# angle_style hybrid command ## Syntax ``` LAMMPS angle_style hybrid style1 style2 ... ``` - style1,style2 = list of one or more angle styles ## Examples ``` LAMMPS angle_style hybrid harmonic cosine angle_coeff 1 harmonic 80.0 30.0 angle_coeff 2* cosine 50.0 ``` ## Description The *hybrid* style enables the use of multiple angle styles in one simulation. An angle style is assigned to each angle type. For example, angles in a polymer flow (of angle type 1) could be computed with a *harmonic* potential and angles in the wall boundary (of angle type 2) could be computed with a *cosine* potential. The assignment of angle type to style is made via the [angle_coeff](angle_coeff) command or in the data file. In the [angle_coeff](angle_coeff) commands, the name of an angle style must be added after the angle type, with the remaining coefficients being those appropriate to that style. In the example above, the 2 angle_coeff commands set angles of angle type 1 to be computed with a *harmonic* potential with coefficients 80.0, 30.0 for $K$, $\theta_0$. All other angle types $(2 - N)$ are computed with a *cosine* potential with coefficient 50.0 for $K$. If angle coefficients are specified in the data file read via the [read_data](read_data) command, then the same rule applies. E.g. \"harmonic\" or \"cosine\", must be added after the angle type, for each line in the \"Angle Coeffs\" section, e.g. Angle Coeffs 1 harmonic 80.0 30.0 2 cosine 50.0 ... If *class2* is one of the angle hybrid styles, the same rule holds for specifying additional BondBond (and BondAngle) coefficients either via the input script or in the data file. I.e. *class2* must be added to each line after the angle type. For lines in the BondBond (or BondAngle) section of the data file for angle types that are not *class2*, you must use an angle style of *skip* as a placeholder, e.g. BondBond Coeffs 1 skip 2 class2 3.6512 1.0119 1.0119 ... Note that it is not necessary to use the angle style *skip* in the input script, since BondBond (or BondAngle) coefficients need not be specified at all for angle types that are not *class2*. An angle style of *none* with no additional coefficients can be used in place of an angle style, either in a input script [angle_coeff](angle_coeff) command or in the data file, if you desire to turn off interactions for specific angle types. ------------------------------------------------------------------------ ## Restrictions This angle style can only be used if LAMMPS was built with the MOLECULE package. See the [Build package](Build_package) doc page for more info. Unlike other angle styles, the hybrid angle style does not store angle coefficient info for individual sub-styles in a [binary restart files](restart). Thus when restarting a simulation from a restart file, you need to re-specify [angle_coeff](angle_coeff) commands. ## Related commands [angle_coeff](angle_coeff) ## Default none