Flush on off thermostat module responds to commands ALL ON / ALL OFF.
When I2 is trigged, setpoint will be set according to the value of this parameter.
Default value 32767 - Input 2 does not change setpoint.
0000 - 0990 - Setpoint from +00.0°C to +99.0°C, .1°C step.
1001 - 1150 - Setpoint from -00.1°C to -15.0°C, .1°C step.
When I2 is trigged, setpoint will be set according to the value of this parameter.
Default value 32767 - Input 3 does not change setpoint.
0000 - 0990 - Setpoint from +00.0°C to +99.0°C, .1°C step.
1001 - 1150 - Setpoint from -00.1°C to -15.0°C, .1°C step.
Set value from 0 - 100 (0% - 100%).
000: Reporting Disabled.
001 - 100 = 1% - 100%: Reporting enabled: power report is sent when actual power changes by more than set percentage comparing to previous actual power.
Step is 1%. Default value 003 -> 3%
Set value from 0 - 32767 seconds.
00000: Reporting Disabled.
00001 - 32767 = 1 second - 32767 seconds: Reporting enabled: power report is sent each time interval as set.
Default value 300 -> power report in Watts is sent every 300s
Minimal difference between measured temperature and setpoint to turn heating on.
Set from 0 to 255.
000 to 127 means from +00.0 °C to +12.7 °C, .1°C step.
128 to 255 means from -00.1 °C to -12.7 °C, .1°C step.
Default value 132 (= 128 + 004) -> -00.5 °C (= -00.1 + 00.4)
Minimal difference between measured temperature and setpoint to turn heating off.
Set from 0 to 255.
000 to 127 means from +00.0 °C to +12.7 °C, .1°C step.
128 to 255 means from -00.1 °C to -12.7 °C, .1°C step.
Default value 005 -> +00.5 °C
Temperature below which heater turns on even if the thermostat was manually set to off.
Set from 0 to 255.
000 to 127 means from +00.0 °C to +12.7 °C, .1°C step.
128 to 255 means from -00.1 °C to -12.7 °C, .1°C step.
Default value 050 -> +05.0 °C
Low temperature alarm is sent to Group 5 when temperature passes below set value.
Set from 0001 to 1000 = 000,1°C to 100,0 °C, .1°C step.
Default value 0050 -> +005.0 °C
If value is set out of range, the module resets the value to default.
High temperature alarm is sent to Group 4 when temperature passes below set value.
Set from 0001 to 1000 = 000,1°C to 100,0 °C, .1°C step.
Default value 0700 -> +070.0 °C
If value is set out of range, the module resets the value to default.
Type of heater connected to module output 'Q'. Default value 0 -> When heater off the output is 0 V.
Enabling I1 means that the Endpoint I1 will be present on the UI. Disabling it will result in hiding the endpoint according to the parameter set value. Additionally, a notification type and event can be selected for the endpoint.
Enabling I2 means that the Endpoint I2 will be present on the UI. Disabling it will result in hiding the endpoint according to the parameter set value. Additionally, a notification type and event can be selected for the endpoint.
Enabling I3 means that the Endpoint I3 will be present on the UI. Disabling it will result in hiding the endpoint according to the parameter set value. Additionally, a notification type and event can be selected for the endpoint.
Set value is added or subtracted to actual measured value by the sensor.
Default value 32536 -> +0°C
0001 - 0100 = value from +00,1°C to +10,0°C added to measurement
1001 - 1100 = value from -00,1°C to -10,0°C subtracted from measurement
When temperature sensor is connected, the module reports measured temperature on temperature change defined by this parameter.
Default value 005 = 00,5°C.
000 - Reporting disabled
001 - 127 = 00,1°C - 12,7°C, step .1°C