Flood alarm cancellation delay. Additional delay after a flood alarm has ceased. The parameter allows you to specify additional time, after which the flood alarm is cancelled once its violation has ceased. Acoustic and visual signals in case of flooding. Type of alarm frame for association group 1, activated by flood sensor. The parameter allows to specify the type of alarm frame or to force transmission of control commands (BASIC_SET) Value of the parameter specifying the forced level of dimming / opening sun blinds when comes "switch on" / "open" command to devices from association group no. 1. In the case of alarm frames the alarm priority is specified. Possible parameter settings: (1 – 99) and 255. Value of 255 makes it possible to activate the device when using the Dimmer module it means activating the device and setting it to the previous stored condition, e.g. when Dimmer is set to 30%, then deactivated, and then reactivated using command 255, it will automatically be set to the previous condition, i.e. 30%. Deactivating transmission of the frame cancelling the alarm or the control frame deactivating the device (Basic). It allows for disabling the deactivation function or the alarm cancellation function for devices associated with the appropriate input of the Fibaro Sensor. NOTE: Information concerning alarm violation or activation commands for devices from association groups are always sent. Interval between successive readings of temperature from all sensors connected to the device in seconds. Note: taking temperature readings from the sensor does not result in sending a temperature condition report to the central hub. Insensitiveness to temperature changes. This is the maximum acceptable difference between the last reported temperature and the current temperature taken from the sensor. If the temperatures differ by the set value or more, then a report with the current temperature value is sent to the device assigned to association group no. 3. Intervals between taking readings from sensors are specified by parameter no. 10. Possible parameter settings:1 – 1000 [each 0.01oC] [0.01oC – 10.00oC]. Transmitting the alarm or control frame in "broadcast" mode (i.e. to all devices within range), information sent in this mode is not repeated by the mesh network. NOTE: If the broadcast mode of information transmission is activated for a given channel, then transmission of information in singlecast mode to devices assigned to the association group of this channel is deactivated. The parameter stores a temperature value, below which LED indicator blinks with a colour determined by Parameter 61 settings. By default the LED indicator blinks blue. Possible parameter settings:-10000 – 10000 [each 0.01oC] [-100oC – 100oC]. The parameter stores a temperature value, above which LED indicator blinks with a colour determined by Parameter 62 settings. By default the LED indicator blinks red. Possible parameter settings:-10000 – 10000 [each 0.01oC] [-100oC – 100oC]. The parameter stores RGB colour value. The parameter stores RGB colour value. Parameter determines LED indicator's operation. Set to 0 turns the indicator off, saving battery life. Parameter stores a temperature value to be added to or deducted from the current temperature measured by the internal temperature sensor in order to compensate the difference between air temperature and the temperature at floor level. Possible parameter settings:-10000 – 10000 [each 0.01oC] [-100oC – 100oC]. The device is able to turn on alarms resulting from sensors vibrations, e.g. when the sensor is moved, or the TMP button is released. Group 2 association alarms are not cancelled. Parameter determines a time period after which alarm will become 'quiet' - still active but the device will go into battery saving mode. Visual or acoustic alarm will be reactivated after time period specified in Parameter 76. When alarm status ceases, alarm will be turned off immediately. Value of 0 means visual and acoustic alarms are active indefinitely. In battery power mode the device will never go to sleep which may shorten battery life significantly. Parameter determines a time period after which an alarm frame will be retransmitted. Value of 0 cancels an alarm frame retransmission. Allows for turning off the internal flood sensor. Tamper and internal temperature sensors will remain active.