Configuration Value 1: 1‐255 Configuration Value 1 is to Specify the time that Smart Switch need blink, The unit is Second; Configuration Value 2: 1‐255 Configuration Value 2 is to Specify the Cycle of on/off, the unit of it is 0.1 second. Load will be closed when the Current overruns (EU 16.2A) for more than 2 minutes Configure the output load status after re-power on. Defines the automated status notification of an associated device when status changes Enable/disable Wattage threshold and percent. The value represents the minimum change in wattage for a Report to be sent (default 25 W) The value represents the minimum percentage change in wattage for a Report to be sent (Default 5) Set report types for groups 1, 2 and 3 to default. Defines the type of report sent for reporting group 1. 2 is multisensor report. 4 is meter report for watts. 8 is meter report for kilowatts. Value 1 (msb) Reserved Value 2 Reserved Value 3 Reserved Value 4 (lsb) bits 7-4 reserved bit 3 MRC(KWH) bit 2 MRC(watt) bit 1 MSRC bit 0 reserved The MRC(KWH) flag signals that Report Group 1 send(1) or don't send(0) Meter Report Command(KWh) automatically. The MRC(Watt) flag signals that Report Group 1 send(1) or don't send(0) Meter Report Command(wattage) automatically. The MSRC flag signals that Report Group 1 send(1) or don't send(0) Multilevel Sensor Report Command(wattage) automatically. Defines the type of report sent for reporting group 2. 2 is multisensor report. 4 is meter report for watts. 8 is meter report for kilowatts. Value 1 (msb) Reserved Value 2 Reserved Value 3 Reserved Value 4 (lsb) bits 7-4 reserved bit 3 MRC(KWH) bit 2 MRC(watt) bit 1 MSRC bit 0 reserved The MRC(KWH) flag signals that Report Group 1 send(1) or don't send(0) Meter Report Command(KWh) automatically. The MRC(Watt) flag signals that Report Group 1 send(1) or don't send(0) Meter Report Command(wattage) automatically. The MSRC flag signals that Report Group 1 send(1) or don't send(0) Multilevel Sensor Report Command(wattage) automatically. Defines the type of report sent for reporting group 3. 2 is multisensor report. 4 is meter report for watts. 8 is meter report for kilowatts. Value 1 (msb) Reserved Value 2 Reserved Value 3 Reserved Value 4 (lsb) bits 7-4 reserved bit 3 MRC(KWH) bit 2 MRC(watt) bit 1 MSRC bit 0 reserved The MRC(KWH) flag signals that Report Group 1 send(1) or don't send(0) Meter Report Command(KWh) automatically. The MRC(Watt) flag signals that Report Group 1 send(1) or don't send(0) Meter Report Command(wattage) automatically. The MSRC flag signals that Report Group 1 send(1) or don't send(0) Multilevel Sensor Report Command(wattage) automatically. Set time interval for sending reports for groups 1, 2 and 3 to default. Defines the time interval when the defined report for group 1 is sent. Defines the time interval when the defined report for group 2 is sent. Defines the time interval when the defined report for group 3 is sent. Partner ID Enable/disable Configuration Locked Device tag. Reset to the default configuration.