This crate/repository is no longer maintained. Consider using the mpu9250 crate
MPU9250 driver for embedded devices and Linux written in Rust. A platform agnostic driver to interface with the MPU9250 over i2c. This driver was built using embedded-hal
traits.
Example code can be found in the /src/bin folder, this samples work in Linux devices with an i2c bus, like the Raspberry Pi and BeagleBone. The sample includes:
extern crate linux_embedded_hal as hal;
extern crate mpu9250_i2c as mpu9250;
use hal::{Delay, I2cdev};
use mpu9250::{calibration::Calibration, Mpu9250};
use std::time::Duration;
use std::thread;
fn main() {
// Linux device
let dev = I2cdev::new("/dev/i2c-2").unwrap();
// Set the calibration to the default setting. This can
// be set to a custom value specific for the device.
let cal = Calibration {
..Default::default()
};
let mpu9250 = &mut Mpu9250::new(dev, Delay, cal).unwrap();
// Initialise with default settings
mpu9250.init().unwrap();
// Probe the temperature
loop {
let temp = mpu9250.get_temperature_celsius().unwrap();
println!("Temp: {} °C", temp);
thread::sleep(Duration::from_millis(500));
}
}
}
Handy hint: Use the following command to compile for BeagleBone / Raspbery Pi.
cargo build --target=armv7-unknown-linux-musleabihf --release
The technology used in these devices is very noisy. Each component
requires a different calibration method. Compile the calibrate.rs
file which will produce a executable called calibrate
.
When run, calibrate
will give you instructions on how to calibrate.
Then after the calibration step for each component the calibration
settings unique for that device are printed to the console. These
values can be used in your code.
The calibration is temperature sensitive. Hence if you want to be
very precise you should repeat the calibration at different temperatures.
At a high-level the calibration does the following:
https://www.invensense.com/products/motion-tracking/9-axis/mpu-9250/
https://www.invensense.com/wp-content/uploads/2015/02/MPU-9250-Datasheet.pdf
https://www.invensense.com/wp-content/uploads/2015/02/MPU-9250-Register-Map.pdf
Copyright 2018 Simon M. Werner
Licensed under the Apache License, Version 2.0 (the "License"); you may not use this file except in compliance with the License.
You may obtain a copy of the License at http://www.apache.org/licenses/LICENSE-2.0. Unless required by applicable law or agreed to in writing, software distributed under the License is distributed on an "AS IS" BASIS, WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. See the License for the specific language governing permissions and limitations under the License.