01012345678012340123456789101112131415161718192021222324252627282930012345678910111213141516171819202122232425262728291212Number of strings in the bank.Number of strings with contactor closed.Maximum temperature for all modules in the bank.Measurement.String containing the module with maximum temperature.Module with maximum temperature.Minimum temperature for all modules in the bank.Measurement.String containing the module with minimum temperature.Module with minimum temperature.Average temperature for all modules in the bank.Calculation based on measurements.Maximum string voltage for all strings in the bank.Measurement.String with maximum voltage.Minimum string voltage for all strings in the bank.Measurement.String with minimum voltage.Average string voltage for all strings in the bank.Calculation based on measurements.Maximum current of any string in the bank.Measurement.String with the maximum current.Minimum current of any string in the bank.Measurement.String with the minimum current.Average string current for all strings in the bank.Calculation based on measurements.Total number of cells that are currently being balanced.Scale factor for cell voltage.Scale factor for module temperatures.Scale factor for string currents.Scale factor for string state of health.Scale factor for string state of charge.Scale factor for string voltage.Count of modules in the string.Current status of the string.String is enabled and will connect next time battery is asked to connect.String contactor is closed.If string has multiple contactors, indicates that all contactors are closed.Battery string state of charge, expressed as a percentage.Measurement.Battery string state of health, expressed as a percentage.Measurement.String current measurement.Measurement.Maximum voltage for all cells in the string.Measurement.Module containing the maximum cell voltage.Minimum voltage for all cells in the string.Measurement.Module containing the minimum cell voltage.Average voltage for all cells in the string.Calculation based on measurements.Maximum temperature for all modules in the bank.Measurement.Module with the maximum temperature.Minimum temperature for all modules in the bank.Measurement.Module with the minimum temperature.Average temperature for all modules in the bank.Calculation based on measurements.Reason why the string is currently disabled.No reason provided.A fault has occurred which caused the string to be disabled.The string has been disabled for maintenance reasons.The string has been disabled by an external user or controller.The string has been disabled for some other reason.Status of the contactor(s) for the string.Alarms, warnings and status values. Bit flags.String is unable to communicate with battery modules.Battery string has exceeded maximum operating temperatureBattery string is approaching maximum operating temperature.Battery string has exceeded minimum operating temperatureBattery string is approaching minimum operating temperature.Battery string maximum charge current has been exceeded.See AChaMax in model S 802.Approaching battery string maximum charge current.See AChaMax in model S 802.Battery string maximum discharge current has been exceeded.See ADisChaMax in model S 802.Approaching battery string maximum discharge current.See ADisChaMax in model S 802.Battery string voltage has exceeded maximum limit.Battery string voltage is approaching maximum limit.Battery string voltage has exceeded minimum limit.Battery string voltage is approaching minimum limit.Battery string state of charge has reached or exceeded SoCMinBattery string state of charge is approaching SoCMinBattery string state of charge has reached or exceeded SoCMaxBattery string state of charge is approaching SoCMaxA voltage imbalance exists between the modules in the battery string.A temperature imbalance exists between the modules in the battery string.A temperature imbalance is developing between the modules in the battery string.A contactor failed to open or close as requested.One or more battery fans has failed.Ground fault detected.One or more doors are open.Reserved bit.Do not implement.A vendor specific alarm has occurred.See EvtVnd1 and EvtVnd2 for more information.A vendor specific warning has occurred.See EvtVnd1 and EvtVnd2 for more information.Reserved bit.Do not implement.The battery string has been configured incorrectly and will not operate.The battery string has been configured incorrectly and may not operate as expected.Alarms, warnings and status values. Bit flags.Reserved for future use.Vendor defined events.Vendor defined events.Connect did not fail.A button was pushed which prevented connection.Ground fault during auto-connect.Outside voltage target window during auto-connect.The string is not enabled.A fuse is open which prevents connection.A contactor failed to operate.A failure during precharge occurred.A string fault has occurred.See StrEvt1 for more information.Enables and disables the string.Should reset to 0 upon completion.Enable the string.Disable the string.Connects and disconnects the string.Should reset to 0 upon completion.Connect the string.Disconnect the string.Pad register.Pad register.