0 1 0 1 2 3 4 5 6 7 8 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 0 1 1 2 Index of the string within the bank. Indices are one-based. Count of modules in the string. Current status of the string. String is enabled and will connect next time battery is asked to connect. String contactor is closed. If string has multiple contactors, indicates that all contactors are closed. Battery string state of charge, expressed as a percentage. Measurement. Battery string state of health, expressed as a percentage. Measurement. Depth of discharge for the string, expressed as a percentage. Measurement. String current measurement. Measurement. String voltage measurement. Measurement. Maximum voltage for all cells in the string. Measurement. Module containing the cell with maximum cell voltage. Minimum voltage for all cells in the string. Measurement. Module containing the cell with minimum cell voltage. Average voltage for all cells in the string. Calculation based on measurements. Maximum temperature for all modules in the string. Measurement. Module with the maximum temperature. Minimum temperature for all modules in the string. Measurement. Module with the minimum temperature. Average temperature for all modules in the string. Calculation based on measurements. Pad register. Status of the contactor(s) for the string. Alarms, warnings and status values. Bit flags. String is unable to communicate with battery modules. Battery string has exceeded maximum operating temperature Battery string is approaching maximum operating temperature. Battery string has exceeded minimum operating temperature Battery string is approaching minimum operating temperature. Battery string maximum charge current has been exceeded. See AChaMax in model S 802. Approaching battery string maximum charge current. See AChaMax in model S 802. Battery string maximum discharge current has been exceeded. See ADisChaMax in model S 802. Approaching battery string maximum discharge current. See ADisChaMax in model S 802. Battery string voltage has exceeded maximum limit. Battery string voltage is approaching maximum limit. Battery string voltage has exceeded minimum limit. Battery string voltage is approaching minimum limit. Battery string state of charge has reached or exceeded SoCMin. Battery string state of charge is approaching SoCMin. Battery string state of charge has reached or exceeded SoCMax. Battery string state of charge is approaching SoCMax. A voltage imbalance exists between the modules in the battery string. A temperature imbalance exists between the modules in the battery string. A temperature imbalance is developing between the modules in the battery string. A contactor failed to open or close as requested. One or more battery fans has failed. Ground fault detected. One or more doors are open. Reserved bit. Do not implement. A vendor specific alarm has occurred. See EvtVnd1 and EvtVnd2 for more information. A vendor specific warning has occurred. See EvtVnd1 and EvtVnd2 for more information. Reserved bit. Do not implement. The battery string has been configured incorrectly and will not operate as expected. The battery string has been configured incorrectly and may not operate as expected. Alarms, warnings and status values. Bit flags. Reserved for future use. Vendor defined events. Vendor defined events. Connect did not fail. A button was pushed which prevented connection. Ground fault during auto-connect. Outside voltage target window during auto-connect. The string is not enabled. A fuse is open which prevents connection. A contactor failed to operate. A precharge failure occurred. A string fault has occurred. See Evt1 for more information. Enables and disables the string. Should reset to 0 upon completion. Connects and disconnects the string. Should reset to 0 upon completion. Connect the string. Disconnect the string. Number of cells currently being balanced in the string. Number of discharge cycles executed upon the string. Scale factor for string state of charge. Scale factor for string state of health. Scale factor for string depth of discharge. Scale factor for string current. Scale factor for string voltage. Scale factor for cell voltage. Scale factor for module temperature. Pad register. Pad register. Pad register. Count of all cells in the module. Module state of charge, expressed as a percentage. Module state of health, expressed as a percentage. Maximum voltage for all cells in the module. Measurement. Cell with maximum voltage. Minimum voltage for all cells in the module. Measurement. Cell with minimum voltage. Average voltage for all cells in the module. Calculation based on measurements. Maximum temperature for all cells in the module. Measurement. Cell with maximum temperature. Minimum temperature for all cells in the module. Measurement. Cell with minimum temperature. Average temperature for all cells in the module. Calculation based on measurements. Pad register. Pad register. Pad register.