36
4
1
PIF37
Pending interrupt flag on line
37
5
1
PIF38
Pending interrupt flag on line
38
6
1
VREFBUF
Voltage reference buffer
VREF
0x40010030
0x0
0x1D0
registers
CSR
CSR
VREF control and status
register
0x0
0x20
0x00000002
ENVR
Voltage reference buffer
enable
0
1
read-write
HIZ
High impedance mode
1
1
read-write
VRS
Voltage reference scale
2
1
read-write
VRR
Voltage reference buffer
ready
3
1
read-only
CCR
CCR
calibration control register
0x4
0x20
read-write
0x00000000
TRIM
Trimming code
0
6
CAN1
Controller area network
CAN
0x40006400
0x0
0x400
registers
CAN1_TX
CAN1 TX interrupts
19
CAN1_RX0
CAN1 RX0 interrupts
20
CAN1_RX1
CAN1 RX1 interrupts
21
CAN1_SCE
CAN1 SCE interrupt
22
MCR
MCR
master control register
0x0
0x20
read-write
0x00010002
DBF
DBF
16
1
RESET
RESET
15
1
TTCM
TTCM
7
1
ABOM
ABOM
6
1
AWUM
AWUM
5
1
NART
NART
4
1
RFLM
RFLM
3
1
TXFP
TXFP
2
1
SLEEP
SLEEP
1
1
INRQ
INRQ
0
1
MSR
MSR
master status register
0x4
0x20
0x00000C02
RX
RX
11
1
read-only
SAMP
SAMP
10
1
read-only
RXM
RXM
9
1
read-only
TXM
TXM
8
1
read-only
SLAKI
SLAKI
4
1
read-write
WKUI
WKUI
3
1
read-write
ERRI
ERRI
2
1
read-write
SLAK
SLAK
1
1
read-only
INAK
INAK
0
1
read-only
TSR
TSR
transmit status register
0x8
0x20
0x1C000000
LOW2
Lowest priority flag for mailbox
2
31
1
read-only
LOW1
Lowest priority flag for mailbox
1
30
1
read-only
LOW0
Lowest priority flag for mailbox
0
29
1
read-only
TME2
Lowest priority flag for mailbox
2
28
1
read-only
TME1
Lowest priority flag for mailbox
1
27
1
read-only
TME0
Lowest priority flag for mailbox
0
26
1
read-only
CODE
CODE
24
2
read-only
ABRQ2
ABRQ2
23
1
read-write
TERR2
TERR2
19
1
read-write
ALST2
ALST2
18
1
read-write
TXOK2
TXOK2
17
1
read-write
RQCP2
RQCP2
16
1
read-write
ABRQ1
ABRQ1
15
1
read-write
TERR1
TERR1
11
1
read-write
ALST1
ALST1
10
1
read-write
TXOK1
TXOK1
9
1
read-write
RQCP1
RQCP1
8
1
read-write
ABRQ0
ABRQ0
7
1
read-write
TERR0
TERR0
3
1
read-write
ALST0
ALST0
2
1
read-write
TXOK0
TXOK0
1
1
read-write
RQCP0
RQCP0
0
1
read-write
RF0R
RF0R
receive FIFO 0 register
0xC
0x20
0x00000000
RFOM0
RFOM0
5
1
read-write
FOVR0
FOVR0
4
1
read-write
FULL0
FULL0
3
1
read-write
FMP0
FMP0
0
2
read-only
RF1R
RF1R
receive FIFO 1 register
0x10
0x20
0x00000000
RFOM1
RFOM1
5
1
read-write
FOVR1
FOVR1
4
1
read-write
FULL1
FULL1
3
1
read-write
FMP1
FMP1
0
2
read-only
IER
IER
interrupt enable register
0x14
0x20
read-write
0x00000000
SLKIE
SLKIE
17
1
WKUIE
WKUIE
16
1
ERRIE
ERRIE
15
1
LECIE
LECIE
11
1
BOFIE
BOFIE
10
1
EPVIE
EPVIE
9
1
EWGIE
EWGIE
8
1
FOVIE1
FOVIE1
6
1
FFIE1
FFIE1
5
1
FMPIE1
FMPIE1
4
1
FOVIE0
FOVIE0
3
1
FFIE0
FFIE0
2
1
FMPIE0
FMPIE0
1
1
TMEIE
TMEIE
0
1
ESR
ESR
interrupt enable register
0x18
0x20
0x00000000
REC
REC
24
8
read-only
TEC
TEC
16
8
read-only
LEC
LEC
4
3
read-write
BOFF
BOFF
2
1
read-only
EPVF
EPVF
1
1
read-only
EWGF
EWGF
0
1
read-only
BTR
BTR
bit timing register
0x1C
0x20
read-write
0x00000000
SILM
SILM
31
1
LBKM
LBKM
30
1
SJW
SJW
24
2
TS2
TS2
20
3
TS1
TS1
16
4
BRP
BRP
0
10
TI0R
TI0R
TX mailbox identifier register
0x180
0x20
read-write
0x00000000
STID
STID
21
11
EXID
EXID
3
18
IDE
IDE
2
1
RTR
RTR
1
1
TXRQ
TXRQ
0
1
TDT0R
TDT0R
mailbox data length control and time stamp
register
0x184
0x20
read-write
0x00000000
TIME
TIME
16
16
TGT
TGT
8
1
DLC
DLC
0
4
TDL0R
TDL0R
mailbox data low register
0x188
0x20
read-write
0x00000000
DATA3
DATA3
24
8
DATA2
DATA2
16
8
DATA1
DATA1
8
8
DATA0
DATA0
0
8
TDH0R
TDH0R
mailbox data high register
0x18C
0x20
read-write
0x00000000
DATA7
DATA7
24
8
DATA6
DATA6
16
8
DATA5
DATA5
8
8
DATA4
DATA4
0
8
TI1R
TI1R
mailbox identifier register
0x190
0x20
read-write
0x00000000
STID
STID
21
11
EXID
EXID
3
18
IDE
IDE
2
1
RTR
RTR
1
1
TXRQ
TXRQ
0
1
TDT1R
TDT1R
mailbox data length control and time stamp
register
0x194
0x20
read-write
0x00000000
TIME
TIME
16
16
TGT
TGT
8
1
DLC
DLC
0
4
TDL1R
TDL1R
mailbox data low register
0x198
0x20
read-write
0x00000000
DATA3
DATA3
24
8
DATA2
DATA2
16
8
DATA1
DATA1
8
8
DATA0
DATA0
0
8
TDH1R
TDH1R
mailbox data high register
0x19C
0x20
read-write
0x00000000
DATA7
DATA7
24
8
DATA6
DATA6
16
8
DATA5
DATA5
8
8
DATA4
DATA4
0
8
TI2R
TI2R
mailbox identifier register
0x1A0
0x20
read-write
0x00000000
STID
STID
21
11
EXID
EXID
3
18
IDE
IDE
2
1
RTR
RTR
1
1
TXRQ
TXRQ
0
1
TDT2R
TDT2R
mailbox data length control and time stamp
register
0x1A4
0x20
read-write
0x00000000
TIME
TIME
16
16
TGT
TGT
8
1
DLC
DLC
0
4
TDL2R
TDL2R
mailbox data low register
0x1A8
0x20
read-write
0x00000000
DATA3
DATA3
24
8
DATA2
DATA2
16
8
DATA1
DATA1
8
8
DATA0
DATA0
0
8
TDH2R
TDH2R
mailbox data high register
0x1AC
0x20
read-write
0x00000000
DATA7
DATA7
24
8
DATA6
DATA6
16
8
DATA5
DATA5
8
8
DATA4
DATA4
0
8
RI0R
RI0R
receive FIFO mailbox identifier
register
0x1B0
0x20
read-only
0x00000000
STID
STID
21
11
EXID
EXID
3
18
IDE
IDE
2
1
RTR
RTR
1
1
RDT0R
RDT0R
mailbox data high register
0x1B4
0x20
read-only
0x00000000
TIME
TIME
16
16
FMI
FMI
8
8
DLC
DLC
0
4
RDL0R
RDL0R
mailbox data high register
0x1B8
0x20
read-only
0x00000000
DATA3
DATA3
24
8
DATA2
DATA2
16
8
DATA1
DATA1
8
8
DATA0
DATA0
0
8
RDH0R
RDH0R
receive FIFO mailbox data high
register
0x1BC
0x20
read-only
0x00000000
DATA7
DATA7
24
8
DATA6
DATA6
16
8
DATA5
DATA5
8
8
DATA4
DATA4
0
8
RI1R
RI1R
mailbox data high register
0x1C0
0x20
read-only
0x00000000
STID
STID
21
11
EXID
EXID
3
18
IDE
IDE
2
1
RTR
RTR
1
1
RDT1R
RDT1R
mailbox data high register
0x1C4
0x20
read-only
0x00000000
TIME
TIME
16
16
FMI
FMI
8
8
DLC
DLC
0
4
RDL1R
RDL1R
mailbox data high register
0x1C8
0x20
read-only
0x00000000
DATA3
DATA3
24
8
DATA2
DATA2
16
8
DATA1
DATA1
8
8
DATA0
DATA0
0
8
RDH1R
RDH1R
mailbox data high register
0x1CC
0x20
read-only
0x00000000
DATA7
DATA7
24
8
DATA6
DATA6
16
8
DATA5
DATA5
8
8
DATA4
DATA4
0
8
FMR
FMR
filter master register
0x200
0x20
read-write
0x2A1C0E01
FINIT
Filter initialization mode
0
1
CANSB
CAN start bank
8
6
FM1R
FM1R
filter mode register
0x204
0x20
read-write
0x00000000
FBM0
Filter mode
0
1
FBM1
Filter mode
1
1
FBM2
Filter mode
2
1
FBM3
Filter mode
3
1
FBM4
Filter mode
4
1
FBM5
Filter mode
5
1
FBM6
Filter mode
6
1
FBM7
Filter mode
7
1
FBM8
Filter mode
8
1
FBM9
Filter mode
9
1
FBM10
Filter mode
10
1
FBM11
Filter mode
11
1
FBM12
Filter mode
12
1
FBM13
Filter mode
13
1
FBM14
Filter mode
14
1
FBM15
Filter mode
15
1
FBM16
Filter mode
16
1
FBM17
Filter mode
17
1
FBM18
Filter mode
18
1
FBM19
Filter mode
19
1
FBM20
Filter mode
20
1
FBM21
Filter mode
21
1
FBM22
Filter mode
22
1
FBM23
Filter mode
23
1
FBM24
Filter mode
24
1
FBM25
Filter mode
25
1
FBM26
Filter mode
26
1
FBM27
Filter mode
27
1
FS1R
FS1R
filter scale register
0x20C
0x20
read-write
0x00000000
FSC0
Filter scale configuration
0
1
FSC1
Filter scale configuration
1
1
FSC2
Filter scale configuration
2
1
FSC3
Filter scale configuration
3
1
FSC4
Filter scale configuration
4
1
FSC5
Filter scale configuration
5
1
FSC6
Filter scale configuration
6
1
FSC7
Filter scale configuration
7
1
FSC8
Filter scale configuration
8
1
FSC9
Filter scale configuration
9
1
FSC10
Filter scale configuration
10
1
FSC11
Filter scale configuration
11
1
FSC12
Filter scale configuration
12
1
FSC13
Filter scale configuration
13
1
FSC14
Filter scale configuration
14
1
FSC15
Filter scale configuration
15
1
FSC16
Filter scale configuration
16
1
FSC17
Filter scale configuration
17
1
FSC18
Filter scale configuration
18
1
FSC19
Filter scale configuration
19
1
FSC20
Filter scale configuration
20
1
FSC21
Filter scale configuration
21
1
FSC22
Filter scale configuration
22
1
FSC23
Filter scale configuration
23
1
FSC24
Filter scale configuration
24
1
FSC25
Filter scale configuration
25
1
FSC26
Filter scale configuration
26
1
FSC27
Filter scale configuration
27
1
FFA1R
FFA1R
filter FIFO assignment
register
0x214
0x20
read-write
0x00000000
FFA0
Filter FIFO assignment for filter
0
0
1
FFA1
Filter FIFO assignment for filter
1
1
1
FFA2
Filter FIFO assignment for filter
2
2
1
FFA3
Filter FIFO assignment for filter
3
3
1
FFA4
Filter FIFO assignment for filter
4
4
1
FFA5
Filter FIFO assignment for filter
5
5
1
FFA6
Filter FIFO assignment for filter
6
6
1
FFA7
Filter FIFO assignment for filter
7
7
1
FFA8
Filter FIFO assignment for filter
8
8
1
FFA9
Filter FIFO assignment for filter
9
9
1
FFA10
Filter FIFO assignment for filter
10
10
1
FFA11
Filter FIFO assignment for filter
11
11
1
FFA12
Filter FIFO assignment for filter
12
12
1
FFA13
Filter FIFO assignment for filter
13
13
1
FFA14
Filter FIFO assignment for
filter
14
1
FFA15
Filter FIFO assignment for
filter
15
1
FFA16
Filter FIFO assignment for
filter
16
1
FFA17
Filter FIFO assignment for
filter
17
1
FFA18
Filter FIFO assignment for
filter
18
1
FFA19
Filter FIFO assignment for
filter
19
1
FFA20
Filter FIFO assignment for
filter
20
1
FFA21
Filter FIFO assignment for
filter
21
1
FFA22
Filter FIFO assignment for
filter
22
1
FFA23
Filter FIFO assignment for
filter
23
1
FFA24
Filter FIFO assignment for
filter
24
1
FFA25
Filter FIFO assignment for
filter
25
1
FFA26
Filter FIFO assignment for
filter
26
1
FFA27
Filter FIFO assignment for
filter
27
1
FA1R
FA1R
filter activation register
0x21C
0x20
read-write
0x00000000
FACT0
Filter active
0
1
FACT1
Filter active
1
1
FACT2
Filter active
2
1
FACT3
Filter active
3
1
FACT4
Filter active
4
1
FACT5
Filter active
5
1
FACT6
Filter active
6
1
FACT7
Filter active
7
1
FACT8
Filter active
8
1
FACT9
Filter active
9
1
FACT10
Filter active
10
1
FACT11
Filter active
11
1
FACT12
Filter active
12
1
FACT13
Filter active
13
1
FACT14
Filter active
14
1
FACT15
Filter active
15
1
FACT16
Filter active
16
1
FACT17
Filter active
17
1
FACT18
Filter active
18
1
FACT19
Filter active
19
1
FACT20
Filter active
20
1
FACT21
Filter active
21
1
FACT22
Filter active
22
1
FACT23
Filter active
23
1
FACT24
Filter active
24
1
FACT25
Filter active
25
1
FACT26
Filter active
26
1
FACT27
Filter active
27
1
F0R1
F0R1
Filter bank 0 register 1
0x240
0x20
read-write
0x00000000
FB0
Filter bits
0
1
FB1
Filter bits
1
1
FB2
Filter bits
2
1
FB3
Filter bits
3
1
FB4
Filter bits
4
1
FB5
Filter bits
5
1
FB6
Filter bits
6
1
FB7
Filter bits
7
1
FB8
Filter bits
8
1
FB9
Filter bits
9
1
FB10
Filter bits
10
1
FB11
Filter bits
11
1
FB12
Filter bits
12
1
FB13
Filter bits
13
1
FB14
Filter bits
14
1
FB15
Filter bits
15
1
FB16
Filter bits
16
1
FB17
Filter bits
17
1
FB18
Filter bits
18
1
FB19
Filter bits
19
1
FB20
Filter bits
20
1
FB21
Filter bits
21
1
FB22
Filter bits
22
1
FB23
Filter bits
23
1
FB24
Filter bits
24
1
FB25
Filter bits
25
1
FB26
Filter bits
26
1
FB27
Filter bits
27
1
FB28
Filter bits
28
1
FB29
Filter bits
29
1
FB30
Filter bits
30
1
FB31
Filter bits
31
1
F0R2
F0R2
Filter bank 0 register 2
0x244
0x20
read-write
0x00000000
FB0
Filter bits
0
1
FB1
Filter bits
1
1
FB2
Filter bits
2
1
FB3
Filter bits
3
1
FB4
Filter bits
4
1
FB5
Filter bits
5
1
FB6
Filter bits
6
1
FB7
Filter bits
7
1
FB8
Filter bits
8
1
FB9
Filter bits
9
1
FB10
Filter bits
10
1
FB11
Filter bits
11
1
FB12
Filter bits
12
1
FB13
Filter bits
13
1
FB14
Filter bits
14
1
FB15
Filter bits
15
1
FB16
Filter bits
16
1
FB17
Filter bits
17
1
FB18
Filter bits
18
1
FB19
Filter bits
19
1
FB20
Filter bits
20
1
FB21
Filter bits
21
1
FB22
Filter bits
22
1
FB23
Filter bits
23
1
FB24
Filter bits
24
1
FB25
Filter bits
25
1
FB26
Filter bits
26
1
FB27
Filter bits
27
1
FB28
Filter bits
28
1
FB29
Filter bits
29
1
FB30
Filter bits
30
1
FB31
Filter bits
31
1
F1R1
F1R1
Filter bank 1 register 1
0x248
0x20
read-write
0x00000000
FB0
Filter bits
0
1
FB1
Filter bits
1
1
FB2
Filter bits
2
1
FB3
Filter bits
3
1
FB4
Filter bits
4
1
FB5
Filter bits
5
1
FB6
Filter bits
6
1
FB7
Filter bits
7
1
FB8
Filter bits
8
1
FB9
Filter bits
9
1
FB10
Filter bits
10
1
FB11
Filter bits
11
1
FB12
Filter bits
12
1
FB13
Filter bits
13
1
FB14
Filter bits
14
1
FB15
Filter bits
15
1
FB16
Filter bits
16
1
FB17
Filter bits
17
1
FB18
Filter bits
18
1
FB19
Filter bits
19
1
FB20
Filter bits
20
1
FB21
Filter bits
21
1
FB22
Filter bits
22
1
FB23
Filter bits
23
1
FB24
Filter bits
24
1
FB25
Filter bits
25
1
FB26
Filter bits
26
1
FB27
Filter bits
27
1
FB28
Filter bits
28
1
FB29
Filter bits
29
1
FB30
Filter bits
30
1
FB31
Filter bits
31
1
F1R2
F1R2
Filter bank 1 register 2
0x24C
0x20
read-write
0x00000000
FB0
Filter bits
0
1
FB1
Filter bits
1
1
FB2
Filter bits
2
1
FB3
Filter bits
3
1
FB4
Filter bits
4
1
FB5
Filter bits
5
1
FB6
Filter bits
6
1
FB7
Filter bits
7
1
FB8
Filter bits
8
1
FB9
Filter bits
9
1
FB10
Filter bits
10
1
FB11
Filter bits
11
1
FB12
Filter bits
12
1
FB13
Filter bits
13
1
FB14
Filter bits
14
1
FB15
Filter bits
15
1
FB16
Filter bits
16
1
FB17
Filter bits
17
1
FB18
Filter bits
18
1
FB19
Filter bits
19
1
FB20
Filter bits
20
1
FB21
Filter bits
21
1
FB22
Filter bits
22
1
FB23
Filter bits
23
1
FB24
Filter bits
24
1
FB25
Filter bits
25
1
FB26
Filter bits
26
1
FB27
Filter bits
27
1
FB28
Filter bits
28
1
FB29
Filter bits
29
1
FB30
Filter bits
30
1
FB31
Filter bits
31
1
F2R1
F2R1
Filter bank 2 register 1
0x250
0x20
read-write
0x00000000
FB0
Filter bits
0
1
FB1
Filter bits
1
1
FB2
Filter bits
2
1
FB3
Filter bits
3
1
FB4
Filter bits
4
1
FB5
Filter bits
5
1
FB6
Filter bits
6
1
FB7
Filter bits
7
1
FB8
Filter bits
8
1
FB9
Filter bits
9
1
FB10
Filter bits
10
1
FB11
Filter bits
11
1
FB12
Filter bits
12
1
FB13
Filter bits
13
1
FB14
Filter bits
14
1
FB15
Filter bits
15
1
FB16
Filter bits
16
1
FB17
Filter bits
17
1
FB18
Filter bits
18
1
FB19
Filter bits
19
1
FB20
Filter bits
20
1
FB21
Filter bits
21
1
FB22
Filter bits
22
1
FB23
Filter bits
23
1
FB24
Filter bits
24
1
FB25
Filter bits
25
1
FB26
Filter bits
26
1
FB27
Filter bits
27
1
FB28
Filter bits
28
1
FB29
Filter bits
29
1
FB30
Filter bits
30
1
FB31
Filter bits
31
1
F2R2
F2R2
Filter bank 2 register 2
0x254
0x20
read-write
0x00000000
FB0
Filter bits
0
1
FB1
Filter bits
1
1
FB2
Filter bits
2
1
FB3
Filter bits
3
1
FB4
Filter bits
4
1
FB5
Filter bits
5
1
FB6
Filter bits
6
1
FB7
Filter bits
7
1
FB8
Filter bits
8
1
FB9
Filter bits
9
1
FB10
Filter bits
10
1
FB11
Filter bits
11
1
FB12
Filter bits
12
1
FB13
Filter bits
13
1
FB14
Filter bits
14
1
FB15
Filter bits
15
1
FB16
Filter bits
16
1
FB17
Filter bits
17
1
FB18
Filter bits
18
1
FB19
Filter bits
19
1
FB20
Filter bits
20
1
FB21
Filter bits
21
1
FB22
Filter bits
22
1
FB23
Filter bits
23
1
FB24
Filter bits
24
1
FB25
Filter bits
25
1
FB26
Filter bits
26
1
FB27
Filter bits
27
1
FB28
Filter bits
28
1
FB29
Filter bits
29
1
FB30
Filter bits
30
1
FB31
Filter bits
31
1
F3R1
F3R1
Filter bank 3 register 1
0x258
0x20
read-write
0x00000000
FB0
Filter bits
0
1
FB1
Filter bits
1
1
FB2
Filter bits
2
1
FB3
Filter bits
3
1
FB4
Filter bits
4
1
FB5
Filter bits
5
1
FB6
Filter bits
6
1
FB7
Filter bits
7
1
FB8
Filter bits
8
1
FB9
Filter bits
9
1
FB10
Filter bits
10
1
FB11
Filter bits
11
1
FB12
Filter bits
12
1
FB13
Filter bits
13
1
FB14
Filter bits
14
1
FB15
Filter bits
15
1
FB16
Filter bits
16
1
FB17
Filter bits
17
1
FB18
Filter bits
18
1
FB19
Filter bits
19
1
FB20
Filter bits
20
1
FB21
Filter bits
21
1
FB22
Filter bits
22
1
FB23
Filter bits
23
1
FB24
Filter bits
24
1
FB25
Filter bits
25
1
FB26
Filter bits
26
1
FB27
Filter bits
27
1
FB28
Filter bits
28
1
FB29
Filter bits
29
1
FB30
Filter bits
30
1
FB31
Filter bits
31
1
F3R2
F3R2
Filter bank 3 register 2
0x25C
0x20
read-write
0x00000000
FB0
Filter bits
0
1
FB1
Filter bits
1
1
FB2
Filter bits
2
1
FB3
Filter bits
3
1
FB4
Filter bits
4
1
FB5
Filter bits
5
1
FB6
Filter bits
6
1
FB7
Filter bits
7
1
FB8
Filter bits
8
1
FB9
Filter bits
9
1
FB10
Filter bits
10
1
FB11
Filter bits
11
1
FB12
Filter bits
12
1
FB13
Filter bits
13
1
FB14
Filter bits
14
1
FB15
Filter bits
15
1
FB16
Filter bits
16
1
FB17
Filter bits
17
1
FB18
Filter bits
18
1
FB19
Filter bits
19
1
FB20
Filter bits
20
1
FB21
Filter bits
21
1
FB22
Filter bits
22
1
FB23
Filter bits
23
1
FB24
Filter bits
24
1
FB25
Filter bits
25
1
FB26
Filter bits
26
1
FB27
Filter bits
27
1
FB28
Filter bits
28
1
FB29
Filter bits
29
1
FB30
Filter bits
30
1
FB31
Filter bits
31
1
F4R1
F4R1
Filter bank 4 register 1
0x260
0x20
