0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 0 1 2 3 4 5 0 1 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 0 1 2 3 4 5 0 1 2 3 4 5 6 7 8 1 2 1 2 0 1 2 3 4 Index of the string within the bank. Indices are one-based. Number of modules in this string. Number of electrically connected modules in this string. Maximum voltage for all modules in the string. Measurement. Module with the maximum voltage. Minimum voltage for all modules in the string. Measurement. Module with the minimum voltage. Average voltage for all modules in the string. Calculation based on measurements. Maximum voltage for all cells in the string. Measurement. Module containing the cell with the maximum voltage. Stack containing the cell with the maximum voltage. Minimum voltage for all cells in the string. Measurement. Module containing the cell with the minimum voltage. Stack containing the cell with the minimum voltage. Average voltage for all cells in the string. Calculation based on measurements. Maximum electrolyte temperature for all modules in the string. Measurement. Module with the maximum temperature. Minimum electrolyte temperature for all modules in the string. Measurement. Module with the minimum temperature. Average electrolyte temperature for all modules in the string. Calculation based on measurements. Alarms, warnings and status values. Bit flags. BMS is unable to communicate with modules. Battery string has exceeded maximum operating temperature Battery string is approaching maximum operating temperature. Battery string has exceeded minimum operating temperature Battery string is approaching minimum operating temperature. Battery string maximum charge current has been exceeded. See AChaMax in model S 802. Approaching battery string maximum charge current. See AChaMax in model S 802. Battery string maximum discharge current has been exceeded. See ADisChaMax in model S 802. Approaching battery string maximum discharge current. See ADisChaMax in model S 802. Battery string voltage has exceeded maximum limit. Battery string voltage is approaching maximum limit. Battery string voltage has exceeded minimum limit. Battery string voltage is approaching minimum limit. Battery string state of charge has reached or exceeded SoCMin. Battery string state of charge is approaching SoCMin. Battery string state of charge has reached or exceeded SoCMax. Battery string state of charge is approaching SoCMax A voltage imbalance exists between the modules in the string. Reserved bit. Do not implement. Reserved bit. Do not implement. A contactor failed to open or close as requested. One or more battery string fans has failed. Ground fault detected. One or more doors are open. Reserved bit. Do not implement. A vendor specific alarm has occurred. See EvtVnd1 and EvtVnd2 for more information. A vendor specific warning has occurred. See EvtVnd1 and EvtVnd2 for more information. A fire has been detected. The battery string has been configured incorrectly and will not operate. The battery string has been configured incorrectly and may not operate as expected. Alarms, warnings and status values. Bit flags. A leak has been detected. A pump has experienced an alarm condition or some other error. Pressure exceeds maximum value. Pressure approaching maximum value. Flow exceeds minimum value. Flow approaching minimum value. Vendor defined events. Vendor defined events. Scale factor for voltage. Scale factor for temperature. Scale factor for state of charge. Scale factor for open circuit voltage. Pad register. Index of the module within the string. Indices are one-based. Number of stacks in this module. Current status of the module. Module is enabled and will connect next time battery is asked to connect. Module contactor is closed. If module has multiple contactors, indicates that all contactors are closed. State of charge for this module. Open circuit voltage for this module. External voltage fo this module. Maximum voltage for all cells in this module. Measurement. Cell with the maximum cell voltage. Minimum voltage for all cells in this module. Measurement. Cell with the minimum cell voltage. Average voltage for all cells in this module. Calculation based on measurements. Alarms, warnings and status values. Bit flags. Module is unable to communicate with the BMS or other components. Module has exceeded maximum operating temperature Module is approaching maximum operating temperature. Module has exceeded minimum operating temperature Module is approaching minimum operating temperature. Module maximum charge current has been exceeded. See AChaMax in model S 802. Approaching module maximum charge current. See AChaMax in model S 802. Module maximum discharge current has been exceeded. See ADisChaMax in model S 802. Approaching module maximum discharge current. See ADisChaMax in model S 802. Module voltage has exceeded maximum limit. Module voltage is approaching maximum limit. Module voltage has exceeded minimum limit. Module voltage is approaching minimum limit. Module state of charge has reached or exceeded SoCMin. Module state of charge is approaching SoCMin. Module state of charge has reached or exceeded SoCMax. Module state of charge is approaching SoCMax. A voltage imbalance exists between the stacks in the module. Reserved bit. Do not implement. Reserved bit. Do not implement. A contactor failed to open or close as requested. One or more module fans has failed. Ground fault detected. One or more doors are open. Reserved bit. Do not implement. Reserved bit. Do not implement. Reserved bit. Do not implement. A fire has been detected. The battery module has been configured incorrectly and will not operate. The battery module has been configured incorrectly and may not operate as expected. Alarms, warnings and status values. Bit flags. A leak has been detected. A pump has experienced an alarm condition or some other error. Pressure exceeds maximum value. Pressure approaching maximum value. Flow exceeds minimum value. Flow approaching minimum value. Connect did not fail. A button was pushed which prevented connection. Ground fault during auto-connect. Outside voltage target window during auto-connect. The module is not enabled. A fuse is open which prevents connection. A contactor failed to operate. A failure during precharge occurred. A module fault has occurred. See ModEvt1 and ModEvt2 for more information. Enables and disables the module. Should reset to 0 upon completion. Enable the module. Disable the module. Connects and disconnects the module. Should reset to 0 upon completion. Connect the module. Disconnect the module. Reason why the module is currently disabled. No reason provided. A fault has occurred which caused the module to be disabled. The module has been disabled for maintenance reasons. The module has been disabled by an external user or controller. The module has been disabled for some other reason.