This is actually a double byte value. The LSB defines the total time the device needs to blink in seconds. The MSB defines the on/off interval of the blink in tenths of seconds.
Current Overload Protection. Load will be closed when 3
the Current more than 2.7A and the time more than 2
minutes
Enables automatic notifications to associated devices whenever there is a state change.
Enable/disable Wattage threshold and percent.
The minimum change in wattage for a report to be sent.
Minimum change in percent of wattage to send a report.
Set report types for groups 1, 2 and 3 to default. Reverts to 0
after set.
Defines the type of report sent for reporting group 1. 2 is multisensor report. 4 is meter report for watts. 8 is meter report for kilowatts.
Value 1 (msb) Reserved
Value 2 Reserved
Value 3 Reserved
Value 4 (lsb) bits 7-4 reserved
bit 3 MRC (KWH)
bit 2 MRC (watt)
bit 1 MSRC (Current)
bit 0 MRC (Voltage)
The MRC(KWH) flag signals that Report Group 1 send(1) or don't send(0)
Meter Report Command(KWh) automatically.
The MRC(Watt) flag signals that Report Group 1 send(1) or don't send(0)
Meter Report Command(wattage) automatically.
The MSRC flag signals that Report Group 1 send(1) or don't send(0)
Multilevel Sensor Report Command(wattage) automatically.
Defines the type of report sent for reporting group 2. 2 is multisensor report. 4 is meter report for watts. 8 is meter report for kilowatts.
Value 1 (msb) Reserved
Value 2 Reserved
Value 3 Reserved
Value 4 (lsb) bits 7-4 reserved
bit 3 MRC (KWH)
bit 2 MRC (watt)
bit 1 MSRC (Current)
bit 0 MRC (Voltage)
The MRC(KWH) flag signals that Report Group 1 send(1) or don't send(0)
Meter Report Command(KWh) automatically.
The MRC(Watt) flag signals that Report Group 1 send(1) or don't send(0)
Meter Report Command(wattage) automatically.
The MSRC flag signals that Report Group 1 send(1) or don't send(0)
Multilevel Sensor Report Command(wattage) automatically.
Defines the type of report sent for reporting group 3. 2 is multisensor report. 4 is meter report for watts. 8 is meter report for kilowatts.
Value 1 (msb) Reserved
Value 2 Reserved
Value 3 Reserved
Value 4 (lsb) bits 7-4 reserved
bit 3 MRC (KWH)
bit 2 MRC (watt)
bit 1 MSRC (Current)
bit 0 MRC (Voltage)
The MRC(KWH) flag signals that Report Group 1 send(1) or don't send(0)
Meter Report Command(KWh) automatically.
The MRC(Watt) flag signals that Report Group 1 send(1) or don't send(0)
Meter Report Command(wattage) automatically.
The MSRC flag signals that Report Group 1 send(1) or don't send(0)
Multilevel Sensor Report Command(wattage) automatically.
Set time interval for sending reports for groups 1, 2 and 3 to default.
Defines the time interval when the defined report for group 1 is sent.
Defines the time interval when the defined report for group 2 is sent.
Defines the time interval when the defined report for group 3 is sent.
Turn external button mode
Device tag.
Reset to the default configuration.