Crates.io | solar-system-opt |
lib.rs | solar-system-opt |
version | 0.1.1 |
created_at | 2025-09-16 15:06:12.676119+00 |
updated_at | 2025-09-25 17:38:54.113592+00 |
description | LP optimization for solar system size based on consumption data |
homepage | |
repository | |
max_upload_size | |
id | 1841904 |
size | 607,031 |
A high-performance Rust implementation for optimizing solar energy systems using linear programming. This tool helps design and optimize residential and commercial solar energy systems with battery storage, heat pumps, electric vehicle charging, and grid integration.
# Clone the repository
git clone <repository-url>
cd p2p-ems/solar-system-opt
# Build the project
cargo build --release
# Run with default configuration
cargo run
# Run with individual day plots
cargo run days
use solar_system_opt::run_simple_opt;
use solar_system_opt::simple::solar_system_utils::OptimizationConfig;
fn main() -> Result<(), Box<dyn std::error::Error>> {
// Create default configuration
let config = OptimizationConfig::default();
// Load data
let solar_irradiance = load_solar_radiance_from_csv();
let electricity_demand = load_demand_from_csv();
// Run optimization
let results = run_simple_opt(
config,
8000.0, // Max PV capacity in W
solar_irradiance,
electricity_demand,
)?;
println!("Optimization completed!");
println!("Total cost: {:.2} €", results.total_cost);
println!("PV capacity: {:.2} W", results.pv_capacity);
println!("Battery capacity: {:.2} Wh", results.battery_capacity);
Ok(())
}
run_simple_opt
The main optimization function that performs linear programming optimization of solar energy systems.
pub fn run_simple_opt(
config: OptimizationConfig,
pv_cap_w_max: f64,
solar_irradiance: Vec<f64>,
electricity_demand: Vec<f64>,
) -> Result<SimpleOptimizationResults, Box<dyn std::error::Error>>
config
: OptimizationConfig
- Complete system configuration (see
Configuration section)pv_cap_w_max
: f64
- Maximum PV capacity in wattssolar_irradiance
: Vec<f64>
- Hourly solar irradiance values (8760
hours, 0-1 scale)electricity_demand
: Vec<f64>
- Hourly electricity demand in Wh (8760
hours)SimpleOptimizationResults
: Struct containing optimization results
including:
use solar_system_opt::run_simple_opt;
use solar_system_opt::simple::solar_system_utils::{OptimizationConfig, load_solar_radiance_from_csv, load_demand_from_csv};
fn optimize_residential_system() -> Result<(), Box<dyn std::error::Error>> {
// Create configuration for a typical residential system
let mut config = OptimizationConfig::default();
// Customize for residential use
config.electricity_usage = 4000.0 * 1000.0; // 4000 kWh annually in Wh
config.inv_pv = 800.0; // €800/kW PV cost
config.inv_bat = 300.0; // €300/kWh battery cost
config.fc_grid = 0.25; // €0.25/kWh grid electricity
config.feed_in_tariff = 0.08; // €0.08/kWh feed-in tariff
// Load time series data
let solar_irradiance = load_solar_radiance_from_csv();
let electricity_demand = load_demand_from_csv();
// Run optimization for 8 kW max PV system
let results = run_simple_opt(
config,
8000.0, // 8 kW in watts
solar_irradiance,
electricity_demand,
)?;
// Print results
println!("=== Residential Solar System Optimization ===");
println!("Optimal PV capacity: {:.2} kW", results.pv_capacity / 1000.0);
println!("Optimal battery capacity: {:.2} kWh", results.battery_capacity / 1000.0);
println!("Total system cost: {:.2} €", results.total_cost);
println!("Annual PV production: {:.2} kWh", results.total_pv_production / 1000.0);
println!("Annual grid consumption: {:.2} kWh", results.total_grid_consumption / 1000.0);
println!("Self-consumption rate: {:.1}%", results.self_consumption_rate);
Ok(())
}
use solar_system_opt::run_simple_opt;
use solar_system_opt::simple::solar_system_utils::{
OptimizationConfig, HeatingType, InsulationLevel, BuildingTypeEnum,
YearCategoryESEnum, MonthlyDemand, load_solar_radiance_from_csv, load_demand_from_csv
};
fn optimize_advanced_system() -> Result<(), Box<dyn std::error::Error>> {
let mut config = OptimizationConfig::default();
// Enable heat pump system
config.heat_pump_enabled = true;
config.house_square_meters = 150.0; // 150 m² house
config.building_type = BuildingTypeEnum::SingleFamily;
config.construction_period = YearCategoryESEnum::Between1977and1995;
config.insulation_standard = InsulationLevel::Good;
config.heating_type = HeatingType::Floor; // Underfloor heating
config.inv_heat_pump = 200.0; // €200/kW heat pump cost
// Enable electric vehicle
config.electric_car_enabled = true;
config.car_daily_km = 60.0; // 60 km per day
config.car_efficiency_kwh_per_km = 0.18; // 0.18 kWh/km
config.car_battery_size_kwh = 60.0; // 60 kWh battery
config.car_charge_during_day = true; // Charge during daytime
// Set monthly demand for more accurate optimization
config.monthly_demand = Some(MonthlyDemand {
january: 450.0,
february: 420.0,
march: 380.0,
april: 350.0,
may: 320.0,
june: 300.0,
