**Parameter**;**Datatype**;**Value Range**;**Explanation** name;string;;name of the load bus *;integer;;index of connected bus p_mw*;float;:math:`\geq 0`;active power of the load [MW] q_mvar*;float;;reactive power of the load [MVar] const_z_percent*;float;:math:`[0,100]`;percentage of p_mw and q_mvar that is associated to constant impedance load at rated voltage [:math:`\%`] const_i_percent*;float;:math:`[0,100]`;percentage of p_mw and q_mvar that is associated to constant current load at rated voltage [:math:`\%`] sn_mva;float;:math:`>0`;rated power of the load [kVA] scaling *;float;:math:`\geq 0`;scaling factor for active and reactive power in_service*;boolean;True / False;specifies if the load is in service. type*;String;wye/delta;Connection Type of 3 Phase Load(Valid for three phase load flow only) controllable**;bool;;States if load is controllable or not, load will not be used as a flexibilty if it is not controllable max_p_mw**;float;;Maximum active power min_p_mw**;float;;Minimum active power max_q_mvar**;float;;Maximum reactive power min_q_mvar**;float;;Minimum reactive power