Defines the contents of Multilevel Sensor Report after Multilevel Sensor Get received. This is actually a double byte value. The LSB defines the total time the device needs to blink in seconds. The MSB defines the on/off interval of the blink in tenths of seconds. Enables automatic notifications to associated devices whenever there is a state change. Enable/disable Wattage threshold and percent. The minimum change in wattage for a report to be sent. Minimum change in percent of wattage to send a report. Set report types for groups 1, 2 and 3 to default. Reverts to 0 after set. Defines the type of report sent for reporting group 1. 2 is multisensor report. 4 is meter report for watts. 8 is meter report for kilowatts. Value 1 (msb) Reserved Value 2 Reserved Value 3 Reserved Value 4 (lsb) bits 7-4 reserved bit 3 MRC(KWH) bit 2 MRC(watt) bit 1 MSRC bit 0 reserved The MRC(KWH) flag signals that Report Group 1 send(1) or don't send(0) Meter Report Command(KWh) automatically. The MRC(Watt) flag signals that Report Group 1 send(1) or don't send(0) Meter Report Command(wattage) automatically. The MSRC flag signals that Report Group 1 send(1) or don't send(0) Multilevel Sensor Report Command(wattage) automatically. Defines the type of report sent for reporting group 2. 2 is multisensor report. 4 is meter report for watts. 8 is meter report for kilowatts. Value 1 (msb) Reserved Value 2 Reserved Value 3 Reserved Value 4 (lsb) bits 7-4 reserved bit 3 MRC(KWH) bit 2 MRC(watt) bit 1 MSRC bit 0 reserved The MRC(KWH) flag signals that Report Group 1 send(1) or don't send(0) Meter Report Command(KWh) automatically. The MRC(Watt) flag signals that Report Group 1 send(1) or don't send(0) Meter Report Command(wattage) automatically. The MSRC flag signals that Report Group 1 send(1) or don't send(0) Multilevel Sensor Report Command(wattage) automatically. Defines the type of report sent for reporting group 3. 2 is multisensor report. 4 is meter report for watts. 8 is meter report for kilowatts. Value 1 (msb) Reserved Value 2 Reserved Value 3 Reserved Value 4 (lsb) bits 7-4 reserved bit 3 MRC(KWH) bit 2 MRC(watt) bit 1 MSRC bit 0 reserved The MRC(KWH) flag signals that Report Group 1 send(1) or don't send(0) Meter Report Command(KWh) automatically. The MRC(Watt) flag signals that Report Group 1 send(1) or don't send(0) Meter Report Command(wattage) automatically. The MSRC flag signals that Report Group 1 send(1) or don't send(0) Multilevel Sensor Report Command(wattage) automatically. Set time interval for sending reports for groups 1, 2 and 3 to default. Defines the time interval when the defined report for group 1 is sent. Defines the time interval when the defined report for group 2 is sent. Defines the time interval when the defined report for group 3 is sent. Device tag. Reset to the default configuration.