rmodbus - Modbus for Rust crates.io page docs.rs page GitHub Actions CI

A framework to build fast and reliable Modbus-powered applications. ## What is rmodbus rmodbus is not a yet another Modbus client/server. rmodbus is a set of tools to quickly build Modbus-powered applications. Consider rmodbus is a request/response codec, plus context manager. rmodbus is a part of [EVA ICS v4](https://www.eva-ics.com/) industrial automation stack and [RoboPLC](https://www.roboplc.com/) I/O. ## Why yet another Modbus lib? * rmodbus is transport- and protocol-independent * rmodbus is platform independent (**`no_std` is fully supported!**) * can be easily used in blocking and async (non-blocking) applications * tuned for speed and reliability * provides a set of tools to easily work with Modbus context * supports client/server frame processing for Modbus TCP/UDP, RTU and ASCII * server context can be easily managed, imported and exported ## So no server is included? Yes, there is no server included. You build the server by your own. You choose the transport protocol, technology and everything else. rmodbus just process frames and works with Modbus context. For synchronous servers and clients (std) we recommend using [RoboPLC Modbus I/O](https://docs.rs/roboplc/latest/roboplc/io/modbus/index.html) modules. Here is an example of a simple TCP blocking server: ```rust use std::io::{Read, Write}; use std::net::TcpListener; use std::thread; use std::sync::RwLock; use once_cell::sync::Lazy; use rmodbus::{ server::{storage::ModbusStorageFull, context::ModbusContext, ModbusFrame}, ModbusFrameBuf, ModbusProto, }; static CONTEXT: Lazy> = Lazy::new(<_>::default); pub fn tcpserver(unit: u8, listen: &str) { let listener = TcpListener::bind(listen).unwrap(); println!("listening started, ready to accept"); for stream in listener.incoming() { thread::spawn(move || { println!("client connected"); let mut stream = stream.unwrap(); loop { let mut buf: ModbusFrameBuf = [0; 256]; let mut response = Vec::new(); // for nostd use FixedVec with alloc [u8;256] if stream.read(&mut buf).unwrap_or(0) == 0 { return; } let mut frame = ModbusFrame::new(unit, &buf, ModbusProto::TcpUdp, &mut response); if frame.parse().is_err() { println!("server error"); return; } if frame.processing_required { let result = if frame.readonly { frame.process_read(&*CONTEXT.read().unwrap()) } else { frame.process_write(&mut *CONTEXT.write().unwrap()) }; if result.is_err() { println!("frame processing error"); return; } } if frame.response_required { frame.finalize_response().unwrap(); println!("{:x?}", response.as_slice()); if stream.write(response.as_slice()).is_err() { return; } } } }); } } ``` There are also examples for Serial-RTU, Serial-ASCII and UDP in *examples* folder (if you're reading this text somewhere else, visit [rmodbus project repository](https://github.com/alttch/rmodbus). Launch the examples as: ```shell cargo run --example app cargo run --example tcpserver ``` ## Modbus context The rule is simple: one standard Modbus context per application. 10k+10k 16-bit registers and 10k+10k coils are usually more than enough. This takes about 59Kbytes of RAM. rmodbus server context is thread-safe, easy to use and has a lot of functions. The context must be protected with a mutex/rwlock and every time Modbus context is accessed, a context mutex must be locked. This slows down performance, but guarantees that the context always has valid data after bulk-sets and after writes of long data types. So make sure your application locks context only when required and only for a short period time. A simple PLC example: ```rust,no_run use std::error::Error; use std::fs::File; use std::io::{Read, Write}; use rmodbus::server::{storage::ModbusStorageFull, context::ModbusContext}; #[path = "../examples/servers/tcp.rs"] mod srv; // put 1 to holding register 1500 to save current context to /tmp/plc1.dat // if the file exists, context will be loaded at the next start fn looping() { println!("Loop started"); loop { // READ WORK MODES ETC let ctx = srv::CONTEXT.read().unwrap(); let _param1 = ctx.get_holding(1000).unwrap(); let _param2 = ctx.get_holdings_as_f32(1100).unwrap(); // ieee754 f32 let _param3 = ctx.get_holdings_as_u32(1200).unwrap(); // u32 let cmd = ctx.get_holding(1500).unwrap(); drop(ctx); if cmd != 0 { println!("got command code {}", cmd); let mut ctx = srv::CONTEXT.write().unwrap(); ctx.set_holding(1500, 0).unwrap(); match cmd { 1 => { println!("saving memory context"); let _ = save("/tmp/plc1.dat", &ctx).map_err(|_| { eprintln!("unable to save context!"); }); } _ => println!("command not implemented"), } } // ============================================== // DO SOME JOB // .......... // WRITE RESULTS let mut ctx = srv::CONTEXT.write().unwrap(); ctx.set_coil(0, true).unwrap(); ctx.set_holdings_bulk(10, &(vec![10, 20])).unwrap(); ctx.set_inputs_from_f32(20, 935.77).unwrap(); } } fn save(fname: &str, ctx: &ModbusStorageFull) -> Result<(), Box> { let config = bincode::config::standard(); let mut file = File::create(fname)?; file.write(&bincode::encode_to_vec(ctx, config)?)