Which value of the Sensor Binary Report will be sent when
the Sensor is triggered On.
Enable/disable wake up 10 minutes when re-power on the
Sensor.
Which value of the Basic Report will be sent when
the Sensor is triggered On.
Set the low battery value.
Set the interval time of battery report.
Value=0, disable the battery report for a interval time.
Value=1 to 0x7FFFFFFF, the interval time of battery report is
set.
Note:
1, if the value is less than 10, the time unit is second.
If the value is more than 10, the time unit is 4 minutes, which
means if the value is more than 10 and less than 240, the
interval time is 4 minutes. If the value is more than 240 and
less than 480, the interval is 8 minutes.
2, if the current battery report falls below the low battery
value (configurable parameter 39), it will send battery
report=0xFF.
Defines the type of report sent.
Value 1 (msb) Reserved
Value 2 Reserved
Value 3 bits 7-1 reserved
bits 0 - Basic Report
Value 4 (lsb) bits 7-4 reserved
bit 3 Sensor Binary
bit 2-0 reserved
Reset to the default configuration.