Clear Pulse Meter Counts (actual value is “don’t care”; count gets reset whenever this command is received regardless of value). This parameter is for SIG1 only. SIG1 triggered/untriggered sets or clears Relay1. Refer to description in User Manual under section, Input to Relay Mapping. Note that neither a Basic Report nor a Binary Switch Report is sent when relay is automatically set or cleared by Trigger Mapping. Only applies to the Relay1 output. SIG1 high lower threshold. Must be less than Upper Threshold Low and greater than Lower Threshold Low. SIG1 low lower threshold. SIG1 high upper threshold. SIG1 low upper threshold. Must be greater than Lower Threshold High and less than Upper Threshold High. Bits 7 - 2 are ignored and should be set to 0 Bit1 : Digital-Configuration flag 1=Set Trigger levels for this channel to ‘digital’ thresholds (approx. 1V); Default 0=Set Trigger levels to analog thresholds (see parameters 4 through 7) Bit0 : Trigger-Between-Thresholds flag (see below) 1 = Set to ‘triggered’ when input falls between thresholds; Default 0 = Set to ‘triggered’ when input falls outside of thresholds Periodic send interval of Multilevel Sensor Reports (Association Group 2) and/or Pulse Count Reports (Association Group 5) for SIG1. This parameter has a resolution of 10 seconds; for example, 1 = 10 seconds, 2 = 20 seconds, 3 = 30 seconds (Default), ... 255 = 2550 seconds = 42.5 minutes. A value of 0 disables automatic reporting. Momentary Relay1 output enable/disable. 1..255 = enable / value sets the approximate momentary on time in increments of 100msec.