read-write
0x00000000
FB0
Filter bits
0
1
FB1
Filter bits
1
1
FB2
Filter bits
2
1
FB3
Filter bits
3
1
FB4
Filter bits
4
1
FB5
Filter bits
5
1
FB6
Filter bits
6
1
FB7
Filter bits
7
1
FB8
Filter bits
8
1
FB9
Filter bits
9
1
FB10
Filter bits
10
1
FB11
Filter bits
11
1
FB12
Filter bits
12
1
FB13
Filter bits
13
1
FB14
Filter bits
14
1
FB15
Filter bits
15
1
FB16
Filter bits
16
1
FB17
Filter bits
17
1
FB18
Filter bits
18
1
FB19
Filter bits
19
1
FB20
Filter bits
20
1
FB21
Filter bits
21
1
FB22
Filter bits
22
1
FB23
Filter bits
23
1
FB24
Filter bits
24
1
FB25
Filter bits
25
1
FB26
Filter bits
26
1
FB27
Filter bits
27
1
FB28
Filter bits
28
1
FB29
Filter bits
29
1
FB30
Filter bits
30
1
FB31
Filter bits
31
1
F4R2
F4R2
Filter bank 4 register 2
0x264
0x20
read-write
0x00000000
FB0
Filter bits
0
1
FB1
Filter bits
1
1
FB2
Filter bits
2
1
FB3
Filter bits
3
1
FB4
Filter bits
4
1
FB5
Filter bits
5
1
FB6
Filter bits
6
1
FB7
Filter bits
7
1
FB8
Filter bits
8
1
FB9
Filter bits
9
1
FB10
Filter bits
10
1
FB11
Filter bits
11
1
FB12
Filter bits
12
1
FB13
Filter bits
13
1
FB14
Filter bits
14
1
FB15
Filter bits
15
1
FB16
Filter bits
16
1
FB17
Filter bits
17
1
FB18
Filter bits
18
1
FB19
Filter bits
19
1
FB20
Filter bits
20
1
FB21
Filter bits
21
1
FB22
Filter bits
22
1
FB23
Filter bits
23
1
FB24
Filter bits
24
1
FB25
Filter bits
25
1
FB26
Filter bits
26
1
FB27
Filter bits
27
1
FB28
Filter bits
28
1
FB29
Filter bits
29
1
FB30
Filter bits
30
1
FB31
Filter bits
31
1
F5R1
F5R1
Filter bank 5 register 1
0x268
0x20
read-write
0x00000000
FB0
Filter bits
0
1
FB1
Filter bits
1
1
FB2
Filter bits
2
1
FB3
Filter bits
3
1
FB4
Filter bits
4
1
FB5
Filter bits
5
1
FB6
Filter bits
6
1
FB7
Filter bits
7
1
FB8
Filter bits
8
1
FB9
Filter bits
9
1
FB10
Filter bits
10
1
FB11
Filter bits
11
1
FB12
Filter bits
12
1
FB13
Filter bits
13
1
FB14
Filter bits
14
1
FB15
Filter bits
15
1
FB16
Filter bits
16
1
FB17
Filter bits
17
1
FB18
Filter bits
18
1
FB19
Filter bits
19
1
FB20
Filter bits
20
1
FB21
Filter bits
21
1
FB22
Filter bits
22
1
FB23
Filter bits
23
1
FB24
Filter bits
24
1
FB25
Filter bits
25
1
FB26
Filter bits
26
1
FB27
Filter bits
27
1
FB28
Filter bits
28
1
FB29
Filter bits
29
1
FB30
Filter bits
30
1
FB31
Filter bits
31
1
F5R2
F5R2
Filter bank 5 register 2
0x26C
0x20
read-write
0x00000000
FB0
Filter bits
0
1
FB1
Filter bits
1
1
FB2
Filter bits
2
1
FB3
Filter bits
3
1
FB4
Filter bits
4
1
FB5
Filter bits
5
1
FB6
Filter bits
6
1
FB7
Filter bits
7
1
FB8
Filter bits
8
1
FB9
Filter bits
9
1
FB10
Filter bits
10
1
FB11
Filter bits
11
1
FB12
Filter bits
12
1
FB13
Filter bits
13
1
FB14
Filter bits
14
1
FB15
Filter bits
15
1
FB16
Filter bits
16
1
FB17
Filter bits
17
1
FB18
Filter bits
18
1
FB19
Filter bits
19
1
FB20
Filter bits
20
1
FB21
Filter bits
21
1
FB22
Filter bits
22
1
FB23
Filter bits
23
1
FB24
Filter bits
24
1
FB25
Filter bits
25
1
FB26
Filter bits
26
1
FB27
Filter bits
27
1
FB28
Filter bits
28
1
FB29
Filter bits
29
1
FB30
Filter bits
30
1
FB31
Filter bits
31
1
F6R1
F6R1
Filter bank 6 register 1
0x270
0x20
read-write
0x00000000
FB0
Filter bits
0
1
FB1
Filter bits
1
1
FB2
Filter bits
2
1
FB3
Filter bits
3
1
FB4
Filter bits
4
1
FB5
Filter bits
5
1
FB6
Filter bits
6
1
FB7
Filter bits
7
1
FB8
Filter bits
8
1
FB9
Filter bits
9
1
FB10
Filter bits
10
1
FB11
Filter bits
11
1
FB12
Filter bits
12
1
FB13
Filter bits
13
1
FB14
Filter bits
14
1
FB15
Filter bits
15
1
FB16
Filter bits
16
1
FB17
Filter bits
17
1
FB18
Filter bits
18
1
FB19
Filter bits
19
1
FB20
Filter bits
20
1
FB21
Filter bits
21
1
FB22
Filter bits
22
1
FB23
Filter bits
23
1
FB24
Filter bits
24
1
FB25
Filter bits
25
1
FB26
Filter bits
26
1
FB27
Filter bits
27
1
FB28
Filter bits
28
1
FB29
Filter bits
29
1
FB30
Filter bits
30
1
FB31
Filter bits
31
1
F6R2
F6R2
Filter bank 6 register 2
0x274
0x20
read-write
0x00000000
FB0
Filter bits
0
1
FB1
Filter bits
1
1
FB2
Filter bits
2
1
FB3
Filter bits
3
1
FB4
Filter bits
4
1
FB5
Filter bits
5
1
FB6
Filter bits
6
1
FB7
Filter bits
7
1
FB8
Filter bits
8
1
FB9
Filter bits
9
1
FB10
Filter bits
10
1
FB11
Filter bits
11
1
FB12
Filter bits
12
1
FB13
Filter bits
13
1
FB14
Filter bits
14
1
FB15
Filter bits
15
1
FB16
Filter bits
16
1
FB17
Filter bits
17
1
FB18
Filter bits
18
1
FB19
Filter bits
19
1
FB20
Filter bits
20
1
FB21
Filter bits
21
1
FB22
Filter bits
22
1
FB23
Filter bits
23
1
FB24
Filter bits
24
1
FB25
Filter bits
25
1
FB26
Filter bits
26
1
FB27
Filter bits
27
1
FB28
Filter bits
28
1
FB29
Filter bits
29
1
FB30
Filter bits
30
1
FB31
Filter bits
31
1
F7R1
F7R1
Filter bank 7 register 1
0x278
0x20
read-write
0x00000000
FB0
Filter bits
0
1
FB1
Filter bits
1
1
FB2
Filter bits
2
1
FB3
Filter bits
3
1
FB4
Filter bits
4
1
FB5
Filter bits
5
1
FB6
Filter bits
6
1
FB7
Filter bits
7
1
FB8
Filter bits
8
1
FB9
Filter bits
9
1
FB10
Filter bits
10
1
FB11
Filter bits
11
1
FB12
Filter bits
12
1
FB13
Filter bits
13
1
FB14
Filter bits
14
1
FB15
Filter bits
15
1
FB16
Filter bits
16
1
FB17
Filter bits
17
1
FB18
Filter bits
18
1
FB19
Filter bits
19
1
FB20
Filter bits
20
1
FB21
Filter bits
21
1
FB22
Filter bits
22
1
FB23
Filter bits
23
1
FB24
Filter bits
24
1
FB25
Filter bits
25
1
FB26
Filter bits
26
1
FB27
Filter bits
27
1
FB28
Filter bits
28
1
FB29
Filter bits
29
1
FB30
Filter bits
30
1
FB31
Filter bits
31
1
F7R2
F7R2
Filter bank 7 register 2
0x27C
0x20
read-write
0x00000000
FB0
Filter bits
0
1
FB1
Filter bits
1
1
FB2
Filter bits
2
1
FB3
Filter bits
3
1
FB4
Filter bits
4
1
FB5
Filter bits
5
1
FB6
Filter bits
6
1
FB7
Filter bits
7
1
FB8
Filter bits
8
1
FB9
Filter bits
9
1
FB10
Filter bits
10
1
FB11
Filter bits
11
1
FB12
Filter bits
12
1
FB13
Filter bits
13
1
FB14
Filter bits
14
1
FB15
Filter bits
15
1
FB16
Filter bits
16
1
FB17
Filter bits
17
1
FB18
Filter bits
18
1
FB19
Filter bits
19
1
FB20
Filter bits
20
1
FB21
Filter bits
21
1
FB22
Filter bits
22
1
FB23
Filter bits
23
1
FB24
Filter bits
24
1
FB25
Filter bits
25
1
FB26
Filter bits
26
1
FB27
Filter bits
27
1
FB28
Filter bits
28
1
FB29
Filter bits
29
1
FB30
Filter bits
30
1
FB31
Filter bits
31
1
F8R1
F8R1
Filter bank 8 register 1
0x280
0x20
read-write
0x00000000
FB0
Filter bits
0
1
FB1
Filter bits
1
1
FB2
Filter bits
2
1
FB3
Filter bits
3
1
FB4
Filter bits
4
1
FB5
Filter bits
5
1
FB6
Filter bits
6
1
FB7
Filter bits
7
1
FB8
Filter bits
8
1
FB9
Filter bits
9
1
FB10
Filter bits
10
1
FB11
Filter bits
11
1
FB12
Filter bits
12
1
FB13
Filter bits
13
1
FB14
Filter bits
14
1
FB15
Filter bits
15
1
FB16
Filter bits
16
1
FB17
Filter bits
17
1
FB18
Filter bits
18
1
FB19
Filter bits
19
1
FB20
Filter bits
20
1
FB21
Filter bits
21
1
FB22
Filter bits
22
1
FB23
Filter bits
23
1
FB24
Filter bits
24
1
FB25
Filter bits
25
1
FB26
Filter bits
26
1
FB27
Filter bits
27
1
FB28
Filter bits
28
1
FB29
Filter bits
29
1
FB30
Filter bits
30
1
FB31
Filter bits
31
1
F8R2
F8R2
Filter bank 8 register 2
0x284
0x20
read-write
0x00000000
FB0
Filter bits
0
1
FB1
Filter bits
1
1
FB2
Filter bits
2
1
FB3
Filter bits
3
1
FB4
Filter bits
4
1
FB5
Filter bits
5
1
FB6
Filter bits
6
1
FB7
Filter bits
7
1
FB8
Filter bits
8
1
FB9
Filter bits
9
1
FB10
Filter bits
10
1
FB11
Filter bits
11
1
FB12
Filter bits
12
1
FB13
Filter bits
13
1
FB14
Filter bits
14
1
FB15
Filter bits
15
1
FB16
Filter bits
16
1
FB17
Filter bits
17
1
FB18
Filter bits
18
1
FB19
Filter bits
19
1
FB20
Filter bits
20
1
FB21
Filter bits
21
1
FB22
Filter bits
22
1
FB23
Filter bits
23
1
FB24
Filter bits
24
1
FB25
Filter bits
25
1
FB26
Filter bits
26
1
FB27
Filter bits
27
1
FB28
Filter bits
28
1
FB29
Filter bits
29
1
FB30
Filter bits
30
1
FB31
Filter bits
31
1
F9R1
F9R1
Filter bank 9 register 1
0x288
0x20
read-write
0x00000000
FB0
Filter bits
0
1
FB1
Filter bits
1
1
FB2
Filter bits
2
1
FB3
Filter bits
3
1
FB4
Filter bits
4
1
FB5
Filter bits
5
1
FB6
Filter bits
6
1
FB7
Filter bits
7
1
FB8
Filter bits
8
1
FB9
Filter bits
9
1
FB10
Filter bits
10
1
FB11
Filter bits
11
1
FB12
Filter bits
12
1
FB13
Filter bits
13
1
FB14
Filter bits
14
1
FB15
Filter bits
15
1
FB16
Filter bits
16
1
FB17
Filter bits
17
1
FB18
Filter bits
18
1
FB19
Filter bits
19
1
FB20
Filter bits
20
1
FB21
Filter bits
21
1
FB22
Filter bits
22
1
FB23
Filter bits
23
1
FB24
Filter bits
24
1
FB25
Filter bits
25
1
FB26
Filter bits
26
1
FB27
Filter bits
27
1
FB28
Filter bits
28
1
FB29
Filter bits
29
1
FB30
Filter bits
30
1
FB31
Filter bits
31
1
F9R2
F9R2
Filter bank 9 register 2
0x28C
0x20
read-write
0x00000000
FB0
Filter bits
0
1
FB1
Filter bits
1
1
FB2
Filter bits
2
1
FB3
Filter bits
3
1
FB4
Filter bits
4
1
FB5
Filter bits
5
1
FB6
Filter bits
6
1
FB7
Filter bits
7
1
FB8
Filter bits
8
1
FB9
Filter bits
9
1
FB10
Filter bits
10
1
FB11
Filter bits
11
1
FB12
Filter bits
12
1
FB13
Filter bits
13
1
FB14
Filter bits
14
1
FB15
Filter bits
15
1
FB16
Filter bits
16
1
FB17
Filter bits
17
1
FB18
Filter bits
18
1
FB19
Filter bits
19
1
FB20
Filter bits
20
1
FB21
Filter bits
21
1
FB22
Filter bits
22
1
FB23
Filter bits
23
1
FB24
Filter bits
24
1
FB25
Filter bits
25
1
FB26
Filter bits
26
1
FB27
Filter bits
27
1
FB28
Filter bits
28
1
FB29
Filter bits
29
1
FB30
Filter bits
30
1
FB31
Filter bits
31
1
F10R1
F10R1
Filter bank 10 register 1
0x290
0x20
read-write
0x00000000
FB0
Filter bits
0
1
FB1
Filter bits
1
1
FB2
Filter bits
2
1
FB3
Filter bits
3
1
FB4
Filter bits
4
1
FB5
Filter bits
5
1
FB6
Filter bits
6
1
FB7
Filter bits
7
1
FB8
Filter bits
8
1
FB9
Filter bits
9
1
FB10
Filter bits
10
1
FB11
Filter bits
11
1
FB12
Filter bits
12
1
FB13
Filter bits
13
1
FB14
Filter bits
14
1
FB15
Filter bits
15
1
FB16
Filter bits
16
1
FB17
Filter bits
17
1
FB18
Filter bits
18
1
FB19
Filter bits
19
1
FB20
Filter bits
20
1
FB21
Filter bits
21
1
FB22
Filter bits
22
1
FB23
Filter bits
23
1
FB24
Filter bits
24
1
FB25
Filter bits
25
1
FB26
Filter bits
26
1
FB27
Filter bits
27
1
FB28
Filter bits
28
1
FB29
Filter bits
29
1
FB30
Filter bits
30
1
FB31
Filter bits
31
1
F10R2
F10R2
Filter bank 10 register 2
0x294
0x20
read-write
0x00000000
FB0
Filter bits
0
1
FB1
Filter bits
1
1
FB2
Filter bits
2
1
FB3
Filter bits
3
1
FB4
Filter bits
4
1
FB5
Filter bits
5
1
FB6
Filter bits
6
1
FB7
Filter bits
7
1
FB8
Filter bits
8
1
FB9
Filter bits
9
1
FB10
Filter bits
10
1
FB11
Filter bits
11
1
FB12
Filter bits
12
1
FB13
Filter bits
13
1
FB14
Filter bits
14
1
FB15
Filter bits
15
1
FB16
Filter bits
16
1
FB17
Filter bits
17
1
FB18
Filter bits
18
1
FB19
Filter bits
19
1
FB20
Filter bits
20
1
FB21
Filter bits
21
1
FB22
Filter bits
22
1
FB23
Filter bits
23
1
FB24
Filter bits
24
1
FB25
Filter bits
25
1
FB26
Filter bits
26
1
FB27
Filter bits
27
1
FB28
Filter bits
28
1
FB29
Filter bits
29
1
FB30
Filter bits
30
1
FB31
Filter bits
31
1
F11R1
F11R1
Filter bank 11 register 1
0x298
0x20
read-write
0x00000000
FB0
Filter bits
0
1
FB1
Filter bits
1
1
FB2
Filter bits
2
1
FB3
Filter bits
3
1
FB4
Filter bits
4
1
FB5
Filter bits
5
1
FB6
Filter bits
6
1
FB7
Filter bits
7
1
FB8
Filter bits
8
1
FB9
Filter bits
9
1
FB10
Filter bits
10
1
FB11
Filter bits
11
1
FB12
Filter bits
12
1
FB13
Filter bits
13
1
FB14
Filter bits
14
1
FB15
Filter bits
15
1
FB16
Filter bits
16
1
FB17
Filter bits
17
1
FB18
Filter bits
18
1
FB19
Filter bits
19
1
FB20
Filter bits
20
1
FB21
Filter bits
21
1
FB22
Filter bits
22
1
FB23
Filter bits
23
1
FB24
Filter bits
24
1
FB25
Filter bits
25
1
FB26
Filter bits
26
1
FB27
Filter bits
27
1
FB28
Filter bits
28
1
FB29
Filter bits
29
1
FB30
Filter bits
30
1
FB31
Filter bits
31
1
F11R2
F11R2
Filter bank 11 register 2
0x29C
0x20
read-write
0x00000000
FB0
Filter bits
0
1
FB1
Filter bits
1
1
FB2
Filter bits
2
1
FB3
Filter bits
3
1
FB4
Filter bits
4
1
FB5
Filter bits
5
1
FB6
Filter bits
6
1
FB7
Filter bits
7
1
FB8
Filter bits
8
1
FB9
Filter bits
9
1
FB10
Filter bits
10
1
FB11
Filter bits
11
1
FB12
Filter bits
12
1
FB13
Filter bits
13
1
FB14
Filter bits
14
1
FB15
Filter bits
15
1
FB16
Filter bits
16
1
FB17
Filter bits
17
1
FB18
Filter bits
18
1
FB19
Filter bits
19
1
FB20
Filter bits
20
1
FB21
Filter bits
21
1
FB22
Filter bits
22
1
FB23
Filter bits
23
1
FB24
Filter bits
24
1
FB25
Filter bits
25
1
FB26
Filter bits
26
1
FB27
Filter bits
27
1
FB28
Filter bits
28
1
FB29
Filter bits
29
1
FB30
Filter bits
30
1
FB31
Filter bits
31
1
F12R1
F12R1
Filter bank 4 register 1
0x2A0
0x20
read-write
0x00000000
FB0
Filter bits
0
1
FB1
Filter bits
1
1
FB2
Filter bits
2
1
FB3
Filter bits
3
1
FB4
Filter bits
4
1
FB5
Filter bits
5
1
FB6
Filter bits
6
1
FB7
Filter bits
7
1
FB8
Filter bits
8
1
FB9
Filter bits
9
1
FB10
Filter bits
10
1
FB11
Filter bits
11
1
FB12
Filter bits
12
1
FB13
Filter bits
13
1
FB14
Filter bits
14
1
FB15
Filter bits
15
1
FB16
Filter bits
16
1
FB17
Filter bits
17
1
FB18
Filter bits
18
1
FB19
Filter bits
19
1
FB20
Filter bits
20
1
FB21
Filter bits
21
1
FB22
Filter bits
22
1
FB23
Filter bits
23
1
FB24
Filter bits
24
1
FB25
Filter bits
25
1
FB26
Filter bits
26
1
FB27
Filter bits
27
1
FB28
Filter bits
28
1
FB29
Filter bits
29
1
FB30
Filter bits
30
1
FB31
Filter bits
31
1
F12R2
F12R2
Filter bank 12 register 2
0x2A4
0x20
read-write
0x00000000
FB0
Filter bits
0
1
FB1
Filter bits
1
1
FB2
Filter bits
2
1
FB3
Filter bits
3
1
FB4
Filter bits
4
1
FB5
Filter bits
5
1
FB6
Filter bits
6
1
FB7
Filter bits
7
1
FB8
Filter bits
8
1
FB9
Filter bits
9
1
FB10
Filter bits
10
1
FB11
Filter bits
11
1
FB12
Filter bits
12
1
FB13
Filter bits
13
1
FB14
Filter bits
14
1
FB15
Filter bits
15
1
FB16
Filter bits
16
1
FB17
Filter bits
17
1
FB18
Filter bits
18
1
FB19
Filter bits
19
1
FB20
Filter bits
20
1
FB21
Filter bits
21
1
FB22
Filter bits
22
1
FB23
Filter bits
23
1
FB24
Filter bits
24
1
FB25
Filter bits
25
1
FB26
Filter bits
26
1
FB27
Filter bits
27
1
FB28
Filter bits
28
1
FB29
Filter bits
29
1
FB30
Filter bits
30
1
FB31
Filter bits
31
1
F13R1
F13R1
Filter bank 13 register 1
0x2A8
0x20
read-write
0x00000000
FB0
Filter bits
0
1
FB1
Filter bits
1
1
FB2
Filter bits
2
1
FB3
Filter bits
3
1
FB4
Filter bits
4
1
FB5
Filter bits
5
1
FB6
Filter bits
6
1
FB7
Filter bits
7
1
FB8
Filter bits
8
1
FB9
Filter bits
9
1
FB10
Filter bits
10
1
FB11
Filter bits
11
1
FB12
Filter bits
12
1
FB13
Filter bits
13
1
FB14
Filter bits
14
1
FB15
Filter bits
15
1
FB16
Filter bits
16
1
FB17
Filter bits
17
1
FB18
Filter bits
18
1
FB19
Filter bits
19
1
FB20
Filter bits
20
1
FB21
Filter bits
21
1
FB22
Filter bits
22
1
FB23
Filter bits
23
1
FB24
Filter bits
24
1
FB25
Filter bits
25
1
FB26
Filter bits
26
1
FB27
Filter bits
27
1
FB28
Filter bits
28
1
FB29
Filter bits
29
1
FB30
Filter bits
30
1
FB31
Filter bits
31
1
F13R2
F13R2
Filter bank 13 register 2
0x2AC
0x20
read-write
0x00000000
FB0
Filter bits
0
1
FB1
Filter bits
1
1
FB2
Filter bits
2
1
FB3
Filter bits
3
1
FB4
Filter bits
4
1
FB5
Filter bits
5
1
FB6
Filter bits
6
1
FB7
Filter bits
7
1
FB8
Filter bits
8
1
FB9
Filter bits
9
1
FB10
Filter bits
10
1
FB11
Filter bits
11
1
FB12
Filter bits
12
1
FB13
Filter bits
13
1
FB14
Filter bits
14
1
FB15
Filter bits
15
1
FB16
Filter bits
16
1
FB17
Filter bits
17
1
FB18
Filter bits
18
1
FB19
Filter bits
19
1
FB20
Filter bits
20
1
FB21
Filter bits
21
1
FB22
Filter bits
22
1
FB23
Filter bits
23
1
FB24
Filter bits
24
1
FB25
Filter bits
25
1
FB26
Filter bits
26
1
FB27
Filter bits
27
1
FB28
Filter bits
28
1
FB29
Filter bits
29
1
FB30
Filter bits
30
1
FB31
Filter bits
31
1
F14R1
F14R1
Filter bank 14 register 1
0x2B0
0x20
read-write
0x00000000
FB0
Filter bits
0
1
FB1
Filter bits
1
1
FB2
Filter bits
2
1
FB3
Filter bits
3
1
FB4
Filter bits
4
1
FB5
Filter bits
5
1
FB6
Filter bits
6
1
FB7
Filter bits
7
1
FB8
Filter bits
8
1
FB9
Filter bits
9
1
FB10
Filter bits
10
1
FB11
Filter bits
11
1
FB12
Filter bits
12
1
FB13
Filter bits
13
1
FB14
Filter bits
14
1
FB15
Filter bits
15
1
FB16
Filter bits
16
1
FB17
Filter bits
17
1
FB18
Filter bits
18
1
FB19
Filter bits
19
1
FB20
Filter bits
20
1
FB21
Filter bits
21
1
FB22
Filter bits
22
1
FB23
Filter bits
23
1
FB24
Filter bits
24
1
FB25
Filter bits
25
1
FB26
Filter bits
26
1
FB27
Filter bits
27
1
FB28
Filter bits
28
1
FB29
Filter bits
29
1
FB30
Filter bits
30
1
FB31
Filter bits
