# pt-rtd ![Latest Version](https://img.shields.io/crates/v/pt-rtd.svg) ![Documentation](https://docs.rs/pt-rtd/badge.svg) ![License](https://img.shields.io/crates/l/pt-rtd.svg) ![Dependency Status](https://deps.rs/repo/github/thecodechemist99/pt-rtd/status.svg) ## Usage Add this to your `Cargo.toml`: ```toml [dependencies] pt-rtd = "0.1" ``` ## Examples Conversion of temperature and resistance values: ```rust,ignore use pt_rtd::{ self as rtd, RTDType, }; fn main() -> ! { let resistance: f32 = 100.0; let temperature: f32 = 0.0; // Convert resistance to temperature let result = rtd::calc_t(resistance, RTDType::PT100); let t = match result { Ok(temp) => temp, Err(e) => // handle error } // Convert temperature to resistance let result = rtd::calc_r(temperature, RTDType::PT100); let r = match result { Ok(res) => res, Err(e) => // handle error } } ``` For relative mesurements, the library can also convert the ADC reading to a resistance value: ```rust,ignore use pt_rtd::{ self as rtd, ADCRes, }; fn main() -> ! { let adc_value: u32 = 1000; let adc_resolution = ADCRes::B24; let ref_resistance = 5600; let pga_gain = 16; let result = rtd::conv_d_val_to_r(adc_value, ref_resistance, adc_resolution, pga_gain); let r = match result { Ok(res) => res, Err(e) => // handle error } } ``` ## License Licensed under either of Apache License, Version 2.0 or MIT license at your option.
Unless you explicitly state otherwise, any contribution intentionally submitted for inclusion in this crate by you, as defined in the Apache-2.0 license, shall be dual licensed as above, without any additional terms or conditions.