TI BQ76920, BQ76930, BQ76940 HAL
Example usage, create instance, choose IC variant and cell count. Variant is chosen at compile time, as hardware is generally not changed on the fly. Cell count can be configured at runtime.
let mut bq76920 = BQ769x0::<{bq769x0::BQ76920}>::new(0x08, 4).unwrap();
new()
will return None if cell count is invalid. Valid configurations is:
Due to the use of const generics this is a nightly only crate for now.
Configure thresholds and timeouts:
let bq76920_config = BQ769x0Config {
shunt: MicroOhms(2000),
scd_delay: SCDDelay::_400uS,
scd_threshold: Amperes(100),
ocd_delay: OCDDelay::_640ms,
ocd_threshold: Amperes(50),
uv_delay: UVDelay::_4s,
uv_threshold: config::CELL_UV_THRESHOLD,
ov_delay: OVDelay::_4s,
ov_threshold: config::CELL_OV_THRESHOLD
};
let values = bq76920.init(i2c, &bq769x0_config).map_err(|e| Error::AfeError(e))?;
values
will contain actual OCD & SCD range used as well as under voltage and over voltage thresholds as they depend on ADC calibration values stored in the device.
init()
will return an error if:
Disable DSG and CHG fets (be carefull with CHG=1 && DSG=0 or CHG=0 and DSG=1 configurations):
bq76920.discharge(i2c, false)?;
bq76920.charge(i2c, false)?;
Enable ADC and Coulomd counter for voltage and current measurements:
bq76920.enable_adc(i2c, true)?;
bq76920.coulomb_counter_mode(i2c, bq769x0::CoulombCounterMode::Continuous)?;
Show voltage, current and calculate power as well (fixed point math only):
let i = bq76920.current(i2c);
let v = bq76920.voltage(i2c);
let p: Result<i32, bq769x0::Error> = i.and_then(|i| {
v.map(|v| i.0 * (v.0 as i32) / 1000)
});
match p {
Ok(p) => {
let intpart = p / 1000;
let fractpart = p - intpart * 1000;
writeln!(rtt, "V: {}, I:{}, Power: {}.{}W", v.unwrap(), i.unwrap(), intpart, fractpart.abs()).ok();
}
Err(e) => {
writeln!(rtt, "Read error={:?}", e).ok();
}
}
Show cell voltages:
match bq76920.cell_voltages(i2c) {
Ok(cells) => {
for (i, cell) in cells.iter().enumerate() {
writeln!(rtt, "Cell {}: {}", i + 1, cell).ok();
}
}
Err(e) => {
writeln!(rtt, "Read error={:?}", e).ok();
}
}
Show status and reset flags if needed:
let stat = bq76920.sys_stat(i2c);
writeln!(rtt, "{:?}", stat).ok();
let r = bq76920.sys_stat_reset(i2c, bq769x0::SysStat::SHORTCIRCUIT | bq769x0::SysStat::OVERCURRENT);
writeln!(rtt, "SCD|OCD clear: {:?}", r).ok();
Balancing is supported through enable_balancing()
and balancing_state()
, though is should be improved to not allow consecutive cells to balance.
Choose temperature source:
bq769x0.set_temperature_source(i2c, TemperatureSource::InternalDie);
Keep in mind that reading is not available right away, it will be scheculed internally and available after ?.
Read the temperature:
/// TODO: not finished, also mention and publish no hard float implementation of logarithm function.