**Parameter**;**Datatype**;**Value Range**;**Explanation** name;string;;name of the static generator type;string;"| naming conventions: | *""PV""* - photovoltaic system | *""WP""* - wind power system | *""CHP""* - combined heating and power system";type of generator bus*;integer;;index of connected bus p_a_mw*;float;:math:`\leq` 0;active power of the static generator : Phase A[MW] q_a_mvar*;float;;reactive power of the static generator : Phase A [MVar] p_b_mw*;float;:math:`\leq` 0;active power of the static generator : Phase B[MW] q_b_mvar*;float;;reactive power of the static generator : Phase B [MVar] p_c_mw*;float;:math:`\leq` 0;active power of the static generator : Phase C[MW] q_c_mvar*;float;;reactive power of the static generator : Phase C [MVar] sn_mva;float;:math:`>` 0;rated power ot the static generator [MVA] scaling*;float;:math:`\geq` 0;scaling factor for the active and reactive power in_service*;boolean;True / False;specifies if the generator is in service.