If the reverse clamping pliers, negative power is detected.
Automatic report only when power is changed.
Threshold change in wattage to induce a automatic report (whole HEM).
Threshold change in wattage to induce a automatic report (Clamp 1).
Threshold change in wattage to induce a automatic report (Clamp 2).
Threshold change in wattage to induce a automatic report (Clamp 3).
Percentage change in wattage to induce a automatic report (whole HEM).
Percentage change in wattage to induce a automatic report (Clamp 1).
Percentage change in wattage to induce a automatic report (Clamp 2).
Percentage change in wattage to induce a automatic report (Clamp 3).
Reset to default parameters number 101-103. Any value other then 0 will initiate this reset.
Which reports need to send in group1. Format is as follows:
Byte 1 (msb): Reserved
Byte 2: Reserved
Byte 3: Bit 7: reserved
Bit 6: reserved
Bit 5: Auto Send Meter Report (for kWh) at the group time interval (Clamp 3)
Bit 4: Auto Send Meter Report (for kWh) at the group time interval (Clamp 2)
Bit 3: Auto Send Meter Report (for kWh) at the group time interval (Clamp 1)
Bit 2: Auto Send Meter Report (for watts) at the group time interval (Clamp 3)
Bit 1: Auto Send Meter Report (for watts) at the group time interval (Clamp 2)
Bit 0: Auto Send Meter Report (for watts) at the group time interval (Clamp 1)
Byte 4 (lsb): Bit 7: reserved
Bit 6: reserved
Bit 5: reserved
Bit 4: reserved
Bit 3: Auto Send Meter Report (for kWh) at the group time interval (whole HEM)
Bit 2: Auto Send Meter Report (for watts) at the group time interval (whole HEM)
Bit 1: Auto Send Multilevel Sensor Report (for watts) at the group time interval (whole HEM)
Bit 0: Auto Send Battery Report at the group time interval (whole HEM)
Which reports need to send in group2. Format is as follows:
Byte 1 (msb): Reserved
Byte 2: Reserved
Byte 3: Bit 7: reserved
Bit 6: reserved
Bit 5: Auto Send Meter Report (for kWh) at the group time interval (Clamp 3)
Bit 4: Auto Send Meter Report (for kWh) at the group time interval (Clamp 2)
Bit 3: Auto Send Meter Report (for kWh) at the group time interval (Clamp 1)
Bit 2: Auto Send Meter Report (for watts) at the group time interval (Clamp 3)
Bit 1: Auto Send Meter Report (for watts) at the group time interval (Clamp 2)
Bit 0: Auto Send Meter Report (for watts) at the group time interval (Clamp 1)
Byte 4 (lsb): Bit 7: reserved
Bit 6: reserved
Bit 5: reserved
Bit 4: reserved
Bit 3: Auto Send Meter Report (for kWh) at the group time interval (whole HEM)
Bit 2: Auto Send Meter Report (for watts) at the group time interval (whole HEM)
Bit 1: Auto Send Multilevel Sensor Report (for watts) at the group time interval (whole HEM)
Bit 0: Auto Send Battery Report at the group time interval (whole HEM)
Which reports need to send in group3. Format is as follows:
Byte 1 (msb): Reserved
Byte 2: Reserved
Byte 3: Bit 7: reserved
Bit 6: reserved
Bit 5: Auto Send Meter Report (for kWh) at the group time interval (Clamp 3)
Bit 4: Auto Send Meter Report (for kWh) at the group time interval (Clamp 2)
Bit 3: Auto Send Meter Report (for kWh) at the group time interval (Clamp 1)
Bit 2: Auto Send Meter Report (for watts) at the group time interval (Clamp 3)
Bit 1: Auto Send Meter Report (for watts) at the group time interval (Clamp 2)
Bit 0: Auto Send Meter Report (for watts) at the group time interval (Clamp 1)
Byte 4 (lsb): Bit 7: reserved
Bit 6: reserved
Bit 5: reserved
Bit 4: reserved
Bit 3: Auto Send Meter Report (for kWh) at the group time interval (whole HEM)
Bit 2: Auto Send Meter Report (for watts) at the group time interval (whole HEM)
Bit 1: Auto Send Multilevel Sensor Report (for watts) at the group time interval (whole HEM)
Bit 0: Auto Send Battery Report at the group time interval (whole HEM)
Reset to default parameters number 111-113. Any value other then 0 will initiate this reset.
The interval of sending report group 1.
The interval of sending report group 2.
The interval of sending report group 3.
Device tag.
Reset to the default configuration.