july: 290.0,
august: 300.0,
september: 330.0,
october: 380.0,
november: 420.0,
december: 450.0,
});
// Load data
let solar_irradiance = load_solar_radiance_from_csv();
let electricity_demand = load_demand_from_csv();
// Run optimization
let results = run_simple_opt(
config,
12000.0, // 12 kW max PV
solar_irradiance,
electricity_demand,
)?;
println!("=== Advanced System with Heat Pump and EV ===");
println!("PV capacity: {:.2} kW", results.pv_capacity / 1000.0);
println!("Battery capacity: {:.2} kWh", results.battery_capacity / 1000.0);
println!("Heat pump capacity: {:.2} kW", results.heat_pump_capacity / 1000.0);
println!("Total cost: {:.2} €", results.total_cost);
println!("Heat pump consumption: {:.2} kWh", results.total_heat_pump_consumption / 1000.0);
println!("EV charging: {:.2} kWh", results.total_car_charging / 1000.0);
Ok(())
}
use solar_system_opt::run_simple_opt;
use solar_system_opt::simple::solar_system_utils::{OptimizationConfig, load_solar_radiance_from_csv, load_demand_from_csv};
fn optimize_for_autonomy() -> Result<(), Box<dyn std::error::Error>> {
let mut config = OptimizationConfig::default();
// Optimize for maximum autonomy instead of minimum cost
config.optimize_for_autonomy = true;
// Set high feed-in tariff to encourage overproduction
config.feed_in_tariff = 0.15; // €0.15/kWh
// Increase battery capacity limit
config.bat_value = 50000.0; // 50 kWh max battery
// Load data
let solar_irradiance = load_solar_radiance_from_csv();
let electricity_demand = load_demand_from_csv();
// Run optimization
let results = run_simple_opt(
config,
15000.0, // 15 kW max PV
solar_irradiance,
electricity_demand,
)?;
println!("=== Autonomy Optimization ===");
println!("PV capacity: {:.2} kW", results.pv_capacity / 1000.0);
println!("Battery capacity: {:.2} kWh", results.battery_capacity / 1000.0);
println!("Grid autonomy: {:.1}%", results.grid_autonomy);
println!("Self-consumption: {:.1}%", results.self_consumption_rate);
Ok(())
}
The OptimizationConfig
struct contains all system parameters:
pub inv_pv: f64, // PV investment cost (€/kW)
pub inv_bat: f64, // Battery investment cost (€/kWh)
pub inv_hwat: f64, // Hot water storage cost (€/kWh)
pub inv_grid: f64, // Grid connection cost (€/kW)
pub inv_heat_pump: f64, // Heat pump cost (€/kW)
pub annuity: f64, // Annuity factor for investments
pub fc_grid: f64, // Grid electricity cost (€/kWh)
pub feed_in_tariff: f64, // Feed-in tariff (€/kWh)
pub storage_loss_bat: f64, // Battery hourly loss rate
pub eta_in_bat: f64, // Battery charging efficiency
pub eta_out_bat: f64, // Battery discharging efficiency
pub c_rate_limit: f64, // C-rate limit (fraction of capacity per hour)
pub electricity_usage: f64, // Annual electricity usage (Wh)
pub electric_car_enabled: bool, // Enable/disable EV charging
pub car_daily_km: f64, // Daily kilometers driven
pub car_efficiency_kwh_per_km: f64, // Car efficiency (kWh/km)
pub car_battery_size_kwh: f64, // Car battery size (kWh)
pub car_charge_during_day: bool, // Day/night charging preference
pub heat_pump_enabled: bool, // Enable/disable heat pump
pub house_square_meters: f64, // House size (m²)
pub building_type: BuildingTypeEnum, // Building type
pub construction_period: YearCategoryESEnum, // Construction period
pub insulation_standard: InsulationLevel, // Insulation quality
pub heating_type: HeatingType, // Floor or radiator heating
The system expects CSV files in the data/
directory:
ts_res.csv
- Solar irradiance time series (8760 hours, 0-1 scale)demand.csv
- Base electricity demand pattern (8760 hours, kWh)when2heat_processed_2022.csv
- Heat demand data for insulation
calculationsAll time series must contain exactly 8760 hourly values representing a full year.
# Run optimization with default settings
cargo run
# Run with individual day plots (shows detailed daily profiles)
cargo run days
# Build release version for better performance
cargo build --release
./target/release/solar-system-opt
# Run with custom data directory
RUST_LOG=info cargo run
The system generates several types of output:
cargo run days
)pub struct SimpleOptimizationResults {
pub pv_capacity: f64, // Optimal PV capacity (W)
pub battery_capacity: f64, // Optimal battery capacity (Wh)
pub grid_capacity: f64, // Required grid capacity (W)
pub heat_pump_capacity: f64, // Heat pump capacity (W)
pub total_cost: f64, // Total system cost (€)
pub total_pv_production: f64, // Annual PV production (Wh)
pub total_grid_consumption: f64, // Annual grid consumption (Wh)
pub self_consumption_rate: f64, // Self-consumption rate (%)
pub grid_autonomy: f64, // Grid autonomy (%)
// ... hourly data vectors for detailed analysis
}
good_lp
crategood_lp
- Linear programming solvercalamine
- Excel file readingplotters
- Plotting and visualizationems-model
- Building energy model integrationserde
- Serialization supportThe system provides comprehensive error handling:
cargo fmt
cargo test