# Opcode: DFUN # Priority: Normal # Services: DCC_CAB or DCC_CMD # Parameters: Session (1 bytes), Fn1 (1 bytes), Fn2 (1 bytes) # Conditions: If the module is not a DCC command station then ignore the message. If the module does not have an active session with the specified session identifier then send an ERR (No session) message. # Direction: Cab to command station # States / Modes: # Result: If conditions are met then set the functions in the range given to the requested state.