31
1
F14R2
F14R2
Filter bank 14 register 2
0x2B4
0x20
read-write
0x00000000
FB0
Filter bits
0
1
FB1
Filter bits
1
1
FB2
Filter bits
2
1
FB3
Filter bits
3
1
FB4
Filter bits
4
1
FB5
Filter bits
5
1
FB6
Filter bits
6
1
FB7
Filter bits
7
1
FB8
Filter bits
8
1
FB9
Filter bits
9
1
FB10
Filter bits
10
1
FB11
Filter bits
11
1
FB12
Filter bits
12
1
FB13
Filter bits
13
1
FB14
Filter bits
14
1
FB15
Filter bits
15
1
FB16
Filter bits
16
1
FB17
Filter bits
17
1
FB18
Filter bits
18
1
FB19
Filter bits
19
1
FB20
Filter bits
20
1
FB21
Filter bits
21
1
FB22
Filter bits
22
1
FB23
Filter bits
23
1
FB24
Filter bits
24
1
FB25
Filter bits
25
1
FB26
Filter bits
26
1
FB27
Filter bits
27
1
FB28
Filter bits
28
1
FB29
Filter bits
29
1
FB30
Filter bits
30
1
FB31
Filter bits
31
1
F15R1
F15R1
Filter bank 15 register 1
0x2B8
0x20
read-write
0x00000000
FB0
Filter bits
0
1
FB1
Filter bits
1
1
FB2
Filter bits
2
1
FB3
Filter bits
3
1
FB4
Filter bits
4
1
FB5
Filter bits
5
1
FB6
Filter bits
6
1
FB7
Filter bits
7
1
FB8
Filter bits
8
1
FB9
Filter bits
9
1
FB10
Filter bits
10
1
FB11
Filter bits
11
1
FB12
Filter bits
12
1
FB13
Filter bits
13
1
FB14
Filter bits
14
1
FB15
Filter bits
15
1
FB16
Filter bits
16
1
FB17
Filter bits
17
1
FB18
Filter bits
18
1
FB19
Filter bits
19
1
FB20
Filter bits
20
1
FB21
Filter bits
21
1
FB22
Filter bits
22
1
FB23
Filter bits
23
1
FB24
Filter bits
24
1
FB25
Filter bits
25
1
FB26
Filter bits
26
1
FB27
Filter bits
27
1
FB28
Filter bits
28
1
FB29
Filter bits
29
1
FB30
Filter bits
30
1
FB31
Filter bits
31
1
F15R2
F15R2
Filter bank 15 register 2
0x2BC
0x20
read-write
0x00000000
FB0
Filter bits
0
1
FB1
Filter bits
1
1
FB2
Filter bits
2
1
FB3
Filter bits
3
1
FB4
Filter bits
4
1
FB5
Filter bits
5
1
FB6
Filter bits
6
1
FB7
Filter bits
7
1
FB8
Filter bits
8
1
FB9
Filter bits
9
1
FB10
Filter bits
10
1
FB11
Filter bits
11
1
FB12
Filter bits
12
1
FB13
Filter bits
13
1
FB14
Filter bits
14
1
FB15
Filter bits
15
1
FB16
Filter bits
16
1
FB17
Filter bits
17
1
FB18
Filter bits
18
1
FB19
Filter bits
19
1
FB20
Filter bits
20
1
FB21
Filter bits
21
1
FB22
Filter bits
22
1
FB23
Filter bits
23
1
FB24
Filter bits
24
1
FB25
Filter bits
25
1
FB26
Filter bits
26
1
FB27
Filter bits
27
1
FB28
Filter bits
28
1
FB29
Filter bits
29
1
FB30
Filter bits
30
1
FB31
Filter bits
31
1
F16R1
F16R1
Filter bank 16 register 1
0x2C0
0x20
read-write
0x00000000
FB0
Filter bits
0
1
FB1
Filter bits
1
1
FB2
Filter bits
2
1
FB3
Filter bits
3
1
FB4
Filter bits
4
1
FB5
Filter bits
5
1
FB6
Filter bits
6
1
FB7
Filter bits
7
1
FB8
Filter bits
8
1
FB9
Filter bits
9
1
FB10
Filter bits
10
1
FB11
Filter bits
11
1
FB12
Filter bits
12
1
FB13
Filter bits
13
1
FB14
Filter bits
14
1
FB15
Filter bits
15
1
FB16
Filter bits
16
1
FB17
Filter bits
17
1
FB18
Filter bits
18
1
FB19
Filter bits
19
1
FB20
Filter bits
20
1
FB21
Filter bits
21
1
FB22
Filter bits
22
1
FB23
Filter bits
23
1
FB24
Filter bits
24
1
FB25
Filter bits
25
1
FB26
Filter bits
26
1
FB27
Filter bits
27
1
FB28
Filter bits
28
1
FB29
Filter bits
29
1
FB30
Filter bits
30
1
FB31
Filter bits
31
1
F16R2
F16R2
Filter bank 16 register 2
0x2C4
0x20
read-write
0x00000000
FB0
Filter bits
0
1
FB1
Filter bits
1
1
FB2
Filter bits
2
1
FB3
Filter bits
3
1
FB4
Filter bits
4
1
FB5
Filter bits
5
1
FB6
Filter bits
6
1
FB7
Filter bits
7
1
FB8
Filter bits
8
1
FB9
Filter bits
9
1
FB10
Filter bits
10
1
FB11
Filter bits
11
1
FB12
Filter bits
12
1
FB13
Filter bits
13
1
FB14
Filter bits
14
1
FB15
Filter bits
15
1
FB16
Filter bits
16
1
FB17
Filter bits
17
1
FB18
Filter bits
18
1
FB19
Filter bits
19
1
FB20
Filter bits
20
1
FB21
Filter bits
21
1
FB22
Filter bits
22
1
FB23
Filter bits
23
1
FB24
Filter bits
24
1
FB25
Filter bits
25
1
FB26
Filter bits
26
1
FB27
Filter bits
27
1
FB28
Filter bits
28
1
FB29
Filter bits
29
1
FB30
Filter bits
30
1
FB31
Filter bits
31
1
F17R1
F17R1
Filter bank 17 register 1
0x2C8
0x20
read-write
0x00000000
FB0
Filter bits
0
1
FB1
Filter bits
1
1
FB2
Filter bits
2
1
FB3
Filter bits
3
1
FB4
Filter bits
4
1
FB5
Filter bits
5
1
FB6
Filter bits
6
1
FB7
Filter bits
7
1
FB8
Filter bits
8
1
FB9
Filter bits
9
1
FB10
Filter bits
10
1
FB11
Filter bits
11
1
FB12
Filter bits
12
1
FB13
Filter bits
13
1
FB14
Filter bits
14
1
FB15
Filter bits
15
1
FB16
Filter bits
16
1
FB17
Filter bits
17
1
FB18
Filter bits
18
1
FB19
Filter bits
19
1
FB20
Filter bits
20
1
FB21
Filter bits
21
1
FB22
Filter bits
22
1
FB23
Filter bits
23
1
FB24
Filter bits
24
1
FB25
Filter bits
25
1
FB26
Filter bits
26
1
FB27
Filter bits
27
1
FB28
Filter bits
28
1
FB29
Filter bits
29
1
FB30
Filter bits
30
1
FB31
Filter bits
31
1
F17R2
F17R2
Filter bank 17 register 2
0x2CC
0x20
read-write
0x00000000
FB0
Filter bits
0
1
FB1
Filter bits
1
1
FB2
Filter bits
2
1
FB3
Filter bits
3
1
FB4
Filter bits
4
1
FB5
Filter bits
5
1
FB6
Filter bits
6
1
FB7
Filter bits
7
1
FB8
Filter bits
8
1
FB9
Filter bits
9
1
FB10
Filter bits
10
1
FB11
Filter bits
11
1
FB12
Filter bits
12
1
FB13
Filter bits
13
1
FB14
Filter bits
14
1
FB15
Filter bits
15
1
FB16
Filter bits
16
1
FB17
Filter bits
17
1
FB18
Filter bits
18
1
FB19
Filter bits
19
1
FB20
Filter bits
20
1
FB21
Filter bits
21
1
FB22
Filter bits
22
1
FB23
Filter bits
23
1
FB24
Filter bits
24
1
FB25
Filter bits
25
1
FB26
Filter bits
26
1
FB27
Filter bits
27
1
FB28
Filter bits
28
1
FB29
Filter bits
29
1
FB30
Filter bits
30
1
FB31
Filter bits
31
1
F18R1
F18R1
Filter bank 18 register 1
0x2D0
0x20
read-write
0x00000000
FB0
Filter bits
0
1
FB1
Filter bits
1
1
FB2
Filter bits
2
1
FB3
Filter bits
3
1
FB4
Filter bits
4
1
FB5
Filter bits
5
1
FB6
Filter bits
6
1
FB7
Filter bits
7
1
FB8
Filter bits
8
1
FB9
Filter bits
9
1
FB10
Filter bits
10
1
FB11
Filter bits
11
1
FB12
Filter bits
12
1
FB13
Filter bits
13
1
FB14
Filter bits
14
1
FB15
Filter bits
15
1
FB16
Filter bits
16
1
FB17
Filter bits
17
1
FB18
Filter bits
18
1
FB19
Filter bits
19
1
FB20
Filter bits
20
1
FB21
Filter bits
21
1
FB22
Filter bits
22
1
FB23
Filter bits
23
1
FB24
Filter bits
24
1
FB25
Filter bits
25
1
FB26
Filter bits
26
1
FB27
Filter bits
27
1
FB28
Filter bits
28
1
FB29
Filter bits
29
1
FB30
Filter bits
30
1
FB31
Filter bits
31
1
F18R2
F18R2
Filter bank 18 register 2
0x2D4
0x20
read-write
0x00000000
FB0
Filter bits
0
1
FB1
Filter bits
1
1
FB2
Filter bits
2
1
FB3
Filter bits
3
1
FB4
Filter bits
4
1
FB5
Filter bits
5
1
FB6
Filter bits
6
1
FB7
Filter bits
7
1
FB8
Filter bits
8
1
FB9
Filter bits
9
1
FB10
Filter bits
10
1
FB11
Filter bits
11
1
FB12
Filter bits
12
1
FB13
Filter bits
13
1
FB14
Filter bits
14
1
FB15
Filter bits
15
1
FB16
Filter bits
16
1
FB17
Filter bits
17
1
FB18
Filter bits
18
1
FB19
Filter bits
19
1
FB20
Filter bits
20
1
FB21
Filter bits
21
1
FB22
Filter bits
22
1
FB23
Filter bits
23
1
FB24
Filter bits
24
1
FB25
Filter bits
25
1
FB26
Filter bits
26
1
FB27
Filter bits
27
1
FB28
Filter bits
28
1
FB29
Filter bits
29
1
FB30
Filter bits
30
1
FB31
Filter bits
31
1
F19R1
F19R1
Filter bank 19 register 1
0x2D8
0x20
read-write
0x00000000
FB0
Filter bits
0
1
FB1
Filter bits
1
1
FB2
Filter bits
2
1
FB3
Filter bits
3
1
FB4
Filter bits
4
1
FB5
Filter bits
5
1
FB6
Filter bits
6
1
FB7
Filter bits
7
1
FB8
Filter bits
8
1
FB9
Filter bits
9
1
FB10
Filter bits
10
1
FB11
Filter bits
11
1
FB12
Filter bits
12
1
FB13
Filter bits
13
1
FB14
Filter bits
14
1
FB15
Filter bits
15
1
FB16
Filter bits
16
1
FB17
Filter bits
17
1
FB18
Filter bits
18
1
FB19
Filter bits
19
1
FB20
Filter bits
20
1
FB21
Filter bits
21
1
FB22
Filter bits
22
1
FB23
Filter bits
23
1
FB24
Filter bits
24
1
FB25
Filter bits
25
1
FB26
Filter bits
26
1
FB27
Filter bits
27
1
FB28
Filter bits
28
1
FB29
Filter bits
29
1
FB30
Filter bits
30
1
FB31
Filter bits
31
1
F19R2
F19R2
Filter bank 19 register 2
0x2DC
0x20
read-write
0x00000000
FB0
Filter bits
0
1
FB1
Filter bits
1
1
FB2
Filter bits
2
1
FB3
Filter bits
3
1
FB4
Filter bits
4
1
FB5
Filter bits
5
1
FB6
Filter bits
6
1
FB7
Filter bits
7
1
FB8
Filter bits
8
1
FB9
Filter bits
9
1
FB10
Filter bits
10
1
FB11
Filter bits
11
1
FB12
Filter bits
12
1
FB13
Filter bits
13
1
FB14
Filter bits
14
1
FB15
Filter bits
15
1
FB16
Filter bits
16
1
FB17
Filter bits
17
1
FB18
Filter bits
18
1
FB19
Filter bits
19
1
FB20
Filter bits
20
1
FB21
Filter bits
21
1
FB22
Filter bits
22
1
FB23
Filter bits
23
1
FB24
Filter bits
24
1
FB25
Filter bits
25
1
FB26
Filter bits
26
1
FB27
Filter bits
27
1
FB28
Filter bits
28
1
FB29
Filter bits
29
1
FB30
Filter bits
30
1
FB31
Filter bits
31
1
F20R1
F20R1
Filter bank 20 register 1
0x2E0
0x20
read-write
0x00000000
FB0
Filter bits
0
1
FB1
Filter bits
1
1
FB2
Filter bits
2
1
FB3
Filter bits
3
1
FB4
Filter bits
4
1
FB5
Filter bits
5
1
FB6
Filter bits
6
1
FB7
Filter bits
7
1
FB8
Filter bits
8
1
FB9
Filter bits
9
1
FB10
Filter bits
10
1
FB11
Filter bits
11
1
FB12
Filter bits
12
1
FB13
Filter bits
13
1
FB14
Filter bits
14
1
FB15
Filter bits
15
1
FB16
Filter bits
16
1
FB17
Filter bits
17
1
FB18
Filter bits
18
1
FB19
Filter bits
19
1
FB20
Filter bits
20
1
FB21
Filter bits
21
1
FB22
Filter bits
22
1
FB23
Filter bits
23
1
FB24
Filter bits
24
1
FB25
Filter bits
25
1
FB26
Filter bits
26
1
FB27
Filter bits
27
1
FB28
Filter bits
28
1
FB29
Filter bits
29
1
FB30
Filter bits
30
1
FB31
Filter bits
31
1
F20R2
F20R2
Filter bank 20 register 2
0x2E4
0x20
read-write
0x00000000
FB0
Filter bits
0
1
FB1
Filter bits
1
1
FB2
Filter bits
2
1
FB3
Filter bits
3
1
FB4
Filter bits
4
1
FB5
Filter bits
5
1
FB6
Filter bits
6
1
FB7
Filter bits
7
1
FB8
Filter bits
8
1
FB9
Filter bits
9
1
FB10
Filter bits
10
1
FB11
Filter bits
11
1
FB12
Filter bits
12
1
FB13
Filter bits
13
1
FB14
Filter bits
14
1
FB15
Filter bits
15
1
FB16
Filter bits
16
1
FB17
Filter bits
17
1
FB18
Filter bits
18
1
FB19
Filter bits
19
1
FB20
Filter bits
20
1
FB21
Filter bits
21
1
FB22
Filter bits
22
1
FB23
Filter bits
23
1
FB24
Filter bits
24
1
FB25
Filter bits
25
1
FB26
Filter bits
26
1
FB27
Filter bits
27
1
FB28
Filter bits
28
1
FB29
Filter bits
29
1
FB30
Filter bits
30
1
FB31
Filter bits
31
1
F21R1
F21R1
Filter bank 21 register 1
0x2E8
0x20
read-write
0x00000000
FB0
Filter bits
0
1
FB1
Filter bits
1
1
FB2
Filter bits
2
1
FB3
Filter bits
3
1
FB4
Filter bits
4
1
FB5
Filter bits
5
1
FB6
Filter bits
6
1
FB7
Filter bits
7
1
FB8
Filter bits
8
1
FB9
Filter bits
9
1
FB10
Filter bits
10
1
FB11
Filter bits
11
1
FB12
Filter bits
12
1
FB13
Filter bits
13
1
FB14
Filter bits
14
1
FB15
Filter bits
15
1
FB16
Filter bits
16
1
FB17
Filter bits
17
1
FB18
Filter bits
18
1
FB19
Filter bits
19
1
FB20
Filter bits
20
1
FB21
Filter bits
21
1
FB22
Filter bits
22
1
FB23
Filter bits
23
1
FB24
Filter bits
24
1
FB25
Filter bits
25
1
FB26
Filter bits
26
1
FB27
Filter bits
27
1
FB28
Filter bits
28
1
FB29
Filter bits
29
1
FB30
Filter bits
30
1
FB31
Filter bits
31
1
F21R2
F21R2
Filter bank 21 register 2
0x2EC
0x20
read-write
0x00000000
FB0
Filter bits
0
1
FB1
Filter bits
1
1
FB2
Filter bits
2
1
FB3
Filter bits
3
1
FB4
Filter bits
4
1
FB5
Filter bits
5
1
FB6
Filter bits
6
1
FB7
Filter bits
7
1
FB8
Filter bits
8
1
FB9
Filter bits
9
1
FB10
Filter bits
10
1
FB11
Filter bits
11
1
FB12
Filter bits
12
1
FB13
Filter bits
13
1
FB14
Filter bits
14
1
FB15
Filter bits
15
1
FB16
Filter bits
16
1
FB17
Filter bits
17
1
FB18
Filter bits
18
1
FB19
Filter bits
19
1
FB20
Filter bits
20
1
FB21
Filter bits
21
1
FB22
Filter bits
22
1
FB23
Filter bits
23
1
FB24
Filter bits
24
1
FB25
Filter bits
25
1
FB26
Filter bits
26
1
FB27
Filter bits
27
1
FB28
Filter bits
28
1
FB29
Filter bits
29
1
FB30
Filter bits
30
1
FB31
Filter bits
31
1
F22R1
F22R1
Filter bank 22 register 1
0x2F0
0x20
read-write
0x00000000
FB0
Filter bits
0
1
FB1
Filter bits
1
1
FB2
Filter bits
2
1
FB3
Filter bits
3
1
FB4
Filter bits
4
1
FB5
Filter bits
5
1
FB6
Filter bits
6
1
FB7
Filter bits
7
1
FB8
Filter bits
8
1
FB9
Filter bits
9
1
FB10
Filter bits
10
1
FB11
Filter bits
11
1
FB12
Filter bits
12
1
FB13
Filter bits
13
1
FB14
Filter bits
14
1
FB15
Filter bits
15
1
FB16
Filter bits
16
1
FB17
Filter bits
17
1
FB18
Filter bits
18
1
FB19
Filter bits
19
1
FB20
Filter bits
20
1
FB21
Filter bits
21
1
FB22
Filter bits
22
1
FB23
Filter bits
23
1
FB24
Filter bits
24
1
FB25
Filter bits
25
1
FB26
Filter bits
26
1
FB27
Filter bits
27
1
FB28
Filter bits
28
1
FB29
Filter bits
29
1
FB30
Filter bits
30
1
FB31
Filter bits
31
1
F22R2
F22R2
Filter bank 22 register 2
0x2F4
0x20
read-write
0x00000000
FB0
Filter bits
0
1
FB1
Filter bits
1
1
FB2
Filter bits
2
1
FB3
Filter bits
3
1
FB4
Filter bits
4
1
FB5
Filter bits
5
1
FB6
Filter bits
6
1
FB7
Filter bits
7
1
FB8
Filter bits
8
1
FB9
Filter bits
9
1
FB10
Filter bits
10
1
FB11
Filter bits
11
1
FB12
Filter bits
12
1
FB13
Filter bits
13
1
FB14
Filter bits
14
1
FB15
Filter bits
15
1
FB16
Filter bits
16
1
FB17
Filter bits
17
1
FB18
Filter bits
18
1
FB19
Filter bits
19
1
FB20
Filter bits
20
1
FB21
Filter bits
21
1
FB22
Filter bits
22
1
FB23
Filter bits
23
1
FB24
Filter bits
24
1
FB25
Filter bits
25
1
FB26
Filter bits
26
1
FB27
Filter bits
27
1
FB28
Filter bits
28
1
FB29
Filter bits
29
1
FB30
Filter bits
30
1
FB31
Filter bits
31
1
F23R1
F23R1
Filter bank 23 register 1
0x2F8
0x20
read-write
0x00000000
FB0
Filter bits
0
1
FB1
Filter bits
1
1
FB2
Filter bits
2
1
FB3
Filter bits
3
1
FB4
Filter bits
4
1
FB5
Filter bits
5
1
FB6
Filter bits
6
1
FB7
Filter bits
7
1
FB8
Filter bits
8
1
FB9
Filter bits
9
1
FB10
Filter bits
10
1
FB11
Filter bits
11
1
FB12
Filter bits
12
1
FB13
Filter bits
13
1
FB14
Filter bits
14
1
FB15
Filter bits
15
1
FB16
Filter bits
16
1
FB17
Filter bits
17
1
FB18
Filter bits
18
1
FB19
Filter bits
19
1
FB20
Filter bits
20
1
FB21
Filter bits
21
1
FB22
Filter bits
22
1
FB23
Filter bits
23
1
FB24
Filter bits
24
1
FB25
Filter bits
25
1
FB26
Filter bits
26
1
FB27
Filter bits
27
1
FB28
Filter bits
28
1
FB29
Filter bits
29
1
FB30
Filter bits
30
1
FB31
Filter bits
31
1
F23R2
F23R2
Filter bank 23 register 2
0x2FC
0x20
read-write
0x00000000
FB0
Filter bits
0
1
FB1
Filter bits
1
1
FB2
Filter bits
2
1
FB3
Filter bits
3
1
FB4
Filter bits
4
1
FB5
Filter bits
5
1
FB6
Filter bits
6
1
FB7
Filter bits
7
1
FB8
Filter bits
8
1
FB9
Filter bits
9
1
FB10
Filter bits
10
1
FB11
Filter bits
11
1
FB12
Filter bits
12
1
FB13
Filter bits
13
1
FB14
Filter bits
14
1
FB15
Filter bits
15
1
FB16
Filter bits
16
1
FB17
Filter bits
17
1
FB18
Filter bits
18
1
FB19
Filter bits
19
1
FB20
Filter bits
20
1
FB21
Filter bits
21
1
FB22
Filter bits
22
1
FB23
Filter bits
23
1
FB24
Filter bits
24
1
FB25
Filter bits
25
1
FB26
Filter bits
26
1
FB27
Filter bits
27
1
FB28
Filter bits
28
1
FB29
Filter bits
29
1
FB30
Filter bits
30
1
FB31
Filter bits
31
1
F24R1
F24R1
Filter bank 24 register 1
0x300
0x20
read-write
0x00000000
FB0
Filter bits
0
1
FB1
Filter bits
1
1
FB2
Filter bits
2
1
FB3
Filter bits
3
1
FB4
Filter bits
4
1
FB5
Filter bits
5
1
FB6
Filter bits
6
1
FB7
Filter bits
7
1
FB8
Filter bits
8
1
FB9
Filter bits
9
1
FB10
Filter bits
10
1
FB11
Filter bits
11
1
FB12
Filter bits
12
1
FB13
Filter bits
13
1
FB14
Filter bits
14
1
FB15
Filter bits
15
1
FB16
Filter bits
16
1
FB17
Filter bits
17
1
FB18
Filter bits
18
1
FB19
Filter bits
19
1
FB20
Filter bits
20
1
FB21
Filter bits
21
1
FB22
Filter bits
22
1
FB23
Filter bits
23
1
FB24
Filter bits
24
1
FB25
Filter bits
25
1
FB26
Filter bits
26
1
FB27
Filter bits
27
1
FB28
Filter bits
28
1
FB29
Filter bits
29
1
FB30
Filter bits
30
1
FB31
Filter bits
31
1
F24R2
F24R2
Filter bank 24 register 2
0x304
0x20
read-write
0x00000000
FB0
Filter bits
0
1
FB1
Filter bits
1
1
FB2
Filter bits
2
1
FB3
Filter bits
3
1
FB4
Filter bits
4
1
FB5
Filter bits
5
1
FB6
Filter bits
6
1
FB7
Filter bits
7
1
FB8
Filter bits
8
1
FB9
Filter bits
9
1
FB10
Filter bits
10
1
FB11
Filter bits
11
1
FB12
Filter bits
12
1
FB13
Filter bits
13
1
FB14
Filter bits
14
1
FB15
Filter bits
15
1
FB16
Filter bits
16
1
FB17
Filter bits
17
1
FB18
Filter bits
18
1
FB19
Filter bits
19
1
FB20
Filter bits
20
1
FB21
Filter bits
21
1
FB22
Filter bits
22
1
FB23
Filter bits
23
1
FB24
Filter bits
24
1
FB25
Filter bits
25
1
FB26
Filter bits
26
1
FB27
