Setting the BASIC command value to turn on the light. The 0xFF (-1) means turn on the light.
For dimmer equipment 1 to 100 means the light strength. 0 means turn off the light.
Setting the illummination threshold to turn on the light. When the event triggered and the environment illumination lower then
the threshold, the device will turn on the light.
0 means turn off illumination detected function and never turn on the light.
1 means darkest.
99 means brightest.
100 means turn off illumination detected function. And always turn on the light.
* Notice * in none test mode, only the value in 1 to 99 will enable the illumination detected function and update the illumination value.
Bit 0: Reserved
Bit 1: Reserved
Bit 2: Disable the door/window function (1: Disable, 0: Enable).
Bit 3: Setting the temperature scale. 0: Fahrenheit, 1:Celsius.
Bit 4: Disable the illumination report after event triggered (1: Disable, 0: Enable).
Bit 5: Disable the temperature report after event triggered (1: Disable, 0: Enable).
Multi-Sensor Function switch. Using bit to control.
Bit 0: Disable magnetic integrate illumination to turn ON the lighting nodes in the association group 2 (1: Disable, 0: Enable).
Bit 1: Reserved always 1
Bit 2: Reserved always 1
Bit 3: Reserved
Bit 4: Disable delay 5 seconds to turn off the light, when door/window closed.
Bit 5: Disable auto turn off the light, after door/window opened to turn on the light. Notice: If bit2 is zero, this setting is useless. Notice: If the configuration No.9 is zero, this setting is useless.
Bit 6: Enable temperature monitoring. When this bit enabled the temperature changed 3 degree Fahrenheit. It will report. And also temp above 140 it will report every 64 seconds.
Customer function switch, using bit control.
Bit 0: Reserve.
Bit 1: Enable sending motion OFF report. Note: Depends on the Bit4, 0: Report Notification CC, Type: 0x07, Event: 0xFE 1: Sensor Binary Report, Type: 0x0C, Value: 0x00.
Bit 2: Enable PIR super sensitivity mode.
Bit 3: Enable don't send out BASIC OFF after door closed.
Bit 4: Notification Type, 0: Using Notification Report. 1: Using Sensor Binary Report.
Bit 5: Disable Multi CC in auto report.
Bit 6: Disable to report battery state when the device triggered.
Bit 7: Reserve.
After turn on the lighting, setting the delay time to turn off the lighting when the PIR motion is not detected.
8 seconds per tick, default tick is 4 (32 seconds). 0 means never send turn off light command.
The interval time for auto report the battery level. 0 means turn off auto report battery. The default value is 12. The tick time can setting by the configuration No.20.
The interval time for auto report the door/window state. 0 means turn off auto report door/window state. The default value is 12. The tick time can setting by the configuration No.20.
The interval time for auto report the illumination. 0 means turn off auto report illumination. The default value is 12. The tick time can setting by the configuration No.20.
The interval time for auto report the temperature. 0 means turn off auto report temperature. The default value is 12. The tick time can setting by the configuration No.20.
The interval time for auto report each tick. Setting this configuration will effect configuration No.10, No.11, No.12 and No.13. Caution: Setting to 0 means turn off all auto report function.
The temperature differential to report. 0 means turn off this function. The unit is Fahrenheit. Enable this function the device will detect every minutes. And when the temperature is over 140 degree Fahrenheit, it will continue report. Enable this functionality will cause some issue please see the detail in the "Temperature Report" section.
The illumination differential to report.0 means turn off this function. The unit is percentage. Enable this function the device will detect every minutes. Enable this functionality will cause some issue please see the detail in the "Illumination Report" section.