?; file.sync_all()?; Ok(()) } fn load(fname: &str, ctx: &mut ModbusStorageFull) -> Result<(), Box> { let config = bincode::config::standard(); let mut file = File::open(fname)?; let mut data: Vec = Vec::new(); file.read_to_end(&mut data)?; (*ctx, _) = bincode::decode_from_slice(&data, config)?; Ok(()) } fn main() { // read context let unit_id = 1; { let mut ctx = srv::CONTEXT.write().unwrap(); let _ = load(&"/tmp/plc1.dat", &mut ctx).map_err(|_| { eprintln!("warning: no saved context"); }); } use std::thread; thread::spawn(move || { srv::tcpserver(unit_id, "localhost:5502"); }); looping(); } ``` To let the above program communicate with outer world, Modbus server must be up and running in the separate thread, asynchronously or whatever is preferred. ## `no_std` rmodbus supports `no_std` mode. Most of the library code is written the way to support both `std` and `no_std`. For `no_std`, set the dependency as: ```toml rmodbus = { version = "*", default-features = false } ``` ## Small storage The full Modbus storage has 10000 registers of each type, which requires 60000 bytes total. For systems with small RAM amount there is a pre-defined small storage with 1000 registers: ```rust use rmodbus::server::{storage::ModbusStorageSmall, context::ModbusContext}; ``` ## Custom-sized storage Starting from the version 0.7 it is allowed to define storage of any size using generic constants. The generic constants order is: coils, discretes, inputs, holdings. E.g. let us define a context for 128 coils, 16 discretes, 0 inputs and 100 holdings: ```rust use rmodbus::server::{storage::ModbusStorage, context::ModbusContext}; let context = ModbusStorage::<128, 16, 0, 100>::new(); ``` ## Custom server implementation Starting from the version 0.9 it is allowed to provide custom server implementation by implementing `use rmodbus::server::context::ModbusContext` on custom struct. For sample implementation have a look at `src/server/storage.rs` ## Vectors Some of rmodbus functions use vectors to store result. Different vector types can be used: - When the `std` feature is enabled (default), `std::vec::Vec` can be used. - With the `fixedvec` feature, [`fixedvec::FixedVec`](https://crates.io/crates/fixedvec) can be used. - With the `heapless` feature, [`heapless::Vec`](https://crates.io/crates/heapless) can be used. - When the `alloc` feature is enabled, Rust core allocation `alloc::vec::Vec` can be used in no-std mode. E.g `cargo build --no-default-features --features alloc` builds in no-std mode, and supports using core allocation `alloc::vec::Vec`. When `std` feature is enabled, the `alloc` feature is ignored. ## Modbus client Modbus client is designed with the same principles as the server: the crate gives frame generator / processor, while the frames can be read / written with any source and with any required way. TCP client Example: ```rust,no_run use std::io::{Read, Write}; use std::net::TcpStream; use std::time::Duration; use rmodbus::{client::ModbusRequest, guess_response_frame_len, ModbusProto}; fn main() { let timeout = Duration::from_secs(1); // open TCP connection let mut stream = TcpStream::connect("localhost:5502").unwrap(); stream.set_read_timeout(Some(timeout)).unwrap(); stream.set_write_timeout(Some(timeout)).unwrap(); // create request object let mut mreq = ModbusRequest::new(1, ModbusProto::TcpUdp); mreq.tr_id = 2; // just for test, default tr_id is 1 // set 2 coils let mut request = Vec::new(); mreq.generate_set_coils_bulk(0, &[true, true], &mut request) .unwrap(); // write request to stream stream.write(&request).unwrap(); // read first 6 bytes of response frame let mut buf = [0u8; 6]; stream.read_exact(&mut buf).unwrap(); let mut response = Vec::new(); response.extend_from_slice(&buf); let len = guess_response_frame_len(&buf, ModbusProto::TcpUdp).unwrap(); // read rest of response frame if len > 6 { let mut rest = vec![0u8; (len - 6) as usize]; stream.read_exact(&mut rest).unwrap(); response.extend(rest); } // check if frame has no Modbus error inside mreq.parse_ok(&response).unwrap(); // get coil values back mreq.generate_get_coils(0, 2, &mut request).unwrap(); stream.write(&request).unwrap(); let mut buf = [0u8; 6]; stream.read_exact(&mut buf).unwrap(); let mut response = Vec::new(); response.extend_from_slice(&buf); let len = guess_response_frame_len(&buf, ModbusProto::TcpUdp).unwrap(); if len > 6 { let mut rest = vec![0u8; (len - 6) as usize]; stream.read_exact(&mut rest).unwrap(); response.extend(rest); } let mut data = Vec::new(); // check if frame has no Modbus error inside and parse response bools into data vec mreq.parse_bool(&response, &mut data).unwrap(); for i in 0..data.len() { println!("{} {}", i, data[i]); } } ``` ## About the authors [Bohemia Automation](https://www.bohemia-automation.com) / [Altertech](https://www.altertech.com) is a group of companies with 15+ years of experience in the enterprise automation and industrial IoT. Our setups include power plants, factories and urban infrastructure. Largest of them have 1M+ sensors and controlled devices and the bar raises higher and higher every day.