Filter bits
27
1
FB28
Filter bits
28
1
FB29
Filter bits
29
1
FB30
Filter bits
30
1
FB31
Filter bits
31
1
F25R1
F25R1
Filter bank 25 register 1
0x308
0x20
read-write
0x00000000
FB0
Filter bits
0
1
FB1
Filter bits
1
1
FB2
Filter bits
2
1
FB3
Filter bits
3
1
FB4
Filter bits
4
1
FB5
Filter bits
5
1
FB6
Filter bits
6
1
FB7
Filter bits
7
1
FB8
Filter bits
8
1
FB9
Filter bits
9
1
FB10
Filter bits
10
1
FB11
Filter bits
11
1
FB12
Filter bits
12
1
FB13
Filter bits
13
1
FB14
Filter bits
14
1
FB15
Filter bits
15
1
FB16
Filter bits
16
1
FB17
Filter bits
17
1
FB18
Filter bits
18
1
FB19
Filter bits
19
1
FB20
Filter bits
20
1
FB21
Filter bits
21
1
FB22
Filter bits
22
1
FB23
Filter bits
23
1
FB24
Filter bits
24
1
FB25
Filter bits
25
1
FB26
Filter bits
26
1
FB27
Filter bits
27
1
FB28
Filter bits
28
1
FB29
Filter bits
29
1
FB30
Filter bits
30
1
FB31
Filter bits
31
1
F25R2
F25R2
Filter bank 25 register 2
0x30C
0x20
read-write
0x00000000
FB0
Filter bits
0
1
FB1
Filter bits
1
1
FB2
Filter bits
2
1
FB3
Filter bits
3
1
FB4
Filter bits
4
1
FB5
Filter bits
5
1
FB6
Filter bits
6
1
FB7
Filter bits
7
1
FB8
Filter bits
8
1
FB9
Filter bits
9
1
FB10
Filter bits
10
1
FB11
Filter bits
11
1
FB12
Filter bits
12
1
FB13
Filter bits
13
1
FB14
Filter bits
14
1
FB15
Filter bits
15
1
FB16
Filter bits
16
1
FB17
Filter bits
17
1
FB18
Filter bits
18
1
FB19
Filter bits
19
1
FB20
Filter bits
20
1
FB21
Filter bits
21
1
FB22
Filter bits
22
1
FB23
Filter bits
23
1
FB24
Filter bits
24
1
FB25
Filter bits
25
1
FB26
Filter bits
26
1
FB27
Filter bits
27
1
FB28
Filter bits
28
1
FB29
Filter bits
29
1
FB30
Filter bits
30
1
FB31
Filter bits
31
1
F26R1
F26R1
Filter bank 26 register 1
0x310
0x20
read-write
0x00000000
FB0
Filter bits
0
1
FB1
Filter bits
1
1
FB2
Filter bits
2
1
FB3
Filter bits
3
1
FB4
Filter bits
4
1
FB5
Filter bits
5
1
FB6
Filter bits
6
1
FB7
Filter bits
7
1
FB8
Filter bits
8
1
FB9
Filter bits
9
1
FB10
Filter bits
10
1
FB11
Filter bits
11
1
FB12
Filter bits
12
1
FB13
Filter bits
13
1
FB14
Filter bits
14
1
FB15
Filter bits
15
1
FB16
Filter bits
16
1
FB17
Filter bits
17
1
FB18
Filter bits
18
1
FB19
Filter bits
19
1
FB20
Filter bits
20
1
FB21
Filter bits
21
1
FB22
Filter bits
22
1
FB23
Filter bits
23
1
FB24
Filter bits
24
1
FB25
Filter bits
25
1
FB26
Filter bits
26
1
FB27
Filter bits
27
1
FB28
Filter bits
28
1
FB29
Filter bits
29
1
FB30
Filter bits
30
1
FB31
Filter bits
31
1
F26R2
F26R2
Filter bank 26 register 2
0x314
0x20
read-write
0x00000000
FB0
Filter bits
0
1
FB1
Filter bits
1
1
FB2
Filter bits
2
1
FB3
Filter bits
3
1
FB4
Filter bits
4
1
FB5
Filter bits
5
1
FB6
Filter bits
6
1
FB7
Filter bits
7
1
FB8
Filter bits
8
1
FB9
Filter bits
9
1
FB10
Filter bits
10
1
FB11
Filter bits
11
1
FB12
Filter bits
12
1
FB13
Filter bits
13
1
FB14
Filter bits
14
1
FB15
Filter bits
15
1
FB16
Filter bits
16
1
FB17
Filter bits
17
1
FB18
Filter bits
18
1
FB19
Filter bits
19
1
FB20
Filter bits
20
1
FB21
Filter bits
21
1
FB22
Filter bits
22
1
FB23
Filter bits
23
1
FB24
Filter bits
24
1
FB25
Filter bits
25
1
FB26
Filter bits
26
1
FB27
Filter bits
27
1
FB28
Filter bits
28
1
FB29
Filter bits
29
1
FB30
Filter bits
30
1
FB31
Filter bits
31
1
F27R1
F27R1
Filter bank 27 register 1
0x318
0x20
read-write
0x00000000
FB0
Filter bits
0
1
FB1
Filter bits
1
1
FB2
Filter bits
2
1
FB3
Filter bits
3
1
FB4
Filter bits
4
1
FB5
Filter bits
5
1
FB6
Filter bits
6
1
FB7
Filter bits
7
1
FB8
Filter bits
8
1
FB9
Filter bits
9
1
FB10
Filter bits
10
1
FB11
Filter bits
11
1
FB12
Filter bits
12
1
FB13
Filter bits
13
1
FB14
Filter bits
14
1
FB15
Filter bits
15
1
FB16
Filter bits
16
1
FB17
Filter bits
17
1
FB18
Filter bits
18
1
FB19
Filter bits
19
1
FB20
Filter bits
20
1
FB21
Filter bits
21
1
FB22
Filter bits
22
1
FB23
Filter bits
23
1
FB24
Filter bits
24
1
FB25
Filter bits
25
1
FB26
Filter bits
26
1
FB27
Filter bits
27
1
FB28
Filter bits
28
1
FB29
Filter bits
29
1
FB30
Filter bits
30
1
FB31
Filter bits
31
1
F27R2
F27R2
Filter bank 27 register 2
0x31C
0x20
read-write
0x00000000
FB0
Filter bits
0
1
FB1
Filter bits
1
1
FB2
Filter bits
2
1
FB3
Filter bits
3
1
FB4
Filter bits
4
1
FB5
Filter bits
5
1
FB6
Filter bits
6
1
FB7
Filter bits
7
1
FB8
Filter bits
8
1
FB9
Filter bits
9
1
FB10
Filter bits
10
1
FB11
Filter bits
11
1
FB12
Filter bits
12
1
FB13
Filter bits
13
1
FB14
Filter bits
14
1
FB15
Filter bits
15
1
FB16
Filter bits
16
1
FB17
Filter bits
17
1
FB18
Filter bits
18
1
FB19
Filter bits
19
1
FB20
Filter bits
20
1
FB21
Filter bits
21
1
FB22
Filter bits
22
1
FB23
Filter bits
23
1
FB24
Filter bits
24
1
FB25
Filter bits
25
1
FB26
Filter bits
26
1
FB27
Filter bits
27
1
FB28
Filter bits
28
1
FB29
Filter bits
29
1
FB30
Filter bits
30
1
FB31
Filter bits
31
1
CAN2
0x40006800
CAN2_TX
CAN2 TX interrupt
86
CAN2_RX0
CAN2 RX0 interrupt
87
CAN2_RX1
CAN2 RX1 interrupt
88
CAN2_SCE
CAN SCE interrupt
89
RTC
Real-time clock
RTC
0x40002800
0x0
0x400
registers
TAMP_STAMP
Tamper and TimeStamp interrupts
2
RTC_WKUP
RTC Tamper or TimeStamp /CSS on LSE through
EXTI line 19 interrupts
3
RTC_ALARM
RTC alarms through EXTI line 18
interrupts
41
TR
TR
time register
0x0
0x20
read-write
0x00000000
PM
AM/PM notation
22
1
HT
Hour tens in BCD format
20
2
HU
Hour units in BCD format
16
4
MNT
Minute tens in BCD format
12
3
MNU
Minute units in BCD format
8
4
ST
Second tens in BCD format
4
3
SU
Second units in BCD format
0
4
DR
DR
date register
0x4
0x20
read-write
0x00002101
YT
Year tens in BCD format
20
4
YU
Year units in BCD format
16
4
WDU
Week day units
13
3
MT
Month tens in BCD format
12
1
MU
Month units in BCD format
8
4
DT
Date tens in BCD format
4
2
DU
Date units in BCD format
0
4
CR
CR
control register
0x8
0x20
read-write
0x00000000
WCKSEL
Wakeup clock selection
0
3
TSEDGE
Time-stamp event active
edge
3
1
REFCKON
Reference clock detection enable (50 or
60 Hz)
4
1
BYPSHAD
Bypass the shadow
registers
5
1
FMT
Hour format
6
1
ALRAE
Alarm A enable
8
1
ALRBE
Alarm B enable
9
1
WUTE
Wakeup timer enable
10
1
TSE
Time stamp enable
11
1
ALRAIE
Alarm A interrupt enable
12
1
ALRBIE
Alarm B interrupt enable
13
1
WUTIE
Wakeup timer interrupt
enable
14
1
TSIE
Time-stamp interrupt
enable
15
1
ADD1H
Add 1 hour (summer time
change)
16
1
SUB1H
Subtract 1 hour (winter time
change)
17
1
BKP
Backup
18
1
COSEL
Calibration output
selection
19
1
POL
Output polarity
20
1
OSEL
Output selection
21
2
COE
Calibration output enable
23
1
ITSE
timestamp on internal event
enable
24
1
ISR
ISR
initialization and status
register
0xC
0x20
0x00000007
ALRAWF
Alarm A write flag
0
1
read-only
ALRBWF
Alarm B write flag
1
1
read-only
WUTWF
Wakeup timer write flag
2
1
read-only
SHPF
Shift operation pending
3
1
read-write
INITS
Initialization status flag
4
1
read-only
RSF
Registers synchronization
flag
5
1
read-write
INITF
Initialization flag
6
1
read-only
INIT
Initialization mode
7
1
read-write
ALRAF
Alarm A flag
8
1
read-write
ALRBF
Alarm B flag
9
1
read-write
WUTF
Wakeup timer flag
10
1
read-write
TSF
Time-stamp flag
11
1
read-write
TSOVF
Time-stamp overflow flag
12
1
read-write
TAMP1F
Tamper detection flag
13
1
read-write
TAMP2F
RTC_TAMP2 detection flag
14
1
read-write
TAMP3F
RTC_TAMP3 detection flag
15
1
read-write
RECALPF
Recalibration pending Flag
16
1
read-only
PRER
PRER
prescaler register
0x10
0x20
read-write
0x007F00FF
PREDIV_A
Asynchronous prescaler
factor
16
7
PREDIV_S
Synchronous prescaler
factor
0
15
WUTR
WUTR
wakeup timer register
0x14
0x20
read-write
0x0000FFFF
WUT
Wakeup auto-reload value
bits
0
16
ALRMAR
ALRMAR
alarm A register
0x1C
0x20
read-write
0x00000000
MSK4
Alarm A date mask
31
1
WDSEL
Week day selection
30
1
DT
Date tens in BCD format
28
2
DU
Date units or day in BCD
format
24
4
MSK3
Alarm A hours mask
23
1
PM
AM/PM notation
22
1
HT
Hour tens in BCD format
20
2
HU
Hour units in BCD format
16
4
MSK2
Alarm A minutes mask
15
1
MNT
Minute tens in BCD format
12
3
MNU
Minute units in BCD format
8
4
MSK1
Alarm A seconds mask
7
1
ST
Second tens in BCD format
4
3
SU
Second units in BCD format
0
4
ALRMBR
ALRMBR
alarm B register
0x20
0x20
read-write
0x00000000
MSK4
Alarm B date mask
31
1
WDSEL
Week day selection
30
1
DT
Date tens in BCD format
28
2
DU
Date units or day in BCD
format
24
4
MSK3
Alarm B hours mask
23
1
PM
AM/PM notation
22
1
HT
Hour tens in BCD format
20
2
HU
Hour units in BCD format
16
4
MSK2
Alarm B minutes mask
15
1
MNT
Minute tens in BCD format
12
3
MNU
Minute units in BCD format
8
4
MSK1
Alarm B seconds mask
7
1
ST
Second tens in BCD format
4
3
SU
Second units in BCD format
0
4
WPR
WPR
write protection register
0x24
0x20
write-only
0x00000000
KEY
Write protection key
0
8
SSR
SSR
sub second register
0x28
0x20
read-only
0x00000000
SS
Sub second value
0
16
SHIFTR
SHIFTR
shift control register
0x2C
0x20
write-only
0x00000000
ADD1S
Add one second
31
1
SUBFS
Subtract a fraction of a
second
0
15
TSTR
TSTR
time stamp time register
0x30
0x20
read-only
0x00000000
SU
Second units in BCD format
0
4
ST
Second tens in BCD format
4
3
MNU
Minute units in BCD format
8
4
MNT
Minute tens in BCD format
12
3
HU
Hour units in BCD format
16
4
HT
Hour tens in BCD format
20
2
PM
AM/PM notation
22
1
TSDR
TSDR
time stamp date register
0x34
0x20
read-only
0x00000000
WDU
Week day units
13
3
MT
Month tens in BCD format
12
1
MU
Month units in BCD format
8
4
DT
Date tens in BCD format
4
2
DU
Date units in BCD format
0
4
TSSSR
TSSSR
timestamp sub second register
0x38
0x20
read-only
0x00000000
SS
Sub second value
0
16
CALR
CALR
calibration register
0x3C
0x20
read-write
0x00000000
CALP
Increase frequency of RTC by 488.5
ppm
15
1
CALW8
Use an 8-second calibration cycle
period
14
1
CALW16
Use a 16-second calibration cycle
period
13
1
CALM
Calibration minus
0
9
TAMPCR
TAMPCR
tamper configuration register
0x40
0x20
read-write
0x00000000
TAMP1E
Tamper 1 detection enable
0
1
TAMP1TRG
Active level for tamper 1
1
1
TAMPIE
Tamper interrupt enable
2
1
TAMP2E
Tamper 2 detection enable
3
1
TAMP2TRG
Active level for tamper 2
4
1
TAMP3E
Tamper 3 detection enable
5
1
TAMP3TRG
Active level for tamper 3
6
1
TAMPTS
Activate timestamp on tamper detection
event
7
1
TAMPFREQ
Tamper sampling frequency
8
3
TAMPFLT
Tamper filter count
11
2
TAMPPRCH
Tamper precharge duration
13
2
TAMPPUDIS
TAMPER pull-up disable
15
1
TAMP1IE
Tamper 1 interrupt enable
16
1
TAMP1NOERASE
Tamper 1 no erase
17
1
TAMP1MF
Tamper 1 mask flag
18
1
TAMP2IE
Tamper 2 interrupt enable
19
1
TAMP2NOERASE
Tamper 2 no erase
20
1
TAMP2MF
Tamper 2 mask flag
21
1
TAMP3IE
Tamper 3 interrupt enable
22
1
TAMP3NOERASE
Tamper 3 no erase
23
1
TAMP3MF
Tamper 3 mask flag
24
1
ALRMASSR
ALRMASSR
alarm A sub second register
0x44
0x20
read-write
0x00000000
MASKSS
Mask the most-significant bits starting
at this bit
24
4
SS
Sub seconds value
0
15
ALRMBSSR
ALRMBSSR
alarm B sub second register
0x48
0x20
read-write
0x00000000
MASKSS
Mask the most-significant bits starting
at this bit
24
4
SS
Sub seconds value
0
15
OR
OR
option register
0x4C
0x20
read-write
0x00000000
RTC_ALARM_TYPE
RTC_ALARM on PC13 output
type
0
1
RTC_OUT_RMP
RTC_OUT remap
1
1
BKP0R
BKP0R
backup register
0x50
0x20
read-write
0x00000000
BKP
BKP
0
32
BKP1R
BKP1R
backup register
0x54
0x20
read-write
0x00000000
BKP
BKP
0
32
BKP2R
BKP2R
backup register
0x58
0x20
read-write
0x00000000
BKP
BKP
0
32
BKP3R
BKP3R
backup register
0x5C
0x20
read-write
0x00000000
BKP
BKP
0
32
BKP4R
BKP4R
backup register
0x60
0x20
read-write
0x00000000
BKP
BKP
0
32
BKP5R
BKP5R
backup register
0x64
0x20
read-write
0x00000000
BKP
BKP
0
32
BKP6R
BKP6R
backup register
0x68
0x20
read-write
0x00000000
BKP
BKP
0
32
BKP7R
BKP7R
backup register
0x6C
0x20
read-write
0x00000000
BKP
BKP
0
32
BKP8R
BKP8R
backup register
0x70
0x20
read-write
0x00000000
BKP
BKP
0
32
BKP9R
BKP9R
backup register
0x74
0x20
read-write
0x00000000
BKP
BKP
0
32
BKP10R
BKP10R
backup register
0x78
0x20
read-write
0x00000000
BKP
BKP
0
32
BKP11R
BKP11R
backup register
0x7C
0x20
read-write
0x00000000
BKP
BKP
0
32
BKP12R
BKP12R
backup register
0x80
0x20
read-write
0x00000000
BKP
BKP
0
32
BKP13R
BKP13R
backup register
0x84
0x20
read-write
0x00000000
BKP
BKP
0
32
BKP14R
BKP14R
backup register
0x88
0x20
read-write
0x00000000
BKP
BKP
0
32
BKP15R
BKP15R
backup register
0x8C
0x20
read-write
0x00000000
BKP
BKP
0
32
BKP16R
BKP16R
backup register
0x90
0x20
read-write
0x00000000
BKP
BKP
0
32
BKP17R
BKP17R
backup register
0x94
0x20
read-write
0x00000000
BKP
BKP
0
32
BKP18R
BKP18R
backup register
0x98
0x20
read-write
0x00000000
BKP
BKP
0
32
BKP19R
BKP19R
backup register
0x9C
0x20
read-write
0x00000000
BKP
BKP
0
32
BKP20R
BKP20R
backup register
0xA0
0x20
read-write
0x00000000
BKP
BKP
0
32
BKP21R
BKP21R
backup register
0xA4
0x20
read-write
0x00000000
BKP
BKP
0
32
BKP22R
BKP22R
backup register
0xA8
0x20
read-write
0x00000000
BKP
BKP
0
32
BKP23R
BKP23R
backup register
0xAC
0x20
read-write
0x00000000
BKP
BKP
0
32
BKP24R
BKP24R
backup register
0xB0
0x20
read-write
0x00000000
BKP
BKP
0
32
BKP25R
BKP25R
backup register
0xB4
0x20
read-write
0x00000000
BKP
BKP
0
32
BKP26R
BKP26R
backup register
0xB8
0x20
read-write
0x00000000
BKP
BKP
0
32
BKP27R
BKP27R
backup register
0xBC
0x20
read-write
0x00000000
BKP
BKP
0
32
BKP28R
BKP28R
backup register
0xC0
0x20
read-write
0x00000000
BKP
BKP
0
32
BKP29R
BKP29R
backup register
0xC4
0x20
read-write
0x00000000
BKP
BKP
0
32
BKP30R
BKP30R
backup register
0xC8
0x20
read-write
0x00000000
BKP
BKP
0
32
BKP31R
BKP31R
backup register
0xCC
0x20
read-write
0x00000000
BKP
BKP
0
32
OTG_FS_GLOBAL
USB on the go full speed
USB_OTG_FS
0x50000000
0x0
0x400
registers
OTG_FS
USB OTG FS global Interrupt
67
FS_GOTGCTL
FS_GOTGCTL
OTG_FS control and status register
(OTG_FS_GOTGCTL)
0x0
0x20
0x00000800
SRQSCS
Session request success
0
1
read-only
SRQ
Session request
1
1
read-write
HNGSCS
Host negotiation success
8
1
read-only
HNPRQ
HNP request
9
1
read-write
HSHNPEN
Host set HNP enable
10
1
read-write
DHNPEN
Device HNP enabled
11
1
read-write
CIDSTS
Connector ID status
16
1
read-only
DBCT
Long/short debounce time
17
1
read-only
ASVLD
A-session valid
18
1
read-only
BSVLD
B-session valid
19
1
read-only
FS_GOTGINT
FS_GOTGINT
OTG_FS interrupt register
(OTG_FS_GOTGINT)
0x4
0x20
read-write
0x00000000
SEDET
Session end detected
2
1
SRSSCHG
Session request success status
change
8
1
HNSSCHG
Host negotiation success status
change
9
1
HNGDET
Host negotiation detected
17
1
ADTOCHG
A-device timeout change
18
1
DBCDNE
Debounce done
19
1
FS_GAHBCFG
FS_GAHBCFG
OTG_FS AHB configuration register
(OTG_FS_GAHBCFG)
0x8
0x20
read-write
0x00000000
GINT
Global interrupt mask
0
1
TXFELVL
TxFIFO empty level
7
1
PTXFELVL
Periodic TxFIFO empty
level
8
1
FS_GUSBCFG
FS_GUSBCFG
OTG_FS USB configuration register
(OTG_FS_GUSBCFG)
0xC
0x20
0x00000A00
TOCAL
FS timeout calibration
0
3
read-write
PHYSEL
Full Speed serial transceiver
select
6
1
write-only
SRPCAP
SRP-capable
8
1
read-write
HNPCAP
HNP-capable
9
1
read-write
TRDT
USB turnaround time
10
4
read-write
FHMOD
Force host mode
29
1
read-write
FDMOD
Force device mode
30
1
read-write
CTXPKT
Corrupt Tx packet
31
1
read-write
FS_GRSTCTL
FS_GRSTCTL
OTG_FS reset register
(OTG_FS_GRSTCTL)
0x10
0x20
0x20000000
CSRST
Core soft reset
0
1
read-write
HSRST
HCLK soft reset
1
1
read-write
FCRST
Host frame counter reset
2
1
read-write
RXFFLSH
RxFIFO flush
4
1
read-write
TXFFLSH
TxFIFO flush
5
1
read-write
TXFNUM
TxFIFO number
6
5
read-write
AHBIDL
AHB master idle
31
1
read-only
FS_GINTSTS
FS_GINTSTS
OTG_FS core interrupt register
(OTG_FS_GINTSTS)
0x14
0x20
0x04000020
CMOD
Current mode of operation
0
1
read-only
MMIS
Mode mismatch interrupt
1
1
read-write
OTGINT
OTG interrupt
2
1
read-only
SOF
Start of frame
3
1
read-write
RXFLVL
RxFIFO non-empty
4
1
read-only
NPTXFE
Non-periodic TxFIFO empty
5
1
read-only
GINAKEFF
Global IN non-periodic NAK
effective
6
1
read-only
GOUTNAKEFF
Global OUT NAK effective
7
1
read-only
ESUSP
Early suspend
10
1
read-write
USBSUSP
USB suspend
11
1
read-write
USBRST
USB reset
12
1
read-write
ENUMDNE
