设置强制充放电信息;Set mandatory charging and discharging information 10K:直流正母线备份电压5/6K: 二级母线1;10K: DC positive bus backup voltage 5/6K: Secondary bus 1 10K:直流负母线备份电压5/6K: 二级母线2;10K: DC negative bus backup voltage 5/6K: Secondary bus 2 AC侧自检步骤;AC side self-test steps AC侧运行模式;AC side operation mode AC侧运行状态;AC side running status AC耦合PV源选择;AC coupled PV source selection bin中固定内容;Fixed content in bin BMS告警信息显示;BMS alarm information display bms连接状态;bms connection status DC侧电池类型;DC side battery type DC侧自检步骤;DC side self-test steps DC侧运行状态;DC side running status IP获取类型;IP acquisition type 工作模式;Operating mode Operating mode设置2;Operating mode setting 2 Operating mode设置;Operating mode setting PV1 电压;PV1 voltage PV1 电流;PV1 current PV2 功率;PV2 power PV2 电压;PV2 voltage PV2 电流;PV2 current PVI 功率;PVI power PV侧自检步骤;PV side self-test steps PV侧运行状态;PV side running status PV并离网;PV and off-grid PV总功率(并机数据);PV total power (parallel data) PV状态字;PV status word SOC<10时是否充电(尖);Whether to charge (tip) when SOC<10 SOC<10时是否充电(尖);Whether to charge when SOC<10 (tip) SOC<10时是否充电(峰);Whether to charge (peak) when SOC<10 SOC<10时是否充电(峰);Whether to charge when SOC<10 (peak) SOC<10时是否充电(平);Whether to charge (flat) when SOC<10 SOC<10时是否充电(平);Whether to charge when SOC<10 (flat) SOC<10时是否充电(谷);Whether to charge (valley) when SOC<10 SOC<10时是否充电(谷);Whether to charge when SOC<10 (valley) SOC>20时是否放电(尖);Whether to discharge (tip) when SOC>20 SOC>20时是否放电(尖);Whether to discharge when SOC>20 (tip) SOC>20时是否放电(峰);Whether to discharge (peak) when SOC>20 SOC>20时是否放电(峰);Whether to discharge when SOC>20 (peak) SOC>20时是否放电(平);Whether to discharge when SOC>20 (flat) SOC>20时是否放电(谷);Whether to discharge (valley) when SOC>20 SOC>20时是否放电(谷);Whether to discharge when SOC>20 (valley) Wifi工作模式;Wifi working mode 三相不平衡输出;Three-phase unbalanced output 主/从机标志;master/slave flag 主函数地址;main function address 今日节省电费;Save money on electricity today 充/放电次数;Charge/discharge times 充放电状态;Charge and discharge status 充电功率上限;Charging power limit 充电截止电压;charge cut-off voltage 光伏总发电量;Total photovoltaic power generation 光伏日发电量;PV daily power generation 光储一体机协议pcu升级协议;Optical storage all-in-one machine protocol pcu upgrade protocol 光储一体机协议;optical storage all-in-one machine protocol 共有多少组数据;How many sets of data are there 共有多少组数据;How many sets of data are there in total 功率因数设置;power factor setting 功率降额标志;power derating flag 升级DSP程序;Upgrade DSP program 升级PCU程序;Upgrade PCU program 升级数据;upgrade data 升级的应用程序CRC;Upgraded application CRC 升级的应用程序长度;Upgraded Application Length 升级结果;upgrade result 协议版本号;protocol version number 单位电价(尖);unit electricity price (tip) 单位电价(峰);unit electricity price (peak) 单位电价(平);unit electricity price (flat) 单位电价(谷);unit electricity price (valley) 单/并机标志;Single/Parallel logo 单并机标志;Single parallel machine sign 后备负载供电顺序;Backup load power supply sequence 后备输出功能;backup output function 后续设置寄存器个数(最大10个);Subsequent setting of the number of registers (maximum 10) 周一是否使能;Whether to enable Monday 周三是否使能;Whether to enable Wednesday 周二是否使能;Whether to enable Tuesday 周五是否使能;Whether to enable Friday 周六是否使能;Whether to enable Saturday 周四是否使能;Whether