1 2 3 4 5 6 7 0 1 0 1 2 3 4 5 6 7 8 9 10 99 1 2 3 4 5 6 99 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 0 1 2 1 2 1 2 3 Nameplate charge capacity in amp-hours. Nameplate energy capacity in DC watt-hours. Maximum rate of energy transfer into the storage device in DC watts. Maximum rate of energy transfer out of the storage device in DC watts. Self discharge rate. Percentage of capacity (WHRtg) discharged per day. Manufacturer maximum state of charge, expressed as a percentage. Manufacturer minimum state of charge, expressed as a percentage. Setpoint for maximum reserve for storage as a percentage of the nominal maximum storage. Setpoint for minimum reserve for storage as a percentage of the nominal maximum storage. State of charge, expressed as a percentage. Measurement. Depth of discharge, expressed as a percentage. Measurement. Charge status of storage device. Enumeration. Battery control mode. Enumeration. Maps to DRCC.LocRemCtl in IEC 61850. Battery is controlled remotely (e.g. by the site controller). Value of 0 matches LocRemCtl in IEC 61850. Battery is controlled by a local operator (e.g. through battery HMI). Value of 1 matches LocRemCtl in IEC 61850. Value is incremented every second with periodic resets to zero. Value is incremented every second with periodic resets to zero. Used to reset any latched alarms. 1 = Reset. Battery should reset to 0 when reset is complete. Type of battery. Enumeration. Maps to DBAT.BatTyp in 61850. Battery type is not applicable or unknown. Lead-acid battery type. Nickel-metal hydrate battery type. Nickel-cadmium battery type. Lithium-ion battery type. Carbon-zinc battery type. Zinc chloride battery type. Alkaline battery type. Rechargeable alkaline battery type. Sodium-sulfur battery type. Flow battery type. Other battery type. State of the battery bank. Enumeration. Must be reconciled with State in IEC 61850. Battery bank is disconnected. All contactors are open. Battery bank is initializing but not ready for operating. String balancing may occur. Battery bank is ready for operation. All enabled contactors are closed. Battery bank is connected and in standby/power saving mode. Battery bank is connected but SoC is too low. Battery should be considered "offline". Battery bank is suspending operation and will disconnect. The battery has experienced a critical failure and may not be operated. Vendor specific battery bank state. Enumeration. Number of cycles executed in the battery. Percentage of battery life remaining. Date the device warranty expires. Number of days since 1/1/2000. Alarms and warnings. Bit flags. Unable to communicate with BMS or BMS is unable to communicate with battery strings. Battery has exceeded maximum operating temperature Battery is approaching maximum operating temperature. Battery has exceeded minimum operating temperature Battery is approaching minimum operating temperature. Battery maximum charge current has been exceeded. See AChaMax. Approaching battery maximum charge current. See AChaMax. Battery maximum discharge current has been exceeded. See ADisChaMax. Approaching battery maximum discharge current. See ADisChaMax. Battery voltage has exceeded maximum limit. Battery voltage is approaching maximum limit. Battery voltage has exceeded minimum limit. Battery voltage is approaching minimum limit. Battery state of charge has reached or exceeded SoCMin Battery state of charge is approaching SoCMin Battery state of charge has reached or exceeded SoCMax Battery state of charge is approaching SoCMax A voltage imbalance exists between the strings in the battery bank. A temperature imbalance exists between the strings in the battery bank. A temperature imbalance is developing between the strings in the battery bank. A contactor failed to open or close as requested. One or more battery fans has failed. Ground fault detected. One or more doors are open. A current imbalance exists between the strings in the battery bank. A vendor specific alarm has occurred. See EvtVnd1 and EvtVnd2 for more information. A vendor specific warning has occurred. See EvtVnd1 and EvtVnd2 for more information. Reserved bit. Do not implement. The battery bank has been configured incorrectly and will not operate. The battery bank has been configured incorrectly and may not operated as expected. Alarms and warnings. Bit flags. Reserved for future use. Vendor defined events. Vendor defined events. DC Bus Voltage. Maps to ZBAT.V in IEC 61850. Instantaneous maximum battery voltage. If not implemented, must implement AChaMax and ADisChaMax. Instantaneous minimum battery voltage. If not implemented, must implement AChaMax and ADisChaMax. Maximum voltage for all cells in the bank. Measurement. String containing the cell with maximum voltage. Module containing the cell with maximum voltage. Minimum voltage for all cells in the bank. Measurement. String containing the cell with minimum voltage. Module containing the cell with minimum voltage. Average cell voltage for all cells in the bank. Calculation based on measurements. Total DC current flowing to/from the battery bank. Measurement. Instantaneous maximum DC charge current. Setpoint. Changed to R/W by Generac. Instantaneous maximum DC discharge current. Setpoint. Changed to R/W by Generac. Total power flowing to/from the battery bank. Measurement. Request from battery to start or stop the inverter. Enumeration. Used in special states such as manual battery charging. Battery has no requests of the inverter. Battery requests that the inverter be started. Battery is notified of inverter state change through SetInvState. Battery requests that the inverter be stopped. Battery is notified of inverter state change through SetInvState. AC Power requested by battery. Used in special states such as string balancing. Instruct the battery bank to perform an operation such as connecting. Enumeration. Initialize the battery bank and close contactors for all enabled strings. Open contactors for all strings. Set the current state of the inverter. Information needed by battery for some operations. Scale factor for charge capacity. Scale factor for energy capacity. Scale factor for maximum charge and discharge rate. Scale factor for self discharge rate. Scale factor for state of charge values. Scale factor for depth of discharge. Scale factor for state of health. Scale factor for DC bus voltage. Scale factor for cell voltage. Scale factor for DC current. Scale factor for instantaneous DC charge/discharge current. Scale factor for AC power request.