Enumeration done
13
1
read-write
ISOODRP
Isochronous OUT packet dropped
interrupt
14
1
read-write
EOPF
End of periodic frame
interrupt
15
1
read-write
IEPINT
IN endpoint interrupt
18
1
read-only
OEPINT
OUT endpoint interrupt
19
1
read-only
IISOIXFR
Incomplete isochronous IN
transfer
20
1
read-write
IPXFR_INCOMPISOOUT
Incomplete periodic transfer(Host
mode)/Incomplete isochronous OUT transfer(Device
mode)
21
1
read-write
HPRTINT
Host port interrupt
24
1
read-only
HCINT
Host channels interrupt
25
1
read-only
PTXFE
Periodic TxFIFO empty
26
1
read-only
CIDSCHG
Connector ID status change
28
1
read-write
DISCINT
Disconnect detected
interrupt
29
1
read-write
SRQINT
Session request/new session detected
interrupt
30
1
read-write
WKUPINT
Resume/remote wakeup detected
interrupt
31
1
read-write
FS_GINTMSK
FS_GINTMSK
OTG_FS interrupt mask register
(OTG_FS_GINTMSK)
0x18
0x20
0x00000000
MMISM
Mode mismatch interrupt
mask
1
1
read-write
OTGINT
OTG interrupt mask
2
1
read-write
SOFM
Start of frame mask
3
1
read-write
RXFLVLM
Receive FIFO non-empty
mask
4
1
read-write
NPTXFEM
Non-periodic TxFIFO empty
mask
5
1
read-write
GINAKEFFM
Global non-periodic IN NAK effective
mask
6
1
read-write
GONAKEFFM
Global OUT NAK effective
mask
7
1
read-write
ESUSPM
Early suspend mask
10
1
read-write
USBSUSPM
USB suspend mask
11
1
read-write
USBRST
USB reset mask
12
1
read-write
ENUMDNEM
Enumeration done mask
13
1
read-write
ISOODRPM
Isochronous OUT packet dropped interrupt
mask
14
1
read-write
EOPFM
End of periodic frame interrupt
mask
15
1
read-write
EPMISM
Endpoint mismatch interrupt
mask
17
1
read-write
IEPINT
IN endpoints interrupt
mask
18
1
read-write
OEPINT
OUT endpoints interrupt
mask
19
1
read-write
IISOIXFRM
Incomplete isochronous IN transfer
mask
20
1
read-write
IPXFRM_IISOOXFRM
Incomplete periodic transfer mask(Host
mode)/Incomplete isochronous OUT transfer mask(Device
mode)
21
1
read-write
PRTIM
Host port interrupt mask
24
1
read-only
HCIM
Host channels interrupt
mask
25
1
read-write
PTXFEM
Periodic TxFIFO empty mask
26
1
read-write
CIDSCHGM
Connector ID status change
mask
28
1
read-write
DISCINT
Disconnect detected interrupt
mask
29
1
read-write
SRQIM
Session request/new session detected
interrupt mask
30
1
read-write
WUIM
Resume/remote wakeup detected interrupt
mask
31
1
read-write
FS_GRXSTSR_Device
FS_GRXSTSR_Device
OTG_FS Receive status debug read(Device
mode)
0x1C
0x20
read-only
0x00000000
EPNUM
Endpoint number
0
4
BCNT
Byte count
4
11
DPID
Data PID
15
2
PKTSTS
Packet status
17
4
FRMNUM
Frame number
21
4
FS_GRXSTSR_Host
FS_GRXSTSR_Host
OTG_FS Receive status debug read(Host
mode)
FS_GRXSTSR_Device
0x1C
0x20
read-only
0x00000000
EPNUM
Endpoint number
0
4
BCNT
Byte count
4
11
DPID
Data PID
15
2
PKTSTS
Packet status
17
4
FRMNUM
Frame number
21
4
FS_GRXFSIZ
FS_GRXFSIZ
OTG_FS Receive FIFO size register
(OTG_FS_GRXFSIZ)
0x24
0x20
read-write
0x00000200
RXFD
RxFIFO depth
0
16
FS_GNPTXFSIZ_Device
FS_GNPTXFSIZ_Device
OTG_FS non-periodic transmit FIFO size
register (Device mode)
0x28
0x20
read-write
0x00000200
TX0FSA
Endpoint 0 transmit RAM start
address
0
16
TX0FD
Endpoint 0 TxFIFO depth
16
16
FS_GNPTXFSIZ_Host
FS_GNPTXFSIZ_Host
OTG_FS non-periodic transmit FIFO size
register (Host mode)
FS_GNPTXFSIZ_Device
0x28
0x20
read-write
0x00000200
NPTXFSA
Non-periodic transmit RAM start
address
0
16
NPTXFD
Non-periodic TxFIFO depth
16
16
FS_GNPTXSTS
FS_GNPTXSTS
OTG_FS non-periodic transmit FIFO/queue
status register (OTG_FS_GNPTXSTS)
0x2C
0x20
read-only
0x00080200
NPTXFSAV
Non-periodic TxFIFO space
available
0
16
NPTQXSAV
Non-periodic transmit request queue
space available
16
8
NPTXQTOP
Top of the non-periodic transmit request
queue
24
7
FS_GCCFG
FS_GCCFG
OTG_FS general core configuration register
(OTG_FS_GCCFG)
0x38
0x20
read-write
0x00000000
PWRDWN
Power down
16
1
VBUSASEN
Enable the VBUS sensing
device
18
1
VBUSBSEN
Enable the VBUS sensing
device
19
1
SOFOUTEN
SOF output enable
20
1
FS_CID
FS_CID
core ID register
0x3C
0x20
read-write
0x00001000
PRODUCT_ID
Product ID field
0
32
FS_HPTXFSIZ
FS_HPTXFSIZ
OTG_FS Host periodic transmit FIFO size
register (OTG_FS_HPTXFSIZ)
0x100
0x20
read-write
0x02000600
PTXSA
Host periodic TxFIFO start
address
0
16
PTXFSIZ
Host periodic TxFIFO depth
16
16
FS_DIEPTXF1
FS_DIEPTXF1
OTG_FS device IN endpoint transmit FIFO size
register (OTG_FS_DIEPTXF2)
0x104
0x20
read-write
0x02000400
INEPTXSA
IN endpoint FIFO2 transmit RAM start
address
0
16
INEPTXFD
IN endpoint TxFIFO depth
16
16
FS_DIEPTXF2
FS_DIEPTXF2
OTG_FS device IN endpoint transmit FIFO size
register (OTG_FS_DIEPTXF3)
0x108
0x20
read-write
0x02000400
INEPTXSA
IN endpoint FIFO3 transmit RAM start
address
0
16
INEPTXFD
IN endpoint TxFIFO depth
16
16
FS_DIEPTXF3
FS_DIEPTXF3
OTG_FS device IN endpoint transmit FIFO size
register (OTG_FS_DIEPTXF4)
0x10C
0x20
read-write
0x02000400
INEPTXSA
IN endpoint FIFO4 transmit RAM start
address
0
16
INEPTXFD
IN endpoint TxFIFO depth
16
16
OTG_FS_HOST
USB on the go full speed
USB_OTG_FS
0x50000400
0x0
0x400
registers
FS_HCFG
FS_HCFG
OTG_FS host configuration register
(OTG_FS_HCFG)
0x0
0x20
0x00000000
FSLSPCS
FS/LS PHY clock select
0
2
read-write
FSLSS
FS- and LS-only support
2
1
read-only
HFIR
HFIR
OTG_FS Host frame interval
register
0x4
0x20
read-write
0x0000EA60
FRIVL
Frame interval
0
16
FS_HFNUM
FS_HFNUM
OTG_FS host frame number/frame time
remaining register (OTG_FS_HFNUM)
0x8
0x20
read-only
0x00003FFF
FRNUM
Frame number
0
16
FTREM
Frame time remaining
16
16
FS_HPTXSTS
FS_HPTXSTS
OTG_FS_Host periodic transmit FIFO/queue
status register (OTG_FS_HPTXSTS)
0x10
0x20
0x00080100
PTXFSAVL
Periodic transmit data FIFO space
available
0
16
read-write
PTXQSAV
Periodic transmit request queue space
available
16
8
read-only
PTXQTOP
Top of the periodic transmit request
queue
24
8
read-only
HAINT
HAINT
OTG_FS Host all channels interrupt
register
0x14
0x20
read-only
0x00000000
HAINT
Channel interrupts
0
16
HAINTMSK
HAINTMSK
OTG_FS host all channels interrupt mask
register
0x18
0x20
read-write
0x00000000
HAINTM
Channel interrupt mask
0
16
FS_HPRT
FS_HPRT
OTG_FS host port control and status register
(OTG_FS_HPRT)
0x40
0x20
0x00000000
PCSTS
Port connect status
0
1
read-only
PCDET
Port connect detected
1
1
read-write
PENA
Port enable
2
1
read-write
PENCHNG
Port enable/disable change
3
1
read-write
POCA
Port overcurrent active
4
1
read-only
POCCHNG
Port overcurrent change
5
1
read-write
PRES
Port resume
6
1
read-write
PSUSP
Port suspend
7
1
read-write
PRST
Port reset
8
1
read-write
PLSTS
Port line status
10
2
read-only
PPWR
Port power
12
1
read-write
PTCTL
Port test control
13
4
read-write
PSPD
Port speed
17
2
read-only
FS_HCCHAR0
FS_HCCHAR0
OTG_FS host channel-0 characteristics
register (OTG_FS_HCCHAR0)
0x100
0x20
read-write
0x00000000
MPSIZ
Maximum packet size
0
11
EPNUM
Endpoint number
11
4
EPDIR
Endpoint direction
15
1
LSDEV
Low-speed device
17
1
EPTYP
Endpoint type
18
2
MCNT
Multicount
20
2
DAD
Device address
22
7
ODDFRM
Odd frame
29
1
CHDIS
Channel disable
30
1
CHENA
Channel enable
31
1
FS_HCCHAR1
FS_HCCHAR1
OTG_FS host channel-1 characteristics
register (OTG_FS_HCCHAR1)
0x120
0x20
read-write
0x00000000
MPSIZ
Maximum packet size
0
11
EPNUM
Endpoint number
11
4
EPDIR
Endpoint direction
15
1
LSDEV
Low-speed device
17
1
EPTYP
Endpoint type
18
2
MCNT
Multicount
20
2
DAD
Device address
22
7
ODDFRM
Odd frame
29
1
CHDIS
Channel disable
30
1
CHENA
Channel enable
31
1
FS_HCCHAR2
FS_HCCHAR2
OTG_FS host channel-2 characteristics
register (OTG_FS_HCCHAR2)
0x140
0x20
read-write
0x00000000
MPSIZ
Maximum packet size
0
11
EPNUM
Endpoint number
11
4
EPDIR
Endpoint direction
15
1
LSDEV
Low-speed device
17
1
EPTYP
Endpoint type
18
2
MCNT
Multicount
20
2
DAD
Device address
22
7
ODDFRM
Odd frame
29
1
CHDIS
Channel disable
30
1
CHENA
Channel enable
31
1
FS_HCCHAR3
FS_HCCHAR3
OTG_FS host channel-3 characteristics
register (OTG_FS_HCCHAR3)
0x160
0x20
read-write
0x00000000
MPSIZ
Maximum packet size
0
11
EPNUM
Endpoint number
11
4
EPDIR
Endpoint direction
15
1
LSDEV
Low-speed device
17
1
EPTYP
Endpoint type
18
2
MCNT
Multicount
20
2
DAD
Device address
22
7
ODDFRM
Odd frame
29
1
CHDIS
Channel disable
30
1
CHENA
Channel enable
31
1
FS_HCCHAR4
FS_HCCHAR4
OTG_FS host channel-4 characteristics
register (OTG_FS_HCCHAR4)
0x180
0x20
read-write
0x00000000
MPSIZ
Maximum packet size
0
11
EPNUM
Endpoint number
11
4
EPDIR
Endpoint direction
15
1
LSDEV
Low-speed device
17
1
EPTYP
Endpoint type
18
2
MCNT
Multicount
20
2
DAD
Device address
22
7
ODDFRM
Odd frame
29
1
CHDIS
Channel disable
30
1
CHENA
Channel enable
31
1
FS_HCCHAR5
FS_HCCHAR5
OTG_FS host channel-5 characteristics
register (OTG_FS_HCCHAR5)
0x1A0
0x20
read-write
0x00000000
MPSIZ
Maximum packet size
0
11
EPNUM
Endpoint number
11
4
EPDIR
Endpoint direction
15
1
LSDEV
Low-speed device
17
1
EPTYP
Endpoint type
18
2
MCNT
Multicount
20
2
DAD
Device address
22
7
ODDFRM
Odd frame
29
1
CHDIS
Channel disable
30
1
CHENA
Channel enable
31
1
FS_HCCHAR6
FS_HCCHAR6
OTG_FS host channel-6 characteristics
register (OTG_FS_HCCHAR6)
0x1C0
0x20
read-write
0x00000000
MPSIZ
Maximum packet size
0
11
EPNUM
Endpoint number
11
4
EPDIR
Endpoint direction
15
1
LSDEV
Low-speed device
17
1
EPTYP
Endpoint type
18
2
MCNT
Multicount
20
2
DAD
Device address
22
7
ODDFRM
Odd frame
29
1
CHDIS
Channel disable
30
1
CHENA
Channel enable
31
1
FS_HCCHAR7
FS_HCCHAR7
OTG_FS host channel-7 characteristics
register (OTG_FS_HCCHAR7)
0x1E0
0x20
read-write
0x00000000
MPSIZ
Maximum packet size
0
11
EPNUM
Endpoint number
11
4
EPDIR
Endpoint direction
15
1
LSDEV
Low-speed device
17
1
EPTYP
Endpoint type
18
2
MCNT
Multicount
20
2
DAD
Device address
22
7
ODDFRM
Odd frame
29
1
CHDIS
Channel disable
30
1
CHENA
Channel enable
31
1
FS_HCINT0
FS_HCINT0
OTG_FS host channel-0 interrupt register
(OTG_FS_HCINT0)
0x108
0x20
read-write
0x00000000
XFRC
Transfer completed
0
1
CHH
Channel halted
1
1
STALL
STALL response received
interrupt
3
1
NAK
NAK response received
interrupt
4
1
ACK
ACK response received/transmitted
interrupt
5
1
TXERR
Transaction error
7
1
BBERR
Babble error
8
1
FRMOR
Frame overrun
9
1
DTERR
Data toggle error
10
1
FS_HCINT1
FS_HCINT1
OTG_FS host channel-1 interrupt register
(OTG_FS_HCINT1)
0x128
0x20
read-write
0x00000000
XFRC
Transfer completed
0
1
CHH
Channel halted
1
1
STALL
STALL response received
interrupt
3
1
NAK
NAK response received
interrupt
4
1
ACK
ACK response received/transmitted
interrupt
5
1
TXERR
Transaction error
7
1
BBERR
Babble error
8
1
FRMOR
Frame overrun
9
1
DTERR
Data toggle error
10
1
FS_HCINT2
FS_HCINT2
OTG_FS host channel-2 interrupt register
(OTG_FS_HCINT2)
0x148
0x20
read-write
0x00000000
XFRC
Transfer completed
0
1
CHH
Channel halted
1
1
STALL
STALL response received
interrupt
3
1
NAK
NAK response received
interrupt
4
1
ACK
ACK response received/transmitted
interrupt
5
1
TXERR
Transaction error
7
1
BBERR
Babble error
8
1
FRMOR
Frame overrun
9
1
DTERR
Data toggle error
10
1
FS_HCINT3
FS_HCINT3
OTG_FS host channel-3 interrupt register
(OTG_FS_HCINT3)
0x168
0x20
read-write
0x00000000
XFRC
Transfer completed
0
1
CHH
Channel halted
1
1
STALL
STALL response received
interrupt
3
1
NAK
NAK response received
interrupt
4
1
ACK
ACK response received/transmitted
interrupt
5
1
TXERR
Transaction error
7
1
BBERR
Babble error
8
1
FRMOR
Frame overrun
9
1
DTERR
Data toggle error
10
1
FS_HCINT4
FS_HCINT4
OTG_FS host channel-4 interrupt register
(OTG_FS_HCINT4)
0x188
0x20
read-write
0x00000000
XFRC
Transfer completed
0
1
CHH
Channel halted
1
1
STALL
STALL response received
interrupt
3
1
NAK
NAK response received
interrupt
4
1
ACK
ACK response received/transmitted
interrupt
5
1
TXERR
Transaction error
7
1
BBERR
Babble error
8
1
FRMOR
Frame overrun
9
1
DTERR
Data toggle error
10
1
FS_HCINT5
FS_HCINT5
OTG_FS host channel-5 interrupt register
(OTG_FS_HCINT5)
0x1A8
0x20
read-write
0x00000000
XFRC
Transfer completed
0
1
CHH
Channel halted
1
1
STALL
STALL response received
interrupt
3
1
NAK
NAK response received
interrupt
4
1
ACK
ACK response received/transmitted
interrupt
5
1
TXERR
Transaction error
7
1
BBERR
Babble error
8
1
FRMOR
Frame overrun
9
1
DTERR
Data toggle error
10
1
FS_HCINT6
FS_HCINT6
OTG_FS host channel-6 interrupt register
(OTG_FS_HCINT6)
0x1C8
0x20
read-write
0x00000000
XFRC
Transfer completed
0
1
CHH
Channel halted
1
1
STALL
STALL response received
interrupt
3
1
NAK
NAK response received
interrupt
4
1
ACK
ACK response received/transmitted
interrupt
5
1
TXERR
Transaction error
7
1
BBERR
Babble error
8
1
FRMOR
Frame overrun
9
1
DTERR
Data toggle error
10
1
FS_HCINT7
FS_HCINT7
OTG_FS host channel-7 interrupt register
(OTG_FS_HCINT7)
0x1E8
0x20
read-write
0x00000000
XFRC
Transfer completed
0
1
CHH
Channel halted
1
1
STALL
STALL response received
interrupt
3
1
NAK
NAK response received
interrupt
4
1
ACK
ACK response received/transmitted
interrupt
5
1
TXERR
Transaction error
7
1
BBERR
Babble error
8
1
FRMOR
Frame overrun
9
1
DTERR
Data toggle error
10
1
FS_HCINTMSK0
FS_HCINTMSK0
OTG_FS host channel-0 mask register
(OTG_FS_HCINTMSK0)
0x10C
0x20
read-write
0x00000000
XFRCM
Transfer completed mask
0
1
CHHM
Channel halted mask
1
1
STALLM
STALL response received interrupt
mask
3
1
NAKM
NAK response received interrupt
mask
4
1
ACKM
ACK response received/transmitted
interrupt mask
5
1
NYET
response received interrupt
mask
6
1
TXERRM
Transaction error mask
7
1
BBERRM
Babble error mask
8
1
FRMORM
Frame overrun mask
9
1
DTERRM
Data toggle error mask
10
1
FS_HCINTMSK1
FS_HCINTMSK1
OTG_FS host channel-1 mask register
(OTG_FS_HCINTMSK1)
0x12C
0x20
read-write
0x00000000
XFRCM
Transfer completed mask
0
1
CHHM
Channel halted mask
1
1
STALLM
STALL response received interrupt
mask
3
1
NAKM
NAK response received interrupt
mask
4
1
ACKM
ACK response received/transmitted
interrupt mask
5
1
NYET
response received interrupt
mask
6
1
TXERRM
Transaction error mask
7
1
BBERRM
Babble error mask
8
1
FRMORM
Frame overrun mask
9
1
DTERRM
Data toggle error mask
10
1
FS_HCINTMSK2
FS_HCINTMSK2
OTG_FS host channel-2 mask register
(OTG_FS_HCINTMSK2)
0x14C
0x20
read-write
0x00000000
XFRCM
Transfer completed mask
0
1
CHHM
Channel halted mask
1
1
STALLM
STALL response received interrupt
mask
3
1
NAKM
NAK response received interrupt
mask
4
1
ACKM
ACK response received/transmitted
interrupt mask
5
1
NYET
response received interrupt
mask
6
1
TXERRM
Transaction error mask
7
1
BBERRM
Babble error mask
8
1
FRMORM
Frame overrun mask
9
1
DTERRM
Data toggle error mask
10
1
FS_HCINTMSK3
FS_HCINTMSK3
OTG_FS host channel-3 mask register
(OTG_FS_HCINTMSK3)
0x16C
0x20
read-write
0x00000000
XFRCM
Transfer completed mask
0
1
CHHM
Channel halted mask
1
1
STALLM
STALL response received interrupt
mask
3
1
NAKM
NAK response received interrupt
mask
4
1
ACKM
ACK response received/transmitted
interrupt mask
5
1
NYET
response received interrupt
mask
6
1
TXERRM
Transaction error mask
7
1
BBERRM
Babble error mask
8
1
FRMORM
Frame overrun mask
9
1
DTERRM
Data toggle error mask
10
1
FS_HCINTMSK4
FS_HCINTMSK4
OTG_FS host channel-4 mask register
(OTG_FS_HCINTMSK4)
0x18C
0x20
read-write
0x00000000
XFRCM
Transfer completed mask
0
1
CHHM
Channel halted mask
1
1
STALLM
STALL response received interrupt
mask
3
1
NAKM
NAK response received interrupt
mask
4
1
ACKM
ACK response received/transmitted
interrupt mask
5
1
NYET
response received interrupt
mask
6
1
TXERRM
Transaction error mask
7
1
BBERRM
Babble error mask
8
1
FRMORM
Frame overrun mask
9
1
DTERRM
Data toggle error mask
10
1
FS_HCINTMSK5
FS_HCINTMSK5
OTG_FS host channel-5 mask register
(OTG_FS_HCINTMSK5)
0x1AC
0x20
read-write
0x00000000
XFRCM
Transfer completed mask
0
1
CHHM
Channel halted mask
1
1
STALLM
STALL response received interrupt
mask
3
1
NAKM
NAK response received interrupt
mask
4
1
ACKM
ACK response received/transmitted
interrupt mask
5
1
NYET
response received interrupt
mask
6
1
TXERRM
Transaction error mask
7
1