to enable Thursday 周日是否使能;Whether to enable Sunday 固定内容0000;Fixed content 0000 字符;character 寄存器地址;register address 寄存器查询;Register query 寄存器的值;register value 寄存器设置;Register settings 尖峰平谷;peaks and valleys 工作参数设置2;Working parameter setting 2 工作效率;work efficiency 市电充电电流上限;Mains charging current upper limit 并机地址;Parallel address 并机电池接线类型;Parallel battery connection type 并机运行台数;The number of units running in parallel 并网SOC下限设置;Grid-connected SOC lower limit setting 并网今日用电量;Grid-connected electricity consumption today 并网功率上限;Grid-connected power upper limit 并网总用电量;Grid-connected total power consumption 开关机;switch machine 强冲一天时间段数;Forcibly rush the number of time periods in a day 强制充放电信息;Forced charge and discharge information 强制充电soc上限;Force charging soc upper limit 当日电池充电;Battery charging on the day 当日电池放电;battery discharge on the day 当日电网买电;The grid buys electricity on the same day 微网模式下电池SOC回差;In the micro grid mode the battery SOC hysteresis 总功率数据;total power data 总日电池充电;total daily battery charge 总日电池放电;total daily battery discharge 总电网买电;total grid electricity purchase 总节省电费;total savings on electricity bills 恢复出厂设置;reset 控制命令设置;Control command settings 控制柜信息显示;Control cabinet information display 放电功率下限;Lower limit of discharge power 放电截止电压;discharge cut-off voltage 故障状态字0;Fault status word 0 故障状态字1;Fault status word 1 故障状态字2;Fault status word 2 故障状态字3;Fault status word 3 故障状态字4;Fault status word 4 旁路模式是否使能;Whether bypass mode is enabled 时间校准设置;Time Calibration Settings 是否开启强制充电;Whether to enable forced charging 是否开启强制放电;Whether to enable forced discharge 最大允许充电电流;maximum allowable charging current 最大允许放电电流;Maximum allowable discharge current 服务器IP;server IP 服务器端口号;server port number 本地WIFI模块网络配置;Local WIFI module network configuration 本地负载A相有功功率(并机数据);Local load phase A active power (parallel data) 本地负载B相有功功率(并机数据);Local load B-phase active power (parallel data) 本地负载C相有功功率(并机数据);Local load phase C active power (parallel data) 本地负载无功功率(并机数据);Local load reactive power (parallel data) 本地负载有功功率(并机数据);Local load active power (parallel data) 本地负载视在功率(并机数据);Local load apparent power (parallel data) 机内温度;internal temperature 机型代码;model code 查询DRM状态;Query DRM status 查询路由器和服务器;Query routers and servers 模块 A1 温度;Module A1 temperature 模块 B1 温度;Module B1 temperature 模块 C1 温度;Module C1 temperature 油机额定功率;engine rated power 电池soc;battery soc 电池soh;battery soh 电池信息显示;Battery information display 电池充放电功率(指令模式有效);Battery charging and discharging power (command mode is valid) 电池充放电(指令模式生效);Battery charging and discharging (command mode takes effect) 电池功率手动限幅;Battery power manual limiter 电池厂商号(代码列表);Battery manufacturer number (code list) 电池压力;battery pressure 电池告警0;battery warning 0 电池总充电电流(并机数据);Total battery charging current (parallel data) 电池总功率(并机数据);Total battery power (parallel data) 电池总放电电流(并机数据);Total battery discharge current (parallel data) 电池总电流(并机数据);Total battery current (parallel data) 电池有告警;battery warning 电池有错误;battery error 电池温度;battery temperature 电池激活;battery activated 电池状态;battery status 电池电压上限;battery voltage upper limit 电池电压下限;battery voltage lower limit 