0101Basic diagnostics model for understanding power prioritizationThe average grid voltage as reported by the GSLThe grid frequency as reported by the GSLThe real power being imported from or exported to the grid as reported by the GSLThe reactive power being imported from or exported to the grid as reported by the GSLThe export limit for real power based on the volt watt control algorithmThe target for real power based on the frequency watt control algorithmThe frequency watt control algorithm's active statusThe target for reactive power based on the watt var control algorithmThe target for reactive power based on the volt var control algorithmThe reference voltage used to run the volt var algorithmThe target for reactive power based on the constant power factor control algorithmThe target for reactive power based on the constant reactive power commandThe limit for real power based on the real power limitThe target for real power based on the real power settingThe real power command as requested by the GSLThe lower limit on real power as requested by the GSLThe upper limit on real power as requested by the GSLThe active status of the GSL's real power commandThe reactive power command as requested by the GSLPositive and negative threshold for reactive amps targetReactive amps adjustment from output capacitanceFinal output reactive amps after adjustments from the GSL, capacitance, and anti-islandingReactive amps target from GSLUsed to determine whether power flows toward or away from REbusPhase 1 component of real power amps reference total - allows us to balance power between the linesPhase 2 component of real power amps reference total - allows us to balance power between the linesIntegral form of the reactive amps targetTarget from divy - totalTarget from divy - phase 1 componentTarget from divy - phase 2 component Restricts all combined real and reactive amps from exceeding this limitNegative real power limit for phase 1Negative real power limit for phase 2Positive real power limit for phase 1Positive real power limit for phase 2Real power target dependent on mode - phase 1 componentReal power target dependent on mode - phase 2 componentAmps required to reach the real power target - phase 1 componentAmps required to reach the real power target - phase 2 componentCT target for self supply for phase 1CT target for self supply for phase 2CT target for zero export for phase 1CT target for zero export for phase 2CT target for zero import for phase 1CT target for zero import for phase 2CT target when generator connected for phase 1CT target when generator connected for phase 2