BBERRM
Babble error mask
8
1
FRMORM
Frame overrun mask
9
1
DTERRM
Data toggle error mask
10
1
FS_HCINTMSK6
FS_HCINTMSK6
OTG_FS host channel-6 mask register
(OTG_FS_HCINTMSK6)
0x1CC
0x20
read-write
0x00000000
XFRCM
Transfer completed mask
0
1
CHHM
Channel halted mask
1
1
STALLM
STALL response received interrupt
mask
3
1
NAKM
NAK response received interrupt
mask
4
1
ACKM
ACK response received/transmitted
interrupt mask
5
1
NYET
response received interrupt
mask
6
1
TXERRM
Transaction error mask
7
1
BBERRM
Babble error mask
8
1
FRMORM
Frame overrun mask
9
1
DTERRM
Data toggle error mask
10
1
FS_HCINTMSK7
FS_HCINTMSK7
OTG_FS host channel-7 mask register
(OTG_FS_HCINTMSK7)
0x1EC
0x20
read-write
0x00000000
XFRCM
Transfer completed mask
0
1
CHHM
Channel halted mask
1
1
STALLM
STALL response received interrupt
mask
3
1
NAKM
NAK response received interrupt
mask
4
1
ACKM
ACK response received/transmitted
interrupt mask
5
1
NYET
response received interrupt
mask
6
1
TXERRM
Transaction error mask
7
1
BBERRM
Babble error mask
8
1
FRMORM
Frame overrun mask
9
1
DTERRM
Data toggle error mask
10
1
FS_HCTSIZ0
FS_HCTSIZ0
OTG_FS host channel-0 transfer size
register
0x110
0x20
read-write
0x00000000
XFRSIZ
Transfer size
0
19
PKTCNT
Packet count
19
10
DPID
Data PID
29
2
FS_HCTSIZ1
FS_HCTSIZ1
OTG_FS host channel-1 transfer size
register
0x130
0x20
read-write
0x00000000
XFRSIZ
Transfer size
0
19
PKTCNT
Packet count
19
10
DPID
Data PID
29
2
FS_HCTSIZ2
FS_HCTSIZ2
OTG_FS host channel-2 transfer size
register
0x150
0x20
read-write
0x00000000
XFRSIZ
Transfer size
0
19
PKTCNT
Packet count
19
10
DPID
Data PID
29
2
FS_HCTSIZ3
FS_HCTSIZ3
OTG_FS host channel-3 transfer size
register
0x170
0x20
read-write
0x00000000
XFRSIZ
Transfer size
0
19
PKTCNT
Packet count
19
10
DPID
Data PID
29
2
FS_HCTSIZ4
FS_HCTSIZ4
OTG_FS host channel-x transfer size
register
0x190
0x20
read-write
0x00000000
XFRSIZ
Transfer size
0
19
PKTCNT
Packet count
19
10
DPID
Data PID
29
2
FS_HCTSIZ5
FS_HCTSIZ5
OTG_FS host channel-5 transfer size
register
0x1B0
0x20
read-write
0x00000000
XFRSIZ
Transfer size
0
19
PKTCNT
Packet count
19
10
DPID
Data PID
29
2
FS_HCTSIZ6
FS_HCTSIZ6
OTG_FS host channel-6 transfer size
register
0x1D0
0x20
read-write
0x00000000
XFRSIZ
Transfer size
0
19
PKTCNT
Packet count
19
10
DPID
Data PID
29
2
FS_HCTSIZ7
FS_HCTSIZ7
OTG_FS host channel-7 transfer size
register
0x1F0
0x20
read-write
0x00000000
XFRSIZ
Transfer size
0
19
PKTCNT
Packet count
19
10
DPID
Data PID
29
2
OTG_FS_DEVICE
USB on the go full speed
USB_OTG_FS
0x50000800
0x0
0x400
registers
FS_DCFG
FS_DCFG
OTG_FS device configuration register
(OTG_FS_DCFG)
0x0
0x20
read-write
0x02200000
DSPD
Device speed
0
2
NZLSOHSK
Non-zero-length status OUT
handshake
2
1
DAD
Device address
4
7
PFIVL
Periodic frame interval
11
2
FS_DCTL
FS_DCTL
OTG_FS device control register
(OTG_FS_DCTL)
0x4
0x20
0x00000000
RWUSIG
Remote wakeup signaling
0
1
read-write
SDIS
Soft disconnect
1
1
read-write
GINSTS
Global IN NAK status
2
1
read-only
GONSTS
Global OUT NAK status
3
1
read-only
TCTL
Test control
4
3
read-write
SGINAK
Set global IN NAK
7
1
read-write
CGINAK
Clear global IN NAK
8
1
read-write
SGONAK
Set global OUT NAK
9
1
read-write
CGONAK
Clear global OUT NAK
10
1
read-write
POPRGDNE
Power-on programming done
11
1
read-write
FS_DSTS
FS_DSTS
OTG_FS device status register
(OTG_FS_DSTS)
0x8
0x20
read-only
0x00000010
SUSPSTS
Suspend status
0
1
ENUMSPD
Enumerated speed
1
2
EERR
Erratic error
3
1
FNSOF
Frame number of the received
SOF
8
14
FS_DIEPMSK
FS_DIEPMSK
OTG_FS device IN endpoint common interrupt
mask register (OTG_FS_DIEPMSK)
0x10
0x20
read-write
0x00000000
XFRCM
Transfer completed interrupt
mask
0
1
EPDM
Endpoint disabled interrupt
mask
1
1
TOM
Timeout condition mask (Non-isochronous
endpoints)
3
1
ITTXFEMSK
IN token received when TxFIFO empty
mask
4
1
INEPNMM
IN token received with EP mismatch
mask
5
1
INEPNEM
IN endpoint NAK effective
mask
6
1
FS_DOEPMSK
FS_DOEPMSK
OTG_FS device OUT endpoint common interrupt
mask register (OTG_FS_DOEPMSK)
0x14
0x20
read-write
0x00000000
XFRCM
Transfer completed interrupt
mask
0
1
EPDM
Endpoint disabled interrupt
mask
1
1
STUPM
SETUP phase done mask
3
1
OTEPDM
OUT token received when endpoint
disabled mask
4
1
FS_DAINT
FS_DAINT
OTG_FS device all endpoints interrupt
register (OTG_FS_DAINT)
0x18
0x20
read-only
0x00000000
IEPINT
IN endpoint interrupt bits
0
16
OEPINT
OUT endpoint interrupt
bits
16
16
FS_DAINTMSK
FS_DAINTMSK
OTG_FS all endpoints interrupt mask register
(OTG_FS_DAINTMSK)
0x1C
0x20
read-write
0x00000000
IEPM
IN EP interrupt mask bits
0
16
OEPINT
OUT endpoint interrupt
bits
16
16
DVBUSDIS
DVBUSDIS
OTG_FS device VBUS discharge time
register
0x28
0x20
read-write
0x000017D7
VBUSDT
Device VBUS discharge time
0
16
DVBUSPULSE
DVBUSPULSE
OTG_FS device VBUS pulsing time
register
0x2C
0x20
read-write
0x000005B8
DVBUSP
Device VBUS pulsing time
0
12
DIEPEMPMSK
DIEPEMPMSK
OTG_FS device IN endpoint FIFO empty
interrupt mask register
0x34
0x20
read-write
0x00000000
INEPTXFEM
IN EP Tx FIFO empty interrupt mask
bits
0
16
FS_DIEPCTL0
FS_DIEPCTL0
OTG_FS device control IN endpoint 0 control
register (OTG_FS_DIEPCTL0)
0x100
0x20
0x00000000
MPSIZ
Maximum packet size
0
2
read-write
USBAEP
USB active endpoint
15
1
read-only
NAKSTS
NAK status
17
1
read-only
EPTYP
Endpoint type
18
2
read-only
STALL
STALL handshake
21
1
read-write
TXFNUM
TxFIFO number
22
4
read-write
CNAK
Clear NAK
26
1
write-only
SNAK
Set NAK
27
1
write-only
EPDIS
Endpoint disable
30
1
read-only
EPENA
Endpoint enable
31
1
read-only
DIEPCTL1
DIEPCTL1
OTG device endpoint-1 control
register
0x120
0x20
0x00000000
EPENA
EPENA
31
1
read-write
EPDIS
EPDIS
30
1
read-write
SODDFRM_SD1PID
SODDFRM/SD1PID
29
1
write-only
SD0PID_SEVNFRM
SD0PID/SEVNFRM
28
1
write-only
SNAK
SNAK
27
1
write-only
CNAK
CNAK
26
1
write-only
TXFNUM
TXFNUM
22
4
read-write
Stall
Stall
21
1
read-write
EPTYP
EPTYP
18
2
read-write
NAKSTS
NAKSTS
17
1
read-only
EONUM_DPID
EONUM/DPID
16
1
read-only
USBAEP
USBAEP
15
1
read-write
MPSIZ
MPSIZ
0
11
read-write
DIEPCTL2
DIEPCTL2
OTG device endpoint-2 control
register
0x140
0x20
0x00000000
EPENA
EPENA
31
1
read-write
EPDIS
EPDIS
30
1
read-write
SODDFRM
SODDFRM
29
1
write-only
SD0PID_SEVNFRM
SD0PID/SEVNFRM
28
1
write-only
SNAK
SNAK
27
1
write-only
CNAK
CNAK
26
1
write-only
TXFNUM
TXFNUM
22
4
read-write
Stall
Stall
21
1
read-write
EPTYP
EPTYP
18
2
read-write
NAKSTS
NAKSTS
17
1
read-only
EONUM_DPID
EONUM/DPID
16
1
read-only
USBAEP
USBAEP
15
1
read-write
MPSIZ
MPSIZ
0
11
read-write
DIEPCTL3
DIEPCTL3
OTG device endpoint-3 control
register
0x160
0x20
0x00000000
EPENA
EPENA
31
1
read-write
EPDIS
EPDIS
30
1
read-write
SODDFRM
SODDFRM
29
1
write-only
SD0PID_SEVNFRM
SD0PID/SEVNFRM
28
1
write-only
SNAK
SNAK
27
1
write-only
CNAK
CNAK
26
1
write-only
TXFNUM
TXFNUM
22
4
read-write
Stall
Stall
21
1
read-write
EPTYP
EPTYP
18
2
read-write
NAKSTS
NAKSTS
17
1
read-only
EONUM_DPID
EONUM/DPID
16
1
read-only
USBAEP
USBAEP
15
1
read-write
MPSIZ
MPSIZ
0
11
read-write
DOEPCTL0
DOEPCTL0
device endpoint-0 control
register
0x300
0x20
0x00008000
EPENA
EPENA
31
1
write-only
EPDIS
EPDIS
30
1
read-only
SNAK
SNAK
27
1
write-only
CNAK
CNAK
26
1
write-only
Stall
Stall
21
1
read-write
SNPM
SNPM
20
1
read-write
EPTYP
EPTYP
18
2
read-only
NAKSTS
NAKSTS
17
1
read-only
USBAEP
USBAEP
15
1
read-only
MPSIZ
MPSIZ
0
2
read-only
DOEPCTL1
DOEPCTL1
device endpoint-1 control
register
0x320
0x20
0x00000000
EPENA
EPENA
31
1
read-write
EPDIS
EPDIS
30
1
read-write
SODDFRM
SODDFRM
29
1
write-only
SD0PID_SEVNFRM
SD0PID/SEVNFRM
28
1
write-only
SNAK
SNAK
27
1
write-only
CNAK
CNAK
26
1
write-only
Stall
Stall
21
1
read-write
SNPM
SNPM
20
1
read-write
EPTYP
EPTYP
18
2
read-write
NAKSTS
NAKSTS
17
1
read-only
EONUM_DPID
EONUM/DPID
16
1
read-only
USBAEP
USBAEP
15
1
read-write
MPSIZ
MPSIZ
0
11
read-write
DOEPCTL2
DOEPCTL2
device endpoint-2 control
register
0x340
0x20
0x00000000
EPENA
EPENA
31
1
read-write
EPDIS
EPDIS
30
1
read-write
SODDFRM
SODDFRM
29
1
write-only
SD0PID_SEVNFRM
SD0PID/SEVNFRM
28
1
write-only
SNAK
SNAK
27
1
write-only
CNAK
CNAK
26
1
write-only
Stall
Stall
21
1
read-write
SNPM
SNPM
20
1
read-write
EPTYP
EPTYP
18
2
read-write
NAKSTS
NAKSTS
17
1
read-only
EONUM_DPID
EONUM/DPID
16
1
read-only
USBAEP
USBAEP
15
1
read-write
MPSIZ
MPSIZ
0
11
read-write
DOEPCTL3
DOEPCTL3
device endpoint-3 control
register
0x360
0x20
0x00000000
EPENA
EPENA
31
1
read-write
EPDIS
EPDIS
30
1
read-write
SODDFRM
SODDFRM
29
1
write-only
SD0PID_SEVNFRM
SD0PID/SEVNFRM
28
1
write-only
SNAK
SNAK
27
1
write-only
CNAK
CNAK
26
1
write-only
Stall
Stall
21
1
read-write
SNPM
SNPM
20
1
read-write
EPTYP
EPTYP
18
2
read-write
NAKSTS
NAKSTS
17
1
read-only
EONUM_DPID
EONUM/DPID
16
1
read-only
USBAEP
USBAEP
15
1
read-write
MPSIZ
MPSIZ
0
11
read-write
DIEPINT0
DIEPINT0
device endpoint-x interrupt
register
0x108
0x20
0x00000080
TXFE
TXFE
7
1
read-only
INEPNE
INEPNE
6
1
read-write
ITTXFE
ITTXFE
4
1
read-write
TOC
TOC
3
1
read-write
EPDISD
EPDISD
1
1
read-write
XFRC
XFRC
0
1
read-write
DIEPINT1
DIEPINT1
device endpoint-1 interrupt
register
0x128
0x20
0x00000080
TXFE
TXFE
7
1
read-only
INEPNE
INEPNE
6
1
read-write
ITTXFE
ITTXFE
4
1
read-write
TOC
TOC
3
1
read-write
EPDISD
EPDISD
1
1
read-write
XFRC
XFRC
0
1
read-write
DIEPINT2
DIEPINT2
device endpoint-2 interrupt
register
0x148
0x20
0x00000080
TXFE
TXFE
7
1
read-only
INEPNE
INEPNE
6
1
read-write
ITTXFE
ITTXFE
4
1
read-write
TOC
TOC
3
1
read-write
EPDISD
EPDISD
1
1
read-write
XFRC
XFRC
0
1
read-write
DIEPINT3
DIEPINT3
device endpoint-3 interrupt
register
0x168
0x20
0x00000080
TXFE
TXFE
7
1
read-only
INEPNE
INEPNE
6
1
read-write
ITTXFE
ITTXFE
4
1
read-write
TOC
TOC
3
1
read-write
EPDISD
EPDISD
1
1
read-write
XFRC
XFRC
0
1
read-write
DOEPINT0
DOEPINT0
device endpoint-0 interrupt
register
0x308
0x20
read-write
0x00000080
B2BSTUP
B2BSTUP
6
1
OTEPDIS
OTEPDIS
4
1
STUP
STUP
3
1
EPDISD
EPDISD
1
1
XFRC
XFRC
0
1
DOEPINT1
DOEPINT1
device endpoint-1 interrupt
register
0x328
0x20
read-write
0x00000080
B2BSTUP
B2BSTUP
6
1
OTEPDIS
OTEPDIS
4
1
STUP
STUP
3
1
EPDISD
EPDISD
1
1
XFRC
XFRC
0
1
DOEPINT2
DOEPINT2
device endpoint-2 interrupt
register
0x348
0x20
read-write
0x00000080
B2BSTUP
B2BSTUP
6
1
OTEPDIS
OTEPDIS
4
1
STUP
STUP
3
1
EPDISD
EPDISD
1
1
XFRC
XFRC
0
1
DOEPINT3
DOEPINT3
device endpoint-3 interrupt
register
0x368
0x20
read-write
0x00000080
B2BSTUP
B2BSTUP
6
1
OTEPDIS
OTEPDIS
4
1
STUP
STUP
3
1
EPDISD
EPDISD
1
1
XFRC
XFRC
0
1
DIEPTSIZ0
DIEPTSIZ0
device endpoint-0 transfer size
register
0x110
0x20
read-write
0x00000000
PKTCNT
Packet count
19
2
XFRSIZ
Transfer size
0
7
DOEPTSIZ0
DOEPTSIZ0
device OUT endpoint-0 transfer size
register
0x310
0x20
read-write
0x00000000
STUPCNT
SETUP packet count
29
2
PKTCNT
Packet count
19
1
XFRSIZ
Transfer size
0
7
DIEPTSIZ1
DIEPTSIZ1
device endpoint-1 transfer size
register
0x130
0x20
read-write
0x00000000
MCNT
Multi count
29
2
PKTCNT
Packet count
19
10
XFRSIZ
Transfer size
0
19
DIEPTSIZ2
DIEPTSIZ2
device endpoint-2 transfer size
register
0x150
0x20
read-write
0x00000000
MCNT
Multi count
29
2
PKTCNT
Packet count
19
10
XFRSIZ
Transfer size
0
19
DIEPTSIZ3
DIEPTSIZ3
device endpoint-3 transfer size
register
0x170
0x20
read-write
0x00000000
MCNT
Multi count
29
2
PKTCNT
Packet count
19
10
XFRSIZ
Transfer size
0
19
DTXFSTS0
DTXFSTS0
OTG_FS device IN endpoint transmit FIFO
status register
0x118
0x20
read-only
0x00000000
INEPTFSAV
IN endpoint TxFIFO space
available
0
16
DTXFSTS1
DTXFSTS1
OTG_FS device IN endpoint transmit FIFO
status register
0x138
0x20
read-only
0x00000000
INEPTFSAV
IN endpoint TxFIFO space
available
0
16
DTXFSTS2
DTXFSTS2
OTG_FS device IN endpoint transmit FIFO
status register
0x158
0x20
read-only
0x00000000
INEPTFSAV
IN endpoint TxFIFO space
available
0
16
DTXFSTS3
DTXFSTS3
OTG_FS device IN endpoint transmit FIFO
status register
0x178
0x20
read-only
0x00000000
INEPTFSAV
IN endpoint TxFIFO space
available
0
16
DOEPTSIZ1
DOEPTSIZ1
device OUT endpoint-1 transfer size
register
0x330
0x20
read-write
0x00000000
RXDPID_STUPCNT
Received data PID/SETUP packet
count
29
2
PKTCNT
Packet count
19
10
XFRSIZ
Transfer size
0
19
DOEPTSIZ2
DOEPTSIZ2
device OUT endpoint-2 transfer size
register
0x350
0x20
read-write
0x00000000
RXDPID_STUPCNT
Received data PID/SETUP packet
count
29
2
PKTCNT
Packet count
19
10
XFRSIZ
Transfer size
0
19
DOEPTSIZ3
DOEPTSIZ3
device OUT endpoint-3 transfer size
register
0x370
0x20
read-write
0x00000000
RXDPID_STUPCNT
Received data PID/SETUP packet
count
29
2
PKTCNT
Packet count
19
10
XFRSIZ
Transfer size
0
19
OTG_FS_PWRCLK
USB on the go full speed
USB_OTG_FS
0x50000E00
0x0
0x400
registers
FS_PCGCCTL
FS_PCGCCTL
OTG_FS power and clock gating control
register (OTG_FS_PCGCCTL)
0x0
0x20
read-write
0x00000000
STPPCLK
Stop PHY clock
0
1
GATEHCLK
Gate HCLK
1
1
PHYSUSP
PHY Suspended
4
1
SWPMI1
Single Wire Protocol Master
Interface
SWPMI
0x40008800
0x0
0x400
registers
SWPMI1
SWPMI1 global interrupt
76
CR
CR
SWPMI Configuration/Control
register
0x0
0x20
read-write
0x00000000
RXDMA
Reception DMA enable
0
1
TXDMA
Transmission DMA enable
1
1
RXMODE
Reception buffering mode
2
1
TXMODE
Transmission buffering
mode
3
1
LPBK
Loopback mode enable
4
1
SWPACT
Single wire protocol master interface
activate
5
1
DEACT
Single wire protocol master interface
deactivate
10
1
BRR
BRR
SWPMI Bitrate register
0x4
0x20
read-write
0x00000001
BR
Bitrate prescaler
0
6
ISR
ISR
SWPMI Interrupt and Status
register
0xC
0x20
read-only
0x000002C2
RXBFF
Receive buffer full flag
0
1
TXBEF
Transmit buffer empty flag
1
1
RXBERF
Receive CRC error flag
2
1
RXOVRF
Receive overrun error flag
3
1
TXUNRF
Transmit underrun error
flag
4
1
RXNE
Receive data register not
empty
5
1
TXE
Transmit data register
empty
6
1
TCF
Transfer complete flag
7
1
SRF
Slave resume flag
8
1
SUSP
SUSPEND flag
9
1
DEACTF
DEACTIVATED flag
10
1
ICR
ICR
SWPMI Interrupt Flag Clear
register
0x10
0x20
write-only
0x00000000
CRXBFF
Clear receive buffer full
flag
0
1
CTXBEF
Clear transmit buffer empty
flag
1
1
CRXBERF
Clear receive CRC error
flag
2
1
CRXOVRF
Clear receive overrun error
flag
3
1
CTXUNRF
Clear transmit underrun error
flag
4
1
CTCF
Clear transfer complete
flag
7
1
CSRF
Clear slave resume flag
8
1
IER
IER
SWPMI Interrupt Enable
register
0x14
0x20
read-write
0x00000000
RXBFIE
Receive buffer full interrupt
enable
0
1
TXBEIE
Transmit buffer empty interrupt
enable
1
1
RXBERIE
Receive CRC error interrupt
enable
2
1
RXOVRIE
Receive overrun error interrupt
enable
3
1
TXUNRIE
Transmit underrun error interrupt
enable
4
1
RIE
Receive interrupt enable
5
1
TIE
Transmit interrupt enable
6
1
TCIE
Transmit complete interrupt
enable
7
1
SRIE
Slave resume interrupt
enable
8
1
RFL
RFL
SWPMI Receive Frame Length
register
0x18
0x20
read-only
0x00000000
RFL
Receive frame length
0
5
TDR
TDR
SWPMI Transmit data register
0x1C
0x20
write-only
0x00000000
TD
Transmit data
0
32
RDR
RDR
SWPMI Receive data register
0x20
0x20
read-only
0x00000000
RD
received data
0
32
OR
OR
SWPMI Option register
0x24
0x20
read-write
0x00000000
SWP_TBYP
SWP transceiver bypass
0
1
SWP_CLASS
SWP class selection
1
1
OPAMP
Operational amplifiers
OPAMP
0x40007800
0x0
0x400
registers
OPAMP1_CSR
OPAMP1_CSR
OPAMP1 control/status register
0x0
0x20
read-write
0x00000000
OPAEN
Operational amplifier
Enable
0
1
OPALPM
Operational amplifier Low Power
Mode
1
1
OPAMODE
Operational amplifier PGA
mode
2
2
PGA_GAIN
Operational amplifier Programmable
amplifier gain value
4
2
VM_SEL
Inverting input selection
8
2
VP_SEL
Non inverted input
selection
10
1
CALON
Calibration mode enabled
12
1
CALSEL
Calibration selection
13
1
USERTRIM
allows to switch from AOP offset trimmed
values to AOP offset
14
1
CALOUT
Operational amplifier calibration
output
15
1
OPA_RANGE
Operational amplifier power supply range
for stability
31
1
OPAMP1_OTR
OPAMP1_OTR
OPAMP1 offset trimming register in normal
mode
0x4
0x20
read-write
0x00000000
TRIMOFFSETN