电池电压是否可设;Whether the battery voltage can be set 电池电压;battery voltage 电池电流1;battery current 1 电池电流2;battery current 2 电池电流;battery current 电池通信协议选择;Battery communication protocol selection 电池通讯连接状态;Battery communication connection status 电网 AB 线电压;Grid AB line voltage 电网 A 相电压;Grid A phase voltage 电网 A 相电流;Grid A phase current 电网 BC 线电压;Grid BC line voltage 电网 B 相电压;Grid B phase voltage 电网 B 相电流;Grid B-phase current 电网 CA 线电压;Grid CA line voltage 电网 C 相电压;grid phase C voltage 电网 C 相电流;grid phase C current 电网代码;grid code 电网掉电;grid power down 电网电压跌落调节方式;Grid voltage drop adjustment method 电网电池电量数据;Grid battery power data 电网电池类型设置;Grid battery type setting 电网电量数据;Grid power data 电网频率;grid frequency 电表检测功能;Meter detection function 电表连接状态;Meter connection status 电表通讯协议选择;Meter communication protocol selection 直流功率;DC power 直流双边母线电压;DC bilateral bus voltage 直流正母线电压;DC positive bus voltage 直流负母线电压;DC negative bus voltage 离网SOC下限设置;Off-grid SOC lower limit setting 系统信息查询;System Information Query 系统故障状态显示;System fault status display 系统视在功率;system apparent power 结束时间;End Time 继电器自检使能;Relay self-test enable 综合电池告警1;Comprehensive battery warning 1 网侧无功功率;grid-side reactive power 网侧有功功率;Grid-side active power 自定义模式设置;Custom Mode Settings 要查询的寄存器个数(最大10个);The number of registers to be queried (up to 10) 设备类型编码;device type code 设备运行状态;Equipment running status 设置WIFI密码;Set WIFI password 设置云端服务器信息;Set cloud server information 设置参数信息2;Set parameter information 2 设置参数查询;Set parameter query 设置路由器信息;Set router information 设置路由器和服务器;Set up routers and servers 负载A相电压;Load phase A voltage 负载A相电流;load phase A current 负载B相电压;Load phase B voltage 负载B相电流;load phase B current 负载C相电压;Load phase C voltage 负载C相电流;load phase C current 负载今日用电量;load today's power consumption 负载功率因数;load power factor 负载总用电量;Total load power consumption 负载无功功率;load reactive power 负载日用电量;load daily power consumption 负载有功功率;load active power 负载电压频率;load voltage frequency 负载电量数据;Load power data 负载视在功率;load apparent power 起始时间;start time 路由器PASSWORD;Router PASSWORD 路由器SSID;router SSID 软件版本号低位;The lower digit of the software version number 软件版本号高位;The high digit of the software version number 运行DSP程序;run DSP program 运行PCU程序;Run the PCU program 远端负载功率;remote load power 远端负载;remote load 逆变 A 相电压;Invert A-phase voltage 逆变 A 相电流;Invert phase A current 逆变 B 相电压;Invert B-phase voltage 逆变 B 相电流;Invert B-phase current 逆变 C 相电压;Invert C-phase voltage 逆变 C 相电流;Invert C-phase current 逆变器状态字;inverter status word 逆变无功功率(并机数据);Inverter reactive power (parallel data) 逆变有功功率(并机数据);Inverter active power (parallel data) 逆变视在功率(并机数据);Invert apparent power (parallel data) 部分数据;part of data 铅酸电池AH值;AH value of lead-acid battery 铅酸电池EOD;Lead-acid battery EOD 铅酸电池均充电压;lead-acid battery charging voltage 铅酸电池浮充电压;Lead-acid battery float charge voltage 防逆流功能;anti-backflow function 防逆流功能;Anti-reflux function 阴影扫描;shadow scan 预留20个控制命令;Reserve 20 control commands 预留二十个控制命令;Twenty control commands are reserved 预留十个控制命令;Reserve ten control commands 预留字段;reserved fields 预留;reserve 角;d€ 元;€ 功率因数;power factor "unitType": "C";"unitType": "°C" ℃;°C HZ;Hz