Set the BASIC command value to turn on the light. 255: always turn on the light. For dimmer equipment 1 to 100 means the light strength. 0 means turn off the light. PIR sensitivity settings. 0 means disable the PIR motion. 1 means the lowest sensitivity. 99 means the highest sensitivity. High sensitivity means the sensor can detect over a long distance, but if there is more noise signal in the environment, it will re-trigger too frequently. Set the illumination threshold to turn on the light. When the event is triggered and the environment illumination is lower than the threshold, the device will turn on the light. 0 means turn off illumination detected function and never turn on the light. 1 means darkest. 99 means brightest. 100 means turn off illumination detected function. And always turn on the light. * Notice * in none test mode, only the value in 1 to 99 will enable the illumination detected function and update the illumination value. Bit 0: Reserved Bit 1: 1 means test mode, 0 means normal mode. Notice: This bit only effect by the DIP Switch setting to “customer mode”, otherwise it decides by DIP Switch setting to Test or Normal Mode. Bit 2: Reserved Bit 3: Setting the temperature scale. 0: Fahrenheit, 1:Celsius. Bit 4: Disable the illumination report after event triggered (1: Disable, 0: Enable). Bit 5: Disable the temperature report after event triggered (1: Disable, 0: Enable). Bit 6: Reserved. Bit 7: Disable the back key release into test mode. (1: Disable, 0: Enable) Note: All default to 0. Multi-Sensor Function switch. Using bit to control. Bit 0: Reserved. (Default: 0) Bit 1: Disable PIR integrate Illumination to turn ON the lighting nodes in the association group 2. (1:Disable, 0:Enable) (Default: 0) Bit 2: Reserved always 1 Bit 3: Reserved always 0 Bit 4: Reserved always 0 Bit 5: Reserved always 0 Bit 6: Reserved always 0 Bit 7: Reserved always 0 Customer function switch, using bit control. Bit 0: Reserved always 0. Bit 1: Enable sending motion OFF report. Note: Depends on the Bit4, 0: Report Notification CC, Type: 0x07, Event: 0xFE 1: Sensor Binary Report, Type: 0x0C, Value: 0x00. (Default: 0) Bit 2: Enable PIR super sensitivity mode. (Default: 1) Bit 3: Reserved always 0 Bit 4: Notification Type, 0: Using Notification Report. 1: Using Sensor Binary Report. (Default: 0) Bit 5: Disable Multi CC in auto report. (Default: 0) Bit 6: Disable to report battery state when the device triggered. (1:Disable, 0:Enable) (Default: 0) Bit 7: Reserved always 0. In the normal mode, after the PIR motion detected, setting the re-detect time. 8 seconds per tick, default tick is 3 (24 seconds). Set a suitable value to prevent receiving the trigger signal too frequently. Also can save the battery energy. Notice: If this value bigger than the configuration setting NO. 9 there will be a period after the light turned off where the PIR is not detecting. After turn on the lighting, setting the delay time to turn off the lighting when the PIR motion is not detected. 8 seconds per tick, default tick is 4 (32 seconds). 0 means never send turn off light command. The interval time for auto report the battery level. 0 means turn off auto report battery. The default value is 12. The tick time can be set by the configuration No.20. The interval time for auto reporting of the illumination. 0 means turn off auto report illumination. The default value is 12. The tick time can be set by the configuration No.20. The interval time for auto report the temperature. 0 means turn off auto report temperature. The default value is 12. The tick time can be set by the configuration No.20. The interval time for auto report each tick. Setting this configuration will effect configuration No.10, No.11, No.12 and No.13. Caution: Setting to 0 means turn off all auto report function. Default is 30 minutes The temperature differential to report. 0 means turn off this function. The unit is Fahrenheit. Enable this function the device will detect every minutes. And when the temperature is over 140 degree Fahrenheit, it will continue report. Enable this functionality will cause some issue please see the detail in the "Temperature Report" section. The illumination differential to report.0 means turn off this function. The unit is percentage. Enable this function the device will detect every minutes. Enable this functionality will cause some issue please see the detail in the "Illumination Report" section.