Trim for NMOS differential
pairs
0
5
TRIMOFFSETP
Trim for PMOS differential
pairs
8
5
OPAMP1_LPOTR
OPAMP1_LPOTR
OPAMP1 offset trimming register in low-power
mode
0x8
0x20
read-write
0x00000000
TRIMLPOFFSETN
Trim for NMOS differential
pairs
0
5
TRIMLPOFFSETP
Trim for PMOS differential
pairs
8
5
OPAMP2_CSR
OPAMP2_CSR
OPAMP2 control/status register
0x10
0x20
read-write
0x00000000
OPAEN
Operational amplifier
Enable
0
1
OPALPM
Operational amplifier Low Power
Mode
1
1
OPAMODE
Operational amplifier PGA
mode
2
2
PGA_GAIN
Operational amplifier Programmable
amplifier gain value
4
2
VM_SEL
Inverting input selection
8
2
VP_SEL
Non inverted input
selection
10
1
CALON
Calibration mode enabled
12
1
CALSEL
Calibration selection
13
1
USERTRIM
allows to switch from AOP offset trimmed
values to AOP offset
14
1
CALOUT
Operational amplifier calibration
output
15
1
OPAMP2_OTR
OPAMP2_OTR
OPAMP2 offset trimming register in normal
mode
0x14
0x20
read-write
0x00000000
TRIMOFFSETN
Trim for NMOS differential
pairs
0
5
TRIMOFFSETP
Trim for PMOS differential
pairs
8
5
OPAMP2_LPOTR
OPAMP2_LPOTR
OPAMP2 offset trimming register in low-power
mode
0x18
0x20
read-write
0x00000000
TRIMLPOFFSETN
Trim for NMOS differential
pairs
0
5
TRIMLPOFFSETP
Trim for PMOS differential
pairs
8
5
FMC
Flexible memory controller
FMC
0xA0000000
0x0
0x400
registers
FMC
FMC global Interrupt
48
FPU
Floating point interrupt
81
BCR1
BCR1
SRAM/NOR-Flash chip-select control register
1
0x0
0x20
read-write
0x000030D0
MBKEN
MBKEN
0
1
MUXEN
MUXEN
1
1
MTYP
MTYP
2
2
MWID
MWID
4
2
FACCEN
FACCEN
6
1
BURSTEN
BURSTEN
8
1
WAITPOL
WAITPOL
9
1
WAITCFG
WAITCFG
11
1
WREN
WREN
12
1
WAITEN
WAITEN
13
1
EXTMOD
EXTMOD
14
1
ASYNCWAIT
ASYNCWAIT
15
1
CBURSTRW
CBURSTRW
19
1
CCLKEN
CCLKEN
20
1
WFDIS
Write FIFO Disable
21
1
BTR1
BTR1
SRAM/NOR-Flash chip-select timing register
1
0x4
0x20
read-write
0xFFFFFFFF
ACCMOD
ACCMOD
28
2
DATLAT
DATLAT
24
4
CLKDIV
CLKDIV
20
4
BUSTURN
BUSTURN
16
4
DATAST
DATAST
8
8
ADDHLD
ADDHLD
4
4
ADDSET
ADDSET
0
4
BCR2
BCR2
SRAM/NOR-Flash chip-select control register
2
0x8
0x20
read-write
0x000030D0
CBURSTRW
CBURSTRW
19
1
ASYNCWAIT
ASYNCWAIT
15
1
EXTMOD
EXTMOD
14
1
WAITEN
WAITEN
13
1
WREN
WREN
12
1
WAITCFG
WAITCFG
11
1
WRAPMOD
WRAPMOD
10
1
WAITPOL
WAITPOL
9
1
BURSTEN
BURSTEN
8
1
FACCEN
FACCEN
6
1
MWID
MWID
4
2
MTYP
MTYP
2
2
MUXEN
MUXEN
1
1
MBKEN
MBKEN
0
1
BTR2
BTR2
SRAM/NOR-Flash chip-select timing register
2
0xC
0x20
read-write
0xFFFFFFFF
ACCMOD
ACCMOD
28
2
DATLAT
DATLAT
24
4
CLKDIV
CLKDIV
20
4
BUSTURN
BUSTURN
16
4
DATAST
DATAST
8
8
ADDHLD
ADDHLD
4
4
ADDSET
ADDSET
0
4
BCR3
BCR3
SRAM/NOR-Flash chip-select control register
3
0x10
0x20
read-write
0x000030D0
CBURSTRW
CBURSTRW
19
1
ASYNCWAIT
ASYNCWAIT
15
1
EXTMOD
EXTMOD
14
1
WAITEN
WAITEN
13
1
WREN
WREN
12
1
WAITCFG
WAITCFG
11
1
WRAPMOD
WRAPMOD
10
1
WAITPOL
WAITPOL
9
1
BURSTEN
BURSTEN
8
1
FACCEN
FACCEN
6
1
MWID
MWID
4
2
MTYP
MTYP
2
2
MUXEN
MUXEN
1
1
MBKEN
MBKEN
0
1
BTR3
BTR3
SRAM/NOR-Flash chip-select timing register
3
0x14
0x20
read-write
0xFFFFFFFF
ACCMOD
ACCMOD
28
2
DATLAT
DATLAT
24
4
CLKDIV
CLKDIV
20
4
BUSTURN
BUSTURN
16
4
DATAST
DATAST
8
8
ADDHLD
ADDHLD
4
4
ADDSET
ADDSET
0
4
BCR4
BCR4
SRAM/NOR-Flash chip-select control register
4
0x18
0x20
read-write
0x000030D0
CBURSTRW
CBURSTRW
19
1
ASYNCWAIT
ASYNCWAIT
15
1
EXTMOD
EXTMOD
14
1
WAITEN
WAITEN
13
1
WREN
WREN
12
1
WAITCFG
WAITCFG
11
1
WRAPMOD
WRAPMOD
10
1
WAITPOL
WAITPOL
9
1
BURSTEN
BURSTEN
8
1
FACCEN
FACCEN
6
1
MWID
MWID
4
2
MTYP
MTYP
2
2
MUXEN
MUXEN
1
1
MBKEN
MBKEN
0
1
BTR4
BTR4
SRAM/NOR-Flash chip-select timing register
4
0x1C
0x20
read-write
0xFFFFFFFF
ACCMOD
ACCMOD
28
2
DATLAT
DATLAT
24
4
CLKDIV
CLKDIV
20
4
BUSTURN
BUSTURN
16
4
DATAST
DATAST
8
8
ADDHLD
ADDHLD
4
4
ADDSET
ADDSET
0
4
PCR
PCR
PC Card/NAND Flash control register
3
0x80
0x20
read-write
0x00000018
ECCPS
ECCPS
17
3
TAR
TAR
13
4
TCLR
TCLR
9
4
ECCEN
ECCEN
6
1
PWID
PWID
4
2
PTYP
PTYP
3
1
PBKEN
PBKEN
2
1
PWAITEN
PWAITEN
1
1
SR
SR
FIFO status and interrupt register
3
0x84
0x20
0x00000040
FEMPT
FEMPT
6
1
read-only
IFEN
IFEN
5
1
read-write
ILEN
ILEN
4
1
read-write
IREN
IREN
3
1
read-write
IFS
IFS
2
1
read-write
ILS
ILS
1
1
read-write
IRS
IRS
0
1
read-write
PMEM
PMEM
Common memory space timing register
3
0x88
0x20
read-write
0xFCFCFCFC
MEMHIZx
MEMHIZx
24
8
MEMHOLDx
MEMHOLDx
16
8
MEMWAITx
MEMWAITx
8
8
MEMSETx
MEMSETx
0
8
PATT
PATT
Attribute memory space timing register
3
0x8C
0x20
read-write
0xFCFCFCFC
ATTHIZx
ATTHIZx
24
8
ATTHOLDx
ATTHOLDx
16
8
ATTWAITx
ATTWAITx
8
8
ATTSETx
ATTSETx
0
8
ECCR
ECCR
ECC result register 3
0x94
0x20
read-only
0x00000000
ECCx
ECCx
0
32
BWTR1
BWTR1
SRAM/NOR-Flash write timing registers
1
0x104
0x20
read-write
0x0FFFFFFF
ACCMOD
ACCMOD
28
2
DATLAT
DATLAT
24
4
CLKDIV
CLKDIV
20
4
DATAST
DATAST
8
8
ADDHLD
ADDHLD
4
4
ADDSET
ADDSET
0
4
BWTR2
BWTR2
SRAM/NOR-Flash write timing registers
2
0x10C
0x20
read-write
0x0FFFFFFF
ACCMOD
ACCMOD
28
2
DATLAT
DATLAT
24
4
CLKDIV
CLKDIV
20
4
DATAST
DATAST
8
8
ADDHLD
ADDHLD
4
4
ADDSET
ADDSET
0
4
BWTR3
BWTR3
SRAM/NOR-Flash write timing registers
3
0x114
0x20
read-write
0x0FFFFFFF
ACCMOD
ACCMOD
28
2
DATLAT
DATLAT
24
4
CLKDIV
CLKDIV
20
4
DATAST
DATAST
8
8
ADDHLD
ADDHLD
4
4
ADDSET
ADDSET
0
4
BWTR4
BWTR4
SRAM/NOR-Flash write timing registers
4
0x11C
0x20
read-write
0x0FFFFFFF
ACCMOD
ACCMOD
28
2
DATLAT
DATLAT
24
4
CLKDIV
CLKDIV
20
4
DATAST
DATAST
8
8
ADDHLD
ADDHLD
4
4
ADDSET
ADDSET
0
4
NVIC
Nested Vectored Interrupt
Controller
NVIC
0xE000E100
0x0
0x356
registers
ISER0
ISER0
Interrupt Set-Enable Register
0x0
0x20
read-write
0x00000000
SETENA
SETENA
0
32
ISER1
ISER1
Interrupt Set-Enable Register
0x4
0x20
read-write
0x00000000
SETENA
SETENA
0
32
ISER2
ISER2
Interrupt Set-Enable Register
0x8
0x20
read-write
0x00000000
SETENA
SETENA
0
32
ICER0
ICER0
Interrupt Clear-Enable
Register
0x80
0x20
read-write
0x00000000
CLRENA
CLRENA
0
32
ICER1
ICER1
Interrupt Clear-Enable
Register
0x84
0x20
read-write
0x00000000
CLRENA
CLRENA
0
32
ICER2
ICER2
Interrupt Clear-Enable
Register
0x88
0x20
read-write
0x00000000
CLRENA
CLRENA
0
32
ISPR0
ISPR0
Interrupt Set-Pending Register
0x100
0x20
read-write
0x00000000
SETPEND
SETPEND
0
32
ISPR1
ISPR1
Interrupt Set-Pending Register
0x104
0x20
read-write
0x00000000
SETPEND
SETPEND
0
32
ISPR2
ISPR2
Interrupt Set-Pending Register
0x108
0x20
read-write
0x00000000
SETPEND
SETPEND
0
32
ICPR0
ICPR0
Interrupt Clear-Pending
Register
0x180
0x20
read-write
0x00000000
CLRPEND
CLRPEND
0
32
ICPR1
ICPR1
Interrupt Clear-Pending
Register
0x184
0x20
read-write
0x00000000
CLRPEND
CLRPEND
0
32
ICPR2
ICPR2
Interrupt Clear-Pending
Register
0x188
0x20
read-write
0x00000000
CLRPEND
CLRPEND
0
32
IABR0
IABR0
Interrupt Active Bit Register
0x200
0x20
read-only
0x00000000
ACTIVE
ACTIVE
0
32
IABR1
IABR1
Interrupt Active Bit Register
0x204
0x20
read-only
0x00000000
ACTIVE
ACTIVE
0
32
IABR2
IABR2
Interrupt Active Bit Register
0x208
0x20
read-only
0x00000000
ACTIVE
ACTIVE
0
32
IPR0
IPR0
Interrupt Priority Register
0x300
0x20
read-write
0x00000000
IPR_N0
IPR_N0
0
8
IPR_N1
IPR_N1
8
8
IPR_N2
IPR_N2
16
8
IPR_N3
IPR_N3
24
8
IPR1
IPR1
Interrupt Priority Register
0x304
0x20
read-write
0x00000000
IPR_N0
IPR_N0
0
8
IPR_N1
IPR_N1
8
8
IPR_N2
IPR_N2
16
8
IPR_N3
IPR_N3
24
8
IPR2
IPR2
Interrupt Priority Register
0x308
0x20
read-write
0x00000000
IPR_N0
IPR_N0
0
8
IPR_N1
IPR_N1
8
8
IPR_N2
IPR_N2
16
8
IPR_N3
IPR_N3
24
8
IPR3
IPR3
Interrupt Priority Register
0x30C
0x20
read-write
0x00000000
IPR_N0
IPR_N0
0
8
IPR_N1
IPR_N1
8
8
IPR_N2
IPR_N2
16
8
IPR_N3
IPR_N3
24
8
IPR4
IPR4
Interrupt Priority Register
0x310
0x20
read-write
0x00000000
IPR_N0
IPR_N0
0
8
IPR_N1
IPR_N1
8
8
IPR_N2
IPR_N2
16
8
IPR_N3
IPR_N3
24
8
IPR5
IPR5
Interrupt Priority Register
0x314
0x20
read-write
0x00000000
IPR_N0
IPR_N0
0
8
IPR_N1
IPR_N1
8
8
IPR_N2
IPR_N2
16
8
IPR_N3
IPR_N3
24
8
IPR6
IPR6
Interrupt Priority Register
0x318
0x20
read-write
0x00000000
IPR_N0
IPR_N0
0
8
IPR_N1
IPR_N1
8
8
IPR_N2
IPR_N2
16
8
IPR_N3
IPR_N3
24
8
IPR7
IPR7
Interrupt Priority Register
0x31C
0x20
read-write
0x00000000
IPR_N0
IPR_N0
0
8
IPR_N1
IPR_N1
8
8
IPR_N2
IPR_N2
16
8
IPR_N3
IPR_N3
24
8
IPR8
IPR8
Interrupt Priority Register
0x320
0x20
read-write
0x00000000
IPR_N0
IPR_N0
0
8
IPR_N1
IPR_N1
8
8
IPR_N2
IPR_N2
16
8
IPR_N3
IPR_N3
24
8
IPR9
IPR9
Interrupt Priority Register
0x324
0x20
read-write
0x00000000
IPR_N0
IPR_N0
0
8
IPR_N1
IPR_N1
8
8
IPR_N2
IPR_N2
16
8
IPR_N3
IPR_N3
24
8
IPR10
IPR10
Interrupt Priority Register
0x328
0x20
read-write
0x00000000
IPR_N0
IPR_N0
0
8
IPR_N1
IPR_N1
8
8
IPR_N2
IPR_N2
16
8
IPR_N3
IPR_N3
24
8
IPR11
IPR11
Interrupt Priority Register
0x32C
0x20
read-write
0x00000000
IPR_N0
IPR_N0
0
8
IPR_N1
IPR_N1
8
8
IPR_N2
IPR_N2
16
8
IPR_N3
IPR_N3
24
8
IPR12
IPR12
Interrupt Priority Register
0x330
0x20
read-write
0x00000000
IPR_N0
IPR_N0
0
8
IPR_N1
IPR_N1
8
8
IPR_N2
IPR_N2
16
8
IPR_N3
IPR_N3
24
8
IPR13
IPR13
Interrupt Priority Register
0x334
0x20
read-write
0x00000000
IPR_N0
IPR_N0
0
8
IPR_N1
IPR_N1
8
8
IPR_N2
IPR_N2
16
8
IPR_N3
IPR_N3
24
8
IPR14
IPR14
Interrupt Priority Register
0x338
0x20
read-write
0x00000000
IPR_N0
IPR_N0
0
8
IPR_N1
IPR_N1
8
8
IPR_N2
IPR_N2
16
8
IPR_N3
IPR_N3
24
8
IPR15
IPR15
Interrupt Priority Register
0x33C
0x20
read-write
0x00000000
IPR_N0
IPR_N0
0
8
IPR_N1
IPR_N1
8
8
IPR_N2
IPR_N2
16
8
IPR_N3
IPR_N3
24
8
IPR16
IPR16
Interrupt Priority Register
0x340
0x20
read-write
0x00000000
IPR_N0
IPR_N0
0
8
IPR_N1
IPR_N1
8
8
IPR_N2
IPR_N2
16
8
IPR_N3
IPR_N3
24
8
IPR17
IPR17
Interrupt Priority Register
0x344
0x20
read-write
0x00000000
IPR_N0
IPR_N0
0
8
IPR_N1
IPR_N1
8
8
IPR_N2
IPR_N2
16
8
IPR_N3
IPR_N3
24
8
IPR18
IPR18
Interrupt Priority Register
0x348
0x20
read-write
0x00000000
IPR_N0
IPR_N0
0
8
IPR_N1
IPR_N1
8
8
IPR_N2
IPR_N2
16
8
IPR_N3
IPR_N3
24
8
IPR19
IPR19
Interrupt Priority Register
0x34C
0x20
read-write
0x00000000
IPR_N0
IPR_N0
0
8
IPR_N1
IPR_N1
8
8
IPR_N2
IPR_N2
16
8
IPR_N3
IPR_N3
24
8
IPR20
IPR20
Interrupt Priority Register
0x350
0x20
read-write
0x00000000
IPR_N0
IPR_N0
0
8
IPR_N1
IPR_N1
8
8
IPR_N2
IPR_N2
16
8
IPR_N3
IPR_N3
24
8
CRS
Clock recovery system
CRS
0x40006000
0x0
0x400
registers
CRS
CRS global interrupt
82
CR
CR
control register
0x0
0x20
read-write
0x00002000
TRIM
HSI48 oscillator smooth
trimming
8
6
SWSYNC
Generate software SYNC
event
7
1
AUTOTRIMEN
Automatic trimming enable
6
1
CEN
Frequency error counter
enable
5
1
ESYNCIE
Expected SYNC interrupt
enable
3
1
ERRIE
Synchronization or trimming error
interrupt enable
2
1
SYNCWARNIE
SYNC warning interrupt
enable
1
1
SYNCOKIE
SYNC event OK interrupt
enable
0
1
CFGR
CFGR
configuration register
0x4
0x20
read-write
0x2022BB7F
SYNCPOL
SYNC polarity selection
31
1
SYNCSRC
SYNC signal source
selection
28
2
SYNCDIV
SYNC divider
24
3
FELIM
Frequency error limit
16
8
RELOAD
Counter reload value
0
16
ISR
ISR
interrupt and status register
0x8
0x20
read-only
0x00000000
FECAP
Frequency error capture
16
16
FEDIR
Frequency error direction
15
1
TRIMOVF
Trimming overflow or
underflow
10
1
SYNCMISS
SYNC missed
9
1
SYNCERR
SYNC error
8
1
ESYNCF
Expected SYNC flag
3
1
ERRF
Error flag
2
1
SYNCWARNF
SYNC warning flag
1
1
SYNCOKF
SYNC event OK flag
0
1
ICR
ICR
interrupt flag clear register
0xC
0x20
read-write
0x00000000
ESYNCC
Expected SYNC clear flag
3
1
ERRC
Error clear flag
2
1
SYNCWARNC
SYNC warning clear flag
1
1
SYNCOKC
SYNC event OK clear flag
0
1
DCMI
Digital camera interface
DCMI
0x50050000
0x0
0x400
registers
DCMI
DCMI global interrupt
85
CR
CR
control register 1
0x0
0x20
read-write
0x0000
ENABLE
DCMI enable
14
1
EDM
Extended data mode
10
2
FCRC
Frame capture rate control
8
2
VSPOL
Vertical synchronization
polarity
7
1
HSPOL
Horizontal synchronization
polarity
6
1
PCKPOL
Pixel clock polarity
5
1
ESS
Embedded synchronization
select
4
1
JPEG
JPEG format
3
1
CROP
Crop feature
2
1
CM
Capture mode
1
1
CAPTURE
Capture enable
0
1
OELS
Odd/Even Line Select (Line Select
Start)
20
1
LSM
Line Select mode
19
1
OEBS
Odd/Even Byte Select (Byte Select
Start)
18
1
BSM
Byte Select mode
16
2
SR
SR
status register
0x4
0x20
read-only
0x0000
FNE
FIFO not empty
2
1
VSYNC
VSYNC
1
1
HSYNC
HSYNC
0
1
RIS
RIS
raw interrupt status register
0x8
0x20
read-only
0x0000
LINE_RIS
Line raw interrupt status
4
1
VSYNC_RIS
VSYNC raw interrupt status
3
1
ERR_RIS
Synchronization error raw interrupt
status
2
1
OVR_RIS
Overrun raw interrupt
status
1
1
FRAME_RIS
Capture complete raw interrupt
status
0
1
IER
IER
interrupt enable register
0xC
0x20
read-write
0x0000
LINE_IE
Line interrupt enable
4
1
VSYNC_IE
VSYNC interrupt enable
3
1
ERR_IE
Synchronization error interrupt
enable
2
1
OVR_IE
Overrun interrupt enable
1
1
FRAME_IE
Capture complete interrupt
enable
0
1
MIS
MIS
masked interrupt status
register
0x10
0x20
read-only
0x0000
LINE_MIS
Line masked interrupt
status
4
1
VSYNC_MIS
VSYNC masked interrupt
status
3
1
ERR_MIS
Synchronization error masked interrupt
status
2
1
OVR_MIS
Overrun masked interrupt
status
1
1
FRAME_MIS
Capture complete masked interrupt
status
0
1
ICR
ICR
interrupt clear register
0x14
0x20
write-only
0x0000
LINE_ISC
line interrupt status
clear
4
1
VSYNC_ISC
Vertical synch interrupt status
clear
3
1
ERR_ISC
Synchronization error interrupt status
clear
2
1
OVR_ISC
Overrun interrupt status
clear
1
1
FRAME_ISC
Capture complete interrupt status
clear
0
1
ESCR
ESCR
embedded synchronization code
register
0x18
0x20
read-write
0x0000
FEC
Frame end delimiter code
24
8
LEC
Line end delimiter code
16
8
LSC
Line start delimiter code
8
8
FSC
Frame start delimiter code
0
8
ESUR
ESUR
embedded synchronization unmask
register
0x1C
0x20
read-write
0x0000
FEU
Frame end delimiter unmask
24
8
LEU
Line end delimiter unmask
16
8
LSU
Line start delimiter
unmask
8
8
FSU
Frame start delimiter
unmask
0
8
CWSTRT
CWSTRT
crop window start
0x20
0x20
read-write
0x0000
VST
Vertical start line count
16
13
HOFFCNT
Horizontal offset count
0
14
CWSIZE
CWSIZE
crop window size
0x24
0x20
read-write
0x0000
VLINE
Vertical line count
16
14
CAPCNT
Capture count
0
14
DR
DR
data register
0x28
0x20
read-only
0x0000
Byte3
Data byte 3
24
8
Byte2
Data byte 2
16
8
Byte1
Data byte 1
8
8
Byte0
Data byte 0
0
8
HASH
Hash processor
HASH
0x50060400
0x0
0x400
registers
CR
CR
control register
0x0
0x20
0x00000000
INIT
Initialize message digest
calculation
2
1
write-only
DMAE
DMA enable
3
1
read-write
DATATYPE
Data type selection
4
2
read-write
MODE
Mode selection
6
1
read-write
ALGO0
Algorithm selection
7
1
read-write
NBW
Number of words already
pushed
8
4
read-only
DINNE
DIN not empty
12
1
read-only
MDMAT
Multiple DMA Transfers
13
1
read-write
LKEY
Long key selection
16
1
read-write
ALGO1
ALGO
18
1
read-write
DIN
DIN
data input register
0x4
0x20
read-write
0x00000000
DATAIN
Data input
0
32
STR
STR
start register
0x8
0x20
0x00000000
DCAL
Digest calculation
8
1
write-only
NBLW
Number of valid bits in the last word of
the message
0
5
read-write
HR0
HR0
digest registers
0xC
0x20
read-only
0x00000000
H0
H0
0
32
IMR
IMR
interrupt enable register
0x20
0x20
read-write
0x00000000
DCIE
Digest calculation completion interrupt
enable
1
1
DINIE
Data input interrupt
enable
0
1
SR
SR
status register
0x24
0x20
0x00000001
BUSY
Busy bit
3
1
read-only
DMAS
DMA Status
2
1
read-only
DCIS
Digest calculation completion interrupt
status
1
1
read-write
DINIS
Data input interrupt
status
0
1
read-write
CSR0
CSR0
context swap registers
0xF8
0x20
read-write
0x00000000
CSR0
CSR0
0
32
CSR1
CSR1
context swap registers
0xFC
0x20
read-write
0x00000000
CSR1
CSR1
0
32
CSR2
CSR2
context swap registers
0x100
0x20
read-write
0x00000000
CSR2
CSR2
0
32
CSR3
CSR3
context swap registers
0x104
0x20
read-write
0x00000000
CSR3
CSR3
0
32
CSR4
CSR4
context swap registers
0x108
0x20
read-write
0x00000000
CSR4
CSR4
0
32
CSR5
CSR5
context swap registers
0x10C
0x20
read-write
0x00000000
CSR5
CSR5
0
32
CSR6
CSR6
context swap registers
0x110
0x20
read-write
0x00000000
CSR6
CSR6
0
32
CSR7
CSR7
context swap registers
0x114
0x20
read-write
0x00000000
CSR7
CSR7
0
32
CSR8
CSR8
