Voltage to calculate wattage from amperage. US=120. EU,ANZ=240.
Automatic report only when power is changed.
Threshold change in wattage to induce a automatic report (whole HEM).
Threshold change in wattage to induce a automatic report (Clamp 1).
Threshold change in wattage to induce a automatic report (Clamp 2).
Threshold change in wattage to induce a automatic report (Clamp 3).
Percentage change in wattage to induce a automatic report (whole HEM).
Percentage change in wattage to induce a automatic report (Clamp 1).
Percentage change in wattage to induce a automatic report (Clamp 2).
Percentage change in wattage to induce a automatic report (Clamp 3).
Accumulate energy when Battery Powered.
This byte denotes whether the product is using batteries (value = 0) or using USB power (value = 1).
Reset to default parameters number 101-103. Any value other then 0 will initiate this reset.
Which reports need to send in group1. Format is as follows:
Byte 1 (msb): Reserved
Byte 2: Reserved
Byte 3: Bit 7: reserved
Bit 6: reserved
Bit 5: Auto Send Meter Report (for kWh) at the group time interval (Clamp 3)
Bit 4: Auto Send Meter Report (for kWh) at the group time interval (Clamp 2)
Bit 3: Auto Send Meter Report (for kWh) at the group time interval (Clamp 1)
Bit 2: Auto Send Meter Report (for watts) at the group time interval (Clamp 3)
Bit 1: Auto Send Meter Report (for watts) at the group time interval (Clamp 2)
Bit 0: Auto Send Meter Report (for watts) at the group time interval (Clamp 1)
Byte 4 (lsb): Bit 7: reserved
Bit 6: reserved
Bit 5: reserved
Bit 4: reserved
Bit 3: Auto Send Meter Report (for kWh) at the group time interval (whole HEM)
Bit 2: Auto Send Meter Report (for watts) at the group time interval (whole HEM)
Bit 1: Auto Send Multilevel Sensor Report (for watts) at the group time interval (whole HEM)
Bit 0: Auto Send Battery Report at the group time interval (whole HEM)
Which reports need to send in group2. Format is as follows:
Byte 1 (msb): Reserved
Byte 2: Reserved
Byte 3: Bit 7: reserved
Bit 6: reserved
Bit 5: Auto Send Meter Report (for kWh) at the group time interval (Clamp 3)
Bit 4: Auto Send Meter Report (for kWh) at the group time interval (Clamp 2)
Bit 3: Auto Send Meter Report (for kWh) at the group time interval (Clamp 1)
Bit 2: Auto Send Meter Report (for watts) at the group time interval (Clamp 3)
Bit 1: Auto Send Meter Report (for watts) at the group time interval (Clamp 2)
Bit 0: Auto Send Meter Report (for watts) at the group time interval (Clamp 1)
Byte 4 (lsb): Bit 7: reserved
Bit 6: reserved
Bit 5: reserved
Bit 4: reserved
Bit 3: Auto Send Meter Report (for kWh) at the group time interval (whole HEM)
Bit 2: Auto Send Meter Report (for watts) at the group time interval (whole HEM)
Bit 1: Auto Send Multilevel Sensor Report (for watts) at the group time interval (whole HEM)
Bit 0: Auto Send Battery Report at the group time interval (whole HEM)
Which reports need to send in group3. Format is as follows:
Byte 1 (msb): Reserved
Byte 2: Reserved
Byte 3: Bit 7: reserved
Bit 6: reserved
Bit 5: Auto Send Meter Report (for kWh) at the group time interval (Clamp 3)
Bit 4: Auto Send Meter Report (for kWh) at the group time interval (Clamp 2)
Bit 3: Auto Send Meter Report (for kWh) at the group time interval (Clamp 1)
Bit 2: Auto Send Meter Report (for watts) at the group time interval (Clamp 3)
Bit 1: Auto Send Meter Report (for watts) at the group time interval (Clamp 2)
Bit 0: Auto Send Meter Report (for watts) at the group time interval (Clamp 1)
Byte 4 (lsb): Bit 7: reserved
Bit 6: reserved
Bit 5: reserved
Bit 4: reserved
Bit 3: Auto Send Meter Report (for kWh) at the group time interval (whole HEM)
Bit 2: Auto Send Meter Report (for watts) at the group time interval (whole HEM)
Bit 1: Auto Send Multilevel Sensor Report (for watts) at the group time interval (whole HEM)
Bit 0: Auto Send Battery Report at the group time interval (whole HEM)
Reset to default parameters number 111-113. Any value other then 0 will initiate this reset.
The interval of sending report group 1.
The interval of sending report group 2.
The interval of sending report group 3.
Re-calibrate (will destroy factory calibration). CONTACT AEON LABS before using.
Device tag.
Reset to the default configuration.