context swap registers
0x118
0x20
read-write
0x00000000
CSR8
CSR8
0
32
CSR9
CSR9
context swap registers
0x11C
0x20
read-write
0x00000000
CSR9
CSR9
0
32
CSR10
CSR10
context swap registers
0x120
0x20
read-write
0x00000000
CSR10
CSR10
0
32
CSR11
CSR11
context swap registers
0x124
0x20
read-write
0x00000000
CSR11
CSR11
0
32
CSR12
CSR12
context swap registers
0x128
0x20
read-write
0x00000000
CSR12
CSR12
0
32
CSR13
CSR13
context swap registers
0x12C
0x20
read-write
0x00000000
CSR13
CSR13
0
32
CSR14
CSR14
context swap registers
0x130
0x20
read-write
0x00000000
CSR14
CSR14
0
32
CSR15
CSR15
context swap registers
0x134
0x20
read-write
0x00000000
CSR15
CSR15
0
32
CSR16
CSR16
context swap registers
0x138
0x20
read-write
0x00000000
CSR16
CSR16
0
32
CSR17
CSR17
context swap registers
0x13C
0x20
read-write
0x00000000
CSR17
CSR17
0
32
CSR18
CSR18
context swap registers
0x140
0x20
read-write
0x00000000
CSR18
CSR18
0
32
CSR19
CSR19
context swap registers
0x144
0x20
read-write
0x00000000
CSR19
CSR19
0
32
CSR20
CSR20
context swap registers
0x148
0x20
read-write
0x00000000
CSR20
CSR20
0
32
CSR21
CSR21
context swap registers
0x14C
0x20
read-write
0x00000000
CSR21
CSR21
0
32
CSR22
CSR22
context swap registers
0x150
0x20
read-write
0x00000000
CSR22
CSR22
0
32
CSR23
CSR23
context swap registers
0x154
0x20
read-write
0x00000000
CSR23
CSR23
0
32
CSR24
CSR24
context swap registers
0x158
0x20
read-write
0x00000000
CSR24
CSR24
0
32
CSR25
CSR25
context swap registers
0x15C
0x20
read-write
0x00000000
CSR25
CSR25
0
32
CSR26
CSR26
context swap registers
0x160
0x20
read-write
0x00000000
CSR26
CSR26
0
32
CSR27
CSR27
context swap registers
0x164
0x20
read-write
0x00000000
CSR27
CSR27
0
32
CSR28
CSR28
context swap registers
0x168
0x20
read-write
0x00000000
CSR28
CSR28
0
32
CSR29
CSR29
context swap registers
0x16C
0x20
read-write
0x00000000
CSR29
CSR29
0
32
CSR30
CSR30
context swap registers
0x170
0x20
read-write
0x00000000
CSR30
CSR30
0
32
CSR31
CSR31
context swap registers
0x174
0x20
read-write
0x00000000
CSR31
CSR31
0
32
CSR32
CSR32
context swap registers
0x178
0x20
read-write
0x00000000
CSR32
CSR32
0
32
CSR33
CSR33
context swap registers
0x17C
0x20
read-write
0x00000000
CSR33
CSR33
0
32
CSR34
CSR34
context swap registers
0x180
0x20
read-write
0x00000000
CSR34
CSR34
0
32
CSR35
CSR35
context swap registers
0x184
0x20
read-write
0x00000000
CSR35
CSR35
0
32
CSR36
CSR36
context swap registers
0x188
0x20
read-write
0x00000000
CSR36
CSR36
0
32
CSR37
CSR37
context swap registers
0x18C
0x20
read-write
0x00000000
CSR37
CSR37
0
32
CSR38
CSR38
context swap registers
0x190
0x20
read-write
0x00000000
CSR38
CSR38
0
32
CSR39
CSR39
context swap registers
0x194
0x20
read-write
0x00000000
CSR39
CSR39
0
32
CSR40
CSR40
context swap registers
0x198
0x20
read-write
0x00000000
CSR40
CSR40
0
32
CSR41
CSR41
context swap registers
0x19C
0x20
read-write
0x00000000
CSR41
CSR41
0
32
CSR42
CSR42
context swap registers
0x1A0
0x20
read-write
0x00000000
CSR42
CSR42
0
32
CSR43
CSR43
context swap registers
0x1A4
0x20
read-write
0x00000000
CSR43
CSR43
0
32
CSR44
CSR44
context swap registers
0x1A8
0x20
read-write
0x00000000
CSR44
CSR44
0
32
CSR45
CSR45
context swap registers
0x1AC
0x20
read-write
0x00000000
CSR45
CSR45
0
32
CSR46
CSR46
context swap registers
0x1B0
0x20
read-write
0x00000000
CSR46
CSR46
0
32
CSR47
CSR47
context swap registers
0x1B4
0x20
read-write
0x00000000
CSR47
CSR47
0
32
CSR48
CSR48
context swap registers
0x1B8
0x20
read-write
0x00000000
CSR48
CSR48
0
32
CSR49
CSR49
context swap registers
0x1BC
0x20
read-write
0x00000000
CSR49
CSR49
0
32
CSR50
CSR50
context swap registers
0x1C0
0x20
read-write
0x00000000
CSR50
CSR50
0
32
CSR51
CSR51
context swap registers
0x1C4
0x20
read-write
0x00000000
CSR51
CSR51
0
32
CSR52
CSR52
context swap registers
0x1C8
0x20
read-write
0x00000000
CSR52
CSR52
0
32
CSR53
CSR53
context swap registers
0x1CC
0x20
read-write
0x00000000
CSR53
CSR53
0
32
HASH_HR0
HASH_HR0
HASH digest register
0x310
0x20
read-only
0x00000000
H0
H0
0
32
HASH_HR1
HASH_HR1
read-only
0x314
0x20
read-only
0x00000000
H1
H1
0
32
HASH_HR2
HASH_HR2
read-only
0x318
0x20
read-only
0x00000000
H2
H2
0
32
HASH_HR3
HASH_HR3
read-only
0x31C
0x20
read-only
0x00000000
H3
H3
0
32
HASH_HR4
HASH_HR4
read-only
0x320
0x20
read-only
0x00000000
H4
H4
0
32
HASH_HR5
HASH_HR5
read-only
0x324
0x20
read-only
0x00000000
H5
H5
0
32
HASH_HR6
HASH_HR6
read-only
0x328
0x20
read-only
0x00000000
H6
H6
0
32
HASH_HR7
HASH_HR7
read-only
0x32C
0x20
read-only
0x00000000
H7
H7
0
32
DMA2D
DMA2D controller
DMA2D
0x4002B000
0x0
0xC00
registers
DMA2D
DMA2D global interrupt
90
CR
CR
control register
0x0
0x20
read-write
0x00000000
MODE
DMA2D mode
16
2
CEIE
Configuration Error Interrupt
Enable
13
1
CTCIE
CLUT transfer complete interrupt
enable
12
1
CAEIE
CLUT access error interrupt
enable
11
1
TWIE
Transfer watermark interrupt
enable
10
1
TCIE
Transfer complete interrupt
enable
9
1
TEIE
Transfer error interrupt
enable
8
1
ABORT
Abort
2
1
SUSP
Suspend
1
1
START
Start
0
1
ISR
ISR
Interrupt Status Register
0x4
0x20
read-only
0x00000000
CEIF
Configuration error interrupt
flag
5
1
CTCIF
CLUT transfer complete interrupt
flag
4
1
CAEIF
CLUT access error interrupt
flag
3
1
TWIF
Transfer watermark interrupt
flag
2
1
TCIF
Transfer complete interrupt
flag
1
1
TEIF
Transfer error interrupt
flag
0
1
IFCR
IFCR
interrupt flag clear register
0x8
0x20
read-write
0x00000000
CCEIF
Clear configuration error interrupt
flag
5
1
CCTCIF
Clear CLUT transfer complete interrupt
flag
4
1
CAECIF
Clear CLUT access error interrupt
flag
3
1
CTWIF
Clear transfer watermark interrupt
flag
2
1
CTCIF
Clear transfer complete interrupt
flag
1
1
CTEIF
Clear Transfer error interrupt
flag
0
1
FGMAR
FGMAR
foreground memory address
register
0xC
0x20
read-write
0x00000000
MA
Memory address
0
32
FGOR
FGOR
foreground offset register
0x10
0x20
read-write
0x00000000
LO
Line offset
0
14
BGMAR
BGMAR
background memory address
register
0x14
0x20
read-write
0x00000000
MA
Memory address
0
32
BGOR
BGOR
background offset register
0x18
0x20
read-write
0x00000000
LO
Line offset
0
14
FGPFCCR
FGPFCCR
foreground PFC control
register
0x1C
0x20
read-write
0x00000000
ALPHA
Alpha value
24
8
AM
Alpha mode
16
2
CS
CLUT size
8
8
START
Start
5
1
CCM
CLUT color mode
4
1
CM
Color mode
0
4
RBS
Red Blue Swap
21
1
AI
Alpha Inverted
20
1
FGCOLR
FGCOLR
foreground color register
0x20
0x20
read-write
0x00000000
RED
Red Value
16
8
GREEN
Green Value
8
8
BLUE
Blue Value
0
8
BGPFCCR
BGPFCCR
background PFC control
register
0x24
0x20
read-write
0x00000000
ALPHA
Alpha value
24
8
AM
Alpha mode
16
2
CS
CLUT size
8
8
START
Start
5
1
CCM
CLUT Color mode
4
1
CM
Color mode
0
4
RBS
Red Blue Swap
21
1
AI
Alpha Inverted
20
1
BGCOLR
BGCOLR
background color register
0x28
0x20
read-write
0x00000000
RED
Red Value
16
8
GREEN
Green Value
8
8
BLUE
Blue Value
0
8
FGCMAR
FGCMAR
foreground CLUT memory address
register
0x2C
0x20
read-write
0x00000000
MA
Memory Address
0
32
BGCMAR
BGCMAR
background CLUT memory address
register
0x30
0x20
read-write
0x00000000
MA
Memory address
0
32
OPFCCR
OPFCCR
output PFC control register
0x34
0x20
read-write
0x00000000
CM
Color mode
0
3
RBS
Red Blue Swap
21
1
AI
Alpha Inverted
20
1
OCOLR
OCOLR
output color register
0x38
0x20
read-write
0x00000000
APLHA
Alpha Channel Value
24
8
RED
Red Value
16
8
GREEN
Green Value
8
8
BLUE
Blue Value
0
8
OMAR
OMAR
output memory address register
0x3C
0x20
read-write
0x00000000
MA
Memory Address
0
32
OOR
OOR
output offset register
0x40
0x20
read-write
0x00000000
LO
Line Offset
0
14
NLR
NLR
number of line register
0x44
0x20
read-write
0x00000000
PL
Pixel per lines
16
14
NL
Number of lines
0
16
LWR
LWR
line watermark register
0x48
0x20
read-write
0x00000000
LW
Line watermark
0
16
AMTCR
AMTCR
AHB master timer configuration
register
0x4C
0x20
read-write
0x00000000
DT
Dead Time
8
8
EN
Enable
0
1
FGCLUT
FGCLUT
FGCLUT
0x400
0x20
read-write
0x00000000
APLHA
APLHA
24
8
RED
RED
16
8
GREEN
GREEN
8
8
BLUE
BLUE
0
8
BGCLUT
BGCLUT
BGCLUT
0x800
0x20
read-write
0x00000000
APLHA
APLHA
24
8
RED
RED
16
8
GREEN
GREEN
8
8
BLUE
BLUE
0
8
FPU
Floting point unit
FPU
0xE000EF34
0x0
0xD
registers
FPU
Floating point interrupt
81
FPCCR
FPCCR
Floating-point context control
register
0x0
0x20
read-write
0x00000000
LSPACT
LSPACT
0
1
USER
USER
1
1
THREAD
THREAD
3
1
HFRDY
HFRDY
4
1
MMRDY
MMRDY
5
1
BFRDY
BFRDY
6
1
MONRDY
MONRDY
8
1
LSPEN
LSPEN
30
1
ASPEN
ASPEN
31
1
FPCAR
FPCAR
Floating-point context address
register
0x4
0x20
read-write
0x00000000
ADDRESS
Location of unpopulated
floating-point
3
29
FPSCR
FPSCR
Floating-point status control
register
0x8
0x20
read-write
0x00000000
IOC
Invalid operation cumulative exception
bit
0
1
DZC
Division by zero cumulative exception
bit.
1
1
OFC
Overflow cumulative exception
bit
2
1
UFC
Underflow cumulative exception
bit
3
1
IXC
Inexact cumulative exception
bit
4
1
IDC
Input denormal cumulative exception
bit.
7
1
RMode
Rounding Mode control
field
22
2
FZ
Flush-to-zero mode control
bit:
24
1
DN
Default NaN mode control
bit
25
1
AHP
Alternative half-precision control
bit
26
1
V
Overflow condition code
flag
28
1
C
Carry condition code flag
29
1
Z
Zero condition code flag
30
1
N
Negative condition code
flag
31
1
MPU
Memory protection unit
MPU
0xE000ED90
0x0
0x15
registers
MPU_TYPER
MPU_TYPER
MPU type register
0x0
0x20
read-only
0X00000800
SEPARATE
Separate flag
0
1
DREGION
Number of MPU data regions
8
8
IREGION
Number of MPU instruction
regions
16
8
MPU_CTRL
MPU_CTRL
MPU control register
0x4
0x20
read-only
0X00000000
ENABLE
Enables the MPU
0
1
HFNMIENA
Enables the operation of MPU during hard
fault
1
1
PRIVDEFENA
Enable priviliged software access to
default memory map
2
1
MPU_RNR
MPU_RNR
MPU region number register
0x8
0x20
read-write
0X00000000
REGION
MPU region
0
8
MPU_RBAR
MPU_RBAR
MPU region base address
register
0xC
0x20
read-write
0X00000000
REGION
MPU region field
0
4
VALID
MPU region number valid
4
1
ADDR
Region base address field
5
27
MPU_RASR
MPU_RASR
MPU region attribute and size
register
0x10
0x20
read-write
0X00000000
ENABLE
Region enable bit.
0
1
SIZE
Size of the MPU protection
region
1
5
SRD
Subregion disable bits
8
8
B
memory attribute
16
1
C
memory attribute
17
1
S
Shareable memory attribute
18
1
TEX
memory attribute
19
3
AP
Access permission
24
3
XN
Instruction access disable
bit
28
1
STK
SysTick timer
STK
0xE000E010
0x0
0x11
registers
CTRL
CTRL
SysTick control and status
register
0x0
0x20
read-write
0X00000000
ENABLE
Counter enable
0
1
TICKINT
SysTick exception request
enable
1
1
CLKSOURCE
Clock source selection
2
1
COUNTFLAG
COUNTFLAG
16
1
LOAD
LOAD
SysTick reload value register
0x4
0x20
read-write
0X00000000
RELOAD
RELOAD value
0
24
VAL
VAL
SysTick current value register
0x8
0x20
read-write
0X00000000
CURRENT
Current counter value
0
24
CALIB
CALIB
SysTick calibration value
register
0xC
0x20
read-write
0X00000000
TENMS
Calibration value
0
24
SKEW
SKEW flag: Indicates whether the TENMS
value is exact
30
1
NOREF
NOREF flag. Reads as zero
31
1
SCB
System control block
SCB
0xE000ED00
0x0
0x41
registers
CPUID
CPUID
CPUID base register
0x0
0x20
read-only
0x410FC241
Revision
Revision number
0
4
PartNo
Part number of the
processor
4
12
Constant
Reads as 0xF
16
4
Variant
Variant number
20
4
Implementer
Implementer code
24
8
ICSR
ICSR
Interrupt control and state
register
0x4
0x20
read-write
0x00000000
VECTACTIVE
Active vector
0
9
RETTOBASE
Return to base level
11
1
VECTPENDING
Pending vector
12
7
ISRPENDING
Interrupt pending flag
22
1
PENDSTCLR
SysTick exception clear-pending
bit
25
1
PENDSTSET
SysTick exception set-pending
bit
26
1
PENDSVCLR
PendSV clear-pending bit
27
1
PENDSVSET
PendSV set-pending bit
28
1
NMIPENDSET
NMI set-pending bit.
31
1
VTOR
VTOR
Vector table offset register
0x8
0x20
read-write
0x00000000
TBLOFF
Vector table base offset
field
9
21
AIRCR
AIRCR
Application interrupt and reset control
register
0xC
0x20
read-write
0x00000000
VECTRESET
VECTRESET
0
1
VECTCLRACTIVE
VECTCLRACTIVE
1
1
SYSRESETREQ
SYSRESETREQ
2
1
PRIGROUP
PRIGROUP
8
3
ENDIANESS
ENDIANESS
15
1
VECTKEYSTAT
Register key
16
16
SCR
SCR
System control register
0x10
0x20
read-write
0x00000000
SLEEPONEXIT
SLEEPONEXIT
1
1
SLEEPDEEP
SLEEPDEEP
2
1
SEVEONPEND
Send Event on Pending bit
4
1
CCR
CCR
Configuration and control
register
0x14
0x20
read-write
0x00000000
NONBASETHRDENA
Configures how the processor enters
Thread mode
0
1
USERSETMPEND
USERSETMPEND
1
1
UNALIGN__TRP
UNALIGN_ TRP
3
1
DIV_0_TRP
DIV_0_TRP
4
1
BFHFNMIGN
BFHFNMIGN
8
1
STKALIGN
STKALIGN
9
1
SHPR1
SHPR1
System handler priority
registers
0x18
0x20
read-write
0x00000000
PRI_4
Priority of system handler
4
0
8
PRI_5
Priority of system handler
5
8
8
PRI_6
Priority of system handler
6
16
8
SHPR2
SHPR2
System handler priority
registers
0x1C
0x20
read-write
0x00000000
PRI_11
Priority of system handler
11
24
8
SHPR3
SHPR3
System handler priority
registers
0x20
0x20
read-write
0x00000000
PRI_14
Priority of system handler
14
16
8
PRI_15
Priority of system handler
15
24
8
SHCRS
SHCRS
System handler control and state
register
0x24
0x20
read-write
0x00000000
MEMFAULTACT
Memory management fault exception active
bit
0
1
BUSFAULTACT
Bus fault exception active
bit
1
1
USGFAULTACT
Usage fault exception active
bit
3
1
SVCALLACT
SVC call active bit
7
1
MONITORACT
Debug monitor active bit
8
1
PENDSVACT
PendSV exception active
bit
10
1
SYSTICKACT
SysTick exception active
bit
11
1
USGFAULTPENDED
Usage fault exception pending
bit
12
1
MEMFAULTPENDED
Memory management fault exception
pending bit
13
1
BUSFAULTPENDED
Bus fault exception pending
bit
14
1
SVCALLPENDED
SVC call pending bit
15
1
MEMFAULTENA
Memory management fault enable
bit
16
1
BUSFAULTENA
Bus fault enable bit
17
1
USGFAULTENA
Usage fault enable bit
18
1
CFSR_UFSR_BFSR_MMFSR
CFSR_UFSR_BFSR_MMFSR
Configurable fault status
register
0x28
0x20
read-write
0x00000000
IACCVIOL
Instruction access violation
flag
1
1
MUNSTKERR
Memory manager fault on unstacking for a
return from exception
3
1
MSTKERR
Memory manager fault on stacking for
exception entry.
4
1
MLSPERR
MLSPERR
5
1
MMARVALID
Memory Management Fault Address Register
(MMAR) valid flag
7
1
IBUSERR
Instruction bus error
8
1
PRECISERR
Precise data bus error
9
1
IMPRECISERR
Imprecise data bus error
10
1
UNSTKERR
Bus fault on unstacking for a return
from exception
11
1
STKERR
Bus fault on stacking for exception
entry
12
1
LSPERR
Bus fault on floating-point lazy state
preservation
13
1
BFARVALID
Bus Fault Address Register (BFAR) valid
flag
15
1
UNDEFINSTR
Undefined instruction usage
fault
16
1
INVSTATE
Invalid state usage fault
17
1
INVPC
Invalid PC load usage
fault
18
1
NOCP
No coprocessor usage
fault.
19
1
UNALIGNED
Unaligned access usage
fault
24
1
DIVBYZERO
Divide by zero usage fault
25
1
HFSR
HFSR
Hard fault status register
0x2C
0x20
read-write
0x00000000
VECTTBL
Vector table hard fault
1
1
FORCED
Forced hard fault
30
1
DEBUG_VT
Reserved for Debug use
31
1
MMFAR
MMFAR
Memory management fault address
register
0x34
0x20
read-write
0x00000000
MMFAR
Memory management fault
address
0
32
BFAR
BFAR
Bus fault address register
0x38
0x20
read-write
0x00000000
BFAR
Bus fault address
0
32
AFSR
AFSR
Auxiliary fault status
register
0x3C
0x20
read-write
0x00000000
IMPDEF
Implementation defined
0
32
NVIC_STIR
Nested vectored interrupt
controller
NVIC
0xE000EF00
0x0
0x5
registers
STIR
STIR
Software trigger interrupt
register
0x0
0x20
read-write
0x00000000
INTID
Software generated interrupt
ID
0
9
FPU_CPACR
Floating point unit CPACR
FPU
0xE000ED88
0x0
0x5
registers
CPACR
CPACR
Coprocessor access control
register
0x0
0x20
read-write
0x0000000
CP
CP
20
4
SCB_ACTRL
System control block ACTLR
SCB
0xE000E008
0x0
0x5
registers
ACTRL
ACTRL
Auxiliary control register
0x0
0x20
read-write
0x00000000
DISMCYCINT
DISMCYCINT
0
1
DISDEFWBUF
DISDEFWBUF
1
1
DISFOLD
DISFOLD
2
1
DISFPCA
DISFPCA
8
1
DISOOFP
DISOOFP
9
1